GW_Commercial-Smart-Inverter-Solutions_User-Manual-ET30-EN

Bu sayfa, kılavuzun PDF dosyasındaki metnin tamamıdır (sayfa sayfa). Görseller ve çizimler için PDF'i açın. — sibastore.com

Sayfa 1

Commercial and Industrial Smart Inverter

ET Series 12-30kW
• Lynx C Series Commercial and Industrial Battery 60kWh
• BAT-C Series Commercial and Industrial Battery 61.4-112.6kWh
• BAT-S Series High-Voltage Battery 15.3-56.3kWh

Solutions Manual

Sayfa 2

Copyright Statement

Copyright Statement

All Rights Reserved© GoodWe Technologies Co., Ltd. 2026. All rights reserved.

Without authorization from GoodWe Technologies Co., Ltd., no content of this manual may be 

reproduced, disseminated, or uploaded to public networks or other third-party platforms in any form.

Trademark Authorization

GOODWE and other GOODWE trademarks used in this manual are the property of GoodWe 

Technologies Co., Ltd. All other trademarks or registered trademarks mentioned in this manual belong 

to their respective owners.

NOTICE

Due to product version upgrades or other reasons, the content of this document is updated 

periodically. Unless otherwise agreed, the content of this document cannot replace the safety 

precautions on the product label. All descriptions in this document are for guidance only.

1

Sayfa 3

About This Manual

Overview

This document primarily introduces the product information, installation wiring, 
configuration and commissioning, troubleshooting, and maintenance content for the 
energy storage system composed of inverters, the Battery system, and smart meters. 
Please read this manual carefully before installing and using the product to 
understand product safety information and familiarize yourself with the product's 
functions and features. The document may be updated periodically; please obtain 
the latest version of the materials and more product information from the official 
website.

Applicable Model

The energy storage system includes the following products:

Product 

Type
Product Information
Description

Inverter
ET 12-30kW
Nominal output power 12kW to 
30kW.

Battery 

system

Lynx C series 60kWh commercial 
and industrial battery system

BAT-S series 15.3-56.3kWh high-
voltage battery

Single cluster storage capacity 
60kWh.
Parallel cluster storage capacity up 
to 180kWh.

Single cluster storage capacity 
15.3/20.4/25.6/30.7/35.8/40.9/46.0/
51.2/56.3 kWh.
Parallel cluster storage capacity up 
to 
91.8/122.4/153.6/184.2/214.8/245.4/
276.0/307.2/337.8 kWh.

2

Sayfa 4

Product 

Type
Product Information
Description

BAT-C series   61.4-
112.6kWh commercial and 
industrial battery system

GM3000

GM330
Meter

GMK330

WiFi/LAN Kit-20

LS4G Kit-CN, 4G Kit-CN, 4G Kit-
CN-G20 or 4G Kit-CN-G21 (China 
only)

smart 
dongle

Wi-Fi Kit

Ezlink3000

Symbol Definition

Indicates a situation with a high potential hazard, which, if not avoided, will result 
in death or serious injury.

Single cluster storage capacity 
61.4/92.1/102.4/112.6kWh.

Monitoring module in the energy 
storage system, capable of detecting 
operating voltage, current, and 
other information in the system.

Can upload system operating 
information to the monitoring 
platform via WiFi or LAN signals.

Can upload system operating 
information to the monitoring 
platform via 4G signals.

Can upload system operating 
information to the monitoring 
platform via WiFi signals.

In parallel machine scenarios, 
connected to the main inverter. Can 
upload system operating 
information to the monitoring 
platform via WiFi or LAN signals.

DANGER

WARNING

3

Sayfa 5

Indicates a situation with a moderate potential hazard, which, if not avoided, could 
result in death or serious injury.

Indicates a situation with a low potential hazard, which, if not avoided, could result 
in moderate or minor injury.

Emphasis and supplement to the content, which may also provide tips or tricks for 
optimal product use, helping you solve a problem or save your time.

CAUTION

NOTICE

4

Sayfa 6

1 Safety Precautions
12

1.1 General Safety
12

1.2 personnel requirements
13

1.3 System Safety
13

1.3.1 PV String Safety
15

1.3.2 Inverter Safety
16

1.3.3 Battery Safety
17

1.3.4 Smart Meter Safety
19

1.4 Safety Symbols and Certification Marks
20

1.5 EU Declaration of Conformity
21

1.5.1 Equipment with Wireless Communication Modules
21

1.5.2 Equipment without Wireless Communication Modules (Except Battery) 22

1.5.3 Battery
22

2 System Introduction
24

2.1 System Overview
24

2.2 Product Overview
29

2.2.1 Inverter
29

2.2.2 Battery
31

2.2.2.1 Lynx C Series 60kWh C&I Battery System
32

2.2.2.2 BAT-S Series 15.3-56.3kWh High Voltage Battery
33

2.2.2.3 BAT Series 61.4-112.6kWh C&I Battery System
37

Table of Contents

5

Sayfa 7

2.2.3 Smart Meter
48

2.2.4 smart dongle
49

2.3 Supported Grid Types
50

2.4 System Working Mode
51

2.5 Features
61

3 Check and Storage
65

3.1 Check Before Receiving
65

3.2 deliverables
65

3.2.1 Inverter Deliverables
65

3.2.2 Batteries Deliverables
68

3.2.2.1 Lynx C Series 60kWh C&I Battery System
68

3.2.2.2 BAT-S Series 15.3-56.3kWh High Voltage Battery
72

3.2.2.3 BAT Series 61.4-112.6kWh C&I Battery System
76

3.2.3 Smart Meter Deliverables (GM3000)
77

3.2.4 Smart Meter Deliverables GM330 & GMK330
78

3.2.4.1 Accessory List
78

3.3 Storage
79

4 Installation
82

4.1 System Installation and Commissioning Procedure
82

4.2 Installation Requirements
83

4.2.1 Installation Environment Requirements
83

4.2.2 Foundation Requirements
86

6

Sayfa 8

4.2.3 Installation Space Requirements
87

4.2.4 Tool Requirements
89

4.3 Equipment Handling
91

4.4 Installing the Inverter
95

4.5 Installing the Battery System
99

4.5.1 Opening the Cabinet Door
99

4.5.2 Installing the Lynx C Series 60kWh C&I Battery System
100

4.5.3 Installing the BAT-S Series 15.3-56.3kWh High Voltage Battery
101

4.5.4 Installing the BAT Series 61.4-112.6kWh C&I Battery System
105

4.6 Installing the Smart Meter
107

5 System Wirings
109

5.1 System Wiring Electrical Block Diagram
109

5.2 Detailed System Wiring Diagram
112

5.2.1 Detailed System Wiring Diagram for Single Inverter
113

5.2.2 Detailed System Wiring Diagram for Parallel System
118

5.3 Preparing Materials
121

5.3.1 Preparing Breakers
122

5.3.2 Preparing Cables
126

5.3.3 Removing the Cover Plate
129

5.4 Connecting the PE cable
131

5.4.1 Inverter Grounding
132

5.4.2 Battery System Grounding
132

7

Sayfa 9

5.5 Connecting the PV Cable
133

5.6 Connecting the Battery System Cables
135

5.6.1 With Lynx C Series 60kWh C&I Battery System
139

5.6.1.1 Battery Cable Entry Port Introduction
139

5.6.1.2 Connecting the Power Cable between the Inverter and Battery
140

5.6.1.3 Connecting the Battery Communication Cable
144

5.6.1.4 Connecting the Internal Power Busbars of the Battery System
146

5.6.1.5 Connecting the Air Conditioner Power Cable for the Battery 
System

5.6.1.6 Connecting the Air Conditioner Drain Pipe for the Battery System 148

5.6.1.7 Turning On the Fire Protection Switch
148

5.6.1.8 Installing the Cover Plate
150

5.6.2 With BAT-S Series 15.3-56.3kWh High Voltage Battery
150

5.6.2.1 Connecting the Power Cable between the Inverter and Battery
151

5.6.2.2 Connecting the Power Cable between Battery Units
154

5.6.2.3 Connecting the Communication Cable
154

5.6.3 With BAT Series 61.4-112.6kWh C&I Battery System
156

5.6.3.1 Battery Cable Entry Port and System Wiring Introduction
157

5.6.3.2 Connecting the Power Cable between the Inverter and Battery
158

5.6.3.3 Connecting the Battery Communication Cable
158

5.6.3.4 Connecting the Battery Air Conditioner Cable
159

5.6.3.5 Installing the Bottom Plate and Releasing the Emergency Stop 
Switch

8

147

160

Sayfa 10

5.7 Connecting the AC Cable
161

5.8 Connecting the Meter Cable
162

5.9 Connecting the Inverter Communication Cable
167

5.10 Connecting the Smart Dongle
174

6 System Commissioning
177

6.1 Check Before Power ON
177

6.2 Power ON
177

6.3 Indicators
179

6.3.1 Inverter Indicators
179

6.3.2 Battery Indicators
180

6.3.3 Smart Meter Indicator
182

6.3.4 Smart Dongle Indicator
183

6.4 Closing the Cabinet Door
187

7 System Commissioning & Power Plant Monitoring
190

7.1 Device Commissioning and Power Plant Monitoring via SEMS+ App
190

7.2 Device Commissioning and Power Plant Monitoring via SEMS+ WEB
191

8 Maintenance
193

8.1 Power OFF the System
193

8.2 Removing the Equipment
194

8.3 Disposing of the Equipment
195

8.4 Routine Maintenance
195

8.5 fault
196

9

Sayfa 11

8.5.1 Viewing Fault/Alarms Information
196

8.5.2 Fault Information and Troubleshooting
197

8.5.2.1 System Fault
197

8.5.2.2 Inverter Fault
199

8.5.2.2.1 Troubleshooting (Fault Code F01-F40)
199

8.5.2.2.2 Troubleshooting (Fault Code F41-F80)
216

8.5.2.2.3 Troubleshooting (Fault Code F81-F121)
225

8.5.2.2.4 Troubleshooting (Fault Code F122-F163)
235

8.5.2.2.5 Troubleshooting Fault Phenomena
245

8.5.2.3 Battery Fault
263

8.5.3 Post-Fault Clearance Handling
278

8.5.3.1 Clearing AFCI Fault Warning
278

9 technical parameter
280

9.1 Inverter Parameters
280

9.2 Battery Parameters
295

9.2.1 Lynx C Series 60kWh C&I Battery System
295

9.2.2 BAT-S Series 15.3-56.3kWh High Voltage Battery
297

9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System
303

9.3 Smart Meter Technical Data
307

9.3.1 GM330
307

9.3.2 GM3000
308

9.3.3 GMK330
309

10

Sayfa 12

9.4 Smart Dongle Technical Data
310

9.4.1 4G Kit-CN-G21
311

9.4.2 4G Kit-CN-G20
312

9.4.3 WiFi/LAN Kit-20
313

9.4.4 Ezlink3000
313

10 Appendix
315

10.1 FAQ
315

10.1.1 How to conduct auxiliary detection for smart meters/CT?
315

10.1.2 How to Upgrade the Device Version
315

10.2 Abbreviations
316

10.3 Explanation of Terms
319

10.4 Battery SN Code Meaning
320

10.5 Safety Standard Countries
321

11 Contact Details
328

11

Sayfa 13

1 Safety Precautions

The Safety Precautions information contained in this document must always be 
followed when operating the equipment.

The device has been strictly designed and tested in accordance with safety 
regulations. However, as electrical equipment, any operation must comply with 
relevant safety instructions. Improper handling may result in serious injury or 
property damage.

1.1 General Safety

WARNING

NOTICE

12

Sayfa 14

•

The content of this document may be updated periodically due to product 
version upgrades or other reasons. Unless otherwise agreed, the document 
content cannot replace the safety precautions on the product labels. All 
descriptions in the document are for guidance only.

Please read this document carefully before installing the device to understand 
the product and the precautions.
•

•

All operations on the device must be performed by professional and qualified 
electrical technicians who are familiar with the relevant standards and safety 
regulations at the project location.

•

When operating the device, use insulated tools and wear personal protective 
equipment to ensure personal safety. When touching electronic components, 
wear anti-static gloves, anti-static wrist straps, anti-static clothing, etc., to protect 
the device from electrostatic damage.

Unauthorized disassembly or modification may cause device damage, which is 
not covered under warranty.
•

•

Device damage or personal injury caused by failure to install, use, or configure 
the device in accordance with the requirements of this document or the 
corresponding user manual is beyond the manufacturer’s liability. For more 
product warranty information, please visit the official website: 
https://en.goodwe.com/warrantyrelated.html.

1.3 System Safety

DANGER

13

Sayfa 15

•

Before performing electrical connections, disconnect all upstream switches of 
the equipment to ensure the equipment is de-energized. Live operation is strictly 
prohibited, otherwise risks such as electric shock may occur.

•

For equipment supporting PV string connection, the PV input terminals have 
weak surge current capability. It is strictly forbidden to power on the equipment 
directly from the PV ports using a DC voltage source. If it is necessary to power 
on from the PV ports, please follow the steps below. Damage caused by 
improper operation is considered⼈为损坏 and is not covered by the product 
warranty.

First, limit the output current of the DC voltage source within the maximum 
input current range allowed by the PV ports.
1. 

Then close the DC switch of the inverter.
2. 

Finally, slowly increase the output voltage of the DC source from zero to the 
target value at a rate of ≤50V/s.
3. 

To prevent personal injury or equipment damage caused by live operation, a 
circuit breaker must be added to the voltage input side of the equipment.
•

•

All operations such as transportation, storage, installation, operation, use, and 
maintenance must comply with applicable laws, regulations, standards, and 
specifications.

The specifications of cables and components used for electrical connections must 
comply with local laws, regulations, standards, and specifications.
•

•

Please use the cable connectors provided in the box to connect the equipment 
cables. If other models of connectors are used, any resulting equipment damage 
is not within the responsibility of the equipment manufacturer.

Ensure all equipment cables are connected correctly, securely, and without 
looseness. Improper wiring may cause poor contact or damage the equipment.
•

The equipment's protective earth wire must be securely connected.
•

•

To protect the equipment and its components from damage during 
transportation, ensure transport personnel are professionally trained. Record the 
operation steps during transportation and keep the equipment balanced to 
avoid dropping.

•

The equipment is heavy. Please deploy personnel corresponding to the 
equipment weight to prevent the equipment from exceeding the weight limit for 
manual handling, which could cause injury.

Ensure the equipment is placed stably and not tilted. Equipment tipping over 
may cause equipment damage and personal injury.
•

14

Sayfa 16

Avoid letting the wiring terminals bear weight during equipment installation, 
otherwise the terminals may be damaged.
•

•

If the cable is subjected to excessive pulling force, it may cause poor connection. 
When wiring, leave a certain length of cable slack before connecting it to the 
equipment's wiring port.

•

Cables of the same type should be bundled together. Cables of different types 
should be routed separately with a minimum spacing of 30mm. Intertwining or交
叉布放 is prohibited.

•

Using cables in high-temperature environments may cause insulation aging or 
damage. Maintain a distance of at least 30mm between cables and发热器件 or 
the periphery of heat source areas.

1.3.1 PV String Safety

WARNING

15

Sayfa 17

Ensure the component frame and mounting system are properly grounded.
•

•

After completing the DC cable connections, ensure the connections are tight and 
secure with no looseness. Improper wiring may lead to poor contact or high 
impedance, and damage the inverter.

•

Use a multimeter to measure the positive and negative poles of the DC cables to 
ensure correct polarity and no reverse connection; and ensure the voltage is 
within the allowable range.

•

Use a multimeter to measure the DC cables to ensure correct polarity and no 
reverse connection; the voltage should be lower than the maximum DC input 
voltage. Damage caused by reverse connection and overvoltage is not covered 
by the equipment manufacturer's warranty.

•

The PV string output does not support grounding. Before connecting the PV 
string to the inverter, ensure the minimum insulation resistance to ground of the 
PV string meets the minimum insulation impedance requirement (R=Max. Input 
Voltage (V)/30mA).

Do not connect the same PV string to multiple inverters, as this may cause 
inverter damage.
•

The photovoltaic modules used with the inverter must comply with IEC 61730 
Class A standards.
•

When the input voltage or input current of the photovoltaic string is high, it may 
cause the inverter output power to derate.
•

1.3.2 Inverter Safety

WARNING

16

Sayfa 18

Ensure that the voltage and frequency of the grid connection point comply with 
the inverter's grid connection specifications.
•

•

It is recommended to add protective devices such as circuit breakers or fuses on 
the AC side of the inverter. The specification of the protective device should be 
greater than 1.25 times the maximum AC output current of the inverter.

•

If the inverter triggers an arc fault alarm less than 5 times within 24 hours, the 
alarm can be automatically cleared. After the 5th arc fault alarm, the inverter will 
shut down for protection. The inverter can resume normal operation only after 
the fault is cleared.

If no battery is configured in the photovoltaic system, it is not recommended to 
use the BACK-UP function, as it may cause a risk of system power outage.
•

Changes in grid voltage and frequency may cause the inverter output power to 
derate.
•

1.3.3 Battery Safety

WARNING

17

Sayfa 19

•

Before operating any equipment in the system, ensure the equipment is 
powered off to avoid the risk of electric shock. Strictly adhere to all safety 
precautions in this manual and the safety labels on the equipment during 
operation.

•

Do not disassemble, modify, or repair the battery or control box without official 
authorization from the equipment manufacturer. Doing so may cause electric 
shock or equipment damage, and any resulting losses are beyond the 
manufacturer’s liability.

Do not strike, pull, drag, squeeze, or step on the equipment. Do not place the 
battery in fire, as there is a risk of explosion.
•

•

Do not place the battery in a high-temperature environment. Ensure there are no 
heat sources nearby and that it is not exposed to direct sunlight. A fire may occur 
if the ambient temperature exceeds 60°C.

Do not use the battery or control box if there are obvious defects, cracks, 
damage, or other issues. Battery damage may lead to electrolyte leakage.
•

Do not move the battery system while it is operating. If battery replacement or 
addition is required, please contact the after-sales service center.
•

•

A battery short circuit may cause personal injury. The instantaneous high current 
from a short circuit can release a large amount of energy, potentially causing a 
fire.

The battery DC circuit breaker must comply with the requirements of the AS/NZS 
5139 standard.
•

•

Battery current may be affected by factors such as temperature, Humidity, 
weather conditions, etc., which may lead to current limiting and impact load 
capacity.

If the battery fails to start, please contact the after-sales service center as soon as 
possible. Otherwise, the battery may be permanently damaged.
•

Please perform regular inspection and maintenance on the battery according to 
its maintenance requirements.
•

 
Emergency Response Measures

DANGER

WARNING

18

Sayfa 20

•

Battery electrolyte leakage
If electrolyte leaks from the battery module, avoid contact with the leaked liquid or 
gas. Electrolyte is corrosive and contact may cause skin irritation and chemical 
burns. If accidental contact with the leaked substance occurs, take the following 
actions:

inhalation: Evacuate from the contaminated area and seek medical help 
immediately.

○

Eye contact: Flush with clean water for at least 15 minutes and seek medical help 
immediately.

○

Skin contact: Wash the affected area thoroughly with soap and water and seek 
medical help immediately.

○

Ingestion: Induce vomiting and seek medical assistance immediately.
○

•

Fire

When the battery temperature exceeds 150°C, there is a risk of fire. A battery fire 
may release toxic and harmful gases.

○

To prevent fire, ensure that carbon dioxide, Novec1230, or FM-200 fire 
extinguishers are available near the equipment.

○

When extinguishing a fire, do not use ABC dry powder fire extinguishers. 
Firefighters must wear protective clothing and self-contained breathing 
apparatus.

○

•

Battery triggers fire protection
For batteries equipped with an optional fire protection function, after the fire 
protection function is triggered, perform the following actions:

Immediately cut off the main power switch to ensure no current flows through 
the battery system.

○

Conduct a preliminary visual inspection of the battery for any damage, 
deformation, leakage, or unusual odor. Check the battery casing, connectors, 
and cables.

○

Use a temperature sensor to detect the temperature of the battery and its 
surroundings to ensure there is no risk of overheating.

○

Isolate and label the damaged battery, and dispose of it properly according to 
local regulations.

○

1.3.4 Smart Meter Safety

19

Sayfa 21

If the grid voltage fluctuation exceeds 265V, long-term overvoltage operation may 
damage the meter. It is recommended to add a fuse with a rated current of 0.5A on 
the voltage input side of the meter to protect it.

1.4 Safety Symbols and Certification Marks

After the equipment is installed, the labels and warning signs on the enclosure 
must be clearly visible. Covering, altering, or damaging them is prohibited.
•

The following enclosure warning label descriptions are for reference only. Please 
refer to the actual labels used on the equipment.
•

No.
Symbol
Meaning

1
Potential hazard exists during equipment operation. Take 
protective measures when operating the equipment.

2
High voltage hazard. High voltage is present during 
equipment operation. Ensure the equipment is powered 
off before performing any operations.

3
The inverter surface is at high temperature. Do not touch 
during operation to avoid burns.

4
Use the equipment properly. There is a risk of explosion 
under extreme conditions.

5
The battery contains flammable materials. Beware of fire.

6
The equipment contains corrosive electrolyte. Avoid 
contact with leaked electrolyte or vapor.

7
Delayed discharge. After powering off the equipment, wait 
for 5 minutes until it is completely discharged.

8
Keep the equipment away from open flames or ignition 
sources.

WARNING

DANGER

20

Sayfa 22

No.
Symbol
Meaning

9
Keep the equipment out of reach of children.

10
Use the equipment properly. There is a risk of explosion 
under extreme conditions.

11
The battery contains flammable materials. Beware of fire.

12
Do not lift the equipment after the battery system wiring is 
completed or while the battery system is operating.

13
Do not extinguish with water.

14
Read the product manual carefully before operating the 
equipment.

15
Wear personal protective equipment during installation, 
operation, and maintenance.

16
   
 

17
Do not directly disconnect or plug/unplug the DC terminals 
while the equipment is operating.

18
Grounding point.

19
Recycling symbol.

20
CE certification mark.

21
TUV mark.

22
RCM mark.

1.5 EU Declaration of Conformity

Do not dispose of the equipment as household waste. 
Dispose of the equipment according to local laws and 
regulations, or return it to the manufacturer.

21

Sayfa 23

1.5.1 Equipment with Wireless Communication Modules

Equipment with wireless communication modules sold in the European market must 
comply with the following directives:

Radio Equipment Directive 2014/53/EU (RED)
•

Restrictions of Hazardous Substances Directive 2011/65/EU and (EU) 2015/863 
(RoHS)
•

Waste Electrical and Electronic Equipment 2012/19/EU
•

Registration, Evaluation, Authorization and Restriction of Chemicals (EC) No 
1907/2006 (REACH)
•

1.5.2 Equipment without Wireless Communication Modules (Except 
Battery)

Equipment without wireless communication functions that can be sold in the 
European market must meet the requirements of the following directives:

Electromagnetic compatibility Directive 2014/30/EU (EMC)
•

Electrical Apparatus Low Voltage Directive 2014/35/EU (LVD)
•

Restrictions of Hazardous Substances Directive 2011/65/EU and (EU) 2015/863 
(RoHS)
•

Waste Electrical and Electronic Equipment 2012/19/EU
•

Registration, Evaluation, Authorization and Restriction of Chemicals (EC) No 
1907/2006 (REACH)
•

1.5.3 Battery

Batteries that can be sold in the European market meet the requirements of the 
following directives:

Electromagnetic compatibility Directive 2014/30/EU (EMC)
•

Electrical Apparatus Low Voltage Directive 2014/35/EU (LVD)
•

Restrictions of Hazardous Substances Directive 2011/65/EU and (EU) 2015/863 
(RoHS)*1
•

Regulation (EU) 2023/1542 Article 12 - Safety of stationary battery energy storage 
systems
•

Regulation  (EU) 2023/1542 Article 10 - Performance and durability requirements 
•

22

Sayfa 24

for rechargeable industrial batteries, LMT batteries and electric vehicle batteries
Regulation (EU) 2023/1542 Article 14 - Information on the state of health and 
expected lifetime of batteries
•

Waste Electrical and Electronic Equipment 2012/19/EU
•

•

Registration, Evaluation, Authorization and Restriction of Chemicals (EC) No 
1907/2006 (REACH) 
*1: Our company's battery products meet the hazardous substance limit 
requirements stipulated by this regulation.

More EU Declarations of Conformity can be obtained from the official website.

23

Sayfa 25

2 System Introduction

2.1 System Overview

Commercial & Industrial Smart Inverter Solution integrates devices such as inverters, 
batteries, Smart Meters, and smart communication sticks. In a photovoltaic system, it 
converts solar energy into electricity to meet the power demands of commercial and 
industrial applications. The energy IoT devices in the system manage the electrical 
loads by identifying the overall power situation within the system, thereby achieving 
intelligent management of power for use by loads, storage in the battery, or export 
to the grid.

•

Select the battery model according to the inverter and battery compatibility list. 
For requirements regarding batteries used in the same system, such as whether 
models can be mixed or capacities must be consistent, please refer to the user 
manual of the corresponding battery model or contact the battery manufacturer 
for relevant requirements. Inverter and battery compatibility list: 
https://en.goodwe.com/Ftp/EN/Downloads/User%20Manual/GW_Battery%20Co
mpatibility%20Overview-EN.pdf.

•

Due to product version upgrades or other reasons, the document content will be 
updated periodically. For the compatibility relationship between inverters and 
IoT products, please refer to: 
https://en.goodwe.com/Ftp/EN/Downloads/User%20Manual/GW_Compatibility-
list-of-GoodWe-inverters-and-IoT-products-EN.pdf.

•

The PV system is not suitable for connecting devices that rely on stable power 
supply, such as life-sustaining medical equipment, etc. Please ensure that system 
power failure will not cause personal injury.

The BACK-UP function is not recommended for PV systems without a battery 
configured, as it may cause a system power failure risk.
•

The BACK-UP port does not support connecting auto-transformers or isolation 
transformers.
•

The battery current may be affected by factors such as temperature, Humidity, 
weather conditions, etc., which may lead to battery current limiting and affect 
•

WARNING

24

Sayfa 26

load capacity.
The inverter has a UPS function with a switching time of <10ms. Please ensure 
the BACK-UP Loads capacity is < the inverter's rated power. Otherwise, the UPS 
function may fail during a grid power outage.

•

The BACK-UP function is not recommended for PV systems without a battery 
configured, as it may cause a system power failure risk.
•

For detailed networking and wiring schemes for each scenario, please refer to: 
Detailed System Wiring Diagram.
•

•

When the inverter is in an off-grid state, it can be used normally for common 
household loads. However, the following loads need to be limited, such as:

inductive load: inductive load power < 0.4 times the inverter's rated output 
power.

○

Capacitive load: total power ≤ 0.66 x inverter rated output power.
○

The inverter does not support half-wave loads. Half-wave loads: Some old or 
non-EMC compliant appliances (such as hair dryers, small heaters using half-
wave rectification) may not work properly.

○

•

In a system where the inverter operates completely off-grid, if the battery is in 
low light or rainy weather for a long time and cannot be replenished in time, it 
may lead to over-discharge, causing battery performance degradation or 
damage. To ensure long-term stable system operation, avoid completely 
draining the battery. Recommended measures are as follows:

During off-grid operation, set the minimum SOC protection threshold. It is 
recommended to set the off-grid battery SOC lower limit to 30%.

○

When the SOC approaches the protection threshold, the system will 
automatically enter load limiting or protection mode.

○

If there are multiple consecutive days of insufficient sunlight and the battery 
SOC is too low, promptly replenish the battery using external energy sources 
(such as a generator or grid-assisted charging).

○

Regularly check the battery status to ensure it is within a safe operating range.
○

It is recommended to fully charge and discharge the battery every six months 
to calibrate the SOC accuracy.

○

WARNING

25

Sayfa 27

ON-GRID Load

BACK-UP Load

Smart Dongle £T3010NETOO13

26

Sayfa 28

Device 
Type
model
Description

GW12KL-ET
GW18KL-ET 
GW15K-ET 
GW20K-ET 
GW25K-ET 
GW29.9K-ET 
GW30K-ET

Inverter

Battery 
system

GW60KWH-D-10 
GW60KWH-D-10 
(without expansion 
cabinet)

Supports up to 4 inverters to form a 
parallel system.
•

•

Battery-ready models do not support 
forming a parallel system when the battery 
function is not activated.

Only machines with the same AC output 
voltage can form a parallel system.
•

•

GW12KL-ET and GW18KL-ET only support 
BAT-S Series 15.3kWh-56.3kWh batteries. 
And the following version requirements 
must be met:

Inverter ARM software version 17.449 or 
above.

○

Inverter DSP software version 13.13011 
or above.

○

•

In a coupling scenario, using a dual meter 
can simultaneously monitor grid-tied 
inverter power generation and load power 
consumption. The following version 
requirements must be met:

Inverter ARM software version 15.441 or 
above.

○

Inverter DSP software version 11.11060 
or above.

○

SolarGo version 6.9.0 or above.
○

The system supports up to 3 clusters of 
battery systems in parallel.

27

Sayfa 29

Device 
Type
model
Description

GW15.3-BAT-I-G10
GW20.4-BAT-I-G10
GW25.6-BAT-I-G10
GW30.7-BAT-I-G10
GW35.8-BAT-I-G10
GW40.9-BAT-I-G10
GW46.0-BAT-I-G10
GW51.2-BAT-I-G10
GW56.3-BAT-I-G10

GW61.4-BAT-AC-G10 
GW92.1-BAT-AC-G10 
GW102.4-BAT-AC-G10 
GW112.6-BAT-AC-G10

GM3000
•

Smart 
Meter

GM330
•

GMK330
•

Supports up to 6 clusters of battery 
systems in parallel.
•

Battery systems of different models cannot 
be mixed and used in parallel.
•

•

Due to battery operating voltage range 
limitations, GW15.3-BAT-I-G10 and 
GW20.4-BAT-I-G10 do not support GW15K-
ET, GW20K-ET, GW25K-ET, and GW30K-ET.

Only supports a single cluster.

GM3000: Included with the inverter, CT 
cannot be replaced, CT ratio: 120A: 40mA
•

•

GM330: CT can be purchased from 
GoodWe or independently, CT ratio 
requirement: nA: 5A

nA: CT primary side input current, n 
ranges from 200 to 5000

○

5A: CT secondary side output current
○

•

GMK330: CT shipped with the meter, CT 
ratio:

120A: 40mA
○

200A: 50mA (only Brazil)
○

28

Sayfa 30

Device 
Type
model
Description

•

For single unit, please use WiFi/LAN Kit-20, 
Wi-Fi Kit, LS4G Kit-CN, 4G Kit-CN, 4G Kit-CN-
G20, or 4G Kit-CN-G21 modules. If using 
WiFi/LAN Kit-20 to replace Wi-Fi Kit, please 
upgrade the inverter ARM firmware 
version to 08.401 or above before 
switching to WiFi/LAN Kit-20.

WiFi/LAN Kit-20
•

Wi-Fi Kit
•

•

LS4G Kit-CN、4G 
Kit-CN、4G Kit-CN-
G20 or 4G Kit-CN-
G21 (only China)

smart 
dongle

•

In parallel system, only the master inverter 
needs to be connected to Ezlink3000, slave 
inverters do not need communication 
modules. 
Ezlink3000 firmware version must be 04 or 
above.

Ezlink3000
•

2.2.1 Inverter

The Inverter in photovoltaic systems controls and optimizes energy flow through an 
integrated energy management system. It can supply the electricity generated in the 
photovoltaic system for load use, store it in batteries, or output it to the grid.

NOTICE

The appearance of inverters may vary across different power ranges. Please refer 
to the actual product.

No.
model
Nominal 
output power

Nominal output 
voltage

1
GW12KL-ET
12kW
1

2
GW18KL-ET
18kW
220V, 3L/N/PE
2

3
GW15K-ET
15kW
1

380/400V,3L/N/PE

4
GW20K-ET
20kW
1

29

Battery Port 
Quantity

Sayfa 31

No.
model
Nominal 
output power

Nominal output 
voltage

5
GW25K-ET
25kW
2

6
GW29.9K-ET
29.9kW
2

7
GW30K-ET
30kW
2

Component Introduction

Component/Silks

No.

Description

creen

1
DC Switch Lock 
Hole
Australia only.

2
DC Switch
Controls the connection or disconnection of the DC 
input.

Connect the DC input cables from the PV modules.

3
PV Input 
Terminals

GW15K-ET, GW20K-ET, GW12KL-ET x 2
•

GW25K-ET, GW29.9K-ET, GW30K-ET, GW18KL-ET x 3
•

4
Communication 
Module Port

Connect the communication module, supporting 4G and 
Wi-Fi/LAN modules.

Connect the communication cable, supporting 
communication with DRED, Remote Shutdown, Rapid 
Shutdown, RCR, EMS, and generator.

5
Communication 
Port

30

Battery Port 
Quantity

Sayfa 32

6
Battery 
Connection 
Port

7
BMS 
Communication 
Port

8
AC Port
Connect the AC cables, including the ON-GRID and 
BACK-UP ports.

9
METER 
Communication 
Port

10
Handle
For moving the inverter.

11
Indicator
Indicates the operating status of the inverter.

12
Grounding 
Terminal
Connect the protective ground wire for the enclosure.

13
Fan
For inverter cooling.

14
Inverter 
Mounting Slot
For mounting and securing the inverter.

Australian Junction Box Dimensions

2.2.2 Battery

Connect the battery DC cables.

GW15K-ET, GW20K-ET, GW12KL-ET x 1
•

GW25K-ET, GW29.9K-ET, GW30K-ET, GW18KL-ET x 2
•

Connect the battery communication cable.

GW15K-ET, GW20K-ET, GW12KL-ET x 1
•

GW25K-ET, GW29.9K-ET, GW30K-ET, GW18KL-ET x 2
•

Connect the smart meter.

31

Sayfa 33

The battery system consists of a PCU and a PACK.
The battery system can store and release electrical energy according to the 
requirements of the photovoltaic energy storage system. The input and output ports 
of this energy storage system are both high-voltage direct current.

A single battery cabinet does not support expansion by adding PACKs after 
installation.
•

•

BAT series battery systems can expand the cluster within one year after 
installation by adding battery cabinets of the same model and part number. For 
details, please consult the after-sales service.

2.2.2.1 Lynx C Series 60kWh Commercial & Industrial Battery System

No.
model
Rated Capacity 
(kWh)

1
GW60KWH-D-10
60
Yes

2
GW60KWH-D-10(without 
expansion cabinet)
60
No

NOTICE

Includes AC 
Cabinet

32

Sayfa 34

2.2.2.2 BAT-S Series 15.3-56.3kWh High Voltage Battery

No.
model
PACK Quantity
Rated Capacity (kWh)

1
GW15.3-BAT-I-G10
3
15.3

2
GW20.4-BAT-I-G10
4
20.4

3
GW25.6-BAT-I-G10
5
25.6

4
GW30.7-BAT-I-G10
6
30.7

33

Sayfa 35

No.
model
PACK Quantity
Rated Capacity (kWh)

5
GW35.8-BAT-I-G10
7
35.8

6
GW40.9-BAT-I-G10
8
40.9

7
GW46.0-BAT-I-G10
9
46.0

8
GW51.2-BAT-I-G10
10
51.2

9
GW56.3-BAT-I-G10
11
56.3

Dimension Description

Component Introduction

34

Sayfa 36

No.
Name
Description

1
Adjustable Feet
Adjustable height to keep the base level

2
Base
The battery system is stacked and placed on 
the base

Stack 
Installati
on

3
Floor Locking 
Bracket

4
Stacking Bracket
Fixed on the battery PACK for stack 
installation of batteries

1
Battery Rack
Used for installing the battery system

2
Wall Locking 
Bracket 
Mounting Hole

Used to secure the battery rack to the wall 
to prevent tipping
Rack 
Mountin
g

3
Floor Locking 
Bracket 
Mounting Hole

Used to secure the base to the floor to 
prevent tipping

Used to secure the battery rack to the floor 
to prevent tipping

35

Sayfa 37

No.
Name
Description

5
Protective 
Grounding Point
Used for connecting the ground wire

High-Voltage Box 
Power 
Input/Output 
Port 1

6

7
Battery 
Indicators
Used to indicate the battery system status

8
Dry Contact

High-Voltage Box 
Power 
Input/Output 
Port 2

9

10
External 
Communication 
Port

11
High-Voltage Box 
Communication 
Port

12
Battery System 
Switch

13
High-Voltage Box 
/ Battery PACK 
Mounting Hole

14
Battery Module 
Communication 
Port

Connects the power cable between the 
high-voltage box and the inverter

Contact for external fire protection system 
activation (Normally, the dry contact 
remains open. When a closed dry contact is 
detected, the battery system will 
automatically power down)

Connects the power cable between the 
high-voltage box and the battery module

Communicates with the inverter / Places 
termination resistor / Battery system cluster 
communication

Communicates with the battery module

Controls the start and stop of the battery 
system

Used to secure the high-voltage box / 
battery PACK to the battery rack

Used for communication between adjacent 
battery PACKs, and communication 
between battery PACK and high-voltage box

36

Sayfa 38

No.
Name
Description

Battery Module 
Power 
Input/Output 
Port

Connects the power cable between adjacent 
battery PACKs

15

16
Wall Locking 
Bracket 
Mounting Hole

Used for installing the wall locking bracket. 
Only the first and last battery PACKs require 
installation of the wall locking bracket.

2.2.2.3 BAT Series 61.4-112.6kWh Commercial & Industrial Battery System

No.
model
PACK Quantity
Rated Capacity 

1
GW61.4-BAT-AC-G10
6
61.4

2
GW92.1-BAT-AC-G10
9
92.1

3
GW102.4-BAT-AC-G10
10
102.4

4
GW112.6-BAT-AC-G10
11
112.6

37

(kWh)

Sayfa 39

No.
Name
Description

1
LED Indicator Light
-

2
Emergency Stop Button
Pressing the emergency stop button will 
power down the battery system.

3
Front Door Lock
-

4
PE Port 1
Connects to the battery grounding cable.

5
Bottom Baffle
-

6
Left Side Cable Entry 
Hole 1

7
Left Side Cable Entry 
Hole 2
Inverter communication cable.

8
Left Side Cable Entry 
Hole 3
Inverter power cable.

Air conditioner power cable & ET100 power 
cable.

38

Sayfa 40

No.
Name
Description

9
Right Side Cable Entry 
Hole 1
Battery cluster parallel power cable.

10
Right Side Cable Entry 
Hole 2
Battery cluster parallel communication cable.

11
Right Side Cable Entry 
Hole 3
Air conditioner power cable.

12
Back Mounting Plate 
Installation Hole

13
PE Port 2
Connects to the inverter grounding cable.

14
Air Conditioner
Responsible for temperature control; the air 
conditioner refrigerant model is R134A.

15
Rear Door Lock
-

16
Air Conditioner Drain 
Pipe Installation Port
-

17
Explosion-proof Valve

18
Communication Cable 
Inlet/Outlet (Bottom)

19
Power Cable Inlet/Outlet 
(Bottom)

20
Battery Communication 
Cable Inlet/Outlet

Installation hole position for the inverter back 
mounting plate.

Responsible for explosion-proof, exhaust, and 
other functions. 
When abnormal pressure increase occurs 
inside the battery system, by opening the 
explosion-proof one-way valve exhaust port, 
internal gas is quickly and directionally 
released to prevent the battery system from 
exploding.

Inlet/outlet for communication cables 
between the battery and inverter.

Inlet/outlet for power cables between the 
battery and inverter.

Inlet/outlet for battery cluster parallel 
communication cables.

39

Sayfa 41

No.
Name
Description

21
Battery Power Cable 
Inlet/Outlet (Positive)

22
Battery Power Cable 
Inlet/Outlet (Negative)

23
Foundation Fixing Hole
Used to fasten the battery system to the 
foundation.

24
Handle
-

25
Battery PACK Power 
Input/Output Port 
Positive

26
Battery PACK Power 
Input/Output Port 
Negative

27
Fan
-

28
Battery PACK 
Communication Port

29
High-voltage Box Power 
Input/Output Port 
Negative 1

30
High-voltage Box Power 
Input/Output Port 
Positive 1

31
Molded Case Circuit 
Breaker

32
Black Start Button
Controls the black start of the battery system.

33
Internal Communication 
Port 1

Inlet/outlet for battery cluster parallel power 
cables (positive).

Inlet/outlet for battery cluster parallel power 
cables (negative).

-

-

Communication between adjacent battery 
PACKs, communication with the high-voltage 
box, and fan power supply.

Connects the power cables between the high-
voltage box and battery PACK.

Controls the high-voltage output of the 
battery system.

Communication with battery PACK and 
battery PACK fan power supply port 1.

40

Sayfa 42

No.
Name
Description

34
Internal Communication 
Port 2

35
LAN Communication 
Port

36
External Communication 
Port 1

37
Air Switch
Controls the low-voltage power supply of the 
battery system.

38
High-voltage Box Power 
Input/Output Port 
Positive 2

39
High-voltage Box Power 
Input/Output Port 
Negative 2

40
Access Control Switch

Air conditioner communication, access 
control identification, emergency stop, and 
fire alarm signal communication port.

LAN communication between batteries, used 
for transmitting cell-level information 
(Only supported on machines shipped after 
October 2025).

Communication with inverter / placement of 
terminal resistor / battery system cluster 
parallel communication.

Connects the power cables between the high-
voltage box and inverter.

Connects the power cables between the high-
voltage box and inverter.

Automatically disconnects when the door is 
opened to ensure the energy storage system 
is powered off.

41

Sayfa 43

No.
Name
Description

41
Temperature Detector

42
Smoke Detector

The temperature detector monitors 
temperature through a dual thermistor 
network and outputs a voltage proportional 
to the external temperature. One thermistor 
is exposed to ensure good thermal contact 
with the surrounding air, while the other 
thermistor is thermally insulated; when an 
anomaly is detected, it emits red light to alert 
the operator.

Suitable for environments with dust or 
smoke under normal conditions.
•

Wide operating voltage range.
•

The smoke detector uses the principle of 
scattered light to detect smoke entering the 
detector's inner cavity.

Good response to slow-burning, 
smoldering fires.
•

Unaffected by wind or atmospheric 
pressure.
•

Some models are equipped with a flashing 
LED and magnetic test switch.
•

Alarm indicator: Red light-emitting diode 
(LED) emits red light.
•

42

Sayfa 44

No.
Name
Description

43
Aerosol Fire 
Extinguishing Device

44
Document Shelf
-

45
Fire Action Signal Port

46
Maintenance Hook Shelf

47
Lifting Ring Installation 
Hole
-

48
Air Conditioner Switch
Connects to the air conditioner power cable 
and controls the air conditioner power supply.

Fire Protection System Description

Monitors fire signals inside the cabinet and 
implements fire extinguishing.
When a fire occurs, the aerosol fire 
extinguishing device ignites the thermal fuse 
upon receiving an electrical start signal or 
open flame. The electric igniter thermal fuse 
burns and activates the aerosol generator in 
the fire extinguishing device. The aerosol 
generator releases heat through a series of 
reactions to decompose the chemical coolant, 
allowing the aerosol generator and coolant to 
combine for fire extinguishing.

Dry contact signal interface, normally NC 
(normally closed state). Voltage: 0-24Vdc, 
Current: 0.3A. Connects to the audible and 
visual alarm cable.

When disassembling the Pack and PCU, the 
maintenance hook can be taken from here for 
operation.

43

Sayfa 45

1
2
3
4

Smoke 
Detector

Heat 
Detector

Aerosol Fire Extinguishing 

Device

Temperature Detector & Smoke Detector
■

Temperature Detection Principle: The detector uses a negative temperature 
coefficient thermistor as the sensor, leveraging its sensitivity to ambient temperature 
to obtain environmental temperature information. The internal circuit converts this 
information into a voltage signal and transmits it to the microcontroller. The 
microcontroller analyzes and processes the signal using built-in intelligent 
algorithms to determine whether a fire alarm or fault condition is present. 
Smoke Detection Principle: The detector utilizes infrared light scattering principle 

44

Explosion-Proof 

Valve

Sayfa 46

to detect fires. In a smoke-free state, it receives only very weak infrared light. When 
smoke enters the optical smoke detection chamber, the scattered light enhances the 
received light signal. When the smoke concentration reaches a certain level, an alarm 
signal is output.

Technical 
Specifications

Dimensions (mm)
102 × 55

Installation 
Requirements
Screw Fixation

indicator (Red)
Flashes during monitoring, stays on 

Operating 
Temperature (℃)
-40~+85

Relative Humidity
≤95%RH (Non-condensing)

Explosion-Proof Valve
■

When the internal pressure of sealed products like battery enclosures rises rapidly, 
the explosion-proof check valve's exhaust port opens to quickly and directionally 
release the internal gas, thereby preventing explosions in sealed products such as 
battery boxes.

Temperature 

Smoke 
Detector

Detector

when alarming

45

Sayfa 47

Technical 
Specifications
Explosion Vent Valve

Ingress Protection 
Rating
IP68

Opening Area
570 mm2

Operating 
Temperature
-40℃ ~ +130℃

Flame Retardancy
UL94-V0

Aerosol Fire Extinguishing Device
■

When a fire occurs, upon receiving an electrical activation signal or when an open 
flame ignites the thermal fuse, the electric initiator or burning thermal fuse activates 
the aerosol-forming agent inside the fire extinguishing device. The heat released by 
the redox reaction of the aerosol-forming agent causes the chemical coolant to 
decompose, enabling both the aerosol-forming agent and the coolant to participate 
in fire suppression.

Technical 
Specifications
Aerosol Fire Extinguishing Device

Operating Ambient 
Temperature Range
-30℃ ~ +70℃

Operating Ambient 
Relative Humidity
≤95%RH

Thermal Activation 
Temperature
185±10℃

46

Sayfa 48

Fire Protection Logic

The fire protection for this battery system employs a graded response design. When 
a fire occurs inside a battery Pack, it is first detected by the Pack-level detector, which 
immediately activates the Pack's internal aerosol fire extinguishing device for initial 
suppression. If the fire is not controlled and spreads further, cabinet-level fire 
protection is triggered. When both the smoke detector and temperature detector 
detect a fire, or when an open flame ignites the thermal fuse (at a temperature of 
180°C), the cabinet-level aerosol fire extinguishing device is automatically activated 
for comprehensive fire suppression. The aerosol-forming agent produces 
extinguishing agents through a combustion reaction, and the heat released during 
the reaction decomposes the chemical coolant. The aerosol fire extinguishing agent 
and coolant work synergistically to extinguish the fire. Simultaneously, the BMS 
receives feedback signals from the fire protection system, triggering external audible 
and visual alarms until the fire is completely extinguished.

47

Sayfa 49

2.2.3 Smart Meter

The Smart Meter can measure parameters such as grid voltage, current, power, 
frequency, and electrical energy, and transmit this information to the inverter to 
control the input and output power of the energy storage system.

GM3000&CT

48

Sayfa 50

GM330&GMK330&CT

No.
model
Applicable Scenarios

1
GM3000
CT replacement not supported, CT ratio: 120A: 40mA

2
GM330

3
GMK330

2.2.4 smart dongle

The smart dongle is primarily used for real-time transmission of various inverter 

CT can be purchased from GoodWe or self-sourced, 

CT ratio requirement: nA: 5A

nA: CT primary side input current, the range of n is 200-
5000
•

5A: CT secondary side output current
•

CT shipped with the meter, CT ratio:

120A: 40mA
•

200A: 50mA (Brazil only)
•

49

Sayfa 51

power generation data to the SEMS Portal remote monitoring platform, and for 
connecting to the smart dongle via the SolarGo APP for local device commissioning 
and debugging.

No.
model
Signal Type
Applicable Scenario

1
Wi-Fi Kit
WiFi

2
WiFi/LAN Kit-20
WiFi, LAN, 
Bluetooth

3
LS4G Kit-CN
4G Kit-CN
4G

4G Kit-CN-G20
4G, Bluetooth
4
4G Kit-CN-G21
4G, Bluetooth, 
CNSS

5
Ezlink3000
WiFi, LAN, 
Bluetooth

2.3 Supported Grid Types

Single inverter scenario

Master unit in multi-inverter 
scenario

50

Sayfa 52

2.4 System Working Mode

Self-Use Mode

The fundamental operating mode of the system.
•

•

PV generation prioritizes supplying power to the loads. Excess power charges the 
battery, and any remaining power is sold to the grid. When PV generation is 
insufficient to meet the loads' demand, the battery supplies power to the loads. 
When the battery power is also insufficient, the grid supplies power to the loads.

51

Sayfa 53

Backup Mode

Recommended for use in areas with an unstable grid.
•

•

When the grid fails, the inverter switches to off-grid operation mode, and the 
battery discharges to supply power to the loads, ensuring uninterrupted power for 
the BACK-UP Loads. When the grid is restored, the inverter switches its operation 
mode back to grid-tied.

•

To ensure the battery SOC is sufficient to maintain normal system operation during 
off-grid periods, the system will charge the battery using PV or grid power to the 
backup power SOC during grid-tied operation. If purchasing electricity from the 
grid to charge the battery is required, please ensure it complies with local grid 
regulations and laws.

52

Sayfa 54

TOU Mode
Subject to compliance with local laws and regulations, buy and sell electricity during 
different time periods based on peak and off-peak grid electricity price differences.
For example: During off-peak price periods, set the battery to charging mode to 
purchase electricity from the grid for charging. During peak price periods, set the 
battery to discharging mode to supply power to the loads via the battery.

53

Sayfa 55

TOU Mode $\textcircled{1}$

PV: Charge battery in priority

TOU curve

Valley price
Peak price
Valley price
Peak price
Valley price

Battery fully charged
PV cannot cover load needs

Battery discharge
Battery charge
Self use
Remaining power export
PV curve

Load consumption

Charge
Discharge
Charge
Standby
Discharge
Charge

SLG00NET0004

Sayfa 56

Delayed Charging Mode

Suitable for areas with grid-connected power output limitations.
•

•

Setting a peak power limit can direct PV generation exceeding the grid-connection 
limit to charge the battery; or set a PV charging period to utilize PV generation for 
charging the battery during that period.

55

Sayfa 57

Delayed Charging $\textcircled{1}$

PV > Peak Limit
Switch to Charge: enabled/disabled

Battery discharge
Battery charge
Self use
Remaining power export
PV curve
Load consumption

PV covers load needs

Discharge
Standby
Charge
Standby
Discharge

SLG00NET0006

Sayfa 58

Delayed Charging $\textcircled{2}$

PV < Peak Limit
Switch to Charge: enabled

Battery discharge
Battery charge
Self use
Remaining power export
PV curve
Load consumption

Charging start
PV covers load needs
PV cannot cover load needs

Discharge
Standby
Charge
Standby
Discharge

SLG00NET0007

Sayfa 59

Demand Control Mode

Primarily applicable to commercial and industrial scenarios.
•

•

When the total load power consumption exceeds the electricity quota within a 
short period, battery discharge can be utilized to reduce the portion of 
consumption exceeding the quota.

•

When the SOC of both inverter battery strings is lower than the reserved SOC for 
demand control, the system purchases electricity from the grid based on the time 
period, load consumption, and the peak purchase power limit. When the SOC of 
only one inverter battery string is lower than the reserved SOC for demand control, 
the system purchases electricity from the grid based on the load consumption and 
the peak purchase power limit.

58

Sayfa 60

Peakshaving $\textcircled{1}$

BAT1/BAT2 SOC < 80

Reserved SOC For Peakshaving: 80

Grid supplies power to loads
Battery discharge
Battery charge
PV supplies power to loads
PV+battery supply power to loads
PV curve

Load consumption < Import Power Limit

Start Time

Import Power Limit

Grid+battery supply power to loads

Standby

Discharge

Charge

Standby

SLG00NET0010

Sayfa 61

Off-Grid Mode

Do not operate in pure off-grid mode when the inverter is not connected to the 
battery system.

When the grid fails, the inverter switches to off-grid operation mode.

During the day, PV generation prioritizes supplying power to the loads, with excess 
power charging the battery.
•

At night, the battery discharges to supply power to the loads, ensuring 
uninterrupted power for the BACK-UP Loads.
•

Off-Grid SOC Recovery: After the system operates off-grid, the battery gradually 
•

NOTICE

60

Sayfa 62

recovers to the minimum SOC level through PV generation or other power 
generation methods.

2.5 Features

Specific features are subject to the product's actual configuration.

AFCI
The inverter integrates an AFCI circuit protection device to detect arc faults and 
quickly cut off the circuit when detected, thereby preventing electrical fires.
Causes of arc faults:

NOTICE

61

Sayfa 63

Damaged connector connections in the PV system.
•

Incorrect or damaged cable connections.
•

Aging connectors or cables.
•

Arc Detection Method

The inverter integrates AFCI functionality, complying with the IEC 63027 standard.
•

When the inverter detects an arc fault, the time and fault phenomenon can be 
displayed via the App.
•

•

After the inverter triggers an AFCI alarm, it will shut down for protection. The 
inverter will automatically reconnect to the grid and resume operation after the 
alarm is cleared.

Auto-reconnection: If the inverter triggers an AFCI alarm < 5 times within 24 
hours, the alarm can be automatically cleared after five minutes, and the inverter 
will reconnect to the grid and resume operation.

○

Manual reconnection: If the inverter triggers the 5th AFCI alarm within 24 hours, the 
alarm must be cleared manually before the inverter can reconnect to the grid and 
resume operation.

model
Label
Description

GW12KL-ET
GW15K-ET

F-I-AFPE-1-2/2-2

GW20K-ET

GW18KL-ET
GW20K-ET
GW29.9K-ET

F-I-AFPE-1-2/4-2

GW30K-ET

 
Three-Phase Unbalanced Output

F: Full coverage 
I: Integrated 
AFPE: Detection and interruption capability 
provided 
1: 1 monitored string per input port 
2/2: 2/2 input ports per channel 
2: 2 monitored channels

F: Full coverage 
I: Integrated 
AFPE: Detection and interruption capability 
provided 
1: 1 monitored string per input port 
2/4: 2/4 input ports per channel 
2: 2 monitored channels

62

Sayfa 64

The inverter's grid-tie port and BACK-UP port both support three-phase unbalanced 
output, allowing loads of different power ratings to be connected to each phase. The 
maximum output power per phase for different models is shown in the table below:

No.
model
Maximum Output Power per Phase

1
GW12KL-ET
4kW

2
GW18KL-ET
6kW

3
GW15K-ET
5kW

4
GW20K-ET
6.7kW

5
GW25K-ET
8.3kW

6
GW29.9K-ET
10kW

7
GW30K-ET
10kW

load control
The inverter's dry contact control port supports connecting additional contactors to 
control the switching on or off of loads. It supports household loads, heat pumps, 
etc.
The load control methods are as follows:

Time control: Set the time to switch the load on or off. The load will automatically 
turn on or off within the set time period.
•

Switch control: When the control mode is set to ON, the load will turn on; when set 
to OFF, the load will turn off.
•

•

BACK-UP Loads control: The inverter has a built-in relay dry contact control port, 
which can control whether the load is switched off via the relay. In off-grid mode, if 
an overload is detected on the BACK-UP port and the battery SOC value falls below 
the off-grid protection setting, the load connected to the relay port can be 
switched off.

Rapid Shutdown(RSD)

In a rapid shutdown system, the rapid shutdown transmitter and receiver work 
together to achieve rapid system shutdown. The receiver maintains module output 
by receiving signals from the transmitter. The transmitter can be external or built 
into the inverter. In an emergency, by enabling an external triggering device, the 
transmitter can be deactivated, thereby shutting down the modules.

63

Sayfa 65

•

External Transmitter

Transmitter Models: GTP-F2L-20, GTP-F2M-20
https://en.goodwe.com/Ftp/Installation-instructions/RSD2.0-transmitter.pdf

○

Receiver Models: GR-B1F-20, GR-B2F-20
https://en.goodwe.com/Ftp/EN/Downloads/User%20Manual/GW_RSD-20_Quick-
Installation-Guide-POLY.pdf

○

•

Built-in Transmitter

External Triggering Device: External switch
○

Receiver Models: GR-B1F-20, GR-B2F-20
https://en.goodwe.com/Ftp/EN/Downloads/User%20Manual/GW_RSD-20_Quick-
Installation-Guide-POLY.pdf

○

64

Sayfa 66

3 Check and Storage

3.1 Check Before Receiving

Before receiving the product, please carefully check the following:

1. 

Check if the outer packaging is damaged, such as deformation, holes, cracks, or 
other signs that might cause damage to the equipment inside the packaging. If 
damaged, do not open the packaging and contact your dealer.

Check if the device model is correct. If it does not match, do not open the 
packaging and contact your dealer.
2. 

3.2 deliverables

WARNING

Check if the type and quantity of the delivered items are correct and if there is any 
damage to their appearance. If damaged, please contact your dealer.
After removing delivered items from the packaging, do not place them on rough, 
uneven, or sharp surfaces to avoid paint chipping.

3.2.1 Inverter Deliverables

Part
Description
Part
Description

Inverter x 1
Backplate x 1

Wall-mounting 
fastening screws 
x 2

65

PV connector
GW12KL-ET, GW15K-
ET, GW20K-ET: 4
GW18KL-ET, GW25K-
ET, GW29.9K-ET, 
GW30K-ET: 6

Sayfa 67

Part
Description
Part
Description

PV wiring tool
 x 1

6PIN 
communication 
terminal x 1

Protective PE 
screw x 1

Grounding 
terminal x 1

7PIN communication 
terminal x 1

3PIN communication 
terminal x 1

PIN terminal x N
The quantity of PIN 
terminals provided 
with the box varies 
depending on the 
inverter configuration. 
Please refer to the 
actual shipment.

BMS/Meter 
Communication cable
GW12KL-ET, GW15K-
ET, GW20K-ET: 2
GW18KL-ET, GW25K-
ET, GW29.9K-ET, 

GW30K-ET: 3

Expansion bolt x 6

66

Sayfa 68

Part
Description
Part
Description

Please refer to 
the actual 
shipment

OT terminal x 
12
•

AC terminal 
flange nut x 20
•

•

Insulation 
board for AC 
terminal x 1

or

•

AC terminal 
protective 
cover x 1

or

Hexagon 
screwdriverx 1
•

screwdriver x 1

or
smart dongle x 1

Product 
documentation x 
1

(Optional)
Wiring tool x 1
Battery connector:
GW12KL-ET, GW15K-ET, GW20K-ET: 1
GW18KL-ET, GW25K-ET, GW29.9K-ET, GW30K-ET: 2

Wiring tool

Battery 
connector

67

Smart meter and 
accessories x 1
Please refer to the 
actual shipment

Sayfa 69

Part
Description
Part
Description

Wiring tool

(Optional)
Wiring tool x 2
Hexagon screwdriverx 1
Battery connector:
GW12KL-ET, GW15K-ET, GW20K-ET: 1
GW18KL-ET, GW25K-ET, GW29.9K-ET, GW30K-ET: 2

Hexagon 
screwdriver

Battery 
connector

Part
Description
Part
Description

cable tie x 10
expansion bolt x 4

M5 hex screw x 10
M5 nut x 5

Right side panel of 
protective cover x 1

Bottom panel of 
protective cover x 1

Table39 Protective Cover Accessory (Australia Only)

3.2.2 Batteries Deliverables

3.2.2.1 Lynx C Series 60kWh Industrial & Commercial Battery System

68

Left side panel of 
protective cover x 1

Front cover panel of 
protective cover x 1

Sayfa 70

Component
Quantity
Component
Quantity

Battery system x 1 
GW60KWH-D-10: 
Includes AC cabinet 
GW60KWH-D-10 
(without extension 
cabinet): Does not 
include AC cabinet

 or 

69

•

Battery-to-
battery 
connection 
aluminum 
busbar 
When all busbars 
are shipped with 
accessories, the 
quantity in 
accessories is 10

•

When some 
busbars are 
shipped with 
accessories, the 
quantity in 
accessories is 3 
(other busbars 
are pre-installed 
on the battery)

Sayfa 71

Component
Quantity
Component
Quantity

Battery-to-high 
voltage box 
connection aluminum 
busbar 

•

When the busbar is 
shipped with 
accessories, the 
quantity in 
accessories is 1

•

When the busbar is 
pre-installed on the 
battery for 
shipment, the 
quantity in 
accessories is 0

Battery-to-battery 
fixing screw

•

When all busbars 
are shipped with 
accessories, the 
quantity of screws 
in accessories is 22

•
Lifting ring x 4

When some 
busbars are 
shipped with 
accessories, the 
quantity of screws 
in accessories is 6

Inverter Back-up 
terminal block x 5

70

Battery-to-high 
voltage box fixing 
screw x 2

M12 waterproof 
component x 2

Sayfa 72

Component
Quantity
Component
Quantity

M18 waterproof 
component x 2

M22 waterproof 
component x 4
cable tie x 10

Inverter-to-high 
voltage box power 
cable 
GW60KWH-D-10 
(without extension 
cabinet): 0 
GW60KWH-D-10: 1

Expansion screw x 4

Air conditioning 
water pipe x 1
M5 nut x 9

71

M20 waterproof 
component x 2

Inverter battery 
terminal block 
GW60KWH-D-10 
(without extension 
cabinet): 0 
GW60KWH-D-10: N 
N: Please refer to 
the actual product 
shipment

High voltage box 
power terminal 
block 
GW60KWH-D-10 
(without extension 
cabinet): 2 
GW60KWH-D-10: 1

Sayfa 73

Component
Quantity
Component
Quantity

Grounding terminal x 
1

Product 
documentation x 1

Wrench x 0: Fire 
department has "Do 
Not Touch" label 
Wrench x 1: Other

3.2.2.2 BAT-S Series 15.3-56.3kWh High Voltage Battery

Supported configurations and installation plans vary by region. For details, please 
contact sales.

Battery Pack

Inverter-to-high 
voltage box 
communication 
cable 
GW60KWH-D-10: 1 
GW60KWH-D-10 
(without extension 
cabinet): 0

Terminating 
resistor x 2 
GW60KWH-D-10 
(without extension 
cabinet): 1 
GW60KWH-D-10: 0

-
-

NOTICE

72

Sayfa 74

Component
Description

Stacked Installation

Rack Installation

PCU

Part
Description

Stack Installation

Rack Installation

Accessories

Stack Mounting
•

Battery PACK

GW15.3-BAT-I-G10:× 3
•

GW20.4-BAT-I-G10:× 4
•

GW25.6-BAT-I-G10:× 5
•

GW30.7-BAT-I-G10:× 6
•

GW35.8-BAT-I-G10:× 7
•

GW40.9-BAT-I-G10:× 8
•

GW46.0-BAT-I-G10:× 9
•

GW51.2-BAT-I-G10:× 10
•

GW56.3-BAT-I-G10:× 11
•

PCU × 1

73

Sayfa 75

Part
Description
Part
Description

Ground lock 
bracket×4

Equipotential 
bonding strip×15
M5 screw×N

Cable gland×1
Expansion bolt×8

Adjustable foot×4
Base×1

Power 
connector×2

B- power cable×1
B+ power cable×1

Internal battery 
power cable ×N

Grounding 
terminal ×2

74

Wall lock 
bracket×4

Battery to 
inverter 
communication 
cable×1

Internal battery 
communication 
cable ×N

M12 expansion 
bolt ×4

Sayfa 76

Part
Description
Part
Description

Nameplate×1
Cable tie×10

adapter 
bonnet×4 
(Included only for 
units shipped 
after April 3, 
2026)

Rack Mounting
•

Part
Description
Part
Description

Battery Rack ×1
Rubber Pad×4

M5 screw×N
ST6.3 screw×4

Adjustable Feet×4
Wall Mounting 
Bracket×2

Power Connector×2

B- Power Cable×1
B+ Power Cable×1

75

Product 
documentation×1

Battery to Inverter 
Communication 
Cable×1

Sayfa 77

Part
Description
Part
Description

Internal Battery 
Power Cable×N

Grounding 
terminal×2

Nameplate×1
Cable Tie×10

adapter bonnet×1
Product 
Documentation×1

3.2.2.3 BAT Series 61.4-112.6kWh Industrial & Commercial Battery System

Component
Description
Component
Description

battery cabinet×1
Expansion screw×4

Grounding M5 screw×3
Grounding 
terminal×3

Inverter battery connection 
terminal 25mm²×2

76

Internal Battery 
Communication 
Cable×N

M12 Expansion 
Bolt×4

Inter-battery 
connection 
terminal 50mm²×2

Sayfa 78

Component
Description
Component
Description

Pack series wiring harness×N

GW61.4-BAT-AC-G10:×5
•

GW92.1-BAT-AC-G10:×8
•

GW102.4-BAT-AC-G10:×9
•

GW112.6-BAT-AC-G10:×10
•

Inverter battery connection 
(positive)×1
Inverter battery connection 
(negative)×1

Battery to inverter 
communication network 
cable×1

Lifting ring×4
Cable tie×20

Air conditioner water pipe 
kit×1
fireproofing mud×8

Corrugated pipe connector×6

Product documentation×1
-
-

3.2.3 Smart Meter Deliverables (GM3000)

Part
Quantity
Part
Quantity

Pack negative to 
high-voltage box 
negative wiring 
harness×1

Adapter bracket×2
(Required for ET100 
only)

Air conditioner 
power supply 
wiring harness 
kit×1

25mm² to 10mm² 
round tube 
terminal×4

77

Sayfa 79

Smart meter 
and CT x 1

2PIN terminal and 
RJ45 terminal adapter 
cable x 1
PIN terminal x 3
USB plug x 1

screwdriver x 1
Product 
documentation x 1

3.2.4 Smart Meter Deliverables GM330&GMK330

3.2.4.1 Attachment List

Component
Description
Component
Description

Smart Meter x1
GMK330: CT×3; 
GMK360: CT×6; 
GM330: CT x 0.

6PIN 
Communication 
Terminal x1
For GM330.

Meter 
Communication 
Terminal

For 
GMK330/GMK360.

2PIN Terminal to 
RJ45 Terminal 
Adapter Cable x 1

2PIN Communication 
Terminal x1
For GM330.

7PIN Communication 
Terminal x1
For GM330.

 
RS485 Communication 
Terminal x 1

screwdriver x1

78

Sayfa 80

Component
Description
Component
Description

PIN terminal
GMK330/GMK360: x 
5 ; GM330: x 6.

3.3 Storage

[1] Storage time is calculated from the SN date on the battery outer packaging. 
After exceeding the storage cycle, charging and discharging maintenance is 
required. (Battery maintenance time = SN date + charging and discharging 
maintenance cycle). For the method to view the SN date, refer to: 10.4.SN Code 
Meaning(Page 320).
[2] After charging and discharging maintenance is qualified, if there is a 
Maintaining Label on the outer box, please update the maintenance information 
on the Maintaining Label. If there is no Maintaining Label, please record the 
maintenance time and battery SOC yourself and keep the data properly to facilitate 
the preservation of maintenance records.

If the device is not put into use immediately, please store it according to the 
following requirements. After long-term storage, the device must be inspected and 
confirmed by professionals before it can be used.

1. 

If the inverter is stored for more than two years or not operated for more than 6 
months after installation, it is recommended to have it inspected and tested by 
professionals before putting it into use.

2. 

To ensure the good electrical performance of the internal electronic components 
of the inverter, it is recommended to power it on every 6 months during storage. If 
it has not been powered on for more than 6 months, it is recommended to have it 
inspected and tested by professionals before putting it into use.

3. 

To protect battery performance and service life, it is recommended to avoid long-
term idle storage. Prolonged storage may cause deep discharge of the battery, 
leading to irreversible chemical loss, capacity attenuation, or even complete failure. 
It is advised to use it promptly. If the battery needs long-term storage, please 
maintain it according to the following requirements:

Product Documentation 
x 1

NOTICE

79

Sayfa 81

Recomm
ended 
Storage 
Tempera
ture

Battery 
Storage Initial 
SOC Range

Charge/Discharge 
Maintenance 
Cycle[1]

Battery

Lynx C  Series 
60kWh  
Commercial & 
Industrial 
Battery System

-20~0℃, ≤1 month

30%~40%
0~35℃

0~+35℃, ≤6 months

35~+45℃, ≤1 month

BAT-S Series 
15.3-56.3kWh 
High Voltage 
Battery

-20~35℃ (≤12 

30%~40%
0~35℃

months)
35~+45℃ (≤6 months)

BAT-C Series 
61.4-112.6kWh   
Commercial & 
Industrial 
Battery System

Packaging Requirements: 
Ensure that the outer packaging box is not removed and the desiccant inside the box 
is not lost.
 

Environmental Requirements:

Ensure that the device is stored in a cool place, avoiding direct sunlight.
1. 

2. 

Ensure the storage environment is clean, with appropriate temperature and 
humidity ranges, and no condensation. If there is condensation on the device 
ports, do not install the device.

Ensure that the device is stored away from flammable, explosive, corrosive, and 
other hazardous materials.
3. 

 
Stacking Requirements:

Ensure that the stacking height and direction of the inverters are arranged 
according to the instructions on the packaging box labels.
1. 

80

Battery 
Maintena
nce 
Method[2]

Please 
consult 
the dealer 
or after-
sales 
service 
center for 
the 
maintena
nce 
method.

Sayfa 82

Ensure that there is no risk of tipping after the inverters are stacked.
2. 

81

Sayfa 83

4 Installation

When performing equipment installation and electrical connections, please use the 
components delivered with the shipment. Otherwise, any resulting equipment 
damage will not be covered by the warranty.

4.1 System Installation and Commissioning 
Procedure

DANGER

82

Sayfa 84

4.2 Installation Requirements

4.2.1 Installation Environment Requirements

If installed in an environment below 0°C, the battery will be unable to recharge and 
restore energy after being depleted, resulting in battery undervoltage protection. 
GW60KWH-D-10:Charging temperature range: 0<T<55°C;Discharging temperature 
range: -25<T<55°C

The equipment must not be installed in flammable, explosive, corrosive, or similar 
environments.
1. 

The temperature and humidity of the equipment installation environment must be 
within a suitable range.
2. 

The installation location must be out of reach of children and avoid easily 
accessible positions.
3. 

During Inverter operation, the enclosure temperature may exceed 60°C. Do not 
touch the enclosure before it cools down to prevent burns.
4. 

The Inverter should be installed in a location sheltered from direct sunlight, rain, 
5. 

NOTICE

83

Sayfa 85

snow accumulation, etc. It is recommended to install it in a covered position; a 
sunshade can be constructed if necessary.
Adverse environmental conditions such as direct sunlight and high temperatures 
may cause the Inverter output power to be derated.
6. 

The installation space must meet the equipment's ventilation, heat dissipation, and 
operational space requirements.
7. 

8. 

The installation environment must satisfy the equipment's protection rating.

Inverters and Smart Communication Sticks are suitable for both indoor and 
outdoor installation;
•

Electricity meters are suitable for indoor installation;
•

•

Lynx C Series 60kWh Commercial & Industrial Battery System and BAT-C Series 
61.4-112.6kWh Commercial & Industrial Battery System are suitable for indoor 
and outdoor installation. The BAT-S Series 15.3-56.3kWh High Voltage Battery is 
suitable for indoor installation and must be kept ventilated.

When installing equipment indoors, ensure there are no obstacles within a 10-
meter diameter of the installation location.
9. 

During construction and installation, ensure the bottom of the equipment is higher 
than the local historical highest water level.
10. 

11. 

The installation height of the equipment should facilitate operation and 
maintenance, ensuring the equipment indicator lights, all labels are easily 
viewable, and the wiring terminals are easily accessible.

The installation altitude of the equipment must be below the maximum operating 
altitude.
12. 

13. 

The battery system must be installed on a flat, dry ground surface. It must not be 
placed in a recessed or sloped area and is strictly prohibited from being installed 
on ground prone to water accumulation or sinking. Ensure the ground can bear 
the weight of the battery system.

14. 

Before installing equipment outdoors in salt damage areas, consult the equipment 
manufacturer. Salt damage areas mainly refer to regions within 500m of the 
coastline. The affected area is related to sea wind, precipitation, terrain, etc.

15. 

Keep away from strong magnetic field environments to avoid electromagnetic 
interference. If there are radio stations or wireless communication equipment 
operating below 30MHz near the installation location, install the equipment 
according to the following requirements:

•

Inverter: Add a ferrite core with multiple windings on the Inverter's DC input or 
AC output lines, or add a low-pass EMI filter; OR the distance between the 
Inverter and the wireless electromagnetic interference source should exceed 
30m.

Other equipment: The distance between the equipment and the wireless 
•

84

Sayfa 86

electromagnetic interference source should exceed 30m.
The length of DC and communication cables between the battery and the Inverter 
must be less than 3m. Please ensure the installation distance between the Inverter 
and the battery meets the cable length requirement.

16. 

85

Sayfa 87

4.2.2 Foundation Installation Requirements

The foundation material must be C25 plain concrete hardened ground or other 
1. 

86

Sayfa 88

non-combustible surfaces.
The foundation must have pre-reserved trenches or cable outlets to facilitate 
equipment cabling.
2. 

Equipment (including height, embedded expansion screw parts, conduits, etc.) 
should be adjusted according to the process and on-site conditions.
3. 

The top elevation of the equipment foundation can be adjusted according to the 
equipment and actual on-site requirements.
4. 

Ensure the equipment is installed level and must not be tilted or inverted.
5. 

6. 

Trench Requirements:

If the equipment uses bottom cable entry, the trench must have a dust-proof 
and rodent-proof design to prevent foreign objects from entering.
•

•

The trench must have a waterproof and moisture-proof design to prevent cable 
aging and short circuits, which could affect the normal operation of the 
equipment.

•

As the equipment cables are relatively thick, sufficient space for the cables must 
be reserved in the trench design to ensure smooth and unworn cable 
connections.

The conduit may be replaced with four 125mm-diameter PVC pipes on-site. Conduit 
does not need to be pre-installed for indoor environments.

NOTICE

87

Sayfa 89

4.2.3 Installation Space Requirements

When installing devices in the system, sufficient space should be reserved around the 
devices to ensure adequate installation and heat dissipation space.

The specific numerical values for battery installation space can be adjusted based 
on the actual installation scenario and local regulations.

NOTICE

88

Sayfa 90

BAT 61.4-112.6kWh C&I
BAT 15.3-56.3kWh HV

Sayfa 91

4.2.4 Tool Requirements

During installation, it is recommended to use the following installation tools. If 
necessary, other auxiliary tools can be used on-site.

Installation Tools

Tool Type
Description
Tool Type
Description

diagonal plier
RJ45 connector 
crimping tool

wire stripper
YQK-70 hydraulic pliers

VXC9 hydraulic 
pliers
Level bar

open-end wrench

hammer drill (drill 
bit Φ8mm)

rubber hammer
socket wrench

NOTICE

PV terminal crimping 
tool
PV-CZM-61100

torque wrench
M5/M6/M8/M12/M16/
M18/M22

90

Sayfa 92

Tool Type
Description
Tool Type
Description

marker pen
multimeter
range ≤1100V

heat shrink tubing
heat gun

cable tie
vacuum cleaner

Level bar
 
 

Personal Protective Equipment

Tool Type
Description
Tool Type
Description

Insulated gloves, 
protective gloves

Goggle
Safety shoes

4.3 Equipment Handling

Dust mask

91

Sayfa 93

1. 

When performing operations such as transportation, turnover, and installation, it 
must comply with the laws, regulations, and relevant standard requirements of 
the country or region.

2. 

Before installation, the equipment needs to be moved to the installation site. To 
avoid personal injury or equipment damage during the moving process, please 
note the following:

•

Please assign personnel according to the weight of the equipment to prevent 
the equipment from exceeding the weight range that can be manually carried, 
which could cause injury.

Please wear safety gloves to avoid injury.
•

Please ensure that the equipment remains balanced during the moving 
process to avoid dropping and tipping over.
•

During the moving process, please ensure that the cabinet doors are locked.
•

The equipment can be transported to the installation site using hoisting or a 
forklift.
•

When using hoisting to move the equipment, please use flexible slings or lifting 
belts, with a single belt's load-bearing capacity ≥2t.
•

When using a forklift to move the equipment, the forklift's load-bearing capacity 
must be ≥2t.
•

Lynx C Series 60kWh Commercial & Industrial Battery System
•

Forklift Transport Method One

WARNING

NOTICE

92

Sayfa 94

Forklift Transport Method Two

Hoisting Transport:

93

Sayfa 95

BAT-SSeries 15.3-56.3kWh High Voltage Battery
•

BAT-CSeries 61.4-112.6kWh Commercial & Industrial Battery System
•

Remove the baffles before using a forklift to move the equipment.
•

The battery system is secured to the pallet with bottom screws during shipment. 
Please remove the pallet before installation.
•

NOTICE

94

Sayfa 96

4.4 Installing the Inverter

Installing the Inverter in the Battery System Cabinet

Ensure that the inverter is installed securely to prevent it from falling and injuring 
people.

Secure the inverter backplate bracket to the battery system cabinet.
1. 

2. 

(Optional) Use a DC switch lock to lock the DC switch in the “OFF” position, and 
hang the inverter on the backplate. The DC switch lock is user-provided; please 
ensure the aperture of the DC switch lock meets the requirements.

Tighten the screws on both sides to secure the backplate and inverter, ensuring 
the inverter is installed firmly.
3. 

CAUTION

95

Sayfa 97

Installing the Inverter on the Wall

When drilling holes, ensure the drilling location avoids water pipes, cables, etc., 
inside the wall to prevent danger.
•

When drilling, please wear safety goggles and a dust mask to avoid inhaling dust 
into the respiratory tract or getting it in the eyes.
•

Ensure the inverter is installed securely to prevent it from falling and injuring 
personnel.
•

Place the backplate horizontally on the wall, and use a marker to mark the drilling 
positions.
1. 

Use an impact drill to drill holes.
2. 

Use expansion screws to secure the inverter backplate bracket to the wall.
3. 

4. 

Use a DC switch lock to lock the DC switch in the “OFF” position, and hang the 
inverter on the backplate. (Optional) For Australia only, the DC switch lock is user-
provided; please ensure the aperture of the DC switch lock meets the 
requirements.

CAUTION

96

Sayfa 98

(Optional) Lower the handle.
5. 

Tighten the screws on both sides to secure the backplate and inverter, ensuring 
the inverter is installed firmly.
6. 

Installing the Protective Cover (Australia Only)

97

Sayfa 99

Step1: Assemble the protective cover.
Step2: Install the front cover plate.
Step3: Secure the protective cover to the wall/side of the battery cabinet, and install 
the circuit breaker, waterproof box, and cable tray according to local regulations. For 
specific requirements, refer to the table below.

Equipment
Recommended 
Model/Specifications
Description

break

er

Select according to 
local laws and 
regulations

2P DC switch
•

User to provide.

Rated Current ≥63A
•

Nominal Voltage 
≥1000V
•

98

Sayfa 100

Equipment
Recommended 
Model/Specifications
Description

Water

proof 

Box

Cable 

Tray

4.5 Installing the Battery System

Check that the ground is level and not sloped before installation.
•

Ensure the energy storage system is vertical and flush against the ground, with 
no risk of tipping.
•

4.5.1 Open the Cabinet Door

User to provide.
If the hole spacing of the 
waterproof box does not 
meet the requirements 
and cannot be fixed on 
the battery cabinet, 
please provide your own 
mounting plate. First, drill 
holes in the mounting 
plate according to the 
requirements and fix it 
on the battery cabinet, 
then fix the waterproof 
box on the mounting 
plate.

Waterproof rating > 
IP65
Hole spacing 
requirements:

Left-right hole 
spacing: 157mm
•

Up-down hole 
spacing: 318mm
•

Style and dimensions 
are for reference only

a: 250mm
b: 150mm
c: 510mm
Style for reference only

User to provide.

WARNING

99

Sayfa 101

Do not open the cabinet door during handling and installation.
•

Please close the cabinet door after system installation, wiring, and 
commissioning.
•

Step 1: Use the key to unlock the cabinet door. 
Step 2: Turn the door handle to open the cabinet door.

Lynx C Series 60kWh Commercial & Industrial Battery System
•

BAT Series 61.4-112.6kWh Commercial & Industrial Battery System
•

4.5.2 Installing the Lynx C Series 60kWh Commercial & Industrial 
Battery System

Step 1: Use a marker pen to mark the drilling positions on the level ground. 
Step 2: Use an impact drill with a 14mm diameter drill bit to create holes 

WARNING

100

Sayfa 102

approximately 80mm deep, and install expansion bolts. 
Step 3: Move the battery system to the hole positions and use a socket wrench to 
tighten the expansion bolts.

4.5.3 Installing BAT-S Series 15.3-56.3kWh High-Voltage Battery

Stack Installation
•

Step 1: Install adjustable feet under the base. The adjustable height range is 35-
45mm.
Step 2: Secure the floor-lock bracket onto the base.
Step 3: Use a pen to mark the drilling positions for expansion bolts on the floor.
Step 4: Install the expansion bolts.
Step 5: Secure the floor-lock bracket to the floor using the expansion bolts.
Step 6: Stack the battery PACKs. Pre-tighten the wall-lock brackets on the first and 
last battery PACK.
Step 7: Use a pen to mark the drilling positions for expansion bolts on the wall. 
Secure the wall-lock bracket with expansion bolts, then tighten the wall-lock bracket 
on the battery PACK.
Step 8: Place the high-voltage box.
Step 9: Install the equipotential bonding strap and the wire protection sleeve.
 

101

Sayfa 103

Battery Rack Installation
•

Installing the Battery Rack

Step1: Lay the bracket flat. Align all holes according to the serial number markings 
and secure them using M5 screws.
Step2: Position the rack vertically according to the arrow markings.

Securing the Battery Cabinet

Type I
○

102

Sayfa 104

Step3: Use a marker to mark the drilling positions for expansion bolts on the level 
floor.
Step4: Install the expansion bolts and secure the battery rack to the level floor using 
them.

Type II
○

Step3: Lay the rack horizontally and install adjustable feet on the bottom of the rack.
Step4: Position the rack vertically. Secure the rack to the wall using wall-lock 
brackets.

Installing the High-Voltage Box and Battery PACK

Step5: Slide the high-voltage box and battery PACKs into the rack in sequence, and 
attach the labels on the side of the rack.
Step6: Secure the high-voltage box and battery PACK using M5 screws.
 

103

Sayfa 105

1. 190mm
2. M5 4N·m
3. Type I /类型 I
4. M12 50N·m
BAT10INT0020

Sayfa 106

4.5.4 Installing BAT Series 61.4-112.6kWh Commercial & Industrial 
Battery System

Step 1: Secure the battery system to the foundation.

Mark the drilling positions according to the dimensions shown in the diagram.
1. 

Use an impact drill to create the holes and install expansion bolts.
2. 

105

Sayfa 107

Move the battery rack to the hole positions and fasten the batteries to the 
foundation using the expansion bolts.
3. 

Step 2: Remove the protective covers from the smoke and temperature sensor 
alarms. The smoke sensor and temperature sensor alarms are shipped with 

protective covers on the batteries. These covers must be removed for the alarms to 
function properly.
 

Step 3: Install the air conditioning drain pipe.

Install the air conditioning drain pipe connector.
1. 

Secure the air conditioning drain pipe to the connector.
2. 

106

Sayfa 108

4.6 Installing the Smart Meter

In areas with lightning danger, if the meter cable length exceeds 10m and the 
cable is not laid using grounded metal conduits, it is recommended to install 
external lightning protection devices.

GM3000

GM330&GMK330

WARNING

107

Sayfa 109

GMK10INT0003
108
GMK10INTOO03

108

Sayfa 110

5 System Wirings

The erection, routing, and connection of cables must comply with local laws, 
regulations, and standard requirements.
•

All operations during electrical connections, as well as the specifications of cables 
and components used, must meet local legal and regulatory requirements.
•

•

Before performing electrical connections, please disconnect the device's DC 
switch and AC output switch to ensure the device is powered off. Live working is 
strictly prohibited, otherwise it may lead to DANGER such as electric shock.

Cables of the same type should be bundled together and separated from cables 
of different types. It is prohibited to intertwine or cross-arrange them.
•

•

If the cable is subjected to excessive tension, it may lead to poor connections. 
When connecting, please leave a certain length of cable slack before connecting 
it to the inverter's terminal ports.

•

When crimping terminal lugs, ensure that the conductor part of the cable is in 
full contact with the terminal lug. Do not crimp the cable insulation together with 
the terminal lug. Otherwise, it may cause the device to fail to operate, or after 
operation, unreliable connections may lead to heating and damage to the 
inverter terminal block, among other conditions.

When performing electrical connections, wear personal protective equipment 
such as safety shoes, protective gloves, and insulating gloves as required.
•

Only qualified professionals are permitted to perform electrical connection 
operations.
•

The cable colors in the diagrams of this document are for reference only. Specific 
cable specifications must comply with local regulatory requirements.
•

For parallel systems, please adhere to the safety precautions in the user manuals 
corresponding to the related products within the system.
•

5.1 System Wiring Electrical Block Diagram

DANGER

NOTICE

109

Sayfa 111

•

Depending on regional regulatory requirements, the wiring methods for the N 
and PE lines of the inverter's ON-GRID and BACK-UP ports differ. Please comply 
with local regulations.

•

The inverter's ON-GRID AC port has a built-in relay. When the inverter is in off-
grid mode, the built-in ON-GRID relay is open; when the inverter is in grid-
connected mode, the built-in ON-GRID relay is closed.

•

When the inverter is powered on, the BACK-UP AC port is live. If maintenance on 
the BACK-UP Loads is required, please power down the inverter to avoid the risk 
of electric shock.

N and PE lines are connected together in the distribution box

•

To maintain neutral integrity, the neutral wires on the grid-connected side and 
the off-grid side must be connected together; otherwise, the off-grid function 
cannot operate normally.

The diagram below illustrates the grid system for regions such as Australia and 
New Zealand:
•

NOTICE

NOTICE

110

Sayfa 112

N and PE lines are separately wired in the distribution box

•

Ensure the protective earth wire for BACK-UP is correctly and securely connected; 
otherwise, the BACK-UP function may operate abnormally in the event of a grid 
fault.

The following wiring method applies to regions other than Australia, New 
Zealand, etc.:
•

NOTICE

111

Sayfa 113

5.2 Detailed System Wiring Diagram

When all loads in the photovoltaic system cannot consume the electricity generated 
by the system, the surplus power will be fed back into the grid. In this case, a smart 
meter or CT can be used to monitor the system's power generation and control the 

amount of electricity fed into the grid.

Connecting a smart meter enables the output power limit and load monitoring 
functions.
•

After connecting the smart meter, please enable the "Export power limit" function 
via the SolarGo App.
•

The Detailed System Wiring Diagram only shows wiring examples using some model 
devices. Please refer to the corresponding wiring instruction chapters based on the 
actual devices used for wiring.

112

Sayfa 114

•

In coupling scenarios, to implement grid-connected inverter power generation 
monitoring and load monitoring functions, dual-meter networking is required.

Meter 1 is used to monitor the system's grid-connected power.
○

Meter 2 is used to monitor the grid-connected inverter's power generation.
○

By integrating the data from Meter 1 and Meter 2, the monitoring platform can 
achieve real-time monitoring of load power consumption.

○

If the grid-connected inverter requires output power limitation, please connect a 
meter or CT device separately.
•

Meter 1 (Grid Side)
Meter 2 (Grid-tied Inverter AC Side)

GM3000
GM3000

GM3000
GM330

GM3000
GMK330

GM330
GM330

GM330
GM3000

GM330
GMK330

GMK330
GMK330

GMK330
GM3000

GMK330
GM330

Wiring diagram with protective cover (Australia only)

NOTICE

Dual Meter Configuration Scenarios

113

Sayfa 115

5.2.1 Detailed System Wiring Diagram for Single Inverter

General Scenarios
Scenario with GM3000

 
Scenario with GM330

114

Sayfa 116

 
Scenario with GMK330

115

Sayfa 117

 
Grid-tied Inverter Power Generation Monitoring and Load Monitoring 
Networking Solution for Coupled Scenarios
For output power limitation in coupled scenarios, please connect meters or CTs 
separately for the grid-tied inverter.
GM330 meter + GM330 meter

116

Sayfa 118

GMK330 meter + GMK330 meter

117

Sayfa 119

5.2.2 Detailed System Wiring Diagram for Parallel System

•

In a parallel system scenario, the inverter connected to the Ezlink3000 smart 
communication stick and the meter is the master inverter, while others are slave 
inverters. In the system, do not connect the smart communication stick to slave 
inverters.

•

If devices such as DRED, RCR, remote shutdown devices, NS Protection, SG Ready 
heat pumps, etc., need to be connected in the system, please connect them to the 
master inverter.

The following diagrams focus on wiring related to parallel systems. For other port 
wiring requirements, please refer to the single-unit system.
•

WithGM3000Scenario
 

118

Sayfa 120

WithGM330Scenario
 

WithGMK330Scenario

119

Sayfa 121

Coupling Scenario Load Monitoring and Grid-tied Inverter Power Generation 
Monitoring Networking Solution
GMK330 meter +GMK330 meter
 

120

Sayfa 122

5.3 Preparing Materials

121

Sayfa 123

Do not connect loads between the inverter and the AC switch directly connected 
to the inverter.
•

Each inverter must be equipped with an AC output circuit breaker. Multiple 
inverters must not be connected to a single AC circuit breaker simultaneously.
•

•

To ensure the inverter can be safely disconnected from the grid in case of an 
abnormality, please connect an AC circuit breaker on the AC side of the inverter. 
Select a suitable AC circuit breaker according to local regulations.

•

When the inverter is powered on, the BACK-UP AC port is live. If maintenance is 
required on the BACK-UP Loads, power down the inverter first, otherwise electric 
shock may occur.

•

For cables used within the same system, it is recommended that the following be 
consistent: conductor material, cross-sectional area, length, etc.

BACK-UP AC cable for each inverter
○

ON-GRID AC cable for each inverter
○

Power cable between the inverter and the battery
○

Power cable between batteries
○

•

The system only supports connecting a generator via an ATS  switch in a single-
unit scenario to achieve switching between grid and generator power supply. 
The ATS  switch is connected to the grid by default.

5.3.1 Preparing Breakers

WARNING

122

Sayfa 124

No.
breaker
Recommended Specifications

1
ON-GRID 
breaker

When the BACK-UP port is not loaded, the 
Rated Current requirements are as follows:

GW15K-ET: Rated Current ≥32A; Nominal 
Voltage ≥400V
•

GW20K-ET: Rated Current ≥40A; Nominal 
Voltage ≥400V
•

GW25K-ET: Rated Current ≥50A; Nominal 
Voltage ≥400V
•

GW29.9K-ET, GW30K-ET: Rated Current 
≥63A; Nominal Voltage ≥400V
•

GW12KL-ET: Rated Current ≥50A; 
Nominal Voltage ≥230V
•

GW18KL-ET: Rated Current ≥63A; 
Nominal Voltage ≥230V
•

When the BACK-UP port is loaded, the 
Rated Current requirements are as follows:

GW15K-ET: Rated Current ≥50A; Nominal 
Voltage ≥400V
•

•

GW20K-ET, GW25K-ET, GW29.9K-ET, 
GW30K-ET: Rated Current ≥63A; Nominal 
Voltage ≥400V

GW12KL-ET, GW18KL-ET: Rated Current 
≥63A; Nominal Voltage ≥230V
•

123

Acquisit
ion 
Method

Remark
s

Self-
provide
d

If the 
inverter'
s BACK-
UP port 
is not 
used, a 
suitable 
breaker 
can be 
selected 
based 
on the 
AC 
maximu
m 
output 
current.

Sayfa 125

No.
breaker
Recommended Specifications

Nominal Voltage ≥400V, Rated Current 

requirements are as follows:

GW15K-ET: Rated Current ≥32A; Nominal 
Voltage ≥400V
•

GW20K-ET: Rated Current ≥40A; Nominal 
Voltage ≥400V
•

2
BACK-UP 
breaker

GW25K-ET: Rated Current ≥50A; Nominal 
Voltage ≥400V
•

GW29.9K-ET, GW30K-ET: Rated Current 
≥63A; Nominal Voltage ≥400V
•

GW12KL-ET: Rated Current ≥40A; 
Nominal Voltage ≥230V
•

GW18KL-ET: Rated Current ≥63A; 
Nominal Voltage ≥230V
•

124

Acquisit
ion 
Method

Remark
s

Self-
provide
d

-

Sayfa 126

No.
breaker
Recommended Specifications

The ATS  switch for the same model has 
the same specifications as the ON-GRID  
breaker. Specification requirements 
(recommended):

GW15K-ET: Rated Current ≥32A;
•

3
ATS  
Switch

GW20K-ET: Rated Current ≥40A;
•

GW25K-ET: Rated Current ≥50A;
•

GW29.9K-ET, GW30K-ET: Rated Current 
≥63A;
•

GW12KL-ET: Rated Current ≥40A;
•

GW18KL-ET: Rated Current ≥63A;
•

Select according to local laws and 
regulations

4
Battery 
Switch

2P DC Switch
•

Rated Current ≥63A
•

Nominal Voltage ≥1000V
•

125

Acquisit
ion 
Method

Remark
s

During 
actual 
selectio
n, you 
can also 
choose 
a 
breaker 
that 
complie
s with 
local 
installati
on 
regulati
ons 
based 
on the 
actual 
operatin
g 
current.

Self-
provide
d

Self-
provide
d

-

Sayfa 127

No.
breaker
Recommended Specifications

Select according to local laws and 
regulations

Type A type
•

5
RCD

ON-GRID side: 300mA
•

BACK-UP side: 30mA
•

Nominal Voltage: 380V/400V
•

6
Meter 
Switch

Rated Current: 0.5A
•

5.3.2 Preparing Cables

No.
Cable
Recommended Specifications
Acquisition 
Method

Single-core outdoor copper cable
•

1
Inverter Protective 
Grounding Cable

Conductor cross-sectional area: 
6mm²-10mm²
•
Customer-
supplied

2
Customer-
supplied

Battery Protective 
Grounding Cable
Lynx C Series 
60kWh Commercial 

Single-core outdoor copper cable
•

Conductor cross-sectional area: 
6mm²
•

& Industrial Battery 
System

Battery Protective 
Grounding Cable
BAT-S Series 15.3-
56.3kWh High 
Voltage Battery

Single-core outdoor copper cable
•

Conductor cross-sectional area: 
10-16mm²
•

126

Acquisit
ion 
Method

Remark
s

Self-
provide
d

-

Self-
provide
d

-

Sayfa 128

No.
Cable
Recommended Specifications
Acquisition 
Method

Battery Protective 
Grounding Cable
BAT-C Series 61.4-
112.6kWh Commer
cial & Industrial 
Battery System

Single-core outdoor copper cable
•

Conductor cross-sectional area: 
16-25mm²
•

Industry-standard outdoor PV 
cable
•

Conductor cross-sectional area: 
4mm²-6mm²
•

3
PV DC Cable

Cable outer diameter: 5.9mm-
8.8mm
•

Terminal TypeI

Single-core outdoor copper cable
•

Conductor cross-sectional area: 
10mm²
•

Cable outer diameter: 6.5mm-
9.5mm
•

4
Battery DC Cable
Terminal Type Ⅱ

Single-core outdoor copper cable
•

Conductor cross-sectional area: 
10mm²
•

Cable outer diameter: 5mm-
8.5mm
•

127

Customer-
supplied

Included/ 
Customer-
supplied
 

Sayfa 129

No.
Cable
Recommended Specifications
Acquisition 
Method

5

Battery Cluster 
Power Cable
Lynx C  Series 
60kWh Commercial 
& Industrial Battery 
System

Single-core outdoor copper cable
•

Conductor cross-sectional area: 
32mm²-35mm²
•

Cable outer diameter: 10mm-
12mm
•

Battery Cluster 
Power Cable
BAT-S Series 15.3-

Single-core outdoor copper cable
•

Conductor cross-sectional area: 
25mm²
•

56.3kWh High 
Voltage Battery

Cable outer diameter: 9mm-
11mm
•

Multi-core outdoor copper cable
•

Conductor cross-sectional area: 
10mm²-16mm²
•

6
AC Cable

Cable outer diameter: 21mm-
26mm
•

Outdoor copper cable
Conductor cross-sectional area: 
1mm²

7
Smart Meter Power 
Cable

8
BatteryBMS 
Communication 
cable

-
Included

9
MeterRS485 
Communication 
cable

-

10
Battery Cluster 
Communication 
cable

CAT 5E or higher standard Ethernet 
cable and RJ45 connector

128

Customer-
supplied

Customer-
supplied

Customer-
supplied

Customer-
supplied

RJ45-2PIN terminal 

adapter cable and 

standard Ethernet 

cable, Included

Customer-
supplied

Sayfa 130

No.
Cable
Recommended Specifications
Acquisition 
Method

11
load controlDO 
Communication 
cable

Shielded cable meeting local 
standards
•

Conductor cross-sectional area: 
0.2mm²-0.3mm²
•

12
Remote Shutdown 
Communication 
cable

Cable outer diameter: 5mm-8mm
•

13
RCR/DRED Signal 
Cable

Customer-
supplied
14
Inverter Parallel 
Communication 
Cable

CAT 5E or higher standard Ethernet 
cable and RJ45 connector

EMS 
Communication 
cable/Charging Pile 
Communication 
cable

CAT 5E or higher standard Ethernet 
cable and RJ45 connector

15

Outdoor copper cable
•

16
12V External Power 
Supply

Conductor cross-sectional area: 
0.2mm²-0.3mm²
•

Cable outer diameter: 5mm-8mm
•

Air Conditioner 
Power Cable
Lynx C  Series 
60kWh Commercial 
& Industrial Battery 
System

-
Pre-installed

17
Air Conditioner 
Power Cable
BAT-C Series 61.4-
112.6kWh Commer
cial & Industrial 
Battery System

-
Included

129

Customer-
supplied

Customer-
supplied

Customer-
supplied

Customer-
supplied

Customer-
supplied

Sayfa 131

5.3.3 Removing the Baffle

Remove the baffle after the system installation is complete and before starting 
wiring.
•

After completing the system wiring, install the baffle to the enclosure.
•

Remove the bottom baffle

Inverter wiring area baffle

WARNING

130

Sayfa 132

5.4 Connecting the PE cable

131

Sayfa 133

•

The protective grounding of the chassis enclosure cannot replace the protective 
ground wire of the AC output port. When wiring, ensure the protective ground 
wires at both locations are reliably connected.

•

To improve the corrosion resistance of the terminal, it is recommended to apply 
silicone gel or paint to the exterior of the grounding terminal for protection after 
the protective ground wire connection installation is complete.

•

When installing the equipment, the protective ground wire must be installed 
first; when removing the equipment, the protective ground wire must be 
removed last.

5.4.1 Inverter Grounding

5.4.2 Battery System Grounding

Lynx C series 60kWh industrial and commercial battery system
•

Type 1

WARNING

132

Sayfa 134

Type 2

BAT-Sseries 15.3-56.3kWh high voltageBattery
•

BAT-Cseries 61.4-112.6kWh industrial and commercial battery system
•

5.5 Connecting the PV Cable

133

Sayfa 135

Do not connect the same PV string to multiple inverters, as this may cause 
inverter damage.
•

•

Before connecting the PV string to the inverter, verify the following information. 
Failure to do so may result in permanent inverter damage, and in severe cases, 
fire causing personal injury or property loss.

Ensure the maximum short-circuit current and maximum input voltage for 
each MPPT are within the inverter's allowable range.
1. 

Ensure the positive terminal of the PV string is connected to the inverter's PV+, 
and the negative terminal to the inverter's PV-.
2. 

•

The PV string output does not support grounding. Before connecting the PV 
string to the inverter, ensure the minimum insulation resistance to ground of the 
PV string meets the minimum insulation resistance requirement (R=Max. Input 
Voltage/30mA).

After completing the DC cable connection, ensure the cable connections are 
secure and not loose.
•

•

Use a multimeter to measure the positive and negative poles of the DC cable to 
ensure the positive and negative poles are correct without reverse polarity, and 
the voltage is within the allowable range.

Within each MPPT circuit, the two photovoltaic strings should use the same model, 
the same number of panels, and the same tilt and azimuth angles to ensure 
maximum efficiency.

DANGER

WARNING

NOTICE

134

Sayfa 136

5.6 Connecting Battery System Cables

Do not connect the same battery pack to multiple inverters, otherwise it may 
cause inverter damage.
•

It is prohibited to connect loads between the inverter and the battery.
•

When connecting battery cables, use insulated tools to prevent accidental electric 
shock or causing a battery short circuit.
•

Ensure that the battery open-circuit voltage is within the allowable range of the 
inverter.
•

•

Before connecting battery cables, confirm that the battery module and high-
voltage box are powered off, and the battery cluster switch and DC power supply 
switch are disconnected.

Between the inverter and the battery, choose whether to configure a DC switch 
according to local laws and regulations.
•

DANGER

135

Sayfa 137

•

Use a multimeter to measure the positive and negative poles of the DC cable, 
ensuring that the polarity is correct and not reversed; and the voltage is within 
the allowable range.

•

When wiring, ensure that the battery cables match the battery terminals 'BAT+', 
'BAT-', and grounding port exactly. If the cables are connected incorrectly, it may 
cause equipment damage.

Ensure that the wire core is fully inserted into the terminal connection hole, with 
no exposed parts.
•

•

Ensure that the cable connections are tight; otherwise, during equipment 
operation, it may cause the terminal to overheat and result in equipment 
damage.

Do not connect the same battery pack to multiple inverters; otherwise, it may 
cause inverter damage.
•

When a 25-30kW inverter is used with the BAT series 61.4kWh commercial & 
industrial battery system, connecting two BAT ports is required to achieve full load 
operation.

Battery System Wiring Diagram

Lynx C Series 60kWh Commercial & Industrial Battery System
•

WARNING

NOTICE

136

Sayfa 138

BAT-S Series 15.3-56.3kWh High Voltage Battery
•

137

Sayfa 139

BAT-C Series 61.4-112.6kWh Commercial & Industrial Battery System
•

138

Sayfa 140

5.6.1 Paired with Lynx C Series 60kWh Commercial & Industrial 
Battery System

5.6.1.1 Battery Wire Feedthrough Introduction

139

Sayfa 141

No.
Description
No.
Description

1
Battery power cable pass-

through hole

3
Communication cable pass-

through hole

5
Reserved pass-through hole
-
-

5.6.1.2 Connecting the Power Cable between the Inverter and Battery

2
Emergency stop button control cable 

pass-through hole

4
Air conditioning cable pass-through hole

140

Sayfa 142

•

Use a multimeter to measure the positive and negative poles of the DC cable to 
ensure correct polarity, with no reverse connection; and that the voltage is within 
the allowable range.

•

During wiring, ensure the battery cables match the "BAT+", "BAT-", and 
grounding ports on the battery terminals exactly. Incorrect cable connection will 
cause equipment damage.

Ensure the wire core is fully inserted into the terminal connection hole with no 
exposed part.
•

Ensure the cable connections are tight. Otherwise, during equipment operation, 
the terminal may overheat, causing equipment damage.
•

Do not connect the same battery bank to multiple inverters, as this may cause 
inverter damage.
•

•

The battery system comes with power cables for connecting to the inverter in the 
box.

If the inverter accessories include type one terminals, cut off the terminals on 
the power cable from the battery accessories that connect to the inverter, and 
use the battery connectors provided with the inverter to remake the power 
cable.

○

If the inverter accessories include type two terminals, you can directly use the 
power cable from the battery accessories.

○

If there are no terminals on the power cable from the battery accessories for 
connecting to the inverter, use the connectors from the inverter accessories to 
make the power cable.

○

Power cables for parallel clustering between battery systems need to be 
prepared by yourself.
•

Please connect the battery system to the BAT1 port of the inverter.
•

WARNING

NOTICE

141

Sayfa 143

Inverter End Cable Fabrication Method

142

Sayfa 144

Battery System Cluster Power Cable Fabrication Method

143

Sayfa 145

5.6.1.3 Connecting the Battery Communication Cable

Do not omit the battery system terminal resistor, otherwise communication 
between battery systems will fail.

•

The battery system is shipped with a BMS battery communication cable. It is 
recommended to use the provided cable. If the supplied communication cable 
does not meet the requirements, please prepare your own shielded network 
cable and shielded RJ45 connector.

Please connect the battery system to the BMS1 communication port of the 
inverter; otherwise, normal communication may not be possible.
•

•

The emergency stop switch communication cable is pre-installed on the cabinet. 
If the supplied communication cable does not meet the requirements, please 
prepare your own communication cable.

•

For parallel communication cables between battery systems, please prepare 
shielded network cables and shielded RJ45 connectors that meet the EIA/TIA-
568B standard.

•

PIN4 and PIN5 are only for connecting to the inverter communication. There is 
no need to crimp PIN4 and PIN5 for the parallel communication cables between 
battery systems.

When connecting battery systems in parallel, connect the inverter remote 
shutdown port to the main battery system.
•

WARNING

NOTICE

144

Sayfa 146

Explanation of BMS Communication Connection between Inverter and Battery:

Device
port
Definition
Description

4:CAN_H

5:CAN_L
CAN communication between the 
Inverter and the Battery

BMS1

Inverter

7:GND

Connected to the battery system to 
control the emergency shutdown of 
the battery

Remote 
Shutdown

8:Remote 

Shutdown

Battery

7:CAN_H

8:CAN_L
Parallel cluster CAN communication 
between batteries

Slave1

Master

1:RS485_A1

2:RS485_B1
Reserved for communication with 
the Inverter

145

Sayfa 147

Device
port
Definition
Description

4:CAN_H

5:CAN_L
Communication with the Inverter

7:CAN_H

8:CAN_L
Parallel cluster CAN communication 
between batteries

7:CAN_H

8:CAN_L
Parallel cluster CAN communication 
between batteries

Slave2

Connected to the Inverter to control 
the emergency shutdown of the 
battery

Emergency 
Stop Switch

1: NC
2: COM

5.6.1.4 Connecting Internal Power Busbars in Battery Systems

NOTICE

If the aluminum busbars in the battery system have been installed at the factory, 
please use tools to recheck the torque.

Scenario with partially installed inter-cell aluminum busbars before shipment:

Scenario with uninstalled inter-cell aluminum busbars before shipment:

146

Sayfa 148

5.6.1.5 Connecting Battery System AC Power Cables

•

The air conditioner power cord is pre-installed on the cabinet. If the provided 
power cord does not meet the requirements, please prepare an extension cable 
yourself.

It is recommended to connect the air conditioner power cord to the power 
distribution cabinet for power supply.
•

•

If the air conditioner needs to be used for emergency power supply, the air 
conditioner power cord can be connected to the inverter BACK UP side for 
power.

•

To ensure that the air conditioner can be safely disconnected from the power 
distribution cabinet in case of abnormalities, please install an AC switch between 
the air conditioner and the power distribution cabinet. The AC switch 
specification should be no less than 16A.

To ensure heat dissipation performance, do not arbitrarily modify the default 
temperature parameter settings of the air conditioner.
•

NOTICE

147

Sayfa 149

5.6.1.6 Connecting the Battery System Air Conditioning Drain Pipe

5.6.1.7 Open the Fire Switch

148

Sayfa 150

The "open" (turn on) and "close" (turn off) functions of the firefighting equipment 
can only be activated during professional maintenance or replacement of the 
temperature-sensitive activation component.

 
Scenario for operating the fire equipment switch:

If a 'Do Not Touch' tag is present, no action is required.
•

•

If no tag is present, please refer to the following steps to open the fire switch. Use 
a 14mm wrench to rotate the screw behind the pressure gauge counterclockwise 
approximately 1.5 turns until it is fully tightened, and the fire system will be 
successfully opened.

NOTICE

149

Sayfa 151

5.6.1.8 Install Baffle

After the cables are connected, install the bottom baffle.

150

Sayfa 152

5.6.2 Paired with BAT-S Series 15.3-56.3kWh High-Voltage Battery

Inverter
GW12KL
-ET

GW18KL
-ET

GW15K
-ET

GW20
K-ET

GW25
K-ET

GW29.9K
-ET

GW30K
-ET

Number of 
BAT Ports
1
2
1
1
2
2
2

Minimum 
PACKs 
Required for 
BAT-S Series 
Battery 
(Operational)

3PACK
3PACK
5PACK
5PACK
5PACK
5PACK
5PACK

Minimum 
PACKs 
Required for 
BAT-S Series 
Battery (Full 
Load)

5PACK
4PACK
6PACK
8PACK
5PACK
6PACK
6PACK

5.6.2.1 Connecting the Power Cable between the Inverter and Battery

NOTICE

The BAT-S series 15.3-56.3kWh high-voltage battery supports up to 6 battery 
cabinets in parallel.

Wiring Overview

The 15-20kW inverter has only one BAT port; connect one when used with a 
battery.
•

151

Sayfa 153

The 25-30kW inverter has two BAT ports; both need to be connected when used 
with a battery.
•

152

Sayfa 154

Inverter-end Cable Manufacturing Method

Battery-end Cable Manufacturing Method (Including Parallel Cluster Wiring)

153

Sayfa 155

5.6.2.2 Connecting Power Cables Between Batteries

5.6.2.3 Connecting Communication Cables

154

Sayfa 156

The battery system includes a communication cable with the package. Please use 
the included communication cable.

Instructions for BMS Communication Connection between Inverter and Battery:

port
Definition
Description

1: RS485_A1
2: RS485_B1
Communicate with inverter (reserved).    

 COM1, COM2 
4: CAN_H
5: CAN_L

Inverter to Battery Communication Wiring

NOTICE

Communicate with inverter or parallel 
cluster communication.

155

Sayfa 157

Communication Wiring between Battery PACKs

When connecting communication cables between battery PACKs, the COM OUT 
port of the bottommost PACK should not be connected, and there is no need to 
connect a terminal resistor!

5.6.3 BAT-C Series 61.4-112.6kWh Commercial & Industrial Battery 
System

Inverter
GW15K-
ET

Number of BAT Ports
1
1
2
2
2

NOTICE

GW20K-
ET

GW25K-
ET

GW29.9K-
ET

GW30K
-ET

156

Sayfa 158

Inverter
GW15K-
ET

GW20K-
ET

GW25K-
ET

GW29.9K-
ET

GW30K
-ET

With BAT 
61.4kWh 
Battery 
System

Connec
t to 2 
BAT 
ports

Connect 
to 1 BAT 
port

Connect 
to 1 BAT 
port

Connect 
to 2 BAT 
ports

Connect 
to 2 BAT 
ports

Wiring 
Method

Can it be 
fully loaded?
Yes
No
Yes
Yes
Yes

Connec
t to 2 
BAT 
ports

Connect 
to 1 BAT 
port

Connect 
to 1 BAT 
port

Connect 
to 2 BAT 
ports

Connect 
to 2 BAT 
ports

Wiring 
Method

With BAT 
92.1kWh 
Battery 
System
Can it be 
fully loaded?
Yes
Yes
Yes
Yes
Yes

Connec
t to 2 
BAT 
ports

Connect 
to 1 BAT 
port

Connect 
to 1 BAT 
port

Connect 
to 1 BAT 
port

Connect 
to 2 BAT 
ports

Wiring 
Method

With BAT 
102.4kWh 
Battery 
System
Can it be 
fully loaded?
Yes
Yes
Yes
Yes
Yes

Connec
t to 2 
BAT 
ports

Connect 
to 1 BAT 
port

Connect 
to 1 BAT 
port

Connect 
to 1 BAT 
port

Connect 
to 2 BAT 
ports

Wiring 
Method

With BAT 
112.6kWh 
Battery 
System
Can it be 
fully loaded?
Yes
Yes
Yes
Yes
Yes

5.6.3.1 Battery Wiring Port and System Wiring Introduction

WARNING

All cut wire holes must be sealed with fireproof putty.

157

Sayfa 159

5.6.3.3 Connecting the Battery Communication Cable

The battery system is shipped with a communication cable. Please use the 
communication cable provided in the package.
•

•

The external communication port of the battery system is pre-installed with a 
terminal resistor upon factory shipment. If you need to connect a communication 
cable, please remove the terminal resistor. Retain the terminal resistor on any 
port not connected to a communication cable.

NOTICE

158

Sayfa 160

Instructions for BMS Communication Connection Between Inverter and Battery:

Port
Definition
Description

1-3,6-8
-
-

4
CAN_H

5
CAN_L
Communicate with inverter

159

Sayfa 161

5.6.3.4 Connecting Battery Air Conditioning Cables

Wiring Steps: 
Step 1: Make the air conditioning cable. 
Step 2: Connect the cable to the air conditioning switch on the battery. 
Step 3: Connect the cable directly to the distribution board or to the inverter's 
BACKUP port via the distribution board.
 

Please ensure that the voltage of the air conditioner power cord is 220V±15%, and 
the rated current is 12A.

5.6.3.5 Install Base Plate and Release Emergency Stop Switch

After wiring is complete, please reinstall the battery bottom cover along the original 
path, and rotate right to release the emergency stop switch.

NOTICE

160

Sayfa 162

5.7 Connecting the AC Cable

•

The inverter internally integrates a Residual Current Monitoring Unit (RCMU) to 
prevent residual current from exceeding the specified value. When the inverter 
detects a leakage current greater than the allowable value, it will quickly 
disconnect from the grid or generator.

•

During wiring, ensure that the AC wires match the “L1”, “L2”, “L3”, “N”, and “PE” 
ports of the AC terminals exactly. If the cables are connected incorrectly, it may 
cause equipment damage.

Ensure that the wire cores are fully inserted into the terminal connection holes 
without exposure.
•

Ensure that the insulation plate at the AC terminals is tightly secured without 
looseness.
•

•

Ensure that the cable connections are tight; otherwise, during equipment 
operation, it may cause the terminal blocks to overheat and result in equipment 
damage.

Type one:

WARNING

161

Sayfa 163

Type two:

5.8 Connecting the Meter Cable

162

Sayfa 164

•

The meter shipped with the unit is for use with a single inverter only. Do not 
connect one meter to multiple inverters. If you have multiple inverters, please 
consult the manufacturer to purchase additional meters separately.

Ensure the CT connection direction and phase sequence are correct; otherwise, it 
may lead to incorrect monitoring data.
•

Ensure all cable connections are correct, secure, and not loose. Improper wiring 
may cause poor contact or damage the meter.
•

•

In areas with lightning risk, if the meter cable length exceeds 10m and the cable 
is not routed using a grounded metal conduit, it is recommended to install an 
external lightning protection device.

GM3000 Meter Wiring

The outer diameter of the AC power line must be smaller than the aperture of 
the CT to ensure the AC power line can pass through the CT.
•

To ensure the current detection accuracy of the CT, the recommended length of 
the CT cable does not exceed 30m.
•

Do not use network cable as the CT cable, as excessive current may cause 
damage to the meter.
•

•

The size and appearance of the CT provided by the equipment manufacturer may 
vary slightly depending on the model, but the installation and wiring methods 
are the same.

NOTICE

NOTICE

163

Sayfa 165

Wiring Steps

GM330&GMK330 Meter Wiring
 

164

Sayfa 166

©l)
i
IN}

08000008

'

[3 NE
== =
L<100m
7.RS485-B1 4 Sğeesro)
8.RS485-A1 = şe 8 İN Ly}
a (a) BL EO.
METER | | ET3010ELCOO17

GMK330

7.RS485-B1 ————— —
B.RS485-A1] _ = 5363 Öneş Mei

ET3010ELCO0026

Wiring Steps

165

Sayfa 167

Install CT (Type 1)

Install CT (Type 2)

166

Sayfa 168

5.9 Connecting the Inverter Communication Cable

•

To ensure the meter and CT can function properly, please ensure the following:

Ensure the CT is connected to the matching phase line: CT1 to L1, CT2 to L2, 
CT3 to L3.

○

Connect according to the direction indicated on the CT; otherwise, it may cause 
a CT reverse fault.

○

When replacing or maintaining the CT later, use the "Meter/CT - Auxiliary 
Detection" function in the SolarGo APP to allow the Inverter to readapt to the 
CT sampling current direction.

○

To use the DRED, RCR, or remote shutdown function, please enable this function 
in the SolarGo APP after wiring is completed.
•

•

If the Inverter is not connected to a DRED device or remote shutdown device, do 
not enable this function in the SolarGo APP; otherwise, the Inverter will not be 
able to operate in grid-connected mode.

In a parallel system, to implement DRED or RCR functions, only connect the 
DRED/RCR communication cable to the master Inverter.
•

The Inverter's DO signal communication port can connect to dry contact signals 
with specifications: Max≤24Vdc, 1A.
•

•

The Inverter supports connecting to a mobile phone or WEB interface via 4G, 
Bluetooth, WiFi, or LAN communication methods to set device parameters, view 
device operation information and error messages, and stay informed of the 
system status in a timely manner.

In a single-unit system, the installation of a WiFi/LAN Kit-20 or 4G Kit-CN-G20 
•

NOTICE

167

Sayfa 169

smart communication stick is supported.
In a parallel system, both the master and slave Inverters require the installation 
of a WiFi/LAN Kit-20 smart communication stick for networking.
•

•

When using the 4G Kit-CN-G20:

If parallel unit networking is required, please contact GoodWe to purchase the 
WiFi/LAN Kit-20.

○

In China, a standard Micro-SIM card is provided, with China Mobile as the 
carrier. Please confirm the device is installed in an area with carrier signal 
coverage. If local China Mobile signal is not covered, please contact the carrier 
to optimize the signal.

○

Supports connection to third-party monitoring platforms via the MQTT 
communication protocol.

○

The 4G Kit-CN-G20 is an LTE single-antenna device suitable for application 
scenarios with lower requirements for data transmission rates.
•

•

To use dual meters for grid-connected unit generation monitoring and load 
consumption monitoring, please use an RJ45  splitter for connection. Prepare the 
RJ45  splitter yourself or contact GoodWe to purchase one.

To maintain the Inverter's waterproof rating, do not remove the waterproof 
plugs from unused communication ports on the Inverter.
•

The Inverter's communication functions are optional; please select according to 
the actual usage scenario.
•

Type One

NOTICE

168

Sayfa 170

Type Two

169
Type Two

Slave inverter 1 Slave inverter n

İrt
EV Charger

CAT 5E and higer categories 2 [LRS485_A2)
CAT 5ERLAE .RS485 B2

Master inverter

12V Power supply
ov ikea |
Smart Meter/SREER METER

Remote Shutdown
G t / NS Protection
-B.d0-_]- 5 -Seperenor DERM
NS Protection

RJ45 5 4e88

Only for single

RJ45 Splitter ||7.RS485_B1 inverter/ (LERİN
Adapter 8.RS485 A1

Battery (CAN2) 4.CAN H
FB 3th (CAN2) 5.CAN_L

Battery (CAN1) 4.CAN H
FB te (CANI) 5.CAN L

When S1, S2, and W3 are disconnected at the
same time, the nominal output power is 100%.

RCR&ENWG 14a — S1,S2,W3 IETF, Bie İMLHYEEİN1000
(11 REF_1)

—w3>0%

—K4—>0%

—K 330% — s2 330%

—s1—60%

—K2—60%

—W4-EnWG 14a

—K1—100%

ET3010ELCO012

169

Sayfa 171

Only for single inverter/仅单机
EMS
充电桩
EV Charger
1.RS485-A
2.RS485-B
5.CAN-L
6.CAN-H
Slave inverter 1
从逆变器1
Slave inverter n
从逆变器n
n≤3
PAR
OFF
ON
1.LOAD-NO
3.LOAD-COM
4.DI-2
5.DI-1
BMS1
BMS2
Generator
发电机
Only for single inverter/仅单机
Battery (CAN2)
电池(CAN2)
4.CAN-H
5.CAN-L
Battery (CAN1)
电池(CAN1)
4.CAN-H
5.CAN-L
DRM
6 1/5
5 2/6
4 3/7
3 4/8
2 RG/0
1 CL/0
10R S5a
S5 S1
S6 S2
S7 S3
S8 S4
15K
RCR
(1 CL/0)
2 RG/0
3 4/8
4 3/7
5 2/6
6 1/5
K 4→0%
K 3→30%
K 2→60%
K 1→100%
RCR&EnWG 14a
(1 CL/0)
2 RG/0
3 4/8
4 3/7
5 2/6
6 1/5
W3→0%
S2→30%
S1→60%
W4→EnWG 14a
ET3010ELC0033

Sayfa 172

Silkscreen
Function
Description

DO / LOAD
load control(SG 
Ready)

GND 12V 
RSD
12V Power Supply
The inverter provides a 12V power supply port, 
supporting devices up to 5W. This port has 
short-circuit Protection Function.

Remote 
Shutdown/NS 
Protection

DI

•

Supports connection of dry contact signals 
to achieve functions like load control. The 
DO contact capacity is 24V DC@1A, NO/COM 
normally open contact.

•

Supports SG Ready heat pump connection, 
controlling the heat pump via dry contact 
signals.

•

Supported operating modes:

Operating mode 2 (Signal: 0:0 ): Energy-
saving Mode, in this mode, the heat pump 
operates in energy-saving mode.

○

Operating mode 3 (Signal: 0:1 ): Activation 
suggestion, in this mode, the heat pump 
increases hot water reserve to store heat 
while maintaining current operation.

○

Provides a signal control port for Remote 
Shutdown of the device or to implement NS 
Protection Function.
Remote Shutdown function:

Can control the device to stop working when 
an unexpected event occurs.
•

The remote shutdown device must be a 
normally closed type switch.
•

•

When the inverter uses the RCR or DRED 
function, ensure the remote shutdown 
device is connected, or the remote 
shutdown port is short-circuited.

171

Sayfa 173

Silkscreen
Function
Description

Generator 
Start/Stop Control 
Port

DO2 / GEN

RCR, DRED, or 
EnWG 14a 
Function 
Connection Port

DRM&RCR / 

EMS/PAR/PA
R-
1/PAR1&EM
S

•

EMS 
Communication 
or Charging Pile 
Communication 
Port

•

Parallel 
Communication 
Port

Only supports connection of generator 
control signals in single inverter scenarios.
•

•

The generator control mode is off by 
default, with the dry contact signal open; 
after enabling the control mode, the dry 
contact signal becomes shorted.

•

RCR  (Ripple Control Receiver): Provides an 
RCR signal control port to meet grid 
dispatch requirements in regions like 
Germany.

•

DRED  (Demand Response Enabling Device): 
Provides a DRED signal control port to meet 
DERD certification requirements in regions 
like Australia.

•

EnWG (Energy Industry Act) 14a: All 
controllable loads must accept emergency 
dimming from the grid. Grid operators can 
temporarily reduce the maximum grid 
purchase power of controllable loads to 
4.2kW.

•

CAN and BUS port: Parallel communication 
port. CAN communication is used to connect 
to other inverters in parallel networking; the 
BUS bus is used to control the on-grid/off-
grid status of each inverter in the parallel 
system.

•

RS485 port: Used to connect third-party EMS 
devices and charging piles. Connecting 
third-party EMS devices and charging piles is 
not supported in parallel scenarios.

172

Sayfa 174

Silkscreen
Function
Description
EMS/PAR / 
PAR1&EMS / 
 PAR2&EMS

Parallel 
Communication 
Port

S1
Parallel DIP Switch
Inverter parallel DIP switch, factory default is 
set to the ON position.
In multi-unit parallel scenarios, the parallel DIP 
switches of the first and last inverters must be 
set to the ON position, and the others to the 1 
position.

METER
Smart Meter 
Connection Port

Battery 
Communication 
Connection Port

BMS1 / 
BMS2

Method for Connecting the Communication Cable

•

CAN and BUS port: Parallel communication 
port. CAN communication is used to connect 
to other inverters in parallel networking; the 
BUS bus is used to control the on-grid/off-
grid status of each inverter in the parallel 
system.

Connects to a smart meter to achieve output 
power control, load monitoring, and other 
functions.

Connects to batteries using CAN 
communication.
GW12KL-ET, GW15K-ET, GW20K-ET: 1
GW18KL-ET, GW25K-ET, GW29.9K-ET, GW30K-
ET: 2

173

Sayfa 175

5.10 Connecting the Smart Communication Stick

174

Sayfa 176

•

The inverter supports connection via Bluetooth, 4G, WiFi, LAN smart dongle to a 
mobile phone or WEB interface for setting device parameters, viewing device 
operation information and error messages, and staying updated on system 
status.

When multiple inverters are networked in a system, the master inverter requires 
the installation of an Ezlink3000 smart dongle for networking.
•

For an energy storage system with a single inverter, you can use a WiFi-Kit, 
WiFi/LAN Kit-20, or 4G smart dongle.
•

When using the WiFi communication method to connect the inverter to a router, 
you can install a WiFi-Kit, WiFi/LAN Kit-20, or Ezlink3000 smart dongle.
•

When using the LAN communication method to connect the inverter to a router, 
you can install a WiFi/LAN Kit-20 or Ezlink3000 smart dongle.
•

•

When using the 4G communication method to upload energy storage system 
operation information to the monitoring platform, you can install an LS4G Kit-
CN, 4G Kit-CN, 4G Kit-CN-G20, or 4G Kit-CN-G21 smart dongle. When using LS4G 
Kit-CN or 4G Kit-CN, you need to use the smart dongle shipped with the inverter 
to configure the parameters of the energy storage system. After configuration is 
complete, replace it with the LS4G Kit-CN or 4G Kit-CN for data transmission. 
When using 4G Kit-CN-G20 or 4G Kit-CN-G21, please use the Bluetooth signal 
emitted by the module for local device configuration.

The 4G  module is an LTE single-antenna device, suitable for application 
scenarios with low data transmission rate requirements.
•

•

The built-in SIM card in the 4G  module is a mobile communication card. Please 
confirm whether the device is installed in an area covered by China Mobile's 4G 
signal.

•

After installing the 4G Kit-CN-G20 or 4G Kit-CN-G21 communication dongle, 
please contact the after-sales service center to bind the inverter with the 
communication dongle. After binding, if you need to install the communication 
dongle on another inverter, please contact the after-sales service center to 
unbind it first.

To ensure 4G signal communication quality, do not install the device indoors or 
in areas with metal interference signals.
•

NOTICE

175

Sayfa 177

ET3010ELC0034
ETSO010ELCO034

176

Sayfa 178

6 System Commissioning

6.1 Check Before Power ON

No.
Check Item

1
The equipment is installed securely, the installation location facilitates 
operation and maintenance, the installation space allows for ventilation and 
heat dissipation, and the installation environment is clean and tidy.

2
PE cable, DC cable, AC cable, Communication cable, and terminal resistor 
connections are correct and secure.

3
Cable bundling meets wiring requirements, is reasonably distributed, and 
shows no damage.

4
For unused cable entry holes and ports, ensure they are reliably connected 
using the terminals provided with the accessories and have been sealed.

5
Ensure used cable entry holes have been sealed.

6
The voltage and frequency at the inverter grid connection point meet the 
grid connection requirements.

6.2 Power ON

•

When multiple inverters are connected in parallel, ensure that the AC power is 
turned on for all slave inverters within one minute after the AC power is turned 
on for the master inverter.

•

When multiple battery systems are connected in a cluster, ensure that the QF2 
switches for all battery systems are closed within five minutes. 
When multiple battery systems are connected in a cluster, before closing QF1, 
ensure that the SolarGo App correctly displays the number of battery systems in 
the cluster; otherwise, it may cause damage to the battery system.

WARNING

177

Sayfa 179

When there is no PV power generation in the photovoltaic system and the grid is 
abnormal, if the inverter cannot operate normally, the battery black start function 
can be used to force the battery to discharge and start the inverter. The inverter 
can then enter off-grid mode, with the battery supplying power to the loads.

BAT series 92.1-112.6kWh  commercial & industrial battery system black start 
procedure, refer to the power on/off steps.
•

The black start procedure for other batteries is the same as the power-on steps.
•

BAT series 92.1-112.6kWh  commercial & industrial battery system: Before 
performing the power-on operation, ensure the battery's emergency stop switch is 
in the released state. Release procedure: Rotate the emergency stop switch to the 

right.

NOTICE

178

Sayfa 180

⑤ : Optional based on local laws and regulations.

6.3 Indicators

6.3.1 Inverter Indicators

Indicator
Status
Description
The inverter is powered on and in standby 
mode.

The inverter is starting up and in self-test mode.

The inverter is operating normally in grid-
connected power generation or off-grid mode.

BACK-UP output overload.

179

Sayfa 181

Indicator
Status
Description

6.3.2 Battery Indicators

Lynx C Series 60kWh Commercial & Industrial Battery System
•

indicato
r
Status
Description

Two green blinks: Device in standby
Run

System fault.

The inverter is powered off.

Grid abnormal, inverter BACK-UP port power 
supply normal.
Grid normal, inverter BACK-UP port power 
supply normal.

No power supply at the BACK-UP port.

Inverter monitoring module is resetting.

No connection established between the inverter 
and the communication terminal.
Communication failure between the 
communication terminal and the cloud server.

Inverter monitoring is normal.

Inverter monitoring module is not started.

Steady green: Device operating normally

Single green blink: Battery operating normally, not 

communicating with inverter

Green off, steady yellow: Device alarm

Green off, Steady red: Device fault

Green, yellow, and red all off: Device not powered on

180

Sayfa 182

indicato
r
Status
Description

Warning
Off: No device alarm

Fault
Off: No device fault

BAT-S Series 15.3-56.3kWh  High Voltage Battery
•

Indicator
Status
Description

Single green flash: Battery operating normally, 
not communicating with the inverter
RUN

Single red flash: System undervoltage level 3~4
FAULT

BAT-C Series 61.4-112.6kWh Commercial & Industrial Battery System
•

Steady on: Device alarm

Steady on: Device fault

Solid green light: Device operating normally

Two green flashes: Device in standby

Solid light: Device fault

Two red flashes: SN abnormality

181

Sayfa 183

Indicato

r
Status
Description

Double flash of green light: Device in standby
Run

Warning
Off: No device warning

Off: No device fault
Fault

6.3.3 Smart Meter Indicator

GM330&GMK330

Type
Status
Description

Power Light

Off
The meter is powered off
Off
Reserved
Communication 
Light

Steady green light: Device operating normally

Single flash of green light: Battery operating normally, not 

communicating with inverter

Green light off, steady yellow light: Device warning

Green light off, steady red: Device fault

Green, yellow, and red lights all off: Device not powered on

Steady light: Device warning

Steady light: Device fault

Single red flash: Sleep (under-voltage)

Constantly lit
The meter is powered on, no RS485 
communication

Flashing
The meter is powered on, RS485 
communication is normal

Flashing
Press the Reset button for ≥5s, Power Light and 
Buy/Sell Power Light flash: Meter reset

Constantly lit
buy power from the grid
Flashing
Selling power to the grid

182

Sayfa 184

Type
Status
Description

Buy/Sell Power 
Light
Off
Not buying or selling power

Reserved

GM3000

Type
Status
Description

Constantly lit
The meter is powered on
Power Light

Off
The meter is powered off

Constantly lit
buy power from the grid
Buy/Sell Light

Flashing
Selling power to the grid

Flashing
Normal communication

Communication 

Light

Flashes 5 times 
continuously

Off
No communication from the meter

6.3.4 Smart Dongle Indicator

Wi-Fi Kit 
•

Indicato
r
Color
State
Description

On
Wi-Fi Kit is powered on.
 
Green

Press the Reset button for <3s: Meter 
reset
•

•

Press the Reset button for 5s: Meter 
parameters restored to factory 
settings

•

Press the Reset button for >10s: Meter 
parameters restored to factory 
settings, and energy data cleared

183

Sayfa 185

Power 
indicato

r
Off
Wi-Fi Kit is not powered on or is 
rebooting.

On
WiFi AP hotspot is connected.
Commu
nication 
indicato

r
Blue
Off

WiFi/LAN Kit-20
•

•

After double-clicking the Reload button to turn on Bluetooth, the communication 
indicator will switch to a single-flash state. Please connect to the SolarGo APP 
within 5 minutes, otherwise Bluetooth will automatically turn off.

The single-flash state of the communication indicator only occurs after double-
clicking the Reload button to turn on Bluetooth.
•

Indicat

or
Status
Description

Steady on: The Smart Communication Stick is powered on.
Power 
Light

Commu
nication 
Light

Wi-Fi Kit communication is 
abnormal.
•

Wi-Fi Kit is rebooting.
•

NOTICE

Off: The Smart Communication Stick is not powered on.

Steady on: Communication is normal in WiFi mode or LAN 
mode.
Single flash: The Smart Communication Stick's Bluetooth 
signal is on, waiting to connect to the SolarGo app.
Double flash: The Smart Communication Stick has not 
connected to the router.

184

Sayfa 186

Indicat

or
Status
Description

Quadruple flash: The Smart Communication Stick 
communicates normally with the router but has not 
connected to the server.
Sextuple flash: The Smart Communication Stick is 
identifying connected devices.
Off: The Smart Communication Stick is undergoing a 
software reset or is not powered on.

Indicator
Color
Status
Description
Steady 
on
100Mbps wired network connection is normal.

The network cable is not connected.
•

Green

LAN port 
communica
tion light

100Mbps wired network connection is 
abnormal.
•

Off

10Mbps wired network connection is normal.
•

10/100Mbps wired network connection is normal, 
with no communication data being sent or 
received.
Flashin
g
Communication data is being sent or received.

Steady 
on

Yellow

Off
The network cable is not connected.

Button
Description
Hold for 0.5 to 3 seconds, the smart communication stick will reset.
Hold for 6 to 20 seconds, the smart communication stick will restore 
factory settings.
Reload

Quick double-click to enable Bluetooth signal (only lasts for 5 minutes).

4G Kit-CN-G20 & 4G Kit-CN-G21
•

Indicator
Status
Description

Steady on: The smart communication stick is 
powered on.

185

Sayfa 187

Indicator
Status
Description

Off: The smart communication stick is not powered 
on.
Steady on: The smart communication stick is 
connected to the server, communication is normal.
Double flash: The smart communication stick is not 
connected to the communication base station.
Quadruple flash: The smart communication stick is 
connected to the communication base station but 
not connected to the server.
Sextuple flash: Communication between the smart 
communication stick and the inverter is 
disconnected.
Off: The smart communication stick is undergoing a 
software reset or is not powered on.

Button
Description
Hold for 0.5~3 seconds, the Smart Communication Bar will restart.
RELOAD
Hold for 6~20 seconds, the Smart Communication Bar will restore 
factory settings.

LS4G Kit-CN, 4G Kit-CN
•

indicator
Color
Status
Description

On
Module is secured and powered on
Power 
Light

 
Green
Off
Module is not secured or not 
powered on

Blue

slow blinking (0.2s on, 
1.8s off)
Inverter communication light 2 
blinks: Dialing, searching for 
network

Communi

•

cation 
Light

•

Inverter communication light 4 
blinks: Connection to cloud failed 
due to no data flow

186

Sayfa 188

slow blinking (1.8s on, 
0.2s off)
Inverter communication light 2 
blinks: Dialing successful
•

fast blinking (0.125s 
on, 0.125s off)

Inverter is communicating with the 
cloud via the module
0.2s on, 8s off
SIM card not installed or poor SIM 
card contact

Ezlink3000
•

indicator/Sil

Color
Status
Description

kscreen

Power light
 

Blue

Green

Communicatio

n light

RELOAD
-
-
Short press for 1-3 seconds to restart the 

6.4 Close Cabinet Door

•

Inverter communication light 
steady on: Cloud connection 
successful

•

Inverter communication light 4 
blinks: Connection to cloud failed 
due to no data flow

Flashing: The communication stick is operating 

normally.

Off: The communication stick is powered off.

Steady on: The communication stick is connected 

to the server.

Double flash: The communication stick is not 

connected to the router.

Quadruple flash: The communication stick is 

connected to the router but not to the server.

communication stick.

Long press for 6-10 seconds to restore factory 

settings.

Quick double-click to enable Bluetooth signal 

(only lasts for 5 minutes).

187

Sayfa 189

Lynx C Series 60kWh Commercial & Industrial Battery System
•

BAT-CSeries 61.4-112.6kWh Commercial & Industrial Battery System
•

188

Sayfa 190

Front door
Back door
BAT10INT0007

Sayfa 191

7 System Debugging and Power Station 
Monitoring

7.1 Device debugging and power plant monitoring 
via SEMS+ App

SEMS+ App is a software for remote power plant monitoring or local device 
debugging. It supports installers or owners:

Remotely monitor the operation of the power plant and set the operation 
parameters of the power plant and devices.
•

Locally connect to devices, view device operation status, and set device 
parameters.
•

Download and Install SEMS+ App
Mobile phone requirements:

Mobile operating system requirements: Android 7.0 and above, iOS 15.1 and 
above.
•

Mobile phone supports a web browser and connects to the Internet.
•

Mobile phone supports WLAN/Bluetooth functionality.
•

 
Download methods:
Method 1:
Search for SEMS+ in Google Play, App Store, Huawei, Honor, Xiaomi, OPPO, vivo app 
stores to download and install.

Method 2:
Scan the QR code below to download and install.

190

Sayfa 192

 
For detailed functions, please refer to the SEMS+ App User Manual. The user manual 
can be obtained from the official website or by scanning the QR code below.

7.2 Device Debugging and Power Plant Monitoring 
via SEMS+ WEB

SEMS+ WEB is a monitoring platform that communicates via WiFi or LAN. The 
following are common functions of SEMS+ WEB:

Manage organization or user information, etc.
1. 

Add and monitor power plant information, etc.
2. 

Maintain devices.
3. 

For detailed functions, please refer to the SEMS+ WEB User Manual.

191

Sayfa 193

SEMS+ WEB User Manual

192

Sayfa 194

8 Maintenance

8.1 Power OFF the System

•

When performing operation or maintenance on equipment within the system, 
please power down the system. Operating equipment while energized may cause 
equipment damage or risk of electric shock.

•

After the equipment is powered off, internal components require a certain 
amount of time to discharge. Please wait according to the label's time 
requirement until the equipment is completely discharged.

Restarting the battery should be performed using the air switch power-on 
method.
•

When shutting down the battery system, strictly adhere to the battery system 
power-down requirements to prevent damage to the battery system.
•

When there are multiple batteries in the system, powering down any one battery 
will power down all batteries.
•

The circuit breakers between the inverter and the battery, and between battery 
systems, must be installed in accordance with local laws and regulations.
•

•

To ensure effective protection of the battery system, keep the cover plate of the 
battery system switch in a closed state. The protective cover should automatically 
close after being opened. If the battery system switch will not be used for an 
extended period, secure it with screws.

Power-Off Procedure

DANGER

NOTICE

193

Sayfa 195

❺: Optional based on local laws and regulations.

8.2 Removing the Equipment

Ensure the device is powered off.
•

Wear personal protective equipment when operating the device.
•

Use proper disassembly tools when removing wiring terminals to avoid 
damaging the terminals or the device.
•

Unless otherwise specified, the device disassembly sequence is the reverse of the 
installation sequence, which will not be reiterated in this document.
•

DANGER

194

Sayfa 196

Power down the system.
1. 

Use labels to mark the cable types for the cables connected in the system.
2. 

Disconnect the connection cables of the Inverter, Battery, and smart meter in the 
system, such as: DC cable, AC cable, Communication cable, PE cable.
3. 

Remove devices such as the smart communication stick, Inverter, Battery, smart 
meter, etc.
4. 

Store the equipment properly. If it needs to be put into use later, ensure that the 
storage conditions meet the requirements.
5. 

8.3 Disposing of the Equipment

When the equipment can no longer be used and needs to be disposed of, please 
dispose of it according to the electrical waste disposal requirements of the 
regulations in the country/region where the equipment is located. The equipment 
must not be disposed of as general household waste.

8.4 Routine Maintenance

•

If any issues that may affect the battery or energy storage inverter system are 
found, contact after-sales personnel. Disassembly by unauthorized personnel is 
prohibited.

•

If exposed internal copper wires are found in the conductive cables, do not touch 
them. High voltage danger. Contact after-sales personnel. Disassembly by 
unauthorized personnel is prohibited.

•

In case of other emergencies, contact after-sales personnel immediately. 
Operate only under the guidance of after-sales personnel, or wait for on-site 
operation by after-sales personnel.

WARNING

195

Sayfa 197

Maintenan
ce Item
Maintenance Method
Maintenanc
e Cycle

Check for foreign objects or 
dust on the heat sink, fan, and 
air inlet/outlet.
Check if the installation space 
meets requirements, and if 
there is any debris 
accumulation around the 
equipment.

System 
Cleaning

Check if the equipment 
installation is secure and if 
fastening screws are loose.
Check for any damage or 
deformation on the equipment 
exterior.

System 
Installation

Check for loose electrical 
connections, damaged cable 
sheaths, or exposed copper 
wires.

Electrical 
Connection
s

Check if the sealing of the 
equipment's cable entry holes 
meets requirements. Re-seal if 
gaps are too large or 
unblocked.

Sealing

If the battery has been unused 
or not fully charged for an 
extended period, regular 
charging is recommended.

Battery 
Maintenanc
e

8.5 fault

The fault content in the manual is updated irregularly, and there may be slight 
variations across different models. Please refer to the real-time display on your 
device for specific details.

Maintenance 
Purpose

Once every 
6 months
Prevent cooling 
failures.

Once every 
6 months to 
once a year

Confirm equipment 
installation stability.

Once every 
6 months to 
once a year

Confirm reliability of 
electrical 
connections.

Confirm machine 
sealing and intact 
waterproof 
performance.

Once a year

Once every 
15 days
Protect battery 
service life.

NOTICE

196

Sayfa 198

8.5.1 Viewing Fault/Alarms Information

All detailed information on faults and alarms in the energy storage system is 
displayed in the [SEMS+ App] and [SEMS+ WEB]. If your product experiences an 
abnormality and you do not see related fault information in [SEMS+ App] or [SEMS+ 
WEB], please contact the after-sales service center.

SEMS+ App
•

Open the SEMS+ App and log in using any account.
1. 

Go to [power station] > [Alarms] to view all power station fault information.
2. 

Click on a specific fault name to view details such as the time of occurrence, 
possible causes, and solutions.
3. 

SEMS+ WEB
•

Open SEMS+ WEB and log in using any account.
1. 

On the power station details interface, click [Alarms] to view all alarm information 
for the current power station.
2. 

8.5.2 Fault Information and Troubleshooting

Please perform troubleshooting according to the following methods. If the 
troubleshooting methods cannot help you, please contact the after-sales service 

center.
When contacting the after-sales service center, please collect the following 
information to facilitate a quick resolution.

Product information, such as: serial number, software version, device installation 
time, fault occurrence time, fault occurrence frequency, etc.
1. 

2. 

Device installation environment, such as: weather conditions, whether components 
are obstructed or shaded, etc. It is recommended to provide photos, videos, and 
other files of the installation environment to assist in problem analysis.

Grid conditions.
3. 

8.5.2.1 System Malfunction

If the system experiences an unlisted issue, or if following the instructions does not 
prevent the problem or abnormality, immediately stop operating the system and 

197

Sayfa 199

contact your dealer at once.

No.
fault
Solution

Unable to 
search for the 
Smart Comm 
Stick wireless 
signal

1

Unable to 
connect to the 
Smart Comm 
Stick wireless 
signal

2

3
Unable to find 
the router SSID

After all 
configuration is 
complete, the 
Smart Comm 
Stick fails to 
connect to the 
router

4

Ensure no other devices are connected to the Smart 
Comm Stick's wireless signal.
1. 

Ensure the App is upgraded to the latest version.
2. 

Ensure the Smart Comm Stick is powered normally, 
with the blue signal light blinking or steadily on.
3. 

Ensure the smart device is within the communication 
range of the Smart Comm Stick.
4. 

Refresh the device list in the App.
5. 

Restart the inverter.
6. 

Ensure no other devices are connected to the Smart 
Comm Stick's wireless signal.
1. 

2. 

Restart the inverter or the Comm Stick, then try 
connecting to the Smart Comm Stick wireless signal 
again.

Ensure Bluetooth encryption pairing is successful.
3. 

Place the router closer to the Smart Comm Stick, or add 
a WiFi repeater to enhance the WiFi signal.
1. 

Reduce the number of devices connected to the router.
2. 

Restart the inverter.
1. 

2. 

Check if the network name, encryption method, and 
password in the WiFi configuration match those of the 
router.

Restart the router.
3. 

Place the router closer to the Smart Comm Stick, or add 
a WiFi repeater to enhance the WiFi signal.
4. 

198

Sayfa 200

No.
fault
Solution

After all 
configuration is 
complete, the 
Smart Comm 
Stick fails to 
connect to the 
server

5

Restart the router and the inverter.

8.5.2.2 Inverter Fault

8.5.2.2.1 Troubleshooting (Fault Codes F01-F40)

Faul
t 
Cod
e

Fault Name
Possible Cause
Troubleshooting Suggestions

1. Grid power 
outage.
2. AC line or AC 
switch is 
disconnected.

1. The alarm will disappear 
automatically after grid power supply 
is restored.
2. Check if the AC line or AC switch is 
disconnected.

F01
Grid Power 
Outage

199

Sayfa 201

Faul
t 
Cod
e

Fault Name
Possible Cause
Troubleshooting Suggestions

Grid voltage is 
higher than the 
allowable range, or 
the duration of high 
voltage exceeds the 
HVRT set value.

Grid 
Overvoltage 
Protection

F02

1. If it occurs occasionally, it may be a 
short-term grid anomaly. The 
inverter will resume normal 
operation after detecting a normal 
grid, requiring no manual 
intervention.
2. If it occurs frequently, check if the 
grid voltage is within the allowable 
range. If not, contact the local power 
operator. If yes, also modify the grid 
overvoltage protection point after 
obtaining consent from the local 
power operator.
3. If normal operation cannot be 
restored for a long time, check if the 
AC side circuit breaker and output 
cables are properly connected.

200

Sayfa 202

Faul
t 
Cod
e

Fault Name
Possible Cause
Troubleshooting Suggestions

Grid voltage is lower 
than the allowable 
range, or the 
duration of low 
voltage exceeds the 
LVRT set value.

Grid 
Undervoltag
e Protection

F03

1. If it occurs occasionally, it may be a 
short-term grid anomaly. The 
inverter will resume normal 
operation after detecting a normal 
grid, requiring no manual 
intervention.
2. If it occurs frequently, check if the 
grid voltage is within the allowable 
range. If not, contact the local power 
operator. If yes, also modify the grid 
undervoltage protection point after 
obtaining consent from the local 
power operator.
3. If normal operation cannot be 
restored for a long time, check if the 
AC side circuit breaker and output 
cables are properly connected.

201

Sayfa 203

Faul
t 
Cod
e

Fault Name
Possible Cause
Troubleshooting Suggestions

Abnormal grid 
voltage detection or 
extremely high 
voltage triggers the 
fault.

Grid Rapid 
Overvoltage 
Protection

F04

The moving average 
of grid voltage 
within 10min 
exceeds the range 
specified by safety 
regulations.

10min 
Overvoltage 
Protection

F05

1. If it occurs occasionally, it may be a 
short-term grid anomaly. The 
inverter will resume normal 
operation after detecting a normal 
grid, requiring no manual 
intervention.
2. If it occurs frequently, check if the 
grid voltage is within the allowable 
range. If not, contact the local power 
operator. If yes, also modify the grid 
undervoltage protection point after 
obtaining consent from the local 
power operator.
3. If normal operation cannot be 
restored for a long time, check if the 
AC side circuit breaker and output 
cables are properly connected.

Check if the grid voltage has been 
operating at a high level for a long 
time. If it occurs frequently, check if 
the grid frequency is within the 
allowable range. If not, contact the 
local power operator. If yes, also 
modify the grid 10min overvoltage 
protection point after obtaining 
consent from the local power 
operator.

202

Sayfa 204

Faul
t 
Cod
e

Fault Name
Possible Cause
Troubleshooting Suggestions

Grid anomaly: The 
actual grid 
frequency is higher 
than the local grid 
standard 
requirements.

Grid 
Overfrequen
cy

F06

Grid anomaly: The 
actual grid 
frequency is lower 
than the local grid 
standard 
requirements.

Grid 
Underfreque
ncy

F07

1. If it occurs occasionally, it may be a 
short-term grid anomaly. The 
inverter will resume normal 
operation after detecting a normal 
grid, requiring no manual 
intervention.
2. If it occurs frequently, check if the 
grid frequency is within the allowable 
range. If not, contact the local power 
operator. If yes, also modify the grid 
overfrequency protection point after 
obtaining consent from the local 
power operator.

1. If it occurs occasionally, it may be a 
short-term grid anomaly. The 
inverter will resume normal 
operation after detecting a normal 
grid, requiring no manual 
intervention.
2. If it occurs frequently, check if the 
grid frequency is within the allowable 
range. If not, contact the local power 
operator. If yes, also modify the grid 
overfrequency protection point after 
obtaining consent from the local 
power operator.

203

Sayfa 205

Faul
t 
Cod
e

Fault Name
Possible Cause
Troubleshooting Suggestions

Grid anomaly: The 
rate of change of the 
actual grid 
frequency does not 
comply with the 
local grid standard.

Grid 
Frequency 
Instability

F08

The grid has been 
disconnected, but 
grid voltage is 
maintained due to 
the presence of 
loads. Grid 
connection is 
stopped according 
to safety protection 
requirements.

Anti-
islanding 
Protection

F09

Grid anomaly: The 
duration of 
abnormal grid 
voltage exceeds the 
time specified for 
high/low voltage 
ride-through.

LVRT 
Undervoltag
e

F10

1. If it occurs occasionally, it may be a 
short-term grid anomaly. The 
inverter will resume normal 
operation after detecting a normal 
grid, requiring no manual 
intervention.
2. If it occurs frequently, check if the 
grid frequency is within the allowable 
range. If not, contact the local power 
operator.

1. If it occurs occasionally, it may be a 
short-term grid anomaly. The 
inverter will resume normal 
operation after detecting a normal 
grid, requiring no manual 
intervention.
2. If it occurs frequently, check if the 
grid frequency is within the allowable 
range. If not, contact the local power 
operator.

1. If it occurs occasionally, it may be a 
short-term grid anomaly. The 
inverter will resume normal 
operation after detecting a normal 
grid, requiring no manual 
intervention.
2. If it occurs frequently, check if the 
grid voltage and frequency are within 
the allowable range and stable. If 
not, contact the local power 
operator.

204

Sayfa 206

Faul
t 
Cod
e

Fault Name
Possible Cause
Troubleshooting Suggestions

Grid anomaly: The 
duration of 
abnormal grid 
voltage exceeds the 
time specified for 
high/low voltage 
ride-through.

F11
HVRT 
Overvoltage

The insulation 
resistance to ground 
of the input 
decreases during 
inverter operation.

F12
30mA GFCI 
Protection

The insulation 
resistance to ground 
of the input 
decreases during 
inverter operation.

F13
60mA GFCI 
Protection

1. If it occurs occasionally, it may be a 
short-term grid anomaly. The 
inverter will resume normal 
operation after detecting a normal 
grid, requiring no manual 
intervention.
2. If it occurs frequently, check if the 
grid voltage and frequency are within 
the allowable range and stable. If 
not, contact the local power 
operator.

1. If it occurs occasionally, it may be 
caused by occasional external line 
anomalies. It will resume normal 
operation after the fault is cleared, 
requiring no manual intervention.
2. If it occurs frequently or cannot be 
restored for a long time, check if the 
PV string's impedance to ground is 
too low.

1. If it occurs occasionally, it may be 
caused by occasional external line 
anomalies. It will resume normal 
operation after the fault is cleared, 
requiring no manual intervention.
2. If it occurs frequently or cannot be 
restored for a long time, check if the 
PV string's impedance to ground is 
too low.

205

Sayfa 207

Faul
t 
Cod
e

Fault Name
Possible Cause
Troubleshooting Suggestions

The insulation 
resistance to ground 
of the input 
decreases during 
inverter operation.

F14
150mA GFCI 
Protection

The insulation 
resistance to ground 
of the input 
decreases during 
inverter operation.

GFCI 
Gradual 
Change 
Protection

F15

The DC component 
of the inverter 
output current is 
higher than the 
safety regulation or 
the machine's 
default allowable 
range.

F16
DCI Level 1 
Protection

1. If it occurs occasionally, it may be 
caused by occasional external line 
anomalies. It will resume normal 
operation after the fault is cleared, 
requiring no manual intervention.
2. If it occurs frequently or cannot be 
restored for a long time, check if the 
PV string's impedance to ground is 
too low.

1. If it occurs occasionally, it may be 
caused by occasional external line 
anomalies. It will resume normal 
operation after the fault is cleared, 
requiring no manual intervention.
2. If it occurs frequently or cannot be 
restored for a long time, check if the 
PV string's impedance to ground is 
too low.

1. If it is caused by an external fault, 
the inverter will automatically 
resume normal operation after the 
fault disappears, requiring no 
manual intervention.
2. If this alarm occurs frequently, 
affecting the normal power 
generation of the power station, 
contact the dealer or after-sales 
service center.

206

Sayfa 208

Faul
t 
Cod
e

Fault Name
Possible Cause
Troubleshooting Suggestions

The DC component 
of the inverter 
output current is 
higher than the 
safety regulation or 
the machine's 
default allowable 
range.

F17
DCI Level 2 
Protection

1. If it is caused by an external fault, 
the inverter will automatically 
resume normal operation after the 
fault disappears, requiring no 
manual intervention.
2. If this alarm occurs frequently, 
affecting the normal power 
generation of the power station, 
contact the dealer or after-sales 
service center.

207

Sayfa 209

Faul
t 
Cod
e

Fault Name
Possible Cause
Troubleshooting Suggestions

1. PV string shorted 
to protective earth.
2. The PV string is 
installed in a humid 
environment for a 
long time and the 
line has poor 
insulation to 
ground.
3. Low insulation 
impedance of the 
battery port line to 
ground.

Low 
Insulation 
Resistance

F18

1. Check the impedance of the PV 
string/battery port to protective 
earth. A value greater than 80kΩ is 
normal. If the checked value is less 
than 80kΩ, locate and rectify the 
short circuit point.
2. Check if the inverter's protective 
earth wire is correctly connected.
3. If it is confirmed that the 
impedance is indeed below the 
default value in rainy/overcast 
environments, please reset the 
inverter's "Insulation Impedance 
Protection Point" via the App.
For inverters in the Australia and 
New Zealand markets, the insulation 
impedance fault can also be alerted 
in the following ways:
1. The inverter is equipped with a 
buzzer. When a fault occurs, the 
buzzer sounds continuously for 1 
minute; if the fault is not resolved, 
the buzzer sounds again every 30 
minutes.
2. If the inverter is added to the 
monitoring platform and alarm 
notification methods are set, alarm 
information can be sent to customers 
via email.

208

Sayfa 210

Faul
t 
Cod
e

Fault Name
Possible Cause
Troubleshooting Suggestions

1. The inverter's 
protective earth wire 
is not connected.
2. When the PV 
string output is 
grounded, the 
inverter output side 
is not connected to 
an isolation 
transformer.

F19
Grounding 
Abnormal

Hard Anti-
reverse 
Power Flow 
Protection

Load abnormal 
fluctuation

F20

1. Please confirm if the inverter's 
protective earth wire is not properly 
connected.
2. In scenarios where the PV string 
output is grounded, please confirm if 
the inverter output side is connected 
to an isolation transformer.

1. If it is caused by an external fault, 
the inverter will automatically 
resume normal operation after the 
fault disappears, requiring no 
manual intervention.
2. If this alarm occurs frequently, 
affecting the normal power 
generation of the power station, 
contact the dealer or after-sales 
service center.

209

Sayfa 211

Faul
t 
Cod
e

Fault Name
Possible Cause
Troubleshooting Suggestions

F21
Internal 
Comm Loss

Slave DSP1 
communication 
timeout - Master 
DSP, Slave DSP2 
communication 
timeout - Master 
DSP, Slave DSP2 
communication 
timeout - Slave 
DSP1, Master DSP 
communication 
timeout - Slave 
DSP1, Master DSP 
communication 
timeout - Slave DSP2 
or Slave DSP1 
communication 
timeout - Slave 
DSP2:
1. Chip not powered 
on
2. Chip firmware 
version error

Disconnect the AC output side switch 
and DC input side switch, wait 
5 minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, contact the 
dealer or after-sales service center.

210

Sayfa 212

Faul
t 
Cod
e

Fault Name
Possible Cause
Troubleshooting Suggestions

Master DSP CAN 
module error, Slave 
DSP1 CAN module 
error or Slave DSP2 
CAN module error:
1. Frame format 
error
2. Parity error
3. CAN bus offline
4. Hardware CRC 
error
5. Control bit is 
receive (transmit) 
when transmitting 
(receiving)
6. Transmission to a 
disallowed unit

Generator 
Waveform 
Detection 
Fault

1. This fault will 
always be displayed 
when a generator is 
not connected;
2. When the 
generator is 
operating, failure to 
meet generator 
safety regulations 
will trigger this fault.

F22

Generator 
Abnormal 
Connection

F23

F24
Generator 
Voltage Low

F25
Generator 
Voltage High

Generator 
Frequency 
Low

F26

1. Ignore this fault when a generator 
is not connected;
2. When this fault occurs due to a 
generator fault, it is normal. Wait for 
a period after the generator 
recovers, and the fault will clear 
automatically;
3. This fault will not affect the normal 
operation of the off-grid mode.
4. When both the generator and grid 
are connected and meet safety 
requirements, the grid has priority 
for grid connection, and the system 
will operate in grid-connected state.

211

Sayfa 213

Faul
t 
Cod
e

Fault Name
Possible Cause
Troubleshooting Suggestions

Generator 
Frequency 
High

F27

Parallel 
communication 
cable not securely 
connected or 
parallel IO chip 
damaged

Parallel I/O 
Self-check 
Abnormal

F28

Paralell Grid 
Line 
Reversed

Some machines 
have grid lines 
reversed with others

F29

AC HCT 
check 
Abnormal

AC sensor has 
sampling 
abnormality

F30

GFCI HCT 
Check 
Abnormal

Leakage current 
sensor has sampling 
abnormality

F31

Inverter 
Internal 
Failure

F32

Inverter has a fault

Possible causes:
Flash content 
changed; Flash 
lifespan exhausted;

Flash 
Read/Write 
Error

F33

Check if the parallel communication 
cable is securely connected, then 
check if the IO chip is damaged. If 
yes, replace the IO chip.

Reconnect the grid lines.

Disconnect the AC output side switch 
and DC input side switch, wait 
5 minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, contact the 
dealer or after-sales service center.

Disconnect the AC output side switch 
and DC input side switch, wait 
5 minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, contact the 
dealer or after-sales service center.

Disconnect the AC output side switch 
and DC input side switch, wait 
5 minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, contact the 
dealer or after-sales service center.

1. Upgrade to the latest firmware.
2. Contact the dealer or after-sales 
service center.

212

Sayfa 214

Faul
t 
Cod
e

Fault Name
Possible Cause
Troubleshooting Suggestions

The arc fault module 
did not detect an arc 
fault during the arc 
self-check process.

F34
AFCI Check 
Failure

Cabinet temperature 
is too high, possible 
causes:
1. Poor ventilation at 
the inverter 
installation location.
2. Ambient 
temperature is too 
high.
3. Internal fan 
operation is 
abnormal.

Cabinet 
Overtemper
ature

F35

Disconnect the AC output side switch 
and DC input side switch, wait 
5 minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, contact the 
dealer or after-sales service center.

1. Check if the ventilation at the 
inverter installation location is good 
and if the ambient temperature 
exceeds the maximum allowable 
ambient temperature range.
2. If ventilation is poor or ambient 
temperature is too high, improve its 
ventilation and heat dissipation 
conditions.
3. If both ventilation and ambient 
temperature are normal, contact the 
dealer or after-sales service center.

213

Sayfa 215

Faul
t 
Cod
e

Fault Name
Possible Cause
Troubleshooting Suggestions

BUS overvoltage, 
possible causes:
1. PV voltage is too 
high;
2. Inverter BUS 
voltage sampling 
abnormality;
3. Poor isolation 
effect of the dual-
split transformer at 
the inverter output 
side, causing mutual 
interference when 
two inverters are 
connected in 
parallel, with one 
inverter reporting 
DC overvoltage 
during grid 
connection;

F36
Bus 
Overvoltage

Disconnect the AC output side switch 
and DC input side switch, wait 
5 minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, contact the 
dealer or after-sales service center.

214

Sayfa 216

Faul
t 
Cod
e

Fault Name
Possible Cause
Troubleshooting Suggestions

PV input voltage is 
too high, possible 
cause:
PV array 
configuration error, 
too many PV panels 
connected in series 
in a string, causing 
the string's open-
circuit voltage to be 
higher than the 
inverter's maximum 
operating voltage.

F37
PV Input 
Overvoltage

1. Unreasonable 
component 
configuration.
2. Hardware 
damage.

PV 
Continuous 
Hardware 
Overcurrent

F38

1. Unreasonable 
component 
configuration.
2. Hardware 
damage.

PV 
Continuous 
Software 
Overcurrent

F39

Check the series configuration of the 
corresponding PV array string to 
ensure the string's open-circuit 
voltage is not higher than the 
inverter's maximum operating 
voltage. After the PV array is correctly 
configured, the inverter alarm will 
disappear automatically.

Disconnect the AC output side switch 
and DC input side switch, wait 5 
minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, contact the 
dealer or after-sales service center.

Disconnect the AC output side switch 
and DC input side switch, wait 5 
minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, contact the 
dealer or after-sales service center.

215

Sayfa 217

Faul
t 
Cod
e

Fault Name
Possible Cause
Troubleshooting Suggestions

String 
Reverse 
Connection 
(String 1-n)
n: 
Determined 
based on 
the actual 
number of 
inverter 
strings.

F40, 
F98

PV string reverse 
connection

8.5.2.2.2 Troubleshooting (Fault Codes F41-F80)

Fault 
Code

 Fault 
Name
Fault Cause
Troubleshooting Suggestions

1. Off-grid side 
output exceeds 
specifications.
2. Off-grid side short 
circuit.
3. Off-grid terminal 
voltage is too low.
4. When used as a 
heavy load port, the 
heavy load exceeds 
specifications.

Generator 
Port 
Overload

F41

Check if the string is reverse 
connected.

Confirm the off-grid side output 
voltage, current, power and other 
data to identify the cause of the 
problem.

216

Sayfa 218

Fault 
Code

 Fault 
Name
Fault Cause
Troubleshooting Suggestions

DC Arcing 
Failure(Strin
g1-n)
n: 
Determined 
based on 
the actual 
number of 
inverter 
strings.

1. DC side 
connection 
terminals are loose.
2. DC side 
connection 
terminals have poor 
contact.
3. DC cable core is 
damaged or has 
poor contact.

F42

Utility grid 
abnormality: 
Anomaly in grid 
voltage detection 
triggers the fault.

Grid 
Waveform 
Abnormal

F43

Utility grid 
abnormality: Single-
phase voltage drop 
in the grid.

F44
Grid Phase 
Loss

1. After the machine reconnects to 
the grid, check if the voltage and 
current of each circuit show 
abnormal reduction or drop to zero.
2. Check if the DC side terminals are 
firmly connected.

1. If it occurs occasionally, it may be 
due to a short-term grid anomaly. 
The inverter will resume normal 
operation after detecting a normal 
grid, requiring no manual 
intervention.
2. If it occurs frequently, please 
check if the grid voltage and 
frequency are within the allowable 
range and stable. If not, contact the 
local power operator.

1. If it occurs occasionally, it may be 
due to a short-term grid anomaly. 
The inverter will resume normal 
operation after detecting a normal 
grid, requiring no manual 
intervention.
2. If it occurs frequently, please 
check if the grid voltage and 
frequency are within the allowable 
range and stable. If not, contact the 
local power operator.

217

Sayfa 219

Fault 
Code

 Fault 
Name
Fault Cause
Troubleshooting Suggestions

Grid 
Voltage 
Imbalance

Excessive difference 
in grid phase 
voltages.

F45

Inverter and grid 
wiring abnormality: 
Wiring is not in 
positive sequence.

Grid Phase 
Sequence 
Failure

F46

Rapidly shuts down 
output after 
detecting a grid 
power outage 
condition.

Grid Rapid 
Shutdown 
Protection

F47

Grid 
Neutral 
Wire Loss 
(Split Grid)

Neutral wire loss in 
a split-phase grid.

F48

Low impedance or 
short circuit 
between output 
phase line and PE.

F49
L-PE Short 
Circuit

1. If it occurs occasionally, it may be 
due to a short-term grid anomaly. 
The inverter will resume normal 
operation after detecting a normal 
grid, requiring no manual 
intervention.
2. If it occurs frequently, please 
check if the grid voltage and 
frequency are within the allowable 
range and stable. If not, contact the 
local power operator.

1. Check if the inverter and grid 
wiring are in positive sequence. The 
fault will disappear automatically 
after correct wiring (e.g., swapping 
any two live wires).
2. If the wiring is correct but the fault 
persists, contact the dealer or after-
sales service center.

The fault disappears automatically 
after grid power supply is restored.

1. The alarm disappears 
automatically after grid power supply 
is restored.
2. Check if the AC line or AC switch is 
disconnected.

Measure the impedance between the 
output phase line and PE, locate the
position with low impedance and 
repair it.

218

Sayfa 220

Fault 
Code

 Fault 
Name
Fault Cause
Troubleshooting Suggestions

F50
DCV Level 1 
Protection

Abnormal load 
fluctuation.

F51
DCV Level 2 
Protection

Abnormal load 
fluctuation.

North American 
safety regulations 
require manual 
recovery or waiting 
24h after multiple 
faults; automatic 
recovery is not 
allowed.

Leakage 
current 
(GFCI) 
Multiple 
Fault 
Shutdown

F52

North American 
safety regulations 
require manual 
recovery or waiting 
24h after multiple 
faults; automatic 
recovery is not 
allowed.

DC Arcing 
(AFCI) 
Multiple 
Fault 
Shutdown

F53

1. If it is caused by an external fault, 
the inverter will automatically 
resume normal operation after the 
fault disappears, requiring no 
manual intervention.
2. If this alarm occurs frequently and 
affects normal power generation of 
the plant, contact the dealer or after-
sales service center.

Please check if the PV string's 
impedance to ground is too low.

1. After the machine reconnects to 
the grid, check if the voltage and 
current of each circuit show 
abnormal reduction or drop to zero.
2. Check if the DC side terminals are 
firmly connected.

219

Sayfa 221

Fault 
Code

 Fault 
Name
Fault Cause
Troubleshooting Suggestions

Communication loss 
with external 
devices of the 
inverter, possibly 
due to peripheral 
power issues, 
communication 
protocol mismatch, 
or lack of 
configuration for the 
corresponding 
peripheral.

External 
Communica
tion Link 
Break

F54

Back-up 
Port 
Overload 
Fault

Prevents the 
inverter from 
continuously 
outputting overload.

F55

Back-up 
Port 
Overvoltage 
Fault

Prevents damage to 
loads caused by 
inverter output 
overvoltage.

F56

Waiting time for the 
Box to switch relays 
is too long during 
grid-to-off-grid 
transition.

F57
External 
Box Fault

CT connection wire 
disconnected 
(Japanese safety 
regulation 
requirement).

F58
CT Loss 
Fault

Judgment is based on the actual 
model and detection enable bits. 
Peripherals not supported by some 
models will not be detected.

Turn off some off-grid loads to 
reduce the inverter's off-grid output 
power.

1. If it occurs occasionally, it may be 
caused by load switching and 
requires no manual intervention.
2. If it occurs frequently, contact the 
dealer or after-sales service center.

1. Check if the Box is working 
normally.
2. Check if the Box communication 
wiring is correct.

Check if the CT wiring is correct.

220

Sayfa 222

Fault 
Code

 Fault 
Name
Fault Cause
Troubleshooting Suggestions

Parallel 
communication 
cable is not securely 
connected or some 
machines are 
offline.

Parallel CAN 
Communica
tion 
Abnormal

F59

Parallel 
Back-up 
Connection 
Reversed

Backup lines of 
some machines are 
reversed with 
others.

F60

Inverter 
Soft Start 
Failure

Inverter soft start 
failure during off-
grid cold start.

F61

F62
AC HCT 
Failure

HCT sensor 
abnormality.

F63
GFCI HCT 
Failure

Leakage current 
sensor abnormality.

Inverter 
Internal 
Failure

F64

Inverter has a fault.

Check if all machines are powered on 
and if the parallel communication 
cable is securely connected.

Reconnect the backup lines.

Check if the inverter module is 
damaged.

Turn off the AC output side switch 
and DC input side switch, wait 5  
minutes, then turn them on. If the 
fault persists, contact the dealer or 
after-sales service center.

Turn off the AC output side switch 
and DC input side switch, wait 5  
minutes, then turn them on. If the 
fault persists, contact the dealer or 
after-sales service center.

Turn off the AC output side switch 
and DC input side switch, wait 5  
minutes, then turn them on. If the 
fault persists, contact the dealer or 
after-sales service center.

221

Sayfa 223

Fault 
Code

 Fault 
Name
Fault Cause
Troubleshooting Suggestions

AC terminal 
temperature is too 
high, possible 
causes:
1. Inverter 
installation location 
lacks ventilation.
2. Ambient 
temperature is too 
high.
3. Internal fan 
operation is 
abnormal.

AC Terminal 
Overtemper
ature

F65

Inverter module 
temperature is too 
high, possible 
causes:
1. Inverter 
installation location 
lacks ventilation.
2. Ambient 
temperature is too 
high.
3. Internal fan 
operation is 
abnormal.

INV Module 
Overtemper
ature

F66

1. Check if the ventilation at the 
inverter installation location is 
adequate and if the ambient 
temperature exceeds the maximum 
allowable range.
2. If ventilation is poor or ambient 
temperature is too high, improve the 
ventilation and heat dissipation 
conditions.
3. If both ventilation and ambient 
temperature are normal, contact the 
dealer or after-sales service center.

1. Check if the ventilation at the 
inverter installation location is 
adequate and if the ambient 
temperature exceeds the maximum 
allowable range.
2. If ventilation is poor or ambient 
temperature is too high, improve the 
ventilation and heat dissipation 
conditions.
3. If both ventilation and ambient 
temperature are normal, contact the 
dealer or after-sales service center.

222

Sayfa 224

Fault 
Code

 Fault 
Name
Fault Cause
Troubleshooting Suggestions

Boost module 
temperature is too 
high, possible 
causes:
1. Inverter 
installation location 
lacks ventilation.
2. Ambient 
temperature is too 
high.
3. Internal fan 
operation is 
abnormal.

Boost 
Module 
Overtemper
ature

F67

Output filter 
capacitor 
temperature is too 
high, possible 
causes:
1. Inverter 
installation location 
lacks ventilation.
2. Ambient 
temperature is too 
high.
3. Internal fan 
operation is 
abnormal.

AC 
Capacitor 
Overtemper
ature

F68

Possible causes:
1. IGBT short circuit.
2. Inverter sampling 
circuit abnormality.

PV 
IGBT Short 
Circuit Fault

F69

1. Check if the ventilation at the 
inverter installation location is 
adequate and if the ambient 
temperature exceeds the maximum 
allowable range.
2. If ventilation is poor or ambient 
temperature is too high, improve the 
ventilation and heat dissipation 
conditions.
3. If both ventilation and ambient 
temperature are normal, contact the 
dealer or after-sales service center.

1. Check if the ventilation at the 
inverter installation location is 
adequate and if the ambient 
temperature exceeds the maximum 
allowable range.
2. If ventilation is poor or ambient 
temperature is too high, improve the 
ventilation and heat dissipation 
conditions.
3. If both ventilation and ambient 
temperature are normal, contact the 
dealer or after-sales service center.

Turn off the AC output side switch 
and DC input side switch, wait 5  
minutes, then turn them on. If the 
fault persists, contact the dealer or 
after-sales service center.

223

Sayfa 225

Fault 
Code

 Fault 
Name
Fault Cause
Troubleshooting Suggestions

1. Software issue 
causing no PWM 
generation.
2. Drive circuit 
abnormality.
3. IGBT open circuit.

PV IGBT 
Open 
Circuit Fault

F70

F71
NTC 
Abnormal

NTC temperature 
sensor abnormality.

F72
PWM 
Abnormal

Abnormal PWM 
waveform.

CPU 
Interrupt 
Abnormal

CPU interrupt 
abnormality.

F73

Functional safety 
detection detected 
an abnormality.

F74
Microelectr
onics Fault

F75
PV HCT 
Fault

Boost current 
sensor abnormality.

1.5V 
Reference 
Abnormal

Reference circuit 
fault.

F76

Turn off the AC output side switch 
and DC input side switch, wait 5  
minutes, then turn them on. If the 
fault persists, contact the dealer or 
after-sales service center.

Turn off the AC output side switch 
and DC input side switch, wait 5  
minutes, then turn them on. If the 
fault persists, contact the dealer or 
after-sales service center.

Turn off the AC output side switch 
and DC input side switch, wait 5  
minutes, then turn them on. If the 
fault persists, contact the dealer or 
after-sales service center.

Turn off the AC output side switch 
and DC input side switch, wait 5  
minutes, then turn them on. If the 
fault persists, contact the dealer or 
after-sales service center.

Turn off the AC output side switch 
and DC input side switch, wait 5  
minutes, then turn them on. If the 
fault persists, contact the dealer or 
after-sales service center.

Turn off the AC output side switch 
and DC input side switch, wait 5  
minutes, then turn them on. If the 
fault persists, contact the dealer or 
after-sales service center.

224

Sayfa 226

Fault 
Code

 Fault 
Name
Fault Cause
Troubleshooting Suggestions

0.3V 
Reference 
Abnormal

Reference circuit 
fault.

F77

CPLD 
Version 
Identificatio
n Error

CPLD version 
identification error.

F78

Communication 
content error or 
timeout between 
CPLD and DSP.

CPLD 
Communica
tion Fault

F79

Model 
Identificatio
n Fault

Fault related to 
model identification 
error.

F80

8.5.2.2.3 Troubleshooting (Fault Codes F81-F121)

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

F81
P-Bus 
Overvoltage

Turn off the AC output side switch 
and DC input side switch, wait 5  
minutes, then turn them on. If the 
fault persists, contact the dealer or 
after-sales service center.

Turn off the AC output side switch 
and DC input side switch, wait 5  
minutes, then turn them on. If the 
fault persists, contact the dealer or 
after-sales service center.

Turn off the AC output side switch 
and DC input side switch, wait 5  
minutes, then turn them on. If the 
fault persists, contact the dealer or 
after-sales service center.

Disconnect the AC output side switch 
and DC input side switch, wait for 5 
minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, please contact 
the dealer or after-sales service 
center.

225

Sayfa 227

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

BUS overvoltage, 
possible causes:
1. PV voltage too 
high;
2. Inverter BUS 
voltage sampling 
abnormal;
3. Poor isolation 
effect of the split-
phase transformer 
behind the inverter, 
causing mutual 
interference when 
two inverters are 
grid-connected, with 
one inverter 
reporting DC 
overvoltage during 
grid connection;

F82
N-Bus 
Overvoltage

Bus 
Overvoltage 
(Sub CPU1)

F83

P-Bus 
Overvoltage 
(Sub CPU1)

F84

Disconnect the AC output side switch 
and DC input side switch, wait for 5 
minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, please contact 
the dealer or after-sales service 
center.

226

Sayfa 228

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

BUS overvoltage, 
possible causes:
1. PV voltage too 
high;
2. Inverter BUS 
voltage sampling 
abnormal;
3. Poor isolation 
effect of the split-
phase transformer 
behind the inverter, 
causing mutual 
interference when 
two inverters are 
grid-connected, with 
one inverter 
reporting DC 
overvoltage during 
grid connection;

N-Bus 
Overvoltage 
(Sub CPU1)

F85

Bus 
Overvoltage 
(Sub CPU2)

F86

P-Bus 
Overvoltage 
(Sub CPU2)

F87

Disconnect the AC output side switch 
and DC input side switch, wait for 5 
minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, please contact 
the dealer or after-sales service 
center.

227

Sayfa 229

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

BUS overvoltage, 
possible causes:
1. PV voltage too 
high;
2. Inverter BUS 
voltage sampling 
abnormal;
3. Poor isolation 
effect of the split-
phase transformer 
behind the inverter, 
causing mutual 
interference when 
two inverters are 
grid-connected, with 
one inverter 
reporting DC 
overvoltage during 
grid connection;

N-Bus 
Overvoltage 
(Sub CPU2)

F88

P-Bus 
Overvoltage 
(CPLD)

F89

Disconnect the AC output side switch 
and DC input side switch, wait for 5 
minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, please contact 
the dealer or after-sales service 
center.

228

Sayfa 230

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

BUS overvoltage, 
possible causes:
1. PV voltage too 
high;
2. Inverter BUS 
voltage sampling 
abnormal;
3. Poor isolation 
effect of the split-
phase transformer 
behind the inverter, 
causing mutual 
interference when 
two inverters are 
grid-connected, with 
one inverter 
reporting DC 
overvoltage during 
grid connection;

N-Bus 
Overvoltage 
(CPLD)

F90

FlyCap 
Software 
Overvoltage

FlyCap overvoltage, 
possible causes:
1. PV voltage too 
high;
2. Inverter FlyCap 
voltage sampling 
abnormal;

F91

FlyCap 
Hardware 
Overvoltage

F92

Disconnect the AC output side switch 
and DC input side switch, wait for 5 
minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, please contact 
the dealer or after-sales service 
center.

229

Sayfa 231

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

FlyCap 
undervoltage, 
possible causes:
1. PV energy 
insufficient;
2. Inverter FlyCap 
voltage sampling 
abnormal;

FlyCap 
Undervoltag
e

F93

FlyCap precharge 
failure, possible 
causes:
1. PV energy 
insufficient;
2. Inverter FlyCap 
voltage sampling 
abnormal;

FlyCap 
Precharge 
Failure

F94

1. Control loop 
parameters 
unreasonable
2. Hardware damage

FlyCap 
Precharge 
Abnormal

F95

String 
Overcurrent(
String 1-n)
n: 
Determined 
by the actual 
number of 
inverter 
strings

Possible causes:
1. String 
overcurrent;
2. String current 
sensor abnormal

F96, 
F97 

Disconnect the AC output side switch 
and DC input side switch, wait for 5 
minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, please contact 
the dealer or after-sales service 
center.

Disconnect the AC output side switch 
and DC input side switch, wait for 5 
minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, please contact 
the dealer or after-sales service 
center.

Disconnect the AC output side switch 
and DC input side switch, wait for 5 
minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, please contact 
the dealer or after-sales service 
center.

Disconnect the AC output side switch 
and DC input side switch, wait for 5 
minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, please contact 
the dealer or after-sales service 
center.

230

Sayfa 232

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

String 
Missing(Stri
ng 1-n)
n: 
Determined 
by the actual 
number of 
inverter 
strings

F99, 
F100

String fuse open (if 
present)
Check if the fuse is open.

Battery 1 precharge 
circuit fault 
(precharge resistor 
burnt, etc.)

Battery 1 
Precharge 
Fault

F101

Battery 1 relay 
cannot operate 
normally

F102
Battery 1 
Relay Failure

Battery 1 connection 
voltage exceeds the 
machine's rated 
range

Battery 1 
Connection 
Overvoltage

F103

Battery 2 precharge 
circuit fault 
(precharge resistor 
burnt, etc.)

Battery 2 
Precharge 
Fault

F104

Check if the precharge circuit is in 
good condition, and whether the 
battery voltage matches the bus 
voltage after only the battery is 
powered on. If not consistent, please 
contact the dealer or after-sales 
service center.

After powering on the battery, check 
if the battery relay is working, and if a 
closing sound is heard. If not 
operating, please contact the dealer 
or after-sales service center.

Confirm if the battery voltage is 
within the machine's rated range.

Check if the precharge circuit is in 
good condition, and whether the 
battery voltage matches the bus 
voltage after only the battery is 
powered on. If not consistent, please 
contact the dealer or after-sales 
service center.

231

Sayfa 233

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

Battery 2 relay 
cannot operate 
normally

F105
Battery 2 
Relay Failure

Battery 2 connection 
voltage exceeds the 
machine's rated 
range

Battery 2 
Connection 
Overvoltage

F106

Abnormal during 
carrier 
synchronization grid 
connection

On-grid 
PWM Sync 
Failure

F107

DSP 
Communicat
ion Fault

F108

-
-

Abnormal cable 
connection between 
inverter and STS

F109
External STS 
Fault

After powering on the battery, check 
if the battery relay is working, and if a 
closing sound is heard. If not 
operating, please contact the dealer 
or after-sales service center.

Confirm if the battery voltage is 
within the machine's rated range.

1. Check if the sync cable connection 

is normal
2. Check if the master/slave settings 
are normal;
3. Disconnect the AC output side 
switch and DC input side switch, wait 
for 5 minutes, then close the AC 
output side switch and DC input side 
switch. If the fault persists, please 
contact the dealer or after-sales 
service center.

Check if the wiring sequence of the 
harness between the inverter and the 
STS corresponds one by one in order.

232

Sayfa 234

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

1. Inverter reports 
error and 
disconnects from 
grid
2. Meter 
communication 
unstable
3. Reverse power 
flow condition 
occurs

F110
Export Limit 
Protection

F111
Bypass 
Overload
-
-

F112
Black Start 
Failure
-
-

F113
Offgrid AC 
Ins Volt High
-
-

Relay abnormal, 
reasons:
1. Relay abnormal 
(relay short circuit)
2. Relay sampling 
circuit abnormal.
3. AC side wiring 
abnormal (possible 
loose connection or 
short circuit)

F114
Relay Failure 
2

SVG 
Precharge 
Disabled

SVG precharge 
hardware failure

F115

Nighttime 
SVG PID 
Prevention 
Fault

PID prevention 
hardware abnormal

F116

1. Check if the inverter has other 
error messages. If yes, handle them 
accordingly;
2. Check if the meter connection is 
reliable;
3. If this alarm occurs frequently, 
affecting normal power generation of 
the plant, please contact the dealer 
or after-sales service center.

Disconnect the AC output side switch 
and DC input side switch, wait for 5 
minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, please contact 
the dealer or after-sales service 
center.

Contact the dealer or after-sales 
service center.

233

Sayfa 235

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

DSP Version 
Identificatio
n Error

DSP software 
version identification 
error

F117

1. Software issue 
causing inverter 
drive to turn off 
earlier than flyback 
drive:
2. Inverter drive 
circuit abnormal 
causing failure to 
turn on:
3. PV voltage too 
high;
4. Mos voltage 
sampling abnormal;

MOS 
Continuous 
Overvoltage

F118

F119
Bus Short 
Circuit Fault
Hardware damage

Bus 
Sampling 
Abnormal

1. BUS voltage 
sampling hardware 
fault

F120

Disconnect the AC output side switch 
and DC input side switch, wait for 5 
minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, please contact 
the dealer or after-sales service 
center.

Disconnect the AC output side switch 
and DC input side switch, wait for 5 
minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, please contact 
the dealer or after-sales service 
center.

If the BUS short circuit fault occurs 
and the inverter remains offline, 
please contact the dealer or after-
sales service center.

Disconnect the AC output side switch 
and DC input side switch, wait for 5 
minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, please contact 
the dealer or after-sales service 
center.

234

Sayfa 236

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

1. BUS voltage 
sampling hardware 
fault
2. Battery voltage 
sampling hardware 
fault
3. Dcrly relay fault

DC Side 
Sampling 
Abnormal

F121

8.5.2.2.4 Troubleshooting (Fault Codes F122-F163)

Disconnect the AC output side switch 
and DC input side switch, wait for 5 
minutes, then close the AC output 
side switch and DC input side switch. 
If the fault persists, please contact 
the dealer or after-sales service 
center.

235

Sayfa 237

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

There are three PV 
Access Modes, 
taking a four-
channel MPPT as an 
example:
1. Parallel Mode: i.e., 
AAAA mode (same-
source mode), PV1-
PV4 are from the 
same source, all 4 PV 
channels are 
connected to the 
same solar panel.
2. Partial Parallel 
Mode: i.e., AACC 
mode, PV1 and PV2 
are connected from 
the same source, 
PV3 and PV4 are 
connected from the 
same source.
3. Independent 
Mode: i.e., ABCD 
mode (different-
source), PV1, PV2, 
PV3, PV4 are 
connected 
independently, each 
of the 4 PV channels 
connects to one 
solar panel.
This fault is reported 

PV Access 
Mode 
Setting Error

F122

Check if the PV Access Mode is set 
correctly (ABCD, AACC, AAAA), and 
reconfigure the PV Access Mode 
correctly.
1. Confirm that all actual PV channels 
are correctly connected.
2. If the PV connections are correct, 
use the APP or the screen to check if 
the currently set "PV Access Mode" 
corresponds to the actual connection 
mode.
3. If the currently set "PV Access 
Mode" does not match the actual 
connection mode, use the APP or the 
screen to set the "PV Access Mode" to 
the mode consistent with the actual 
situation. After setting, disconnect 
and restart the PV and AC power 
supply.
4. After configuration, if the current 
"PV Access Mode" matches the actual 
connection mode but the fault 
persists, contact the dealer or the 
after-sales service center.

236

Sayfa 238

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

if the actual PV 
connection mode 
does not match the 
PV Access Mode 
configured on the 
device.

Multi-
channel PV 
Phase Error

PV Input Mode 
Setting Error

F123

Check if the PV Access Mode is set 
correctly (ABCD, AACC, AAAA), and 
reconfigure the PV Access Mode 
correctly.
1. Confirm that all actual PV channels 
are correctly connected.
2. If the PV connections are correct, 
use the APP or the screen to check if 
the currently set "PV Access Mode" 
corresponds to the actual connection 
mode.
3. If the currently set "PV Access 
Mode" does not match the actual 
connection mode, use the APP or the 
screen to set the "PV Access Mode" to 
the mode consistent with the actual 
situation. After setting, disconnect 
and restart the PV and AC power 
supply.
4. After configuration, if the current 
"PV Access Mode" matches the actual 
connection mode but the fault 
persists, contact the dealer or the 
after-sales service center.

237

Sayfa 239

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

Battery 1 
Reverse 
Connection 
fault

Battery 1 positive 
and negative 
terminals are 
reversed

F124

Battery 2 
Reverse 
Connection 
fault

Battery 2 positive 
and negative 
terminals are 
reversed

F125

Abnormal 
Battery 
Connection

Abnormal Battery 
Connection

F126

High battery 
temperature, 
possible causes:
1. Inverter is 
installed in a poorly 
ventilated location.
2. Ambient 
temperature is too 
high.

BAT 
Overtemper
ature

F127

3. Internal fan is 
malfunctioning.

F128
Ref Voltage 
Abnormal

Reference circuit 
fault

Check if the polarities of the battery 
and the machine's terminals are 
consistent.

Check if the polarities of the battery 
and the machine's terminals are 
consistent.

Check if the battery is working 
normally.

Disconnect the AC output side switch 
and the DC input side switch. After 5  
minutes, close the AC output side 
switch and the DC input side switch. 
If the fault persists, contact the 
dealer or the after-sales service 
center.

Disconnect the AC output side switch 
and the DC input side switch. After 5  
minutes, close the AC output side 
switch and the DC input side switch. 
If the fault persists, contact the 
dealer or the after-sales service 
center.

238

Sayfa 240

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

Cabinet temperature 
is too low, possible 
cause: ambient 
temperature is too 
low.

Cabinet 
Under 
Temperatur
e

F129

AC side surge 
protection device 
failure

F130
AC Side SPD 
fault

DC side surge 
protection device 
failure

F131
DC Side SPD 
fault

Internal fan 
abnormal, possible 
causes:
1. Fan power supply 
abnormal;
2. Mechanical fault 
(locked rotor);
3. Fan aging or 
damage.

F132
Internal Fan 
Abnormal

External fan 
abnormal, possible 
causes:
1. Fan power supply 
abnormal;
2. Mechanical fault 
(locked rotor);
3. Fan aging or 
damage.

F133
External Fan 
Abnormal

Disconnect the AC output side switch 
and the DC input side switch. After 5  
minutes, close the AC output side 
switch and the DC input side switch. 
If the fault persists, contact the 
dealer or the after-sales service 
center.

Replace the AC side surge protection 
device.

Replace the DC side surge protection 
device.

Disconnect the AC output side switch 
and the DC input side switch. After 5  
minutes, close the AC output side 
switch and the DC input side switch. 
If the fault persists, contact the 
dealer or the after-sales service 
center.

239

Sayfa 241

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

PID hardware fault 
or PV voltage too 
high causing PID 
suspension

PID 
Diagnosis 
Abnormal

F134

Possible causes:
Overcurrent or PV 
reverse connection 
caused the trip-
switch to open;

Trip-Switch 
Trip 
Warning

F135

Possible causes:
Overcurrent caused 
the trip-switch to 
open;

Historical PV 
IGBT  Short 
Circuit 
Warning

F136

No action required for PID 
suspension warning caused by high 
PV voltage. For PID hardware fault, 
clear the PID fault by turning the PID 
switch off and then on. Replace the 
PID device.

Contact the dealer or the after-sales 
service center; The reason for 
tripping is a PV short circuit or 
reverse connection. Check if there is 
a historical PV short circuit warning 
or a historical PV reverse connection 
warning. If present, a technician 
needs to inspect the corresponding 
PV condition. After checking and 
confirming no fault, manually close 
the trip-switch and clear this warning 
via the "Clear Historical Faults" 
operation in the APP interface.

Contact the dealer or the after-sales 
service center; The technician needs 
to check the Boost hardware and the 
external string for faults according to 
the historical PV short circuit warning 
sub-code. After checking and 
confirming no fault, clear this 
warning via the "Clear Historical 
Faults" operation in the APP 
interface.

240

Sayfa 242

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

Historical PV 
Reverse 
Connection 
Warning 
(String 1-n)
(n: 
determined 
by the actual 
number of 
inverter 
strings)

Possible causes:
PV reverse 
connection caused 
the trip-switch to 
open;

F137
, 
F138

Possible causes:
1. Flash content 
changed;
2. Flash end of life;

Flash 
Read/Write 
Error 
Warning

F139

This warning may 
only be reported 
after anti-backfeed 
function is enabled. 
Possible causes:
1. Meter not 
connected;
2. Communication 
cable connection 
between the meter 
and the inverter is 
incorrect.

F140
Meter 
Comm Loss

PV Panel 
Type 
Identificatio
n Failure

PV panel 
identification 
hardware abnormal

F141

Contact the dealer or the after-sales 
service center; The technician needs 
to check the corresponding string for 
reverse connection and check for 
voltage differences in the PV panel 
configuration according to the 
historical PV reverse connection 
warning sub-code. After checking 
and confirming no fault, clear this 
warning via the "Clear Historical 
Faults" operation in the APP 
interface.

1. Upgrade to the latest firmware;
2. Contact the dealer or the after-
sales service center.

Check the meter wiring, connect the 
meter correctly. If the fault persists 
after checking, contact the dealer or 
the after-sales service center.

Contact the dealer or the after-sales 
service center.

241

Sayfa 243

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

PV string mismatch, 
two strings under 
the same MPPT 
channel have 
different open-
circuit voltage 
configurations

F142
PV String 
Mismatch

F143
CT Not 
Connected
CT not connected
Check CT wiring.

F144
CT Reverse 
Connection

CT reverse 
connection
Check CT wiring.

F145
PE Loss
Ground wire not 
connected
Check the ground wire.

High String 
Terminal 
Temperatur
e (String 
1~8)

Bit 1 of the PV 
terminal 
temperature alarm 
sub-code in register 
37176 is set

F146

High String 
Terminal 
Temperatur
e (String 
9~16)

Bit 2 of the PV 
terminal 
temperature alarm 
sub-code in register 
37177 is set

F147

High String 
Terminal 
Temperatur
e (String 
17~20)

Bit 3 of the PV 
terminal 
temperature alarm 
sub-code in register 
37178 is set

F148

Check the open-circuit voltages of 
the two strings, configure strings 
with the same open-circuit voltage 
under the same MPPT channel. 
Prolonged string mismatch poses a 
safety risk.

-

-

-

242

Sayfa 244

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

Historical PV 
Reverse 
Connection 
Warning 
(String 
33~48)

Possible causes:
PV reverse 
connection caused 
the trip-switch to 
open;

F149

F150
Battery 1 
Low Voltage

Battery voltage is 
below the set value
-

F151
Battery 2 
Low Voltage

Battery voltage is 
below the set value
-

Battery is not in 
charging mode, 
voltage is below the 
shutdown voltage

Low Voltage 
of Battery 
Power

F152

F153
Battery 1 
High Voltage
-
-

F154
Battery 2 
High Voltage
-
-

Contact the dealer or the after-sales 
service center; The technician needs 
to check the corresponding string for 
reverse connection and check for 
voltage differences in the PV panel 
configuration according to the 
historical PV reverse connection 
warning sub-code. After checking 
and confirming no fault, clear this 
warning via the "Clear Historical 
Faults" operation in the APP 
interface.

-

243

Sayfa 245

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

1. PV string shorted 
to protective earth.
2. PV string installed 
in a long-term 
humid environment 
with poor line-to-
ground insulation.

Online Low 
Insulation 
Resistance

F155

Micro-grid 
Overload 
Warning

backup port input 
current is too high

F156

F157
Manual 
Reset
-
-

Generator 
Phase 
Sequence 
Abnormal

F158

-
-

The multiplexed 
(generator) port is 
configured for 
micro-grid or large 
load, but a 
generator is actually 
connected

Multiplexed 
Port 
Configuratio
n Abnormal

F159

EMS issued a forced 
off-grid command, 
but the off-grid 
function is not 
enabled

F160
EMS Forced 
Off-grid

1. Check the impedance of the PV 
string to protective earth. If a short 
circuit is found, rectify the short 
circuit point.
2. Check if the inverter's protective 
earth wire is correctly connected.
3. If it is confirmed that the 
impedance is indeed below the 
default value in rainy/cloudy 
conditions, reconfigure the 
"Insulation Resistance Protection 
Point".

No action required if it occurs 
occasionally; If this warning appears 
frequently, contact the dealer or the 
after-sales service center.

Use the APP to change the 
multiplexed (generator) port 
configuration.

Enable the off-grid function.

244

Sayfa 246

Faul
t 
Cod
e

Fault Name
Possible Cause
Recommended Action

Passive Anti-
islanding 
Protection

F161

-
-

Actual grid type 
(two-phase or split-
phase) does not 
match the set safety 
standard

F162
Grid Type 
Fault

Grid abnormal: The 
rate of change of 
grid voltage phase 
does not comply 
with local grid 
standards.

F163
Grid Phase 
Instability

8.5.2.2.5 Fault Phenomenon Handling

Switch to the corresponding safety 
standard according to the actual grid 
type.

1. If it occurs occasionally, it may be a 
temporary grid abnormality. The 
inverter will resume normal 
operation after detecting a normal 
grid, no manual intervention is 
required.
2. If it occurs frequently, check if the 
grid frequency is within the allowable 
range. If not, contact the local power 
operator.

245

Sayfa 247

Fault Name 
Fault Cause
Fault Handling Suggestions

1. This fault will be 
displayed 
continuously when 
no generator is 
connected. 
2. When the 
generator is 
operating, if it does 
not meet the 
generator safety 
regulations, this 
fault will be 
triggered.

Generator 
Failure

BMS Status Bit 
Error
BMS module failure

1. Poor ventilation 
of the machine 
2. Hot air flows back 
to the ambient 
temperature 
sampling point

Ambient 
Overtemperat
ure

1. If the generator is not connected, ignore 
this fault. 
2. If this fault appears when the generator 
has a fault, it is normal. Wait for a period 
after the generator recovers, and the fault 
will clear automatically. 
3. This fault will not affect the normal 
operation of the off-grid mode. 
4. When both the generator and the grid are 
connected and meet safety requirements, 
the grid has priority for grid connection, and 
the system will operate in grid-tied mode.

Disconnect the AC output side switch and 
the DC input side switch. After 5 minutes, 
close the AC output side switch and the DC 
input side switch. If the fault persists, please 
contact the dealer or after-sales service 
center.

Disconnect the AC output side switch and 
the DC input side switch. After 5 minutes, 
close the AC output side switch and the DC 
input side switch. If the fault persists, please 
contact the dealer or after-sales service 
center.

246

Sayfa 248

Fault Name 
Fault Cause
Fault Handling Suggestions

PV terminal 
overtemperature, 
possible causes: 
1. Poor ventilation 
at the inverter 
installation location. 
2. Ambient 
temperature is too 
high. 
3. Internal fan 
operation is 
abnormal.

PV Terminal 
Overtemperat
ure

BAT terminal 
overtemperature, 
possible causes: 
1. Poor ventilation 
at the inverter 
installation location. 
2. Ambient 
temperature is too 
high. 
 

BAT Terminal 
Overtemperat
ure

AC terminal 
overtemperature, 
possible causes: 
1. Poor ventilation 
at the inverter 
installation location. 
2. Ambient 
temperature is too 
high. 
3. Internal fan 
operation is 
abnormal.

AC Terminal 
Overtemperat
ure Warning

1. Check if the ventilation at the inverter 
installation location is adequate and if the 
ambient temperature exceeds the 
maximum allowable range. 
2. If ventilation is poor or the ambient 
temperature is too high, please improve its 
ventilation and heat dissipation conditions. 
3. If both ventilation and ambient 
temperature are normal, please contact the 
dealer or after-sales service center.

1. Check if the ventilation at the inverter 
installation location is adequate and if the 
ambient temperature exceeds the 
maximum allowable range. 
2. If ventilation is poor or the ambient 
temperature is too high, please improve its 
ventilation and heat dissipation conditions. 
3. If both ventilation and ambient 
temperature are normal, please contact the 
dealer or after-sales service center.

247

Sayfa 249

Fault Name 
Fault Cause
Fault Handling Suggestions

BAT terminal 
overtemperature, 
possible causes: 
1. Poor ventilation 
at the inverter 
installation location. 
2. Ambient 
temperature is too 
high.

BAT Terminal 
Overtemperat
ure Warning

Three-phase 
external wiring 
error

Three-phase 
on-grid fault

Abnormal cable 
connection between 
the inverter and the 
STS

External STS 
Failure

Fault Name 
Possible Cause
Recommended Action

In a parallel system, 
if a slave unit has 
not communicated 
with the master for 
more than 400 
seconds.

Parallel 
Comm 
Timeout 
Shutdown

Three-phase 
off-grid phase 
loss fault

Phase loss in a 
three-phase system.

1. Check if the ventilation at the inverter 
installation location is adequate and if the 
ambient temperature exceeds the 
maximum allowable range. 
2. If ventilation is poor or the ambient 
temperature is too high, please improve its 
ventilation and heat dissipation conditions. 
3. If both ventilation and ambient 
temperature are normal, please contact the 
dealer or after-sales service center.

Re-wire the connections.

Check if the wiring sequence of the harness 
between the inverter and the STS 
corresponds one-to-one in order.

Check if the parallel communication cable 
harness is securely connected. Check if the 
slave unit addresses are duplicated.

Check if all inverters are powered on.
1. 

Check if each phase of the three-phase 
system is connected to an inverter.
2. 

248

Sayfa 250

Fault Name 
Possible Cause
Recommended Action

Externally triggered 
hardware EPO 
button or remotely 
triggered EPO 
command.

EPO

Automatically 
triggered when the 
combustible gas 
device detects a 
concentration of 
20% LEL or higher.

High 
Combustible 
Gas 
Concentration

Mismatch 
Between 
Combustible 
Gas Device Air 
Damper Open 
Command 
and Feedback 
Signal

Mismatch between 
the control signal to 
open the air damper 
and the feedback 
signal.

Check via the App if 
the one-key 
shutdown function 
is enabled.

One-Key 
Shutdown

If it was actively triggered by a remote 
shutdown command, it can be ignored.
1. 

2. 

If not actively triggered, please contact 
the distributor or after-sales service 
center.

1. 

After the fault occurs, the unit will 
automatically open the air damper to 
exhaust and reduce the concentration. 
The fault will clear automatically after the 
concentration remains below 5% LEL for 
15 minutes.

2. 

If the fault triggers a cluster-level fire 
protection fault, the air damper will 
automatically close. Confirm the damper 
status within 30s to ensure the cluster-
level fire protection operates in an 
enclosed space.

3. 

Please contact the distributor or after-
sales service center. 
 

Check the cable harness signal connection 
for issues.
1. 

Please contact the distributor or after-
sales service center.
2. 

Disable the one-key shutdown function.

249

Sayfa 251

Fault Name 
Possible Cause
Recommended Action

Offline 
Shutdown
-
-

Remote 
Shutdown
-
-

On-Grid SPD 
Fault
-

Off-Grid SPD 
Fault
-

Child Node 
Communicati
on Failure

Internal Comm 
Abnormal

Communication link 
abnormality 
between the 
dehumidifier and 
the LC control box.

Dehumidifier 
Communicati
on Fault

Try restarting the unit and observe if the 
fault clears.
1. 

2. If the fault persists after restart, please 
contact the distributor or after-sales service 
center.

Try restarting the unit and observe if the 
fault clears.
1. 

2. If the fault persists after restart, please 
contact the distributor or after-sales service 
center.

Try restarting the unit and observe if the 
fault clears.
1. 

2. If the fault persists after restart, please 
contact the distributor or after-sales service 
center.

Check the communication cable harness 
for the link and observe if the fault clears.
1. 

Try restarting the unit and observe if the 
fault clears.
2. 

3. 

If the fault persists after restart, please 
contact the distributor or after-sales 
service center.

250

Sayfa 252

Fault Name 
Possible Cause
Recommended Action

1. 

The combustible 
gas device left the 
factory without 
the 485 address 
properly 
configured to 2.

Combustible 
Gas Detection 
Device 
Communicati
on Fault

2. 

Communication 
link abnormality 
between the 
combustible gas 
device and the LC 
control box.

Communication link 
abnormality 
between the control 
board and the diesel 
generator (DG).

DG 
Communicati
on Failure

1. Individual cell 
voltage too high. 
2. Voltage sensing 
line abnormality.
Battery Over 
Voltage
1. Total battery 
voltage too high. 
2. Voltage sensing 
line abnormality.

Battery 
Undervoltage

1. Individual cell 
voltage too low. 
2. Voltage sensing 
line abnormality.

Check the communication cable harness 
for the link and observe if the fault clears.
1. 

Try restarting the unit and observe if the 
fault clears.
2. 

3. 

Use the method provided by the 
combustible gas device manufacturer to 
check if the device address is 2. If not, 
modify it.

4. 

If the fault persists after restart, please 
contact the distributor or after-sales 
service center.

1. Check the communication cable harness 
for the link and observe if the fault clears. 
2. Try restarting the unit and observe if the 
fault clears. 
3. If the fault persists after restart, please 
contact the distributor or after-sales service 
center.

Record the fault phenomenon, restart the 
battery, wait a few minutes, and confirm if 
the fault disappears. If the problem persists 
after restart, please contact the after-sales 
service center.

251

Sayfa 253

Fault Name 
Possible Cause
Recommended Action

1. Total battery 
voltage too low. 
2. Voltage sensing 
line abnormality.

1. Charging current 
too high, battery 
current limiting 
abnormality: 
sudden changes in 
temperature and 
voltage values. 
2. Inverter response 
abnormal.

Battery 
Overcurrent

Battery discharge 
current too high.

1. Ambient 
Overtemperature. 
2. Temperature 
sensor abnormality.

Battery 
Overtemperat
ure

1. Ambient 
temperature too 
low. 
2. Temperature 
sensor abnormality.

Battery 
Undertemper
ature

Battery 
Terminal 
Overtemperat
ure

Terminal 
temperature too 
high.

252

Sayfa 254

Fault Name 
Possible Cause
Recommended Action

Battery 
Imbalance

1. Large 
temperature 
difference. At 
different stages, the 
battery will limit its 
power, i.e., limit 
charge/discharge 
current. Therefore, 
this issue is 
generally difficult to 
occur. 
2. Cell capacity 
degradation leads 
to excessive internal 
resistance, causing 
large temperature 
rise during 
overcurrent and 
thus a large 
temperature 
difference. 
3. Poor welding of 
cell tabs leads to 
rapid cell 
temperature rise 
during overcurrent. 
4. Temperature 
sampling issue. 
5. Loose power 
cable connections.

253

Sayfa 255

Fault Name 
Possible Cause
Recommended Action

1. Inconsistent cell 
aging levels. 
2. Slave board chip 
issues can also 
cause excessive cell 
voltage difference. 
3. Slave board 
balancing issues can 
also cause excessive 
cell voltage 
difference. 
4. Caused by wiring 
harness issues.

Insulation 
resistance 
damaged.

Insulation 
Resistance

Pre-charging 
Failure
Pre-charging Failure

Sensing Line 
Fault

Battery sensing line 
poor contact or 
disconnected.

Cell voltage sensing 
line poor contact or 
disconnected.

Cell temperature 
sensing line poor 
contact or 
disconnected.

Check if the ground wire is properly 
connected, restart the battery. If the 
problem persists after restart, please 
contact the after-sales service center.

Indicates that during pre-charging, the 
voltage across the pre-charge MOS always 
exceeds the specified threshold. Power off 
and restart, then observe if the fault 
persists. Check if the wiring is correct and if 
the pre-charge MOS is damaged.

Check the wiring, restart the battery. If the 
problem persists after restart, please 
contact the after-sales service center.

Check the wiring, restart the battery. If the 
problem persists after restart, please 
contact the after-sales service center.

254

Sayfa 256

Fault Name 
Possible Cause
Recommended Action

Dual-channel 
current comparison 
error too large, or 
current sensing line 
circuit abnormal.

Dual-channel 
voltage comparison 
error too large, or 
MCU vs. AFE voltage 
comparison error 
too large, or voltage 
sensing line circuit 
abnormal.

Temperature 
sensing line circuit 
abnormal, poor 
contact, or 
disconnected.

Overvoltage level 5 
or overtemperature 
level 5, tripping the 
three-terminal fuse.

Relay or MOS 
Overtemperat
ure

Relay or MOS 
overtemperature.

Shunt 
Overtemperat
ure

Shunt 
overtemperature.

The three-terminal fuse is blown. Please 
contact the after-sales service center to 
replace the main control board.

This fault indicates the MOS tube 
temperature exceeds the specified 
threshold. Power off and let it sit for 2 hours 
for temperature recovery.

This fault indicates the shunt temperature 
exceeds the specified threshold. Power off 
and let it sit for 2 hours for temperature 
recovery.

255

Sayfa 257

Fault Name 
Possible Cause
Recommended Action

BMS1 Other 
Faults 1 
(Residential 
Storage)

Relay or MOS open 
circuit.

Relay or MOS short 
circuit.

Communication 
abnormality 
between main 
cluster and slave 
cluster, or cell 
inconsistency 
between clusters.

Battery system loop 
wiring harness 
abnormal, causing 
the interlock signal 
not to form a loop.

BMS and PCS 
communication 
abnormal.

BMS master and 
slave control 
communication 
cable harness 
abnormal.

1. Upgrade software, power off and let it sit 
for 5 minutes, restart and see if the fault 
persists.
2. If it persists, replace the battery pack.

1. Upgrade software, power off and let it sit 
for 5 minutes, restart and see if the fault 
persists.
2. If it persists, replace the battery pack.

1. Check the slave unit's battery information 
and software version, and if the 
communication cable connection to the 
master unit is normal.
2. Upgrade software.

Check if the termination resistor is installed 
correctly.

1. Confirm if the communication cable 
interface definitions between the inverter 
and the connected battery are correct.
2. Please contact the after-sales service 
center to check backend data and observe if 
the inverter and battery software match 
correctly.

1. Check wiring, restart the battery.
2. Upgrade the battery firmware. If the 
problem persists after restart, please 
contact the after-sales service center.

256

Sayfa 258

Fault Name 
Possible Cause
Recommended Action

Communication loss 
between main 
negative chips.

Circuit breaker, 
shunt trip 
abnormality.

MCU self-test 
failure.

1. Software version 
too low or BMS 
board damaged. 
2. Large number of 
parallel inverters, 
causing excessive 
inrush current 
during battery pre-
charging.

MCU internal fault.

Total control current 
exceeds the 
specified threshold.

1. Power off and let it sit for 5 minutes, 
restart and see if the fault persists.
2. Check if the communication pins on the 
PACK and PCU bottom blind-mate 
connectors are loose or misaligned.

Upgrade software, restart the battery. If the 
problem persists after restart, please 
contact the after-sales service center.

1. Upgrade software, observe if the fault 
persists. 
2. For parallel systems, perform a black start 
of the battery first, then start the inverters.

Upgrade software, restart the battery. This 
usually indicates MCU or external 
component damage. If the problem persists 
after restart, please contact the after-sales 
service center.

Power off and let it sit for 5 minutes, 
restart and see if the fault persists.
1. 

Check if the inverter power setting is too 
high, exceeding the bus load capacity.  
2. 

257

Sayfa 259

Fault Name 
Possible Cause
Recommended Action

Inconsistent cells in 
parallel battery 
clusters.

Reverse polarity 
connection of 
parallel battery 
clusters.

Severe 
overtemperature/ov
ervoltage etc., 
triggering the fire 
protection system.

Air conditioner 
abnormal failure.

Cabinet door not 
closed.
Check if the cabinet door is properly closed.

Supply voltage too 
high.

Insufficient supply 
voltage.

Air 
Conditioner 
Failure

No voltage input.

Unstable supply 
voltage.

Compressor voltage 
unstable.

Sensor poor contact 
or damaged.

Air conditioner fan 
abnormal.

Confirm if the cells in the parallel battery 
clusters are consistent.

Check if the positive and negative terminals 
of the parallel battery clusters are reversed.

Contact the after-sales service center.

Try restarting the system. If the fault is not 
resolved, please contact the after-sales 
service center.

Confirm if the supply voltage meets the air 
conditioner input voltage requirements. Re-
power on after confirmation.

Try restarting the system. If the fault is not 
resolved, please contact the after-sales 
service center.

258

Sayfa 260

Fault Name 
Possible Cause
Recommended Action

BMS1 Other 
Faults 2 
(Residential 
Storage)

Internal voltage or 
current abnormality 
in DCDC.

DCDC overload or 
heatsink 
overtemperature, 
etc.

Cell sensing 
abnormality or 
inconsistent aging 
levels.

Fan operation not 
executed normally.
Please contact the after-sales service center.

Output terminal 
screws loose or 
poor contact.

Battery used for too 
long or cells 
severely damaged.

1. Software version 
too low or BMS 
board damaged. 
2. Large number of 
parallel inverters, 
causing excessive 
inrush current 
during battery pre-
charging.

Heating film 
damaged.
Please contact the after-sales service center.

Refer to specific DC fault content.

Please contact the after-sales service center.

1. Power off the battery, check wiring and 
output terminal screw condition. 
2. After confirmation, restart the battery, 
observe if the fault persists. If it persists, 
please contact the after-sales service center.

Please contact the after-sales service center 
to replace the pack.

1. Upgrade software, observe if the fault 
persists. 
2. For parallel systems, perform a black start 
of the battery first, then start the inverters.

259

Sayfa 261

Fault Name 
Possible Cause
Recommended Action

Heating film three-
terminal fuse blown, 
heating function 
unavailable.

Software model, Cell 
Type, hardware 
model mismatch.

Thermal 
management board 
communication 
cable disconnected.

Pack fan fault signal 
triggered.

DCDC Fault

Output port voltage 
too high.

DCDC module 
detects battery 
voltage exceeding 
maximum charging 
voltage.

Heatsink 
temperature too 
high.

Battery discharge 
current too high.

Please contact the after-sales service center.

Check if the software model, SN, Cell Type, 
and hardware model are consistent. If not, 
please contact the after-sales service center.

1. Power off and let it sit for 5 minutes, 
restart and see if the fault persists.
2. If the fault does not recover, contact 
after-sales to replace the pack.

Check the output port voltage. If the output 
port voltage is normal and the fault does 
not clear itself after restarting the battery, 
please contact the after-sales service center.

Stop charging, discharge to below 90% SOC 
or let it sit for 2 hours. If ineffective and the 
fault persists after restart, please contact 
the after-sales service center.

Let the battery sit for 1 hour for heatsink 
temperature to drop. If ineffective and the 
fault persists after restart, please contact 
the after-sales service center.

Check if the load exceeds the battery's 
discharge capability. Turn off the load or 
stop PCS operation for 60s. If ineffective and 
the fault persists after restart, please 
contact the after-sales service center.

260

Sayfa 262

Fault Name 
Possible Cause
Recommended Action

Output port power 
cable 
positive/negative 
reversed with 
parallel cluster 
battery or PCS.

Output power relay 
cannot close.

Power device 
temperature too 
high.

Relay welded/stuck.
If the fault persists after restart, please 
contact the after-sales service center.

Battery Rack 
Circulating 
Current 
Failure

1. Cell imbalance. 
2. First power-on 
without full charge 
calibration.

BMS1 Other 
Faults 3 
(Large-scale 
Storage)

Communication 
abnormal with Linux 
module.

Cell temperature 
rise too fast.

SOC below 10%.
Charge the battery.

Turn off the battery manual switch, check if 
the output port wiring is correct, restart the 
battery.

Check if the output port wiring is correct 
and if there is a short circuit. If ineffective 
and the fault persists after restart, please 
contact the after-sales service center.

Let the battery sit for 1 hour for internal 
power device temperature to drop. If 
ineffective and the fault persists after 
restart, please contact the after-sales service 
center.

Record the fault phenomenon, restart the 
battery, wait a few minutes, and confirm if 
the fault disappears. If the problem persists 
after restart, please contact the after-sales 
service center.

1. Check if the communication cable 
connection is normal. 
2. Upgrade software, restart the battery and 
observe if the fault persists. If it persists, 
please contact the after-sales service center.

Cell abnormal, contact after-sales to replace 
the pack.

261

Sayfa 263

Fault Name 
Possible Cause
Recommended Action

SN written does not 
comply with rules.

1. Communication 
abnormal within 
battery cluster daisy 
chain. 
2. Inconsistent cell 
aging levels 
between battery 
clusters.

High humidity 
inside pack.
-

Fuse blown.
Contact after-sales to replace the pack.

Battery low power.
Charge the battery.

Circuit breaker 
abnormal.
Contact after-sales to replace the pack.
BMS1 Other 
Faults 4 
(Large-scale 
Storage)
External device 
abnormal.
Contact after-sales to replace the pack.

Contactor 
Failure 1
-
-

Contactor 
Failure 2
-
-

Overload 
Protection 
(Ksic)

Sustained overload 
(exceeding 690KVA) 
for 10s.

Overload 
Protection 
(Smart Port)

Sustained overload 
(exceeding 690KVA) 
for 10s.

Check if the SN digit count is normal. If 
abnormal, please contact the after-sales 
service center.

1. Check the pack contact condition within a 
single cluster battery. 
2. Confirm the usage of each cluster battery, 
such as accumulated charge/discharge 
capacity, cycle count, etc. 
3. Please contact the after-sales service 
center.

Please contact the after-sales service center.

Please contact the after-sales service center.

262

Sayfa 264

Fault Name 
Possible Cause
Recommended Action

Overcurrent 
Protection 
(Ksic)

-
-

Overcurrent 
Protection 
(Smart Port)

-
-

1. Possibly the 
meter is not 
connected to the 
master. 
2. Possibly the 
meter 
communication 
cable is loose.

1. Check if the meter is connected to the 
master. 
2. Check if the meter communication cable 
is loose.

Master AC On 
Meter Comm 
Error

Parallel Slave 
Meter Error

Meter connected to 
a slave unit.

Set the unit with the meter connected as the 
master.

1. Slave address 
setting error. 
2. Slave 
communication 
cable loose.

1. Check if the slave addresses are 
duplicated. 
2. Check if the parallel communication cable 
is loose.

Slave AC On 
Timeout with 
Master

8.5.2.3 Battery Fault

Lynx C Series 60kWh Commercial & Industrial Battery System
•

No.
Fault Name
Possible Cause
Troubleshooting

Continuing to charge 
when the battery is 
fully charged

Stop charging. If not automatically 
restored, contact a professional 
technician to restart the system.

1
Battery Over 
Voltage

263

Sayfa 265

No.
Fault Name
Possible Cause
Troubleshooting

2
Battery 
Undervoltage

3
Battery 
Overcurrent

4
Battery 
Overtemperatu
re

5
Battery 

Undertemperature

6
Battery Terminal 

Overtemperature

7
Battery Imbalance

8
Insulation 

Resistance

9
Precharge Failure

10
Harness Fault

11
Relay Open Circuit
Relay Failure
Replace the relay.

Continuing to 
discharge when the 
battery is fully 
discharged

Stop discharging. If not 
automatically restored, contact a 
professional technician to restart 
the system.

Current exceeding 
the system's 
maximum current 
during 
charge/discharge

Reduce power. If not automatically 
restored, contact a professional 
technician to restart the system.

Perform cooling. If not 
automatically restored, contact a 
professional technician to restart 
the system.

Temperature too 
high during 
charge/discharge

Perform heating. If not automatically 

Temperature too low 

restored, contact a professional technician 

during charge/discharge

to restart the system.

Perform cooling. If not automatically 

Temperature too high 

restored, contact a professional technician 

during charge/discharge

to restart the system.

Excessive temperature or 

Stop charge/discharge to allow 

voltage difference 

temperature recovery. Perform balancing 

between individual cells

if voltage difference is excessive.

System insulation 

Check grounding condition.

resistance is low

Precharge circuit 

Check precharge circuit components.

component damage

Abnormal voltage, 

temperature, or current 

Check the corresponding harness.

sensing harness

264

Sayfa 266

No.
Fault Name
Possible Cause
Troubleshooting

12
Relay Short Circuit
Relay Failure
Replace the relay.

13
Cluster Parallel 

Fault

14
PCS Comm Loss

15
BMU 
Communication 
Fault

16
Circuit Breaker 
Sticking Fault

17
Fire Protection 
System 
Triggered

18
Air Conditioner 
Failure

BAT-S Series 15.3-56.3kWh High Voltage Battery
•

No.
Fault Name
Possible Causes
Troubleshooting

1
Charging 
Overvoltage2

Slave cluster loss of 

Check the reliability of the master-slave 

communication

harness connection.

Abnormal 
communication 
harness with PCS

Check the reliability of the harness 
connection.

Abnormal 
communication 
harness between 
BCU and BMU

Check the reliability of the harness 
connection.

Molded case circuit 
breaker failure

Replace the molded case circuit 
breaker.

Thermal runaway 
inside the system

Please contact the after-sales 
service center.

Abnormal fault 
occurred within the 
air conditioning 
system

Please contact the after-sales 
service center.

1. 

Power off and let it sit for 5 
minutes, then restart to see if the 
fault persists;

Cell voltage/total 
voltage too high
•

Voltage sampling 
line abnormal
•

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

265

Sayfa 267

No.
Fault Name
Possible Causes
Troubleshooting

2
Charging 
Overvoltage3

3
Discharge 
Undervoltage3

4
Discharge 
Undervoltage2

1. 

Power off and let it sit for 5 
minutes, then restart to see if the 
fault persists;

Cell voltage/total 
voltage too high
•

Voltage sampling 
line abnormal
•

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

1. 

Power off and let it sit for 5 
minutes, then restart to see if the 
fault persists;

2. 

Determine the inverter's working 
status, check if it is not charging 
the battery due to working mode 
or other issues. Try charging the 
battery via the inverter and 
observe if the fault is resolved.

Cell voltage/total 
voltage too low
•

Voltage sampling 
line abnormal
•

3. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

1. 

Power off and let it sit for 5 
minutes, then restart to see if the 
fault persists;

2. 

Determine the inverter's working 
status, check if it is not charging 
the battery due to working mode 
or other issues. Try charging the 
battery via the inverter and 
observe if the fault is resolved.

Cell voltage/total 
voltage too low
•

Voltage sampling 
line abnormal
•

3. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

266

Sayfa 268

No.
Fault Name
Possible Causes
Troubleshooting

5
Cell 
Overvoltage2

6
Cell 
Undervoltage2
Cell undervoltage

7
Significant Cell 
Voltage 
Variation2

1. 

Power off and let it sit for 5 
minutes, then restart to see if the 
fault persists;

Cell voltage/total 
voltage too high
•

Voltage sampling 
line abnormal
•

If the fault is not resolved, contact 
GoodWe after-sales service.

1. 

Power off and let it sit for 5 
minutes, then restart to see if the 
fault persists;

2. 

Determine the inverter's working 
status, check if it is not charging 
the battery due to working mode 
or other issues. Try charging the 
battery via the inverter and 
observe if the fault is resolved.

3. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

Restart the battery and wait for 
12 hours.
1. 

Significant cell 
voltage variation

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

267

Sayfa 269

No.
Fault Name
Possible Causes
Troubleshooting

8
Charging 
Overcurrent2

9
Discharge 
Overcurrent2

10
Battery Cell 
High 
Temperature2

•

Charging current 
too high, battery 
current limiting 
abnormal: sudden 
changes in 
temperature and 
voltage values

1. 

Power off and let it sit for 5 
minutes, then restart to see if the 
fault persists;

2. 

Check if the inverter power 
setting is too high, causing it to 
exceed the battery's rated 
operating current;

Inverter response 
abnormal
•

3. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

•

Discharge current 
too high, battery 
current limiting 
abnormal: sudden 
changes in 
temperature and 
SOC values

Inverter response 
abnormal
•

1. 

Power off and let it sit for 30 
minutes, then restart to see if the 
fault persists;

Cell temperature 
too high
•

Temperature 
sensor abnormal
•

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

268

Sayfa 270

No.
Fault Name
Possible Causes
Troubleshooting

11
Battery Cell 
Low 
Temperature2

12
Charging 
Overtemperatu
re2

13
Charging Low 
Temperature2

14
Discharge 
Overtemperatu
re2

1. 

Power off and let it sit for 30 
minutes, then restart to see if the 
fault persists;

•

Ambient 
temperature too 
low

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

Temperature 
sensor abnormal
•

1. 

Power off and let it sit for 30 
minutes; then restart to see if the 
fault persists;

Cell temperature 
too high
•

Temperature 
sensor abnormal
•

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

1. 

Power off and let it sit for 30 
minutes; then restart to see if the 
fault persists;

•

Ambient 
temperature too 
low

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

Temperature 
sensor abnormal
•

1. 

Power off and let it sit for 30 
minutes; then restart to see if the 
fault persists;

Cell temperature 
too high
•

Temperature 
sensor abnormal
•

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

269

Sayfa 271

No.
Fault Name
Possible Causes
Troubleshooting

15
Discharge Low 
Temperature2

16
Significant Cell 
Temperature 
Variation2

17
Precharge 
Disabled

18
Battery 
Tripping 
Battery Trip

1. 

Power off and let it sit for 30 
minutes; then restart to see if the 
fault persists;

•

Ambient 
temperature too 
low

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

Temperature 
sensor abnormal
•

1. 

Power off and let it sit for 30 
minutes; then restart to see if the 
fault persists;

Significant cell 
temperature 
variation

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

1. 

Power off and let it sit for 5 
minutes, then restart to see if the 
fault persists;

Precharge MOS 
closure failure

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

Let it sit for 10 minutes, then re-
close to recover;
1. 

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

270

Sayfa 272

No.
Fault Name
Possible Causes
Troubleshooting

19
Battery and 
Inverter Comm 
Failure

20
Specific 
Failures

21
Cluster Parallel 
Fault

22
Application 
Software Fault

23
Microelectronic
s Fault

24
Master Control 
Overload

25
SN Abnormal
Batteries with 
identical SN exist

26
Circuit Breaker 
Abnormal

BAT-C Series 61.4-112.6kWh Commercial & Industrial Battery System
•

1. 

Confirm the communication 
cable wiring sequence and DC 
cable are correct, and check for 
continuity.

Battery and Inverter 
Comm Failure

Restart the inverter and battery.
2. 

3. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

Battery specific 
failure

Please contact the after-sales 
service center.

Check the reliability of the master-
slave harness communication 
connection;
Please contact the after-sales 
service center.

Slave cluster loss of 
communication
Cluster parallel 
failure

Software self-test 
failure

Please contact the after-sales 
service center.

Electronic 
component failure

Please contact the after-sales 
service center.

Stop charging. If it does not 
recover automatically, please 
contact a professional technician to 
restart the system.

Exceeds power line 
capacity range

Please contact the after-sales 
service center.

Molded case circuit 
breaker abnormal 
trip

Replace the molded case circuit 
breaker.

271

Sayfa 273

No.
Fault Name
Possible Cause
Troubleshooting

1
Charging 
Overvoltage2

2
Charging 
Overvoltage3

3
Discharge 
Undervoltage3

1. 

Leave the unit powered off and 
idle for 5 minutes, then restart 
and check if the fault persists;

•

Excessive cell 
voltage/total 
voltage

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

Abnormal voltage 
sensing line
•

1. 

Leave the unit powered off and 
idle for 5 minutes, then restart 
and check if the fault persists;

•

Excessive cell 
voltage/total 
voltage

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

Abnormal voltage 
sensing line
•

1. 

Leave the unit powered off and 
idle for 5 minutes, then restart 
and check if the fault persists;

2. 

Determine the inverter's 
working status, check if it is not 
charging the battery due to 
issues like working mode, and 
try charging the battery via the 
inverter to observe if the fault is 
resolved.

•

Insufficient cell 
voltage/total 
voltage

Abnormal voltage 
sensing line
•

3. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

272

Sayfa 274

No.
Fault Name
Possible Cause
Troubleshooting

4
Discharge 
Undervoltage2

5
Cell 
Overvoltage2

6
Cell 
Undervoltage2
Cell undervoltage

1. 

Leave the unit powered off and 
idle for 5 minutes, then restart 
and check if the fault persists;

2. 

Determine the inverter's 
working status, check if it is not 
charging the battery due to 
issues like working mode, and 
try charging the battery via the 
inverter to observe if the fault is 
resolved.

•

Insufficient cell 
voltage/total 
voltage

Abnormal voltage 
sensing line
•

3. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

1. 

Leave the unit powered off and 
idle for 5 minutes, then restart 
and check if the fault persists;

•

Excessive cell 
voltage/total 
voltage

Abnormal voltage 
sensing line
•

If the fault is not resolved, contact 
GoodWe after-sales service.

1. 

Leave the unit powered off and 
idle for 5 minutes, then restart 
and check if the fault persists;

2. 

Determine the inverter's 
working status, check if it is not 
charging the battery due to 
issues like working mode, and 
try charging the battery via the 
inverter to observe if the fault is 
resolved.

3. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

273

Sayfa 275

No.
Fault Name
Possible Cause
Troubleshooting

7
Significant Cell 
Voltage 
Variation2

8
Charging 
Overcurrent2

9
Discharge 
Overcurrent2

10
Battery Cell 
High 
Temperature2

Restart the battery and wait for 
12 hours.
1. 

Significant cell 
voltage variation

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

•

Excessive charging 
current, abnormal 
battery current 
limiting: Sudden 
changes in 
temperature and 
voltage values

1. 

Leave the unit powered off and 
idle for 5 minutes, then restart 
and check if the fault persists;

Abnormal inverter 
response
•

2. 

Check if the inverter is set to an 
excessive power level, causing it 
to exceed the battery's rated 
operating current;

•

Excessive 
discharge current, 
abnormal battery 
current limiting: 
Sudden changes in 
temperature and 
SOC values

3. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

Abnormal inverter 
response
•

1. 

Leave the unit powered off and 
idle for 30 minutes, then restart 
and check if the fault persists;

Excessive cell 
temperature
•

•

Abnormal 
temperature 
sensor

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

274

Sayfa 276

No.
Fault Name
Possible Cause
Troubleshooting

11
Battery Cell 
Low 
Temperature2

12
Charging 
Overtemperatu
re2

13
Charging Low 
Temperature2

14
Discharge 
Overtemperatu
re2

•

Excessively low 
ambient 
temperature

1. 

Leave the unit powered off and 
idle for 30 minutes, then restart 
and check if the fault persists;

•

Abnormal 
temperature 
sensor

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

1. 

Leave the unit powered off and 
idle for 30 minutes; then restart 
and check if the fault persists;

Excessive cell 
temperature
•

•

Abnormal 
temperature 
sensor

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

•

Excessively low 
ambient 
temperature

1. 

Leave the unit powered off and 
idle for 30 minutes; then restart 
and check if the fault persists;

•

Abnormal 
temperature 
sensor

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

1. 

Leave the unit powered off and 
idle for 30 minutes; then restart 
and check if the fault persists;

Excessive cell 
temperature
•

•

Abnormal 
temperature 
sensor

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

275

Sayfa 277

No.
Fault Name
Possible Cause
Troubleshooting

15
Discharge Low 
Temperature2

16
Significant Cell 
Temperature 
Variation2

17
Precharge 
Disabled

18
Battery 
Tripping 
Battery Trip

•

Excessively low 
ambient 
temperature

1. 

Leave the unit powered off and 
idle for 30 minutes; then restart 
and check if the fault persists;

•

Abnormal 
temperature 
sensor

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

1. 

Leave the unit powered off and 
idle for 30 minutes; then restart 
and check if the fault persists;

Significant cell 
temperature 
variation

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

1. 

Leave the unit powered off and 
idle for 5 minutes, then restart 
and check if the fault persists;

Precharge MOS 
closing failure

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

Leave idle for 10 minutes, then 
re-close to recover;
1. 

2. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

276

Sayfa 278

No.
Fault Name
Possible Cause
Troubleshooting

19
Battery and 
Inverter Comm 
Failure

20
Specific 
Failures

21
Cluster Parallel 
Failure

22
Application 
Software 
Failure

23
Microelectronic 
Failure

24
Main Control 
Overload

25
SN Anomaly
Existence of batteries 
with identical SN

26
Circuit Breaker 
Anomaly

1. 

Confirm the communication 
cable wiring sequence and DC 
cable are correct, and check for 
continuity.

Battery and Inverter 
Comm Failure

Restart the inverter and the 
battery.
2. 

3. 

If the fault is not resolved, 
contact GoodWe after-sales 
service.

Battery specific 
failure

Please contact the after-sales 
service center.

Check the reliability of the master-
slave harness communication 
connection
Please contact the after-sales 
service center.

Slave cluster loss of 
communication
Cluster parallel 
failure

Software self-test 
failure

Please contact the after-sales 
service center

Electronic 
component failure

Please contact the after-sales 
service center

Stop charging. If it does not 
recover automatically, please 
contact a professional technician 
to restart the system.

Exceeding the power 
line's load capacity

Please contact the after-sales 
service center

Molded case circuit 
breaker abnormal 
trip

Replace the molded case circuit 
breaker

277

Sayfa 279

No.
Fault Name
Possible Cause
Troubleshooting

27
Circuit Breaker 
Welding Fault

28
Fire 
Suppression 
System 
Triggered 

29
Air Conditioner 
Fault

30
Door Access 
Fault

31
Emergency 
Stop Triggered

32
PACK Fan Fault
PACK fan locked 
rotor or unable to 
operate

8.5.3 Post-Fault Clearance Processing

In an energy storage system, after certain faults are handled, additional processing is 
required for the system to resume normal operation.

8.5.3.1 Clear AFCI Fault Warning

Molded case circuit 
breaker fault or 
auxiliary circuit 
breaker fault

Replace the molded case circuit 
breaker or replace the auxiliary 
circuit breaker
 

Internal system 
thermal runaway or 
accidental fire 
suppression trigger

Please contact the after-sales 
service center

Abnormal fault 
occurred within the 
air conditioning 
system

Please contact the after-sales 
service center
 

Door abnormally 
opened or door 
access sensor 
damaged

Close the door or replace the door 
access sensor

Emergency stop 
pressed or 
emergency stop 
button damaged

Replace the emergency stop 
button

Replace the corresponding PACK 
fan

278

Sayfa 280

Software Used: SolarGo APP
Clear Method:

Via [Home] > [Settings] > [Advanced Settings] > [DC Arc Detection].
1. 

Click the [Clear AFCI Fault Alarm] button.
2. 

279

Sayfa 281

9 technical parameter

9.1 Inverter Parameters

Technical Data
GW15K-
ET

Battery Input Data

Battery Type 
Li-Ion
Li-Ion
Li-Ion
Li-Ion
Li-Ion

Nominal Battery Voltage 
(V) 
500
500
500
500
500

Battery voltage range (V) 
200~800
200~800
200~800
200~800
200~800

Start-up Voltage (V) 
200
200
200
200
200

Number of Battery Input 
1
1
2
2
2

Max. Continuous Charging 
Current (A) 
50
50
50×2
50×2
50×2

Max. Continuous 
Discharging Current (A) 
50
50
50×2
50×2
50×2

Max Charge Power (W) 
15000
20000
25000
30000
30000

Max Discharge Power (W) 
15000
20000
25000
30000
30000

PV String Input Data
 
 
 

Max. Input Power (W)*1 
22500
30000
37500
45000
45000

Max. Input Voltage (V)*2 
1000
1000
1000
1000
1000

MPPT Operating Voltage 
Range (V) 
200~850 
200~850 
200~850 
200~850 
200~850 

MPPT Voltage Range at 
Nominal Power (V) 
400~850 
400~850 
450~850 
450~850 
450~850 

Start-up Voltage (V) 
200
200
200
200
200

GW20K-
ET

GW25K-
ET

GW29.9
K-ET

GW30K-
ET

280

Sayfa 282

Technical Data
GW15K-
ET

Nominal Input Voltage (V) 
620
620
620
620
620

Max. Input Current per 
MPPT (A) 
30
30
30
30
30

Max. Short Circuit Current 
per MPPT (A) 
38
38
38
38
38

Max. Backfeed Current to 
The Array (A)
0
0
0
0
0

Number of MPPT 
2
2
3
3
3

Number of Strings per 
MPPT 
2/2
2/2
2/2/2
2/2/2
2/2/2

AC Output Data (On-grid)
 
 
 

Nominal Output Power (W) 
15000
20000
25000
29900
30000

Max. Output Power (W) 
15000
20000
25000
29900
30000

Nominal Output Power at 
40 ℃(W) *14
15000
20000
25000
29900
30000

Max. Output Power at 40 ℃ 
(W)*14
15000
20000
25000
29900
30000

Nominal Apparent Power 
Output to Utility Grid (VA) 
15000
20000
25000
29900
30000

Max. Apparent Power 
Output to Utility Grid (VA)*3 
*15
16500
22000
27500
29900
33000

Nominal Apparent Power 
from Utility Grid(VA) 
15000
20000
25000
30000
30000

Max. Apparent Power from 
Utility Grid (VA) *12
15000
20000
25000
30000
30000

GW20K-
ET

GW25K-
ET

GW29.9
K-ET

GW30K-
ET

281

Sayfa 283

Technical Data
GW15K-
ET

Nominal Output Voltage (V) 
380/400, 
3L/N/PE
380/400, 
3L/N/PE
380/400, 
3L/N/PE
380/400, 
3L/N/PE
380/400, 
3L/N/PE

Output Voltage Range 
(V)*4 
0~300
0~300
0~300
0~300
0~300

Nominal AC Grid Frequency 
(Hz) 
50/60
50/60
50/60
50/60
50/60

AC Grid Frequency Range 
(Hz) 
45~65
45~65
45~65
45~65
45~65

Max. AC Current Output to 
Utility Grid (A) *11 
23.9
31.9
39.9
43.3
47.8

Max. AC Current From 
Utility Grid (A) *13
22.7
30.3
37.9
45.3
45.5

Nominal AC Current From 
Utility Grid (A) 

Max. Output Fault Current 
(Peak and Duration) (A) 

Inrush Current (Peak and 
Duration) (A) 

Nominal Output Current 
(A)*5 
21.7
29
36.2
43.3
43.5

GW20K-
ET

GW25K-
ET

GW29.9
K-ET

GW30K-
ET

21.7 
@230V
22.7 
@220V

29.0 
@230V
30.3 
@220V

36.2 
@230V
37.9 
@220V

43.3 
@230V
45.3 
@220V

43.5 
@230V
45.5 
@220V

241.5A@
126ms
241.5A@
126ms
241.5A@
126ms
241.5A@
126ms
241.5A@
126ms

264A@5
3us
264A@5
3us
264A@5
3us
264A@5
3us
264A@5
3us

282

Sayfa 284

Technical Data
GW15K-
ET

Power Factor 

Max. Total Harmonic 
Distortion 
≤3.05%
≤3.05%
≤3.05%
≤3.05%
≤3.05%

Maximum Output 
Overcurrent Protection (A) 
94
94
94
94
94

AC Output Data (Back-up)

Back-up Nominal Apparent 
Power (VA) 
15000
20000
25000
29900
30000

Max. Output Apparent 
Power without Grid(VA)*6 

Max. Output Apparent 
Power with Grid (VA) 
15000
20000
25000
29900
30000

Nominal Output Current 
(A) 
22.7
30.3
37.9
45.5
45.5

Max. Output Current (A) 

Max. Output Fault Current 
(Peak and Duration) (A) 
94
94
94
94
94

GW20K-
ET

GW25K-
ET

GW29.9
K-ET

GW30K-
ET

~1 
(Adjusta
ble 
from0.8 
leading~
0.8 
lagging
)

~1 
(Adjusta
ble 
from0.8 
leading~
0.8 
lagging
)

~1 
(Adjusta
ble 
from0.8 
leading~
0.8 
lagging
)

~1 
(Adjusta
ble 
from0.8 
leading~
0.8 
lagging
)

~1 
(Adjusta
ble 
from0.8 
leading~
0.8 
lagging
)

15,000(1
8,000@6
0s , 
24,000@
3s) 

20,000(2
4,000@6
0s , 
32,000@
3s) 

25,000(3
0,000@6
0s) 

30,000(3
6,000@6
0s) 

30,000(3
6,000@6
0s) 

22.7(27.3
@60s, 
36.4@3s) 
 

30.3(36.4
@60s, 
48.5@3s) 
 

37.9(45.5
@60s) 

45.5(54.5
@60s) 

45.5(54.5
@60s) 

283

Sayfa 285

Technical Data
GW15K-
ET

Inrush Current (Peak and 
Duration) (A) 

Maximum Output 
Overcurrent Protection (A) 
94
94
94
94
94

Nominal Output Voltage (V) 
380/400 
380/400 
380/400 
380/400 
380/400 

Nominal Output Frequency 
(Hz) 
50/60 
50/60 
50/60 
50/60 
50/60 

Output THDv (@Linear 
Load) 
<3% 
<3% 
<3% 
<3% 
<3% 

Efficiency
 
 
 
 

Max. Efficiency 
98.0%
98.0%
98.0%
98.0%
98.0%

European Efficiency 
97.5%
97.5%
97.5%
97.5%
97.5%

Max. Battery to AC 
Efficiency 
97.5%
97.5%
97.5%
97.5%
97.5%

MPPT Efficiency 
99.9%
99.9%
99.9%
99.9%
99.9%

Protection

PV String Current 
Monitoring 

PV Insulation Resistance 
Detection 

Residual Current 
Monitoring 

PV Reverse Polarity 
Protection 

Battery Reverse Polarity 
Protection 

GW20K-
ET

GW25K-
ET

GW29.9
K-ET

GW30K-
ET

264@53
us 

264@53
us 

264@53
us 

264@53
us 

264@53
us 

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

284

Sayfa 286

Technical Data
GW15K-
ET

Anti-islanding Protection 
Integrat
ed

AC Overcurrent Protection 
Integrat
ed

AC Short Circuit Protection 
Integrat
ed

AC Overvoltage Protection 
Integrat
ed

DC Switch*7 
Integrat
ed

DC Surge Protection 
Type II
Type II
Type II
Type II
Type II

AC Surge Protection 
Type III
Type III
Type III
Type III
Type III

AFCI*16
Optional
Optional
Optional
Optional
Optional

Rapid Shutdown 
Optional
Optional
Optional
Optional
Optional

Remote Shutdown 
Integrat
ed

General Data

Operating Temperature 
Range (℃) 
-35~+60
-35~+60
-35~+60
-35~+60
-35~+60

Operating Environment
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor

Relative Humidity 
0~95% 
0~95% 
0~95% 
0~95% 
0~95% 

Max. Operating Altitude 
(m) 
4000
4000
4000
4000
4000

Cooling Method 

GW20K-
ET

GW25K-
ET

GW29.9
K-ET

GW30K-
ET

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Integrat
ed

Smart 
Fan 
Cooling 

Smart 
Fan 
Cooling 

Smart 
Fan 
Cooling 

Smart 
Fan 
Cooling 

Smart 
Fan 
Cooling 

285

Sayfa 287

Technical Data
GW15K-
ET

Display 

Communication with BMS 
RS485 / 
CAN 

Communication with Meter 
RS485 
RS485 
RS485 
RS485 
RS485 

Communication with Portal 

Weight (kg) 
48
48
54
54
54

Dimension W×H×D (mm) 
520×660
×220 

Noise Emission (dB) 
<45 
<45 
<45 
<60 
<60 

Topology 
Non-
isolated 

Self-consumption at Night 
(W) *8 
<15 
<15 
<15 
<15 
<15 

Ingress Protection Rating 
IP66 
IP66 
IP66 
IP66 
IP66 

DC Connector 

AC Connector 
OT 
OT 
OT 
OT 
OT 

Environmental Category 
4K4H 
4K4H 
4K4H 
4K4H 
4K4H 

Pollution Degree 
III 
III 
III 
III 
III 

Overvoltage Category 
DC II / 
AC III 

GW20K-
ET

GW25K-
ET

GW29.9
K-ET

GW30K-
ET

LED, 
WLAN+A
PP 

LED, 
WLAN+A
PP 

LED, 
WLAN+A
PP 

LED, 
WLAN+A
PP 

LED, 
WLAN+A
PP 

RS485 / 
CAN 

RS485 / 
CAN 

RS485 / 
CAN 

RS485 / 
CAN 

WiFi+LA
N+Bluet
ooth

WiFi+LA
N+Bluet
ooth

WiFi+LA
N+Bluet
ooth

WiFi+LA
N+Bluet
ooth

WiFi+LA
N+Bluet
ooth

520×660
×220 

520×660
×220 

520×660
×220 

520×660
×220 

Non-
isolated 

Non-
isolated 

Non-
isolated 

Non-
isolated 

Stäubli 
Electrical 
Connect
ors AG 

Stäubli 
Electrical 
Connect
ors AG 

Stäubli 
Electrical 
Connect
ors AG

Stäubli 
Electrical 
Connect
ors AG

Stäubli 
Electrical 
Connect
ors AG

DC II / 
AC III 

DC II / 
AC III 

DC II / 
AC III 

DC II / 
AC III 

286

Sayfa 288

Technical Data
GW15K-
ET

Protective Class 
I 
I 
I 
I 
I 

Storage Temperature (℃) 
-45~+85 
-45~+85 
-45~+85 
-45~+85 
-45~+85 

The Decisive Voltage Class 
(DVC) 

Mounting Method 

Active Anti-islanding 
Method 

Type of Electrical Supply 
System 

Country of Manufacture
China 
China 
China 
China 
China 

*1: In Australia, for most PV modules, the max. input power can achieve 2*Pn. For 
example, the max. input power of the GW15K-ET can achieve 30000W. Additionally, 
the Max. Input Power is not continuous for 1.5*normal power. 
*2: For a 1000V system, the maximum operating voltage is 950V.  
*3: According to local grid regulations.  
*4: Output Voltage Range: phase voltage. 
*5: For a 380V grid, the Nominal Output Current is 22.7A for GW15K-ET, 30.3A for 
GW20K-ET, 37.9A for GW25K-ET, 45.3A for GW29.9K-ET, and 45.5A for GW30K-ET.  
*6: Can only be reached if PV and battery power are sufficient.  
*7: DC Switch: GHX6-55P (for Australia).  
*8: No Backup Output.  
*9: AFDPF: Active Frequency Drift with Positive Feedback, AQDPF: Active Q Drift with 
Positive Feedback.  
*10: Not all certifications & standards are listed; check the official website for details.  

GW20K-
ET

GW25K-
ET

GW29.9
K-ET

GW30K-
ET

Battery
:C 
PV:C 
AC:C 
Com:A 

Battery
:C 
PV:C 
AC:C 
Com:A 

Battery
:C 
PV:C 
AC:C 
Com:A 

Battery
:C 
PV:C 
AC:C 
Com:A 

Battery
:C 
PV:C 
AC:C 
Com:A 

Wall 
Mounted 
 

Wall 
Mounted 
 

Wall 
Mounted 
 

Wall 
Mounted 
 

Wall 
Mounted 
 

AFDPF + 
AQDPF 
*9 

AFDPF + 
AQDPF 
*9 

AFDPF + 
AQDPF 
*9 

AFDPF + 
AQDPF 
*9 

AFDPF + 
AQDPF 
*9 

Three 
phase 
Grid 

Three 
phase 
Grid 

Three 
phase 
Grid 

Three 
phase 
Grid 

Three 
phase 
Grid 

287

Sayfa 289

*11: For a 380V grid, the Max. AC Current Output to Utility Grid is 25A for GW15K-ET, 
33.3A for GW20K-ET, 41.7A for GW25K-ET, 49.8A for GW29.9K-ET, and 50A for GW30K-
ET.  
*12: When the load is connected to the inverter's backup port, the Max. Apparent 
Power from Utility Grid can reach 22.5kVA for GW15K-ET, 30kVA for GW20K-ET, 33kVA 
for GW25K-ET, 33kVA for GW29.9K-ET, and 33kVA for GW30K-ET respectively. 
*13: When the load is connected to the inverter's backup port, the Max. AC Current 
From Utility Grid can reach 34A for GW15K-ET, 45A for GW20K-ET, 50A for GW25K-ET, 
50A for GW29.9K-ET, and 50A for GW30K-ET respectively. 
*14: Nominal Output Power at 40℃(W) and Max. Output Power at 40℃(W) are only 
for Brazil. 
*15: For Austria, Max. Output Power (W) is 15K for GW15K-ET, 20K for GW20K-ET, 25K 
for GW25K-ET, 29.9K for GW29.9K-ET, and 30K for GW30K-ET. 
*16: For Brazil, AFCI is integrated.

Technical Data
GW12KL-ET
GW18KL-ET
GW20K-ET
GW30K-ET

Battery Input Data

Battery Type
Li-Ion
Li-Ion
Li-Ion
Li-Ion

Nominal Battery Voltage 
(V)
500
500
500
500

Battery Voltage Range (V)
112~650
112~650
200~800
200~800

Start-up Voltage (V) 
112
112
180
180

Number of Battery Input 
1
2
1
2

Max. Continuous 
Charging Current (A) 
50
50*2
50
50*2

Max. Continuous 
Discharging Current (A) 
50
50*2
50
50*2

Max Charge Power (kW) 
12
18
20
30

Max Discharge Power 
(kW) 
12
18
20
30

PV String Input Data

288

Sayfa 290

Technical Data
GW12KL-ET
GW18KL-ET
GW20K-ET
GW30K-ET

Max. Input Power (kW)
24
36
30
45

Max. Input Voltage (V)*1 
800
800
1000
1000

MPPT Operating Voltage 
Range (V) 
200~650
200~650
200~850
200~850

MPPT Voltage Range at 
Nominal Power (V) 
260~650 
260~650 
400~850 
450~850 

Start-up Voltage (V) 
200
200
200
200

Nominal Input Voltage (V) 
380
380
620
620

Max. Input Current per 
MPPT (A) 
30
30
30
30

Max. Short Circuit Current 
per MPPT (A) 
38
38
38
38

Max. Backfeed Current to 
The Array (A)
0
0
0
0

Number of MPPT Trackers
2
3
2
3

Number of Strings per 
MPPT 
2/2
2/2/2
2/2
2/2/2

AC Output Data (On-grid)

Nominal Output Power 
(kW) 
12
18
20
30

Max. Output Power (kW) 
12
18
20
30

Nominal Output Power at 
40 ℃(kW) *8
12
18
20
30

Max. Output Power at 40 
℃ (kW)*8
12
18
20
30

289

Sayfa 291

Technical Data
GW12KL-ET
GW18KL-ET
GW20K-ET
GW30K-ET

Nominal Apparent Power 
Output to Utility Grid 
(kVA) 

Max. Apparent Power 
Output to Utility Grid (kVA)
13.2
19.8
22
33

Nominal Apparent Power 
from Utility Grid(kVA) 
12
18
20
30

Max. Apparent Power 
from Utility Grid (kVA) *6
12
18
20
30

Nominal Output Voltage 
(V) 

Output Voltage Range 
(V)*2
0~165
0~165
0~300
0~300

Nominal AC Grid 
Frequency (Hz) 
60
60
60
60

AC Grid Frequency Range 
(Hz) 
55~65
55~65
45~65
45~65

Max. AC Current Output 
to Utility Grid (A) 
34.6
52
33.3
50

Max. AC Current From 
Utility Grid (A) *7
31.5
47
30.3
45.5

Nominal AC Current From 
Utility Grid (A) 
31.5
47
30.3
45.5

Max. Output Fault Current 
(Peak and Duration) (A) 

Inrush Current (Peak and 
Duration) (A) 
264A@53us
264A@53us
264A@53us
264A@53us

Nominal Output Current 
(A)
31.5
47
30.3
45.5

12
18
20
30

220, 
3L/N/PE
220, 
3L/N/PE
380, 
3L/N/PE
380, 
3L/N/PE

241.5A@126
ms

241.5A@126
ms

241.5A@126
ms

241.5A@126
ms

290

Sayfa 292

Technical Data
GW12KL-ET
GW18KL-ET
GW20K-ET
GW30K-ET

Power Factor 

Max. Total Harmonic 
Distortion 
<3%
<3%
<3%
<3%

Maximum Output 
Overcurrent Protection 
(A) 

AC Output Data (Back-up)

Back-up Nominal 
Apparent Power (kVA) 
12
18
20
30

Max. Output Apparent 
Power without 
Grid(kVA)*3

Max. Output Apparent 
Power with Grid (kVA) 
12
18
20
30

Nominal Output Current 
(A) 
31.5
47
30.3
45.5

Max. Output Current (A) 
31.5(37.8@6
0s, 50.4@3s)
47(56.4@60
s)

Max. Output Fault Current 
(Peak and Duration) (A) 
94
94
94
94

Inrush Current (Peak and 
Duration) (A) 
264@53us 
264@53us 
264@53us 
264@53us 

Maximum Output 
Overcurrent Protection 
(A) 

~1 
(Adjustable 
from0.8 
leading~0.8 
lagging)

~1 
(Adjustable 
from0.8 
leading~0.8 
lagging)

~1 
(Adjustable 
from0.8 
leading~0.8 
lagging)

~1 
(Adjustable 
from0.8 
leading~0.8 
lagging)

94
94
94
94

12.0(14.4@6
0s , 
19.2@3s)

20.0(24.0@6
0s , 
32.0@3s)

18.0(21.6@6
0s)

30.0(36.0@6
0s) 

30.3(36.4@6
0s, 48.5@3s)
45.5(54.5@6
0s) 

94
94
94
94

291

Sayfa 293

Technical Data
GW12KL-ET
GW18KL-ET
GW20K-ET
GW30K-ET

Nominal Output Voltage 
(V) 

Nominal Output 
Frequency (Hz) 
60
60
60
60

Output THDv (@Linear 
Load) 
<3%
<3%
<3%
<3%

Switching from Grid 
Connected Mode to 
Standalone Mode

Switching from 
standalone mode to Grid 
connected mode

Efficiency

Max. Efficiency 
98.0%
98.0%
98.0%
98.0%

European Efficiency 
97.5%
97.5%
97.5%
97.5%

Max. Battery to AC 
Efficiency 
97.5%
97.5%
97.5%
97.5%

Protection

PV String Current 
Monitoring 
Integrated
Integrated
Integrated
Integrated

PV Insulation Resistance 
Detection 
Integrated
Integrated
Integrated
Integrated

Residual Current 
Monitoring 
Integrated
Integrated
Integrated
Integrated

PV Reverse Polarity 
Protection 
Integrated
Integrated
Integrated
Integrated

Battery Reverse Polarity 
Protection 
Integrated
Integrated
Integrated
Integrated

220, 
3L/N/PE
220, 
3L/N/PE
380, 
3L/N/PE
380, 
3L/N/PE

20ms
20ms
20ms
20ms

20ms
20ms
20ms
20ms

292

Sayfa 294

Technical Data
GW12KL-ET
GW18KL-ET
GW20K-ET
GW30K-ET

Anti-islanding Protection 
Integrated
Integrated
Integrated
Integrated

AC Overcurrent 
Protection 
Integrated
Integrated
Integrated
Integrated

AC Short Circuit 
Protection 
Integrated
Integrated
Integrated
Integrated

AC Overvoltage 
Protection 
Integrated
Integrated
Integrated
Integrated

DC Switch
Integrated
Integrated
Integrated
Integrated

DC Surge Protection 
Type II
Type II
Type II
Type II

AC Surge Protection 
Type III
Type III
Type III
Type III

AFCI 
Integrated
Integrated
Integrated
Integrated

Rapid Shutdown 
Optional
Optional
Optional
Optional

Remote Shutdown 
Integrated
Integrated
Integrated
Integrated

General Data

Operating Temperature 
Range (℃) 
-35~+60 
-35~+60 
-35~+60 
-35~+60 

Storage Temperature (℃) 
-45~+85
-45~+85
-45~+85
-45~+85

Relative Humidity 
0~95% 
0~95% 
0~95% 
0~95% 

Max. Operating Altitude 
(m) 
4000
4000
4000
4000

Cooling Method 
Smart Fan 
Cooling

User Interface
LED, 
WLAN+APP

Communication with BMS 
RS485 / CAN
RS485 / CAN
RS485 / CAN
RS485 / CAN

Smart Fan 
Cooling

Smart Fan 
Cooling

Smart Fan 
Cooling

LED, 
WLAN+APP

LED, 
WLAN+APP

LED, 
WLAN+APP

293

Sayfa 295

Technical Data
GW12KL-ET
GW18KL-ET
GW20K-ET
GW30K-ET

Communication

Communication Protocols

Weight (kg) 
48
54
48
54

Dimension W×H×D (mm) 
520×660×22
0 
520×660×22
0 
520×660×22
0 
520×660×22
0 

Noise Emission (dB) 
<45
<60
<45
<60

Topology 
Non-
isolated

Self-consumption at Night 
(W) *4
<15
<15
<15
<15

Ingress Protection Rating 
IP66
IP66
IP66
IP66

Anti-corrosion Class
C4
C4
C4
C4

DC Connector 
MC4
MC4
MC4
MC4

AC Connector 
OT
OT
OT
OT

Environmental Category 
4K4H
4K4H
4K4H
4K4H

Pollution Degree 
III
III
III
III

Overvoltage Category 
DC II / AC III
DC II / AC III
DC II / AC III
DC II / AC III

Protective Class 
I
I
I
I

RS485, 
WiFi+LAN+B
luetooth, 
4G+Bluetoo
th(Optional)

RS485, 
WiFi+LAN+B
luetooth, 
4G+Bluetoo
th(Optional)

RS485, 
WiFi+LAN+B
luetooth, 
4G+Bluetoo
th(Optional)

RS485, 
WiFi+LAN+B
luetooth, 
4G+Bluetoo
th(Optional)

Modbus-
RTU 
(SunSpec 
Compliant), 
Modbus-
TCP

Modbus-
RTU 
(SunSpec 
Compliant), 
Modbus-
TCP

Modbus-
RTU 
(SunSpec 
Compliant), 
Modbus-
TCP

Modbus-
RTU 
(SunSpec 
Compliant), 
Modbus-
TCP

Non-
isolated

Non-
isolated

Non-
isolated

294

Sayfa 296

Technical Data
GW12KL-ET
GW18KL-ET
GW20K-ET
GW30K-ET

The Decisive Voltage Class 
(DVC) 

Mounting Method 
Wall 
Mounted

Active Anti-islanding 
Method 

Type of Electrical Supply 
System 

Country of Manufacture
China
China
China
China

*1: For a 1000V system, the maximum operating voltage is 950V.  
*2: Output Voltage Range: phase voltage.  
*3: Can only be reached if PV and battery power are sufficient.  
*4: No Backup Output.  
*5: AFDPF: Active Frequency Drift with Positive Feedback, AQDPF: Active Q Drift with 
Positive Feedback.  
*6: When the load is connected to the inverter's backup port, the Max. Apparent 
Power from Utility Grid can reach 18kVA for GW12KL-ET, 19.8kVA for GW18KL-ET, 

30kVA for GW20K-ET, and 33kVA for GW30K-ET respectively.  
*7: When the load is connected to the inverter's backup port, the Max. AC Current 
From Utility Grid can reach 47.2A for GW12KL-ET and 52A for GW18KL-ET; and can 
reach 45A for GW20K-ET and 50A for GW30K-ET respectively. 
*8: Nominal Output Power at 40℃(W) and Max. Output Power at 40℃(W) are only for 
Brazil.

9.2 Battery Parameters

9.2.1 Lynx C Series 60kWh C&l Battery System

Battery:C 
PV:C 
AC:C 
Com:A 

Battery:C 
PV:C 
AC:C 
Com:A 

Battery:C 
PV:C 
AC:C 
Com:A 

Battery:C 
PV:C 
AC:C 
Com:A 

Wall 
Mounted

Wall 
Mounted

Wall 
Mounted

FDPF + 
AQDPF *5

FDPF + 
AQDPF *5

AFDPF + 
AQDPF *5

AFDPF + 
AQDPF *5

Three phase 
Grid 

Three phase 
Grid 

Three phase 
Grid 

Three phase 
Grid 

295

Sayfa 297

Technical Parameters
GW60KWH-D-10
GW60KWH-D-
10(EXTENSION)

Battery Data

Usable Energy (kWh)*1
60

Cell Type
LFP (LiFePO4)

Cell Capacity (Ah)
100

Pack Nominal Energy (kWh)
5.76

Number of Packs
11

Nominal Voltage (V)
633.6

Operating Voltage Range (V)
554.4~712.8

Max. Charge/ Discharge 
Current (A)*2
96

Max. Charge/ Discharge 
Rate*2
0.96C

Cycle Life*3
≥5000

Depth of Discharge
100%

Efficiency

Round-trip Efficiency
95%

General Data
Operating Temperature 
Range (℃)
Charge: 0~+55; Discharge: -25~+55

Storage Temperature (℃)

Relative Humidity
0~95%

Max. Operating Altitude (m)
3000

Heating & Cooling
Air Conditioner

User Interface
LED indicator

Communication Interface
CAN

Communication Protocol
CAN

Weight (kg)
appro.1029.5
appro.972

Dimension  (W×H×D mm)
1108×2050× 1111.5
808×2050× 1111.5

Ingress Protection Rating
IP55(Battery Cabinet)

Anti-Corrosion*4
C4 (Optional upgrade to C5)

Fire Suppression
Perfluoro

Certification*5

0~+35(<One Year);-20~0(≤One 

Month);+35~+40(≤One Month)

296

Sayfa 298

Technical Parameters
GW60KWH-D-10
GW60KWH-D-
10(EXTENSION)

Safety Regulation
IEC62619/63056, IEC60730-1, IEC/EN62477-1, 
IEC62040-1

EMC
EN IEC61000-6-1, EN IEC61000-6-2, EN IEC61000-6-
3, EN IEC61000-6-4

*1: Test conditions, 100% DOD, 0.5C charge & discharge at +25±2 °C for battery 
system at beginning life. System Usable Energy may vary with different 
Inverter.                           
*2: Actual Dis-/Charge Current and power derating will occur related to Cell 
Temperature and SOC.And, Max C-rate continuous time is affected by SOC, Cell 
Temperature, Atmosphere environment temperature ,Air-conditioner refrigeration 
capacity.
*3: Based on Cell test condition of 25±2℃, 0.5C/0.5C and 80% EOL.   
*4: Excluding locks.
*5: Not all certifications & standards listed, check the official website for detail.

9.2.2 BAT-S Series 15.3-56.3kWh High Voltage Battery

Technical Data
GW15.3-BAT-I-G11
GW20.4-BAT-I-G11

Battery System

Cell Type
LFP (LiFePO4)

Capacity (Ah)
100

Pack Type/model
GW5.1-PACK-I-G10

Pack Nominal Energy (kWh)
5.12

Pack Configuration
1P48S
1P64S

Pack Weight(kg)
42.5

Number of Packs
3
4

Nominal Energy (kWh)
15.3
20.4

Usable Energy (kWh) *1
15
20

297

Sayfa 299

Technical Data
GW15.3-BAT-I-G11
GW20.4-BAT-I-G11

Nominal Voltage (V)
153.6
204.8

Operating Voltage Range (V)
137.76~173.28
183.68~231.04

Charging Operating Temperature 
Range(℃)
0~+55

Discharging Operating 
Temperature Range(℃)
-20~+55

Max. Charge/ Disharge Current (A) 
*2
100/110

Max. Charge/ Discharge Rate *2
1C/1.1C

Max. Charge/ Discharge power 
(kW) *2
15.3/16.8
20.4/22.4

Cycle Life
6000 (25±2°C, 0.5C, 90%DOD, 70%EOL)

Depth of Discharge
100%

Efficiency

Round-trip Efficiency
96%@100%DOD, 0.2C, 25±2℃

General Data

Operating Temperature Range (℃)
0~40℃

Storage Temperature (℃)
+35~+45 (<6 Months);-20~+35 (<1 Year)

Relative Humidity
5~85%, No condensation

Max. Operating Altitude (m)
3000

Cooling Method
Natural Cooling

User Interface
LED

Communication
CAN (RS485 Optional)

298

Sayfa 300

Technical Data
GW15.3-BAT-I-G11
GW20.4-BAT-I-G11

Weight-stacked(kg)
158
203

Dimension-stacked (W×H×D mm)
481*649*552
481*787*552

Ingress Protection Rating
IP20

Fire safety equipment
Aerosol, Pack Level

Certification*3

Safety Regulation
For details, please visit our official website

EMC
For details, please visit our official website

Note:

Test conditions, 100% DOD, 0.2C charge & discharge at +25±2 °C for battery system 
at beginning life. System Usable Energy may vary with system configuration.  
1. 

2. 

Actual Dis-/Charge Current and power derating will occur related to Cell 
Temperature and SOC. And, Max C-rate continuous time is affected by SOC, Cell 
Temperature, Atmosphere environment temperature .

Not all certifications & standards listed, check the official website for detail.
3. 

GW25.6
-BAT-I-
G10

GW30.7
-BAT-I-
G10

GW35.8
-BAT-I-
G10

GW40.9
-BAT-I-
G10

GW46.0-
BAT-I-
G10

GW51.2-
BAT-I-
G10

GW56.
3-BAT-
I-G10

Technical 
Data

Battery System

Cell Type
LFP (LiFePO4)

Capacity 
(Ah)
100

Pack 
Type/model
GW5.1-PACK-I-G10

299

Sayfa 301

GW25.6
-BAT-I-
G10

GW30.7
-BAT-I-
G10

GW35.8
-BAT-I-
G10

GW40.9
-BAT-I-
G10

GW46.0-
BAT-I-
G10

GW51.2-
BAT-I-
G10

GW56.
3-BAT-
I-G10

Technical 
Data

Pack 
Nominal 
Energy 
(kWh)

5.12

Pack 
Configuratio
n

1P80S
1P96S
1P112S
1P128S
1P144S
1P160S
1P176S

Pack Weight 
(kg)
42.5

Number of 
Packs
5
6
7
8
9
10
11

Nominal 
Energy 
(kWh)

25.6
30.7
35.8
40.9
46
51.2
56.3

Usable 
Energy 
(kWh) *1

25
30
35
40
45
50
55

Nominal 
Voltage (V)
256
307.2
358.4
409.6
460.8
512
563.2

Operating 
Voltage 
Range (V)

505.12
~635.3
6

229.6~2
88.8
275.52~
346.56
321.44~
404.32
367.36~
462.08
413.28~
519.84
459.2~5
77.6

Charging 
Operating 
Temperatur
e Range (℃)

0~+55

300

Sayfa 302

GW25.6
-BAT-I-
G10

GW30.7
-BAT-I-
G10

GW35.8
-BAT-I-
G10

GW40.9
-BAT-I-
G10

GW46.0-
BAT-I-
G10

GW51.2-
BAT-I-
G10

GW56.
3-BAT-
I-G10

Technical 
Data

Discharging 
Operating 
Temperatur
e Range (℃)

-20~+55

Max. 
Charge/Disc
harge 
Current (A) 
*2

100/110

Max. 
Charge/Disc
harge Rate 
*2

1C/1.1C

Max. 
Charge/Disc
harge Power 
(kW) *2

25.6/28.
1
30.7/33.
7
35.8/39.
4
40.9/44.
9
46.0/50.
6
51.2/56.
3
56.3/61
.9

Cycle Life
6000 (25±2°C, 0.5C, 90% DOD, 70% EOL)

Depth of 
Discharge
1

Efficiency

Round-trip 
Efficiency
96%@100%DOD, 0.2C, 25±2℃

General Data

Operating 
Temperatur
e Range (℃)

0~40℃

301

Sayfa 303

GW25.6
-BAT-I-
G10

GW30.7
-BAT-I-
G10

GW35.8
-BAT-I-
G10

GW40.9
-BAT-I-
G10

GW46.0-
BAT-I-
G10

GW51.2-
BAT-I-
G10

GW56.
3-BAT-
I-G10

Technical 
Data

Storage 
Temperatur
e (℃)

+35°C to +45°C (<6 Months); -20°C to +35°C (<1 Year)

Relative 
Humidity
5-85%, no condensation

Max. 
Operating 
Altitude (m)

3000

Cooling 
Method
Natural Cooling

User 
Interface
LED

Communicat
ion
CAN (RS485 Optional)

Weight-rack 
mounted 
(kg)

-
-
-
-
-
495
540

Weight-
stacked (kg)
248
293
338
383
428
472
517

Dimension-
rack 
mounted 
(W×H×D 
mm)

-
-
-
-
-
543*1815*520

Dimension-
stacked
(W×H×D 
mm)

481*92
5*552
481*10
63*552
481*120
1*552
481*133
9*552
481*147
7*552
481*161
5*552
481*17
53*552

302

Sayfa 304

GW25.6
-BAT-I-
G10

GW30.7
-BAT-I-
G10

GW35.8
-BAT-I-
G10

GW40.9
-BAT-I-
G10

GW46.0-
BAT-I-
G10

GW51.2-
BAT-I-
G10

GW56.
3-BAT-
I-G10

Technical 
Data

Ingress 
Protection 
Rating

IP20

Fire safety 
equipment
Aerosol, Pack Level

Certification *3

Safety 
Regulation
For details, please visit our official website

EMC
For details, please visit our official website

Note:

1. 

Test conditions, 100% DOD, 0.2C charge & discharge at +25±2 °C for battery 
system at beginning life. System Usable Energy may vary with system 
configuration.  

2. 

Actual Dis-/Charge Current and power derating will occur related to Cell 
Temperature and SOC. And, Max C-rate continuous time is affected by SOC, Cell 
Temperature, Atmosphere environment temperature .

Not all certifications & standards listed, check the official website for detail.
3. 

9.2.3 BAT-C Series 61.4-112.6kWh C&I Battery System

GW92.1-BAT-
AC-G10

GW102.4-BAT-
AC-G10

GW112.6-BAT-
AC-G10

Technical Data
GW61.4-BAT-
AC-G10

Battery System

Cell Type
LFP (LiFePO4)

Cell Capacity (Ah)
100

303

Sayfa 305

Technical Data
GW61.4-BAT-
AC-G10

Rated Capacity 
(Ah)
200

Pack Type/model
GW10.2-PACK-ACI-G10

Pack Nominal 
Energy (kWh)
10.24

Pack 
Configuration
2P96S
2P144S
2P160S
2P176S

Pack 
Weight(kg)
<90

Number of Packs
6
9
10
11

Nominal Energy 
(kWh)
61.4
92.1
102.4
112.6

Usable Energy 
(kWh) *1
60
90
100
110

Nominal Voltage 
(V)
307.2
460.8
512
563.2

Operating 
Voltage Range (V)

Charging 
Operating 
Temperature 
Range(℃)

Discharging 
Operating 
Temperature 
Range(℃)

GW92.1-BAT-
AC-G10

GW102.4-BAT-
AC-G10

GW112.6-BAT-
AC-G10

275.52~346.5
6
413.28~519.8
4
459.2~577.6
505.12~635.36

-20~+55

-20~+55

304

Sayfa 306

Technical Data
GW61.4-BAT-
AC-G10

Max. Charge/ 
Discharge 
Current (A) *2

Rated Charge/ 
Discharge 
Current (A) *2

Max. Charge/ 
Discharge Rate *2
0.9C/1.1C

Max. Charge/ 
Discharge power 
(kW) *2

Rated Charge/ 
Discharge power 
(kW) *2

Cycle Life*3
≥6000 times until 70% SOH under 25±2°C.0.5C and 100% DOD

Depth of 
Discharge
100%

Efficiency

Round-trip 
Efficiency*3
96%@100%DOD, 0.2C, 25±2℃

General Data

Operating 
Temperature 
Range (℃)

Storage 
Temperature (℃)
+35~+45 (<6 Months); -20~+35 (<1)

Relative Humidity
0~100%(Condensationless)

GW92.1-BAT-
AC-G10

GW102.4-BAT-
AC-G10

GW112.6-BAT-
AC-G10

180/220

100/100

55.2/67.5
82.9/101.3
92.1/112.6
101.3/123.9

30.7
46.0
51.2
56.3

-20~+55

305

Sayfa 307

Technical Data
GW61.4-BAT-
AC-G10

Max. Operating 
Altitude (m)
4000

Cooling Method
Air Conditioner

User Interface
LED

Communication
CAN (RS485 Optional)

Weight (kg)
<950
<1220
<1310
<1400

Dimension  
 (W×H×Dmm)
1055*2000*1055

Noise Emission 
(dB)
≤70

Ingress 
Protection Rating
IP55
IP55
IP55
IP55

Anti-corrosion 
Class
C4(C5-M Optional)

Fire safety 
equipment*4
Aerosol (Pack&Cabinet Level)

Certification *5

Safety Regulation
IEC62619/IEC63056/IEC60730/IEC62477/VDE2510/ISO13849 
IEC62040/N140/EU 2023/1542/UN38.3

EMC
IEC/EN61000-6-1/2/3/4

GW92.1-BAT-
AC-G10

GW102.4-BAT-
AC-G10

GW112.6-BAT-
AC-G10

306

Sayfa 308

GW92.1-BAT-
AC-G10

GW102.4-BAT-
AC-G10

Technical Data
GW61.4-BAT-
AC-G10

Note:

1. 

Test conditions, 100% DOD, 0.2C charge & discharge at +25±2 °C for battery 
system at beginning life. System Usable Energy may vary with system 
configuration.      

2. 

Actual Dis-/Charge Current and power derating will occur related to Cell 
Temperature and SOC. And, Max C-rate continuous time is affected by SOC, Cell 
Temperature, Atmosphere environment temperature. Rated Charge/ Discharge 
Current & Rated Charge/ Discharge power only for Australia.

For Australian DOD is 98%.
3. 

Aerosol (Cabinet Level) before May 30th,Aerosol (Pack&Cabinet Level) after May 
30th.
4. 

Not all certifications & standards listed, check the official website for detail.
5. 

9.3 Smart Meter Technical Data

9.3.1 GM330

technical parameter
GM330

Supported Grid Type
Three-phase, split-phase, 
single-phase
voltage Range L-L (Vac)
172~817
voltage Range L-N (Vac)
100~472
Nominal Frequency (Hz)
50/60

Measurement 
Range

CT ratio
nA:5A

Communication Method
RS485
Communication 
Parameters
Communication Distance 
(m/ft)
1000/3280

voltage/current
Class 0.5
Active Energy
Class 0.5
Accuracy 
Parameters
Reactive Energy
Class 1

307

GW112.6-BAT-
AC-G10

Sayfa 309

technical parameter
GM330
Dimensions(WxHxDmm/in)
72x85x72/2.83x3.35×2.83

General 
Parameters

Housing
4-module

Weight (g/Ib)
240/0.53
Mounting Method
DIN rail

User Interface
4 LEDs, Reset Button

Power Consumption (W)
≤5

IP Rating
IP20
Operating Temperature 
Range (℃/°F)
-30~+70/-22~+158

Storage Temperature 
Range(℃/°F)
-30~70/-22~+158

Environmental 
Parameters

Relative Humidity (non-
condensing)
0~95%

Max. Operating Altitude 
(m/ft)
3000/9842

Certification 
Parameters
Certification
UL1741/ANSI

9.3.2 GM3000

Technical Parameter
GM3000

Application
Three-phase

Voltage

Nominal Voltage
3L+N/400V

Voltage Range
100V~240V

Frequency
50Hz/60Hz

Rated Current
CT in: 120A/40mA;
Current

Current Range
0.48A~120A

Power Consumption
<3W

Data Detection
Voltage/Current/Active Power/Reactive Power/Power 

Energy Calculation
Active/Reactive Power

Voltage/Current
Class I
Accuracy

Factor/Frequency

308

Sayfa 310

Active
Class I

Reactive
Class II

Communication
RS485 (Max. Speed 9600/ModBus Protocol/Max. Cable 

Display
LED, USB, Reset Button

Device

Dimensions (L x W x H 

mm)

Weight (g)
450

Ingress Protection 

Rating

Mounting Method
Back Plate Mounting

Operating Temperature
-25 ~ +60° C

Storage Temperature
-25 ~ +60° C

Humidity
<95%  Non-condensing

Operating Altitude(m)
< 2000m

Safe Service Life (Years)
≥25

9.3.3 GMK330

model
GMK330

Measurement Range

Supported Grid Type
1P2W/3P3W/3P4W

Operating voltage (Vac)*
3P4W:90~264 L-N
3P3W:90~264 L-L

Frequency (Hz)
50/60

CT ratio
120A: 40mA
200A: 50mA*

Number of CTs
3

Accuracy Parameters

voltage/current
Class 0.5

Active Energy
Class 0.5

Length 100m)

36 x 85 x 66.5

IP20(Indoor)

309

Sayfa 311

model
GMK330

Reactive Energy
Class 1

Communication Parameters

Communication Method
RS485

Communication Distance 
(m)
1000

General Parameters

Dimensions (W*H*D mm)
72*85*72

Housing
4模

Weight (g)
240

Mounting Method
DIN Rail

User Interface
4 LEDs, Reset Button

Power Consumption (W)
<5

Environmental Parameters

IP Rating
IP20

Operating Temperature 
Range (℃)
-30-+70

Storage Temperature Range 
(℃)
-30-+70

Relative Humidity (non-
condensing)
0-95%

Max. Operating Altitude (m)
3000

*Supports 1.1 times rated voltage input.
*The standard CT for the meter has been uniformly updated to the 120A:40mA 
specification. Meters equipped with the 200A:50mA CT will no longer be sold after 
June 2026.

310

Sayfa 312

9.4 Smart Dongle Technical Data

9.4.1 4G Kit-CN-G21

Product Model
4G Kit-CN-G21
Device Management
Max. Supported 
Inverter Quantity
1

Electrical Specifications
Input Voltage (V)
5
Power Consumption 
(W)
≤4

Interface Type
USB
Communication Specifications

4G/3G/2G
LTE-FDD:B1/B3/B5/B8
LTE-TDD:B34/B39/B40/B41
GNSS Positioning
BeiDou, GPS

Bluetooth
Bluetooth V5.0
Mechanical Specifications
Dimensions (W×H×D 
mm)
48.3*95.5*32.1

Weight (g)
87

indicator
LED* 2

Mounting Method
Plug and Play

SIM Card Size
Micro sim, 15mm*12mm
Environmental Specifications
Operating Temperature 
Range (℃)
-30~+65

Storage Temperature 
Range (℃)
-40~+70

Relative Humidity
0-100%

IP Rating
IP66
Max. Operating Altitude 
(m)
4000

311

Sayfa 313

Product Model
4G Kit-CN-G21

Compliance Standards

Certification
SRRC、CTA

9.4.2 4G Kit-CN-G20

Product Model
4G Kit-CN-G20
Device Management
Max. Supported 
Inverter Quantity
1

Power Parameters
Input Voltage (V)
5
Power Consumption 
(W)
≤4

Interface Method
USB
Communication Parameters

4G/3G/2G
LTE-FDD:B1/B3/B5/B8
LTE-TDD:B34/B39/B40/B41
GNSS Positioning
/

Bluetooth
Bluetooth V5.0
Mechanical Parameters
Dimensions 
(Width×Height×Thick
ness mm)

Weight (g)
87

indicator
LED* 2

Mounting Method
Plug and Play

SIM Card Size
Micro sim, 15mm*12mm
Environmental Parameters
Operating 
Temperature Range 
(℃)

Storage 
Temperature Range 
(℃)

Relative Humidity
0-100%

48.3*95.5*32.1

-30~+65

-40~+70

312

Sayfa 314

Product Model
4G Kit-CN-G20

IP Rating
IP66
Max. Operating 
Altitude (m)
4000

Compliant Standards

Certification
SRRC, CTA

9.4.3 WiFi/LAN Kit-20

technical parameter
WiFi/LAN Kit-20
Output Voltage (V)
5
Power Consumption (W)
≤2
Communication Interface
USB
Ethernet
10M/100Mbps Auto-negotiation
Wireless
IEEE 802.11 b/g/n @2.4 GHz
Communication 
Parameters
Bluetooth
Bluetooth V4.2 BR/EDR and Bluetooth 
LE Standard
Dimensions (W×H×D 
mm)
48.3*159.5*32.1

Mechanical 
Parameters

Weight (g)
82
Ingress Protection 
Rating
IP65

Mounting Method
USB Port Plug/Unplug
Operating Temperature Range (℃)
-30~+60
Storage Temperature Range (℃)
-40~+70
Relative Humidity
0-95%
Max. Operating Altitude (m)
4000

9.4.4 Ezlink3000

Indicator
/Silkscre
en

Color
Status
Description

Flashing = The communication stick is operating 
normally.
 
Blue

313

Sayfa 315

Indicator
/Silkscre
en

Color
Status
Description

Power 
Light

Communi
cation 
Light
Green

RELOAD
-
-

Off = The communication stick is powered off.

Steady on = The communication stick is 
connected to the server.
Double flash = The communication stick is not 
connected to the router.

Quadruple flash = The communication stick is 
connected to the router but not connected to 
the server.

Press and hold for 1-3 seconds to restart the 
communication stick.
•

Press and hold for 6-10 seconds to restore 
factory settings.
•

Double-click quickly to enable Bluetooth signal 
(only maintained for 5 minutes).

314

Sayfa 316

10 Appendix

10.1 FAQ

10.1.1 How to conduct auxiliary detection for smart meters/CT?

The meter detection function can check whether the meter CT is connected correctly 
and the current operating status of the meter and CT.

Method 1:
•

Go to [Home] > [Settings] > [Meter/CT Auxiliary Detection] to access the 
detection page.
1. 

Click Start Detection, wait for the detection to complete, and then view the results.
2. 

Method 2:
•

Click 
 > [System Setup] > [Quick Setting] > [Meter/CT Assisted Test] to access 
the detection page.
1. 

Click Start Detection, wait for the detection to complete, and then view the results.
2. 

10.1.2 How to Upgrade the Device Version

Through the firmware information, you can view or upgrade:
The inverter's DSP version, ARM version, communication module software version, 
battery's BMS version, DCDC version, etc.

Prompted Upgrade:
•

When the user opens the App, an upgrade prompt pops up on the home page. The 
user can choose whether to upgrade. If they choose to upgrade, they can complete 
the upgrade by following the on-screen instructions.

Regular Upgrade:
•

Go to [Home] > [Settings] > [Firmware Information] to enter the firmware 
information viewing interface.
Click "Check for Updates". If a new version is available, complete the upgrade by 

315

Sayfa 317

following the on-screen instructions.

Forced Upgrade:
•

The App pushes an upgrade notification. The user must upgrade as prompted; 
otherwise, the App cannot be used. Complete the upgrade by following the on-
screen instructions.
 
Inverter Software Version Upgrade

The inverter supports software upgrade via a USB drive.
•

Before using a USB drive to upgrade the device, please contact the after-sales 
service center to obtain the software upgrade package and upgrade method.
•

10.2 Abbreviations

Abbreviation
English Description
Chinese Description
Ubatt
Battery Voltage Range
Battery voltage range
Ubatt,r
Nominal Battery Voltage
Nominal battery voltage

Ibatt,max (C/D)
Max. Charging Current 
Max. Discharging Current 

EC,R
Rated Energy 
Rated Energy
UDCmax
Max.Input Voltage 
Max. Input Voltage

UMPP
MPPT Operating Voltage 
Range 
MPPT Voltage Range

IDC,max
Max. Input Current per MPPT 
Max. Input Current per MPPT

ISC PV
Max. Short Circuit Current per 
MPPT

Max. Short Circuit Current per 
MPPT
PAC,r
Nominal Output Power
Nominal output power

Sr (to grid)
Nominal Apparent Power 
Output to Utility Grid 

Smax (to grid)
Max. Apparent Power Output 
to Utility Grid

Sr (from grid)
Nominal Apparent Power 
from Utility Grid

Smax (from grid)
Max. Apparent Power from 
Utility Grid 

Max. Apparent Power from 
Utility Grid
UAC,r
Nominal Output Voltage 
Nominal output voltage

Max. Charging/Discharging 
Current

Nominal Apparent Power 
Output to Utility Grid

Max. Apparent Power Output 
to Utility Grid

Nominal Apparent Power from 
Utility Grid

316

Sayfa 318

Abbreviation
English Description
Chinese Description
fAC,r
Nominal AC Grid Frequency 
Nominal AC Grid Frequency

IAC,max(to grid)
Max. AC Current Output to 
Utility Grid 

Max. AC Current Output to 
Utility Grid
IAC,max(from 
grid)

Max. AC Current From Utility 
Grid 
Max. Current from Grid

P.F.
Power Factor 
Power Factor

Sr  
Back-up Nominal apparent 
power

Max. Output Apparent Power 
(VA)
Max. Output Apparent Power 
without Grid 

Smax

IAC,max
Max. Output Current
Max. Current to Grid
UAC,r
Nominal Output Voltage 
Max. Output Voltage

fAC,r
Nominal Output Freqency
Nominal Output Voltage 
Frequency

Toperating
Operating Temperature 
Range 
Operating Temperature Range

IDC,max
Max. Input Current
Max. Input Current
UDC
Input Voltage
Input Voltage
UDC,r
DC Power Supply
DC Input

UAC
Power Supply/AC Power 
Supply
Input Voltage Range/AC Input

UAC,r
Power Supply/Input Voltage 
Range
Input Voltage Range/AC Input

Toperating
Operating Temperature 
Range 
Operating Temperature Range

Pmax
Max Output Power
Maximum Power
PRF
TX Power
Transmit Power
PD
Power Consumption
Power Consumption
PAC,r
Power Consumption
Power Consumption
F (Hz)
Frequency
Frequency

ISC PV
Max. Input Short Circuit 
Current

Udcmin-Udcmax
Range of input Operating 
Voltage
Operating Voltage range

UAC,rang(L-N)
Power Supply Input Voltage
Adapter Input Voltage Range

Off-grid Nominal Apparent 
Power

Max. Apparent Power to Grid

Max. Input Short Circuit 
Current

317

Sayfa 319

Abbreviation
English Description
Chinese Description
Usys,max
Max System Voltage
Max. System Voltage
Haltitude,max
Max. Operating Altitude
Max. Operating Altitude
PF
Power Factor
Power Factor

THDi
Total Harmonic Distortion of 
Current
Current Harmonic Distortion

THDv
Total Harmonic Distortion of 
Voltage
Voltage Harmonic Distortion

C&I
Commercial & Industrial
Commercial & Industrial

SEMS
Smart Energy Management 
System

MPPT
Maximum Power Point 
Tracking

PID
Potential-Induced 
Degradation
Potential-Induced Degradation

Voc
Open-Circuit Voltage 
open-circuit voltage
Anti PID
Anti-PID
Anti-PID
PID Recovery
PID Recovery
PID Recovery

PLC
Power-line Commucation
Power Line Carrier 
Communication

Modbus TCP/IP
Modbus Transmission Control 
/ Internet Protocol
Modbus over TCP/IP

Modbus RTU
Modbus Remote Terminal 
Unit
Modbus over Serial Link

SCR
Short-Circuit Ratio
Short-Circuit Ratio
UPS
Uninterruptable Power Supply
Uninterruptible Power Supply
ECO mode
Economical Mode 
Economic Mode
TOU
Time of Use
Time of Use
ESS
Energy Stroage System
energy storage system
PCS
Power Conversion System
Power Conversion System
RSD
Rapid shutdown
Rapid Shutdown
EPO
Emergency Power Off
Emergency Poweroff
SPD
Surge Protection Device
Surge Protection

zero injection/zero export
Power Limit / Export Power 
Limit 

ARC

DRED
Demand Response Enabling 
Device

Smart Energy Management 
System

Maximum Power Point 
Tracking

Power Limit

Demand Response Enabling 
Device

318

Sayfa 320

Abbreviation
English Description
Chinese Description
RCR
Ripple Control Receiver
-
AFCI
AFCI
AFCI DC Arc Fault Protection

GFCI
Ground Fault Circuit 
Interrupter
GFCI

RCMU
Residual Current Monitioring 
Unit

Residual Current Monitoring 
Unit
FRT
Fault Ride Through
Fault Ride Through
HVRT
High Voltage Ride Through
High Voltage Ride Through
LVRT
Low Voltage Ride Through
Low Voltage Ride Through
EMS
Energy Management System
Energy Management System
BMS
Battery Management System
Battery Management System
BMU
Battery Measure Unit
Battery Measurement Unit
BCU
Battery Control Unit
Battery Control Unit
SOC
State of Charge
State of Charge
SOH
State of Health
State of Health
SOE
State Of Energy
State Of Energy
SOP
State Of Power
State Of Power
SOF
State Of Function
State Of Function
SOS
State Of Safety
State Of Safety 
DOD
Depth of discharge
depth of discharge

10.3 Explanation of Terms

•

Explanation of Overvoltage Categories

Overvoltage Category I: Equipment connected to circuits with measures to limit 
transient overvoltages to a relatively low level.

○

Overvoltage Category II: Energy-consuming equipment supplied by fixed 
distribution installations. This category includes appliances, portable tools, and 
other household and similar loads. If special requirements for reliability and 
suitability are imposed on such equipment, Overvoltage Category III is adopted.

○

Overvoltage Category III: Equipment in fixed distribution installations where 
reliability and suitability must meet special requirements. This includes switching 
devices in fixed distribution installations and industrial equipment permanently 
connected to fixed distribution installations.

○

Overvoltage Category IV: Equipment used in the power supply of distribution 
installations, including measuring instruments and pre-overcurrent protection 
devices, etc.

○

319

Sayfa 321

Explanation of Damp Location Categories
•

Environmental 

Parameter
Level

 
3K3
4K2
4K4H
Temperature 
Range
0~+40℃
-33~+40℃
-33~+40℃

Humidity Range
5% to 85%
15% to 100%
4% to 100%

•

Explanation of Environmental Categories:

Outdoor Inverter: Ambient air temperature range from -25 to +60°C, suitable 
for environments with Pollution Degree 3;

○

Indoor Type II Inverter: Ambient air temperature range from -25 to +40°C, 
suitable for environments with Pollution Degree 3;

○

Indoor Type I Inverter: Ambient air temperature range from 0 to +40°C, 
suitable for environments with Pollution Degree 2;

○

•

Explanation of Pollution Degree Categories

Pollution Degree 1: No pollution or only dry, non-conductive pollution;
○

Pollution Degree 2: Generally only non-conductive pollution, but occasional 
temporary conductive pollution due to condensation must be considered;

○

Pollution Degree 3: Conductive pollution exists, or non-conductive pollution 
becomes conductive due to condensation;

○

Pollution Degree 4: Persistent conductive pollution, such as pollution caused by 
conductive dust or rain/snow.

○

10.4 Meaning of Battery SN Code

Digits 11-14 of the product SN code represent the production date code. 
The production date in the image above is 2023-08-08.

320

Sayfa 322

Digits 11 and 12 represent the last two digits of the production year, e.g., 2023 is 
represented as 23;
•

Digit 13 represents the production month, e.g., August is represented as 8; 
Details are as follows:
•

Month
Jan-Sep
Oct
Nov
Dec

Month Code
1~9
A
B
C

•

Digit 14 represents the production day, e.g., the 8th is represented as 8; 
Numbers are used preferentially, e.g., 1~9 represent the 1st~9th day, A represents 
the 10th day, and so on. The letters I and O are not used to avoid confusion. Details 
are as follows:   

Production Day
1
2
3
4
5
6
7
8
9

Code
1
2
3
4
5
6
7
8
9

Production Date
10
11
12
13
14
15
16
17
18

Code
A
B
C
D
E
F
G
H
J

Production Date
21
22
23
24
25
26
27
28
29

Code
M
N
P
Q
R
S
T
U
V

10.5 Safety Compliance Countries

No.
Safety Regulation Name
No. Safety Regulation Name

Europe

1
IT-CEI 0-21 
56
IE-LV-72A

2
IT-CEI 0-16 
57
IE-ESB-C&D(<110kV)

3
DE LV with PV
58
IE-EirGrid-110kV

4
DE LV without PV
59
PT-D

5
DE-MV
60
EE

321

Sayfa 323

No.
Safety Regulation Name
No. Safety Regulation Name

6
ES-A
61
NO

7
ES-B
62
FI-A

8
ES-C
63
FI-B

9
ES-D
64
FI-C

10
ES-island
65
FI-D

11
BE
66
UA-A1

12
FR-LV
67
UA-A2

13
FR-island-50Hz 
68
EN 50549-1

14
FR-island-60Hz 
69
EN 50549-2

15
type A-PL_V.1.1
70
DK-West-B-MVHV

16
type B-LV-PL_V.1.1
71
DK-East-B-MVHV

17
type C-PL_V.1.1
72
DK-West-C-MVHV

18
type D-PL_V.1.1
73
DK-East-C-MVHV

19
NL-16/20A 
74
DK-West-D-MVHV

20
NL-A
75
DK-East-D-MVHV

21
NL-B
76
FR-Reunion

22
NL-C
77
BE-LV(>30kVA)

23
NL-D
78
BE-HV

24
SE-A 
79
CH-B

25
SE MV 
80
NI-G99-A

26
SK-A
81
NI-G99-B

27
SK-B
82
NI-G99-C

28
SK-C
83
NI-G99-D

322

Sayfa 324

No.
Safety Regulation Name
No. Safety Regulation Name

29
HU
84
IE-LV-170kVA

30
CH-A
85
IE-MV&HV-200kVA

31
CY
86
DE-HV

32
GR
87
FR-MV

33
DK-West-A
88
CZ-A1/A2-09

34
DK-East-A
89
DE-EHV

35
DK-West-B
90
IE-EirGrid-400KV

36
DK-East-B
91
IE-EirGrid-220KV

37
AT<1kV
92
IE-EirGrid-66KV

38
AT>1kV
93
IE-ESB-B

39
BG
94
IE-ESB-D(≥110kV)

40
Czech
95
type B-MV-PL_V.1.1

41
CZ-A1-09
96
GB-G99-A HV

42
CZ-A2-09
97
GB-G99-B LV

43
CZ-B1/B2-09
98
GB-G99-C LV

44
CZ-C
99
UA-B

45
CZ-D
100
UA-C

46
RO-A
101
UA-D

47
RO-B
102
UK-G98

48
RO-D
103
UK-G99-A LV

49
GB-G98
104
UK-G99-B LV

50
GB-G99-A LV
105
UK-G99-C LV

51
GB-G99-B HV
106
CZ-A1

323

Sayfa 325

No.
Safety Regulation Name
No. Safety Regulation Name

52
GB-G99-C HV
107
UK-A-MV

53
GB-G99-D
108
UK-B-MV

54
NI-G98
109
UK-C-MV

55
IE-LV-16/25A
-
-

Global

1
60Hz-Default 
6
IEC 61727-60Hz 

2
50Hz-Default 
7
Warehouse 

3
127Vac-60Hz-Default 
8
IEC61727-480Vac-60Hz 

4
127Vac-50Hz-Default 
9
IEC61727-480Vac-50Hz

5
IEC 61727-50Hz

Americas

1
Argentina-220V-LV
38
LUMAPR-2024-220Vac-3P

2
US-208Vac 
39
LUMAPR-2024-240Vac-3P

3
US-240Vac 
40
Cayman

4
Mexico-220Vac
41
Brazil-220Vac

5
Mexico-440Vac
42
Brazil-208Vac

6
US-480Vac 
43
Brazil-230Vac

7
US-208Vac-3P
44
Brazil-240Vac

8
US-220Vac-3P
45
Brazil-254Vac

9
US-240Vac-3P
46
Brazil-127Vac 

10
US-CA-208Vac 
47
Brazil-ONS

11
US-CA-240Vac 
48
Barbados 

12
US-CA-480Vac 
49
Chile-BT 

13
US-CA-208Vac-3P
50
Chile-MT-A

324

Sayfa 326

No.
Safety Regulation Name
No. Safety Regulation Name

14
US-CA-220Vac-3P
51
Chile MT-B

15
US-CA-240Vac-3P
52
Colombia

16
US-HI-208Vac
53
Colombia<0.25MW-208Vac-1P

17
US-HI-240Vac
54
Colombia<0.25MW-120Vac-3P

18
US-HI-480Vac
55
IEEE 1547-208Vac 

19
US-HI-208Vac-3P
56
IEEE 1547-220Vac

20
US-HI-220Vac-3P
57
IEEE 1547-240Vac 

21
US-HI-240Vac-3P
58
IEEE 1547-230Vac

22
US-Kauai-208Vac
59
Colombia<0.25MW-127Vac-3P

23
US-Kauai-240Vac
60
Colombia>5MW

24
US-Kauai-480Vac
61
Mexico-127V

25
US-Kauai-208Vac-3P
62
Mexico-240V

26
US-Kauai-220Vac-3P
63
US-O&R-208Vac

27
US-Kauai-240Vac-3P
64
US-O&R-240Vac

28
US-ISO-NE-208Vac
65
US-O&R-480Vac

29
US-ISO-NE-240Vac
66
US-O&R-208Vac-3P

30
US-ISO-NE-480Vac
67
US-O&R-220Vac-3P

31
US-ISO-NE-208Vac-3P
68
US-O&R-240Vac-3P

32
US-ISO-NE-220Vac-3P
69
Brazil-277Vac

33
US-ISO-NE-240Vac-3P
70
Chile-BT ≤9MW

34
LUMAPR-2024-208Vac
71
Chile-MT ≤9MW

35
LUMAPR-2024-240Vac
72
Chile>9MW

36
LUMAPR-2024-480Vac
73
Mexico-277Vac

325

Sayfa 327

No.
Safety Regulation Name
No. Safety Regulation Name

37
LUMAPR-2024-208Vac-3P

Oceania

1
Australia-A
4
Newzealand

2
Australia-B
5
Newzealand:2015

3
Australia-C
6
NZ-GreenGrid

Asia

1
China A
33
Israel-MV

2
China B
34
Israel-HV

3
China Higher Voltage
35
Vietnam

4
China Highest Voltage
36
Malaysia-LV

5
China Power Station
37
Malaysia-MV

6
China Shandong
38
DEWA-LV 

7
China Hebei
39
DEWA-MV 

8
China PCS
40
Saudi Arabia-220V-LV

9
Taiwan
41
JP-690Vac-50Hz 

10
Hong Kong
42
JP-690Vac-60Hz

11
China Northeast
43
Srilanka-MV/HV

12
Thailand-MEA
44
IEC 61727-127Vac-50Hz

13
Thailand-PEA
45
IEC 61727-127Vac-60Hz 

14
Mauritius 
46
JP-550Vac-50Hz

15
Korea 
47
JP-550Vac-60Hz

16
India 
48
India-Higher

17
India-CEA 
49
JP-220Vac-50Hz

18
Pakistan
50
JP-220Vac-60Hz

326

Sayfa 328

No.
Safety Regulation Name
No. Safety Regulation Name

19
Philippines 
51
Saudi Arabia-127V-LV

20
Philippines-127Vac
52
Srilanka-LV >1MW

21
JP-200Vac-50Hz
53
China-YN

22
JP-200Vac-60Hz
54
GB/T 29319-LV

23
JP-440Vac-50Hz 
55
GB/T 29319-MV

24
JP-440Vac-60Hz
56
Philippines-277Vac

25
JP-420Vac-50Hz
57
JP-360Vac-50Hz

26
JP-420Vac-60Hz
58
JP-360Vac-60Hz

27
JP-480Vac-50Hz
59
JP-320Vac-50Hz

28
JP-480Vac-60Hz
60
JP-320Vac-60Hz

29
Srilanka-LV<1MW
61
JP-340Vac-50Hz

30
Singapore
62
JP-340Vac-60Hz

31
Israel-OG
63
JP-380Vac-50Hz 

32
Israel-LV
64
JP-380Vac-60Hz

Africa

1
Mauritius    
5
Ghana-LV

2
South Africa-LV
6
Ghana-HV

3
South Africa-B-MV
7
South Africa-A3-LV

4
South Africa-C-MV
8
Nigeria

327

Sayfa 329

11 Contact Details

 
 
 
 
 
 
 
 
GoodWe Technologies Co., Ltd. 
No. 90 Zijin Rd., New District, Suzhou, China 
en.goodwe.com 
service@goodwe.com

328