Owner's Manual Original Instructions Wired Controller XE7C-24/HC Wired Controller XE7C-24/H GREE+
To Users Thank you for selecting Gree product. Please read this instruction manual carefully before installing and using the product, so as to master and correctly use the product. In order to guide you to correctly install and use our product and achieve expected operating effect, we hereby instruct as below: (1) This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsibility for their safety. Children should be supervised to ensure that they do not play with the appliance. (2) This instruction manual is a universal manual; some functions are only applicable to particular product. All the illustrations and information in the instruction manual are only for reference, and control interface should be subject to actual operation. (3) In order to make the product better, we will continuously conduct improvement and innovation. If there is adjustment in the product, please subject to actual product. (4) If the product needs to be installed, moved or maintained, please contact our designated dealer or local service center for professional support. Users should not disassemble or maintain the unit by themselves, otherwise it may cause relative damage, and our company will bear no responsibilities.
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
1 Safety Notices (Please be sure to abide them) ....... 1 2 Operation Notices...................................................... 1 3 Display ........................................................................ 3 3.1 LCD of Wired Controller ....................................... 4 3.2 LCD Display Instruction ........................................ 4 3.3 Instruction of Status Column Icons ....................... 5 4 Button ......................................................................... 7 4.1 Button Silk Screen ................................................ 7 4.2 Buttons Function Instruction ................................. 8 5 Installation and Commissioning .............................. 9 5.1 Instruction of Wired Controller ............................ 10 5.2 Engineering Debugging ...................................... 16 6 Operation Instruction .............................................. 30 Contents
6.1 ON/OFF .............................................................. 30 6.2 Mode Setting ...................................................... 31 6.3 Temperature Setting ........................................... 32 6.4 Fan Setting ......................................................... 34 6.5 Swing Setting ..................................................... 35 6.6 Function Setting ................................................. 36 6.7 Universal Setting ................................................ 54 6.8 Timer Setting ...................................................... 58 7 Error Display ............................................................ 64 7.1 Table of Error Codes for VRF and Big Duct Unit 65 7.2 Table of Display Codes for U-Match Unit ............ 76
Owner’s Manual 1 Safety Notices (Please be sure to abide them) WARNING: If not abide them strictly, it may cause severe damage to the unit or the people. NOTE: If not abide them strictly, it may cause slight or medium damage to the unit or the people. This sign indicates that the items must be prohibited. Improper operation may cause severe damage or death to people. This sign indicates that the items must be observed. Improper operation may cause damage to people or property. WARNING! This product can’t be installed at corrosive, inflammable or explosive environment or the place with special requirements, such as kitchen. Otherwise, it will affect the normal operation or shorten the service life of the unit, or even cause fire hazard or serious injury. As for the above special places, please adopt special air conditioner with anti-corrosive or anti-explosion function. 2 Operation Notices The power supply for all indoor units must be unified. Prohibit installing the wired controller at wet or sunshine places. Do not knock, throw or frequently disassemble the wired controller. Do not operate the wired controller with wet hands. This product is applicable to VRF unit, Big Duct Type unit, Air- cooled Packaged unit and U-Match unit whose outdoor unit and indoor unit communicate with each other by live line and neutral line. 1
When two wired controllers control one (or more) indoor unit(s), the address of wired controller should be different. Functions with “*” are optional for indoor units. If a function is not included in an indoor unit, wired controller can’t set the function, or setting of this function is invalid to the indoor unit. Please pay attention to below items when matching with VRF unit: When the system mode priority is the master-slave mode, in one system network, you must set one indoor unit as the master indoor unit, other indoor units are slave indoor units. When the system mode priority is the master-slave mode, the operation mode of the system is basing on that of the master indoor unit. The master indoor unit can be set to any mode (including auto mode), while the slave indoor unit can’t set to the mode that conflicts with the system mode. When the system mode priority is: Cooling mode is prioritized, heating mode is prioritized, first-set mode is prioritized, or last-set mode is prioritized. The indoor unit can be set to any mode (excluding auto mode). The indoor unit will automatically switch to the system mode, when the operation mode of the indoor unit conflicts with the system operation mode. When the system mode priority is the voting mode (indoor unit’s capacity is prioritized / number of indoor units is prioritized). The indoor unit can be set to any mode (excluding the auto mode). The indoor unit will be stopped, when the operation mode of the indoor unit conflicts with the Owner’s Manual 2
Owner’s Manual system operation mode after voting. System mode priority defaults to master-slave mode, and only certain units have other system mode priorities. Hereby, Our company, declares that this product is in compliance with the essential requirement and other relevant provisions of RE Directive 2014/53/EU. Wireless frequency range: 2412MHz - 2472MHz. Maximum Transmit Power: 18dBm. 3 Display Fig. 3.1 Appearance of wired controller 3
3.1 LCD of Wired Controller Fig. 3.2 LCD graphics of wired controller 3.2 LCD Display Instruction Table 3.1 LCD display instruction No. Name Instruction 1 Status column Display the icon of function that is turned on 2 Fan speed It is for displaying the fan speed 3 Swing It is for displaying the current swing status 4 Button prompt Display the function of menu/ok button at the current page and the settable cursor It shows the value of temperature (If the wired 5 Temperature controller is controlling a fresh air indoor unit, display it will display FAP). 6 Mode It shows the operating mode 4 Owner’s Manual
Owner’s Manual No. Name Instruction 7 Clock display No. of current indoor unit. NOTE: When wired controller is connected with different indoor units, some functions will be different. 3.3 Instruction of Status Column Icons Table 3.2 Instruction of Status Column Icon No. Symbols Name Instructions 1 Air * Air status(indoor unit optional 2 Remove card The card for access control is 3 Clean Remind to clean the filter 4 Child lock Child lock status 5 Error There are errors for the unit 6 Health * Health function (indoor unit optional 7 Defrosting Defrosting status of outdoor unit 8 Master Current wired controller connects the 9 Power off It display the date and the time. When it’s locating the indoor unit, it displays the project function) removed function) master indoor unit. Memory status (when power recovered, indoor unit will resume memory previous setting status) 5
No. Symbols Name Instructions 10 Absence Absence is displayed when this 11 12 Energy- 13 Shield Shielding status 14 Slave wired 15 Sleep Sleep status 16 Time Timer status is displayed 17 X-fan X-fan is displayed when this function 18 Group control One wired controller controls multiple 19 Valid operation It’s displayed for valid operation 20 WiFi 21 Independent Owner’s Manual function is turned on. Quiet status Quiet status (including quiet and auto quiet modes) saving Energy-saving status of indoor unit Slave wired controller (address of controller wired controller is 02). is set. indoor units. WiFi status(If the wired controller has no WiFi function, it displays only when the unit connected to “G-Cloud”). swing* Independent swing status 6
Owner’s Manual No. Symbols Name Instructions 22 Auto clean * Auto clean status 23 I-DEMAND* I-DEMAND function, Indoor unit 24 DRED* DRED gear control status 25 Setback Setback function status NOTE: When wired controller is connected with different indoor units, some functions will be different. 4 Button 4.1 Button Silk Screen Fig. 4.1 Button silk screen optional function. 7
4.2 Buttons Function Instruction Table 4.1 Buttons function instruction No. Name Function 1 Fan Switch fan speeds: auto, low, medium-low, medium, Medium-high and high 2 (1) Set operation temperature for the indoor unit. (2) Move cursor. (3) Set and check parameters. 7 3 On/off button for turn on or turn off the unit; back button for return to previous page. 9 (1) Turn pages, and switch and select the target; (2) Move the cursor; (3) Set and check parameters. 4 5 Mode Switch operating modes: Auto, Cool, Dry, Fan, Heat, Floor, 3D Heat, etc. 6 Menu/OK Select mode and confirm parameters. 8 Swing Set the swing status of central air conditioners. Owner’s Manual 8
Owner’s Manual 5 Installation and Commissioning Unit: mm Fig. 5.1 Dimension of Wired Controller Fig. 5.2 Parts and Components of Wired Controller 9
No. 1 2 3 4 Panel of Self-tapping screw of wired controller QTY 1 4 2 1 5.1 Instruction of Wired Controller 5.1.1 Requirements for Model Selection of Communication Wire Name wired controller ST3.9×25 MA Fig. 5.3 Length of communication wire 10 Owner’s Manual Soleplate Screw M4×25
Owner’s Manual Wire material Total length L (m/feet) Wire size Material standard Remarks (mm2/AW type G) (1) Total length of communication line can't exceed 250m (820- 1/5feet). (2) The cord shall be Light/ Ordinary Polyvinyl 2×0.75 mm2~2× 1.25 mm2 (2×AWG chloride sheathed L≤250m (L≤820- circular cord (the cores shall be twisted together). (3) If unit is installed in IEC 60227- 5:2007 cord. (60227 IEC 52 /60227 IEC 53) 1/5 feet) 18~ 2×AWG1 6) places with intense magnetic field or strong interference, it is necessary to use shielded wire. 5.1.2 Requirements for Installation (1) It is not allowed to install the wired controller in the wet place. (2) It is not allowed to install the wired controller in the place with direct sunlight. (3) It is not allowed to install the wired controller near the high- temperature object or the place is likely to be spattered with water. 11
5.1.3 Requirements for Wired Connection Network connecting methods between wired controller and indoor unit are as below: Fig. 5.4 One wired controller controls one indoor unit Owner’s Manual 12
Owner’s Manual Fig. 5.5 One wired controller controls multiple VRF indoor units simultaneously Fig. 5.6 One wired controller controls multiple U-Match simultaneously 13
Instruction for wire connection: (1) The wiring methods in fig. 5.4 and fig. 5.6 can be adopted for the wired controller connecting U-Match unit. (2) The wiring methods in fig. 5.4 and fig. 5.5 can be adopted for the wired controller connecting VRF unit. (3) Only the wiring methods in fig. 5.4 can be adopted for the wired controller connecting Big Duct Type unit or Air-cooled Packaged unit, that is, one wired controller can control only one indoor unit, cannot control multiple indoor units of different systems. (4) When one wired controller controls multiple indoor units simultaneously, the wired controller can connect to any one indoor unit, but the connected indoor unit must be the same series indoor unit. The total quantity of indoor unit controlled by wired controller can't exceed 16 sets, and the connected indoor unit must be within the same indoor unit's network. Wire controller must set quantity of group control indoor units. Please refer to 5.2.2 Parameter Setting. (5) The terminal of the wire controller is non-polarized and cannot be connected to strong electric. NOTE: Wired controller XE7C-24/HC only supports one (or more) indoor unit(s) controlled by one wired controller. Owner’s Manual 14
Owner’s Manual 5.1.4 Installation Fig. 5.7 Installation of Wired Controller 15
Fig. 5.7 shows a simple installation course of wired controller, and the following points should be noted: (1) Before installation, please cut off the power supply of indoor unit, it is not allowed to operate with power supply; (2) Pull out the 2-core twisted pair inside the installation hole in the wall, and thread the wire through the hole in the back of soleplate of wired controller; (3) Stick the soleplate of wired controller on the wall, and use Self- tapping Screw ST3.9×25 MA or screw M4×25 to fix the soleplate with the installation hole of wall; (4) Connect the 2-core twisted pair to wiring terminal H1 and H2, and then tighten the screw; (5) Arrange the wires in the back of panel, and then buckle the panel of wired controller with the soleplate of wired controller. 5.1.5 Disassembly Fig. 5.8 Disassembly of wired controller 5.2 Engineering Debugging 5.2.1 Parameter View Under on or off status, view unit’s parameters. Press “Menu/OK” button on the home page to enter into the menu page to select “View” to go to view page shown as below: Owner’s Manual 16
Owner’s Manual (1) View and locate indoor unit project No. Select “IDU Project No. View and Locating” on the view page to go to indoor unit project No. view and locating page shown as below. Indoor unit project No. and error codes will be displayed on this page. If there are multiple indoor units, press “◀” or “▶” button to switch the indoor unit. Corresponding indoor unit project No. and current errors will be displayed. When one indoor unit has multiple errors, the error codes will be displayed circularly at the interval of 3s. If there is no error, “none” will be displayed. 17
After entering indoor unit project No. View and locating page, the buzzer of selected indoor unit gives out sound until exit from the view page or switch to the next indoor unit. (2) One button to view all indoor units’ project No. (only for VRF unit) Select “View All IDU Project No.” on the view page, move the cursor left and right to turn on or turn off this function. Press “Menu/OK” button to confirm it. After turning on “View All IDU Project No.” function, all indoor units and wired controllers (the wired controller displays indoor units’ project No. every 3s in turn, and the project No. are displayed from smallest to biggest) in the internet display their project series No. After turning on “View All IDU Project No.” function, this function can be selected on the view page. Move the cursor to select “off” status, press “Menu/OK” button to turn off this function or press “ ” on the connected wired controller to cancel the display of all indoor units’ project series No. Owner’s Manual 18
Owner’s Manual (3) Parameter View Select “parameter view” at the view page to enter into paremeter view page shown as below. As for the parameters, please refer to table 5.1 “Unit parameters view list”. When viewing the indoor unit, if there are multiple indoor unit, press “◀” or “▶” button to switch indoor units. Corresponding indoor unit’s parameters will be displayed on the page. See the figure as below: When viewing the outdoor unit, if there are multiple outdoor unit, 19
press “◀” or “▶” button to switch outdoor units. Corresponding outdoor unit’s parameters will be displayed on the page. See the figure as below: Table 5.1 Unit parameters view list Parameter Name Range Parameter Wired Controller’s Address Master IDU’s Project No. 0,1~255 Time Left to Clean Filter 0~416 days Online IDUs of CAN1 1~100 CAN2 address 1~255 Max Distribution Ratio IDU Error Log 5 historical errors Prior Operation Yes, No Owner’s Manual Name Range 1,2 Number of IDUs 1~16 110% 135% 150% Cool Only, Heat Cool & Heat Only, Cool & Modes Heat, Fan 20
Owner’s Manual Parameter Name Range Parameter Name Range Indoor Temp -30°C -139°C Relative Humidity / RH 0%~100% Inlet Temp 1 -30°C -139°C Outlet Temp 1 -30°C -139°C Inlet Temp 2* -30°C -139°C Outlet Temp 2* -30°C -139°C IDU capacity and capacity after adjustment IDU Capacity IDU EXV Status 0~20 Fresh Air IDU Output Temp* -30°C -139°C ODU Static Pressure 0~4 Duct Network Static Pressure 0~999 ODU Error Log 5 historical errors The following parameters can only be viewed from the master wired controller, they cannot be viewed from the slave wired controller Parameter Name Range Parameter Name Range Unit Code 0~9, A~Z, a~z, - Board Code 0~9, A~Z, a~z,- Outdoor Temp -30~139°C Comp1 Operation Freq. 0~200Hz Comp 2 Operation Freq. 0~200Hz ODU Fan Operation Freq. 0~100Hz Module High Pressure -40~70°C Module Low Pressure -69~38°C Comp 2 Discharge Comp1 Discharge Temp -30~150°C Temp. 21 -30~150°C
The following parameters can only be viewed from the master wired controller, they cannot be viewed from the slave wired controller Parameter Name Range Parameter Comp 3 Discharge Temp -30~150°C Comp 5 Discharge Temp -30~150°C Comp 3 Operation Freq. 0~200Hz ODU Heating ODU Heating EXV2 0~48 Subcooler EXV 0~48 Defrosting Temp -30~139°C Subcooler Liquid Temp -30~139°C Separator Outlet Temp -30~139°C Oil Return Temp -30~139°C Condenser Inlet Temp -30~139°C Condenser Outlet Temp -30~139°C NOTES: ① Under parameter viewing status, the signal from remote controller is invalid. ② When the parameter is invalid, it will display “--”. 5.2.2 Parameters Setting Parameters can be set under on or off status. Press “Menu/ok” button on the homepage to enter into menu page to select “set” to go to set page. Select “parameter setting” at Owner’s Manual Name Range Comp 4 Discharge -30~150°C Temp. Comp 6 Discharge -30~150°C Temp. EXV1 0~48 22
Owner’s Manual the set page to go into parameter setting page. See the figure as below. Select user parameter, project parameter and U-Match parameter to enter into corresponding parameter setting. See the figure as below: After that, press “▲” or “▼” button to switch the items. Hold it can switch it quickly. When selecting the parameter, press “◀” or “▶” to switch the setting value. Press “menu/ok” button to save corresponding setting 23
items. If the setting can’t be confirmed, switching the item can restore the previous setting value. Please refer to table 5.2 for the settable parameters. Table 5.2 Unit’s parameters setting list Item Settable range Default Remarks Master Wired Controller Yes, No Yes Owner’s Manual When it is set as no, this wired controller is slave wired controller. Status column of the homepage displays the icon of slave wired controller “ ” . The wired controller can only activate the master wired controller. It does not have the function of setting parameters for other units. 24
Owner’s Manual Item Settable range Default Remarks Master IDU Yes, No No Use Remote Yes, No Yes Prior Operation Yes, No No High Ceiling Installation* Yes, No No Only applicable to cassette type IDU Once it is activated, the current IDU is set to be the master IDU. When the setting is Yes, if the system mode priority is the master-slave mode, the status column in homepage will display the icon of master IDU “ ”; when the setting is off, master and slave status of the current IDU will not be changed. When it is set as no, the wired controller cannot receive the remote control signal. It can only be operated with buttons. When the power supply is insufficient, it is allowed to turn on the designated IDU as preferential operation; other IDUs should be forced to be off. 25
Item Settable range Default Remarks Link with Fresh Air Yes, No No IDU* PM2.5 Filter* Yes, No No Yes: Temp and humidity correction Temp and RH Correction control No: Ambient temperature Control control Owner’s Manual After setting the linkage function, the fresh air IDU will automatically turn on or turn off along with the on and off of general IDU. Meanwhile, users can manually turn on or turn off the unit. It only applicable to fresh air IDU. After it is successfully set, adjust the revolving speed to ensure the air volume is close to or the same as the previous air volume. It is only applicable to the unit with PM2.5 filter. Refer to indoor unit for It can be set only when it’s supported by the indoor unit. the defaulted value 26
Owner’s Manual Item Settable range Default Remarks Yes: Humidity Dry Mode control No: Temperature Humidity Control control Clear Filter Cleaning Yes, No No — Time Indoor Fan Static Pressure 1~9 5 0: This function is unavailable 1-16: quantity of IDU Number of IDUs Angle of Air-return Angle 1 Angle 2 Angle 3 Board* Cooling temp of Auto Mode 25°C (77°F) Cooling temperature of auto mode – heating temperature of auto mode≥1°C. Heating temp of Auto Mode 17°C~30°C (63°F~86°F) 16°C ~29°C (61°F~84°F) If select “yes”, set humidity is displayed under dry mode. Otherwise, set temperature is displayed. It can only be set when it’s supported by the indoor unit. No 1 Set corresponding value according to the connected quantity of IDU. Angle 2 Only applicable to the model with air-return plate. 20°C (68°F) 27
Item Settable range Default Remarks Resume After Inserting Yes, No Yes Card Time for IDU Cold 180s, 300s, 420s, 600s 180s Air Prevention* Set Temp of RH Control 10°C ~30°C (50°F~86°F) Mode Owner’s Manual When it is set as No, it will keep the status after inserting the gate control card. If it is at OFF status when pulling out the card, when inserting the card, it is still at OFF status. Cold air prevention time is the max waiting time from the time turning on the heating mode to the time blowing out the hot wind. The actual waiting time is related to the outdoor ambient temperature. If there is cold air after turning on the heating mode in the actual operation, please consult the professional person to adjust this parameter. Note: It’s only applicable for the units whose dry mode is with humidity control function. 16°C (61°F) 28
Owner’s Manual Item Settable range Default Remarks 01: Normal 02: Quick 03: Deep 1 Auto Clean Mode Cooling Temp of Fresh Air 16°C ~30°C (61°F~86°F) IDU* Heating Temp of Fresh Air 16°C ~30°C (61°F~86°F) IDU* Setback Yes, No No -- Upper Temp Limit of Setback 20~30°C (68~86°F) Lower Temp Limit of Setback 16~26°C (61~79°F) Reset G- Cloud Yes, No No Only applicable to Wired Controller XE7C-24/HC. NOTE: Only applicable to the unit with auto clean function. If “0” is displayed, this function is not available for this unit. 18°C (64°F) Only applicable to fresh air IDU. 22°C (71°F) Only applicable to fresh air IDU. When temperature unit is °C, temperature upper limit – temperature lower limit ≥ 4°C; When temperature unit is °F, temperature upper limit – temperature lower limit ≥7°F. 26°C (79°F) 20°C (68°F) 29
Item Settable range Default Remarks No Occupancy Energy- -40~40 0 Only applicable after installing Smart Sensor. saving Time of I SENSE NOTES: ① Except for the above parameters, setting interface for other parameter can only be accessed by inputting password. ② Under parameter setting status, the signal from remote controller is invalid. ③ Under some circumstances, invalid parameters setting is in grey. Press “▲” or “▼”button to skip this parameter setting. 6 Operation Instruction 6.1 ON/OFF Press “ ” button to turn on the air conditioner. Press “ ” button again to stop operation. ON and OFF interfaces are shown as below: 30 Owner’s Manual
Owner’s Manual Fig. 6.1 ON interface Fig. 6.2 OFF interface 6.2 Mode Setting Under On status, pressing “MODE” button can set modes circularly: OR 31
NOTES: ① The available modes are different for different models. The wired controller will automatically select mode setting range according to the model of indoor unit. ② When the wired controller controls VRF unit and the system mode priority is the master-slave mode, only the master indoor unit can set the auto mode. ③ Under Auto mode, if the indoor unit is cooling, the icons “ ” and “ ” will light up; if the indoor unit is Heating, the icons “ ” and “ ” will light up. 6.3 Temperature Setting Press “▲” or “▼”button under on status to increase or decrease set temperature by 0.5°C/1°C or 1°F; hold “▲” or “▼”button to increase or decrease set temperature by 0.5°C/1°C or 1°F every 0.3s. Please refer to 6.7.4 for the setting method of the temperature setting interval in Celsius. Under Dry mode, when temperature is 16°C or 61°F, continuously press “▼”button twice to decrease temperature to 12°C or 54°F (when save function is activated, the temperature under Dry mode can’t be adjusted to 12°C or 54°F). When the control method under Dry mode is humidity control, press “▲” or “▼”button to adjust the set humidity at 5% intervals. The humidity setting range is 45%~75%, and the default value is 65%. The humidity control method under Dry mode can only be set for the Owner’s Manual 32
Owner’s Manual unit with this function. Please refer to 5.2.2 Parameter Setting for the setting method. NOTES: ① Only when the wired controller controls U-Match indoor units, the setting temperature can be adjusted by pressing “▲” or “▼” under Auto mode. ② When Absence function is activated, the setting temperature cannot be adjusted by pressing “▲” or “▼”. ③ When the wired controller is connected with a Fresh Air Indoor Unit, fresh air indoor unit code “FAP” will be displayed as shown below. Setting temperature won’t be displayed and can’t be adjusted via “▲” or “▼”button. The air outlet temperature in cooling or heating can only be set in the parameter setting status. 33
6.4 Fan Setting Under On status, pressing “FAN” button can set fan speeds circularly as: NOTES: ① Under Dry mode, fan speed is low and can’t be adjusted. ② When the wired controller is connected with a Fresh Air Indoor Owner’s Manual 34
Owner’s Manual Unit, fan speed of indoor unit will be high fan speed only. Fan speed of indoor unit can’t be adjusted via “FAN” button. ③ If indoor unit’s fan speed is set auto, indoor unit will change fan speed automatically according to room temperature in order to make the room temperature more stable and comfortable. 6.5 Swing Setting (1) Up&down Swing : The up&down swing has two modes: simple swing and fixed- angle swing. Select the fixed-angle swing on the function page, and press “◀” and “▶” buttons to turn on or turn off the fixed-angle swing. Simple swing and fixed-angle swing can be switched. Under on status, press “Swing” button on the homepage to enter into swing setting: 1)When the simple swing is set, press “Swing” button to turn on or turn off the up&down swing. 2)When the fixed-angle swing is set, press “Swing” button to switch swing statuses circularly as below: (2) Left&right swing*: The left&right swing has two modes: simple swing and fixed- angle swing. Select the fixed-angle swing on the function page, and press “◀” and “▶” buttons to turn on or turn off the fixed-angle swing. Simple swing and fixed-angle swing can be switched. Under on status, press “Swing” button on the homepage to enter 35
into swing setting, and then press “◀” and “▶” button to switch to the left&right swing setting: 1)When the simple swing is set, press “Swing” button to turn on or turn off the left&right swing. 2)When the fixed-angle swing is set, press “Swing” button to switch swing statuses circularly as below: 6.6 Function Setting Press “Menu/OK” button on the homepage to enter menu page and then select “Function” to go to function page. See the figure as below. Fig. 6.3 Function page Press “▲” or “▼”button to switch the items; press “◀” and “▶” button to turn on or turn off corresponding function. “ON” indicates the function is turned on; “OFF” indicates the function turned off; press “Back” button to turn back to previous page. Owner’s Manual 36
Owner’s Manual Some functions are with more parameters and “Menu/OK” button can be used for setting detailed parameters. Fig. 6.4 Function with detailed setting As for some functions, only the on/off status is displayed at the switch button. It needs to press “Menu/OK” button to enter into detailed setting: Fig. 6.5 Functions whose on/off status is only displayed NOTES: The function under some circumstances is invalid and displayed in grey. Press “▲” or “▼”button to skip this function. 37
6.6.1 Turbo Setting Turbo fan Function: Turn on the highest fan speed, and then turbo fan will be displayed on the homepage. Turn on turbo fan Function: Under on status, select turbo fan on the function page and press “◀” or “▶” button to turn on or turn off the turbo fan. When turbo fan is turned on, “turbo fan” will be displayed at the fan speed area on the homepage. Cancel turbo fan Function: Same as the method used for turning on the turbo Fan Function. You can also press “Fan” button on the home page to cancel the turbo fan and then switch to the auto fan. NOTES: ① Under Dry mode, fan speed is low and can’t be adjusted. ② When the wired controller is connected with a Fresh Air Indoor Unit, fan speed of indoor unit will be high fan speed only. Fan speed of indoor unit can’t be adjusted via “FAN” button. ③ If indoor unit’s fan speed is set auto, indoor unit will change fan speed automatically according to room temperature in order to make the room temperature more stable and comfortable. 6.6.2 Air Setting* Air Function: Adjust the amount of indoor fresh air to improve air quality and keep indoor air fresh. Turn on air function: Under on or off status, select the air function on the function page and then press “◀” or “▶” button to turn on or turn off the air function. Owner’s Manual 38
Owner’s Manual Cancel air function: Same as the method used for turning on the air function. When selecting the air function on the function page, press “Menu/OK” button to go air level setting. The display is as below: Fig. 6.6 Air level setting Press “▲” or “▼”button can adjust the air level in the range of level 1~10. Press “Menu/OK” button to save the setting. NOTES: ① Air function is only effective for units with air function and fresh air motorized air valve (abbr. fresh air valve). ② The following table indicates the opening time of fresh air valve per unit of time (60 min) corresponding to the level of air setting. Opening time of fresh air valve is the initial N minutes per unit of time. Example: The level of air setting is set to 1, and then unit starts timing and fresh air valve is open. 6 minutes later, fresh air valve is closed and the unit keeps running. After timing for 60 minutes, unit restarts timing and fresh air valve is open again. 6 minutes later, the valve is closed and the cycle repeats. 39
Owner’s Manual Level of Air setting 1 2 3 4 5 6 7 8 9 10 Opening time 60 /6 60 /12 60 /18 60 /24 60 /30 60 /36 60 /42 60 /48 60 /54 Always of fresh air on valve NOTE: Time indicated in the table: unit’s operating time (min) / opening time of fresh air valve per operating time (min). 6.6.3 Sleep Setting Sleep Function: The unit will operate according to the preset sleep curve to provide comfortable sleep environment. Turn on sleep function: Under on status, select sleep function on the function page and then press “◀” or “▶” to turn on or turn off the sleep function. Cancel sleep function: Same as the method used for turning on the sleep function. When sleep function is activated, “ ” icon is bright; quiet or auto quiet mode is also activated. Under Auto, Fan or Floor Heating mode, the sleep function is not available. 6.6.4 Health Setting* Health function: Control the air purification module which can purify the air. This function cannot be used under Floor Heating mode. Turn on health function: Under on status, select the health function on the function page and then press “◀” or “▶” to turn on or turn off the health function. Cancel health function: Same as the method used for turning on 40
Owner’s Manual the health function. 6.6.5 I-Demand Setting* I-DEMAND function: The unit operates in the SE mode to save energy. I-DEMAND function can only be used under cooling mode. Turn on I-Demand function: When the unit is turned on, under cooling mode, select I-Demand on the function page, and then press “◀” or “▶” button to turn on or turn off I-Demand function. Cancel I-Demand function: Same as the method used for turning on the I-Demand function. NOTE: It is only applicable to U-Match unit. 6.6.6 Absence Setting Absence function: This is used to maintain indoor temperature so that unit can realize fast heating after it is turned on. This function can only be used under heating mode. Turn on absence function: Under heating mode, select absence function on the function page and then press “◀” or “▶” button to turn on or turn off the absence function. Cancel absence function: Same as the method used for turning on the absence function. 6.6.7 Save Setting Save function: Air conditioner can be operated in small temperature range by setting the minimum temperature under Cooling and Dry modes and setting maximum temperature under Heating, 3D Heating and Space Heating modes. Thus, energy saving can be realized. 41
Turn on save mode: Under on status, select save function on the function page and press “◀” or “▶” button to turn on or turn off the save function. Cancel save mode: Same as the method used for turning on the save function. When selecting save function on the function page, press “Menu/OK” button to set temperature for save function. The display is as below: Fig. 6.7 Temperature setting for save function Press “▲” or “▼”button to switch items. When selecting the first item, press “◀” or “▶” button to switch modes; when selecting the second item, press “◀” or “▶” button to switch temperature lower limit and upper limit value. Press “Menu/OK” button to save the setting and then turn back to the previous page. When save function is turned on, icon “ ” is displayed under all modes at on and off statuses. Owner’s Manual 42
Owner’s Manual NOTE: When the save function is turned on and then set temperature exceeds the limit value for save function, “ ” icon blinks three times and then buzzer will give out two sounds successively. 6.6.8 X-FAN Setting X-fan function: If the unit is turned off under Cooling or Dry mode, the evaporator of indoor unit will be dried off automatically to prevent bacteria and mould from gathering. Turn on X-fan function: When the unit is turned on, select X-fan function on the function page under cooling or dry mode and press “◀” or “▶” button to turn on or turn off X-fan function. Cancel X-fan: Same as the method used for turning on the X-fan function. 6.6.9 Filter Clean Reminder Setting Filter Clean Reminder Function: The unit will remember its own operating time. When the setting time is over, this function will remind you to clean the filer. A dirty filter will result in bad heating and cooling performance, abnormal protection, bacteria gathering, etc. Select “Clean Remind” on the function page and press “Menu/OK” button to go to filter clean reminder setting page. Refer to the figure as below: 43
Fig 6.8 Filter clean reminder setting Press “▲” or “▼”button to switch items. When selecting the first item, press “◀” or “▶” button to turn on or turn off this function; when selecting the second item, press “◀” or “▶” button to switch current environmental cleanliness (switch among level 1, level 2 and level 3. There are for good, general and bad cleanliness); when selecting the third item, press “◀” or “▶” button to adjust the cleaning period . Press “Menu/OK” button to save the setting and then turn back to the previous page. There are four circumstances while cleaning period Setting: Turn off clean reminder; Light pollution: When current cleanliness is “1”, the setting range for the clean cycle is 5500h-10000h. After each pressing of “▶” button, the accumulated time will increase 500h. When the time exceeds the maximum value, it will turn back to the minimum value. Medium pollution: When current cleanliness is “2”, the setting range for the clean cycle is 1400h-5000h. After each pressing of “▶” Owner’s Manual 44
Owner’s Manual button, the accumulated time will increase 400h. When the time exceeds the maximum value, it will turn back to the minimum value. Serious pollution: When current cleanliness is “3”, the setting range for the clean cycle is 100h-1000h. After each pressing of “▶” button, the accumulated time will increase 100h. When the time exceeds the maximum value, it will turn back to the minimum value. NOTES: When clean time is reached, icon“ ”at the status column will be displayed. The reminding will pop up at the home page to remind users to clean the filter. Click “Done” or “Skip” to cancel the display. At the same time, the accumulated time for “filter clean reminder” will be cleared and the time will be counted again. 6.6.10 Quiet Setting Quiet function: Decrease the noise of indoor unit and achieve the quiet effect. Quiet function has two modes: quiet mode and auto quiet mode. It is available only in Auto, Cooling, Dry, Fan, Heating, 3D heating and Space heating modes. Turn on quiet function: Under on status, select the quiet function on the function page and press “◀” or “▶” button to turn on or turn off the quiet function. Cancel quiet function: Same as the method used for turning on the quiet function. When selecting quiet function on the function page, press “Menu/OK” button to set the quiet mode. The display is as below: 45
Fig. 6.9 Quiet mode setting Press“▲”or “▼” button can adjust the quiet mode (quiet mode and auto quiet mode). Press “Menu/OK” button to save the setting. NOTES: ① When quiet function is enabled, indoor unit will operate at quiet fan speed. Fan speed is lowered so as to reduce the noise of indoor fan motor. ② When auto quiet function is enabled, indoor unit will change fan speed automatically according to room temperature. After room temperature reaches a set point, the unit will operate at quiet fan speed. 6.6.11 Low-temperature Dry Function Setting Low-temperature dry function: It can be turned on under the dry mode. When the dry function is turned on, the set temperature is changed to12°C. Turn on low-temperature dry function: When the unit is turned on, under dry mode, select the “12-Drying” function at the function page Owner’s Manual 46
Owner’s Manual and then press “◀” or “▶” button to turn it on or turn it off. Cancel low-temperature dry function: Same as the method of turning on the low-temperature dry function. 6.6.12 Setback Function In unit off status with setback function activated, the unit will operate in heating mode automatically when indoor temperature is lower than temperature lower limit for setback function and operate in cooling mode automatically when indoor temperature is higher than temperature upper limit for setback function, so as to keep indoor temperature within the temperature upper and lower limit range for setback function. When turning on the setback function, the icon“ ”will be displayed on the homepage. Under off status, when setback function is operating, the icon “ ”blinks. As for setting related parameters of setback, it needs to go to user parameters page. Please refer to 5.2.2 parameters setting for the method. Turn on setback function: Under on or off status, select setback function on the user parameter page, and press “◀” or “▶” button to turn on or turn off the setback function. Press “Menu/OK” button to save the setting. Cancel setback function: Same as the method used for turning on the setback. 47
Set setback temperature: Setback Upper Temp Limit: select “Upper Temp Limit of Setback” on the user parameters page, and press “◀” or “▶” button to adjust the upper temperature limit of setback function. Press “Menu/OK” button to save the setting. Setback Lower Temp Limit: select “Lower Temp Limit of Setback” on the user parameter page, and press “◀” or “▶” button to adjust the lower temperature limit of setback function. Press “Menu/OK” button to save the setting. NOTES: ① Setback function is forbidden as defaulted; ② When the slave indoor unit is operating in setback function, it cannot operate in the mode which is in conflict with that of master indoor unit. ③ If you want to activate setback function, you cannot use the wired controllers of other models as the master wired controller or slave master controller. ④ When all shield function of remote monitor or central controller is turned on, the wired controller can’t enter or exits from the setback function. ⑤ When the unit is operating at setback function, the slave wired controller cannot set save function and doesn’t display or receive save setting. 6.6.13 DRED Function Setting * DRED function: The unit operates under save mode. This Owner’s Manual 48
Owner’s Manual function can be turned on under cooling, heating, auto and dry modes. Turn on DRED function: Under on status, select DRED on the function page and then press “◀” or “▶” button to turn on or turn off DRED function. Cancel DRED: Same as the method used for turning on DRED function. When selecting DRED on the function page, press “Menu/OK” button to go to DRED mode setting. The display is as below: Figure 6.10 DRED mode setting Press “▲” or “▼”button to switch between DRED mode 2 and DRED mode 3. Press “Menu/OK” button to save the setting. NOTE: It is only applicable to U-Match unit. 6.6.14 Independent Swing Function Setting* Turn on independent swing function: Select the independent swing on the function page under on status, and press “◀” or “▶” button to turn on or turn off the independent swing function. Cancel independent swing: Same as the method used for turning 49
on the independent swing function. When turning on the independent swing, select the independent swing on the function page and press “Menu/OK: button to go to the independent swing setting. The display is as below: Fig 6.11 Independent swing setting Press “▲” or “▼”button to select the air outlet (air outlet 1, air outlet 2, air outlet 3 and air outlet 4). Press “◀” or “▶” button to switch the swing status of corresponding air outlet. Press “Menu/OK” button to save the setting. The swing status is shown as blow: Fig. 6.12 Swing status NOTES: ① This function is only applicable to cassette type unit. ② Up&down swing is only applicable for independent swing function. Owner’s Manual 50
Owner’s Manual ③ As for the independent swing, one air outlet at the most can be set closed. When the air outlet is closed, it can’t supply the air outlet. ④ Turning off the independent swing can restore to the original up&down swing setting. When independent swing function is turned on, independent swing icon “ ” will be displayed at the status column on the homepage. 6.6.15 Auto Clean Function* Turn on auto clean function: Select auto clean function on the function page and then press “◀” or “▶” button to turn on or turn off the auto clean function. When turning on the auto clean function, press other buttons to turn back to the homepage. Cancel auto clean: Function page: Same as the method used for turn on the auto clean function. Homepage: Press any buttons and a pop-up window will appear and then press “ ” button. When auto clean function is turned on while the unit hasn’t enter into auto clean operation, “ ”is bright; when the unit has officially entered into auto clean status, “ ” blinks. The remaining time of auto clean mode is displayed at the temperature area. When existing the auto clean function, the remaining time for auto clean mode won’t be displayed at the temperature area. Some time later, icon“ ”will be off and the auto clean is existed. 51
NOTES: ① This function is only applicable to the unit with auto clean function. ② When the unit is faulty, auto clean function cannot be turned on. ③ When auto clean function is turned on, there will be some phenomenons, such as frosting of evaporator of indoor unit, sound of liquid flow, and fluctuation of indoor temperature and humidity, which will affect the comfort. Auto clean function is recommended to be used when there are no people in the room. In order to ensure the cleaning effect, it is recommended to turn on auto clean function every three months. ④ The auto clean effect will be weakened if indoor environment humidity is low. ⑤ It is recommended to use auto clean function at the outdoor ambient temperature of 10 ℃~40 ℃. Otherwise, auto clean function will exit in advance, which is the normal phenomenon. ⑥ When an indoor unit in VRF system has entered into the auto clean mode, all other units in the system will operate under the auto clean mode. ⑦ When the wired controller controls U-Match unit, auto clean function can only be turned on under OFF status. The remaining time of the auto clean mode won’t be displayed at the timer zone. 6.6.16 Remote Shield Function Remote shield function: Remote monitor or central controller can disable the relevant functions of wired controller so as to realize the function of remote control. Owner’s Manual 52
Owner’s Manual When the remote monitor or central controller activates remote shield on the wired controller, icon “ ” will show. If user wants to control it through the wired controller, icon “ ” will blink to remind that these controls are disabled. 6.6.17 Gate-Control Function When there is gate-control system, user can insert a card to turn on the unit or pull off a card to turn off the unit. When the card is re- inserted, the unit will recover the operation as state in memory. When the card is pulled off (or improperly inserted), icon “ ” will show. Neither remote control nor operation of wired controller will be effective and icon “ ” will blink. NOTE: This model cannot be connected with gate control system on its own because it cannot detect gate control signal directly. To realize gate control display and gate control function, it has to be used with the wired controller that includes gate control signal detecting function (used as master and salve wired controllers). 6.6.18 I-SENSE Function Setting* I-SENSE function:After setting I-SENSE function, I-SENSE device is automatically turned on for detection. The air conditioner will automatically detect the perceived temperature and then the comfortable status will be realized rapidly. The air conditioner automatically control the angle of air guide louver as well as the swing angle. After I-SENSE has been set, when the air conditioner detected that there is no people in the room, it will automatically go to the save mode. 53
Turn on I-SENSE function: Turn on the unit, when it is in cooling or heating mode, select I-SENSE in the function page, and then press “◀” or “▶” to turn on or turn off I-SENSE function. Cancel I-SENSE: Same as the method used for turning on I- SENSE function. When selecting I-SENSE in the function page, press “Menu/OK” button to enter the setting of I-SENSE mode, it will display as below: Fig. 6.13 Setting of I-SENSE mode Press “▲” or “▼” button to switch I-SENSE mode. It can switch to Smart, Follow, Avoid, and Surround. After selecting the proper mode, press “Menu/OK” button to save the setting. NOTE: ① This function can only be set after installing Smart Sensor. ② Only version 3 and above version support this function. 6.7 Universal Setting Press “Menu/OK” button on the homepage to go to the menu page and then select “set’ to enter into set page; please refer to the Owner’s Manual 54
Owner’s Manual figure as below: Fig. 6.14 Set page Below parameters can be set on the set page. 6.7.1 WiFi Function Setting "GREE+" App can be used to control wired controller XE7C- 24/HC. Please scan the QR code or search "GREE+" in the application market to download and install it. When "GREE+" App is installed, register the account and add the device to achieve long- distance control and LAN control of Gree smart home appliances. App can only set some common functions of wired controller: ON/OFF, mode, set temperature, fan speed, etc. When using the App for the first time, please reset the WiFi function of wired controller (reset WiFi to ex-factory setting): Reset WiFi: Press “Menu/OK” button on the homepage to go to menu page to select “set” to go to the set page; Select “reset WiFi” on the set page to go to WiFi reset page. Please refer to the figure as below: 55
Fig. 6.15 WiFi set page Press “◀” or “▶” button to select it: “yes” indicates WiFi resetting. When “reset WiFi” on the setting page has changed to “reset succeeded” or WiFi icon on the homepage flashes at the interval of 0.5s, WiFi resetting is succeeded. After that, add devices to the App. NOTES: ① This function is only applicable to wired controller XE7C-24/HC. ② If the device is offline or router’s name and password have been changed, please reset WiFi and add the device again. ③ WiFi networking performance is related to the distance between the wired controller and the router and the obstacles between them. During the installation process, the distance between the wired controller and the router should be as close as possible, and the obstacles should be as little as possible. If the WiFi signal is not good, use the WiFi signal enhanced router. The specific situation depends on the actual installation. ④ For more information, please refer to "Help" in App. Owner’s Manual 56
Owner’s Manual 6.7.2 Time Format Setting Users can set 12-hour time format or 24-hour time format. Press “▲” or “▼”button on the setting page to select “time format” and then press “◀” or “▶” button to select 12-hour time format or 24-hour time format. 6.7.3 System Time Setting Select “clock” item on the setting page and then press “Menu/OK” button to go to time setting page. See the figure as below: Fig. 6.16 Clock setting page Press “◀” or “▶” button to select setting items: hour, minute, year, month and day; press “▲” or “▼”button to set the value. When setting is finished, press “Menu/OK” button to save the setting. 6.7.4 Temperature Precision Setting Users can set the temperature precision as 0.5°C or 1°C. Press “▲” or “▼” button to select “set temperature precision” on the setting page and then press “ ◀” or “ ▶” button to select two different temperature precision. 57
Owner’s Manual 6.7.5 Temperature Unit Setting Users can set the temperature unit on the wired controller as °C or℉. Press “▲” or “▼”button to select “In℉” on the setting page; press “◀” or “▶” button to select whether use℉. If not, the temperature unit on the wired controller will switch to °C. 6.7.6 Child Lock Setting Users can set the child lock on the setting page. When child lock is turned on, other buttons are all invalid. At the same time, LCD flashes to display the icon“ ”for three times. Users need to unlock it according to the instruction in the pop-up widow. Press “▲” or “▼”to select “ lock” on the setting page and then press “◀” or “▶” button to turn on the child lock or not. 6.7.7 Display Language Setting Users can select the language on the setting page. Press “▲” or “▼”button to select “language selection”; press “menu/OK” button to go to language setting page. Press “▲” or “▼” button to select the required language item. Finally, press “menu/OK” button to save the setting. 6.8 Timer Setting The wired controller can set four times of timer: daily timer, weekly timer, two-week timer and timer off. Users select the timer icon on the menu page and then press “▲” or “▼”button to select the timer. Press “◀” or “▶” button to turn on or turn off this timer. Press “Menu/OK” button to go to corresponding timer setting page. The figure is as below: 58
Owner’s Manual Fig. 6.17 Timer setting page 6.8.1 Daily Timer Setting As for the daily timer setting, users can set four independent timer periods. Only when the timer period is turned on, it is valid. As for each timer period, it can set time, on/off, working mode, set temperature and fan speed. See the figure as below: Fig. 6.18 Daily timer setting page When entering to daily timer setting page, press “◀” or “▶” button to select the setting item, press “▲” or “▼”button to set the value and then press “Menu/OK” button to save the setting. 59
Owner’s Manual 6.8.2 Weekly Timer Setting Users can set the timer for each day in a week, and they can also set 4 timer periods for each day. The unit will execute corresponding timer setting on weekly basis circularly. When entering weekly timer setting page, press “◀” or “▶” button to select one day in a week, press “Menu/OK” button to go to its timer setting, press “◀” or “▶” button to select the item, press “▲” or “▼”button again to adjust the setting content and then press “Menu/OK” button to save the setting. When all timer settings have been saved, press “ ”button to exit from this page. Please refer to the figure as below: 60
Owner’s Manual Weekly Week SUN MON TUE WED THU FRI SAT Sch Time On/Off Mode Temp Fan 1 Off 0:00 Off Cool 20℃ Auto 2 Off 0:00 Off Cool 20℃ Auto 3 Off 0:00 Off Cool 20℃ Auto 4 Off 0:00 Off Cool 20℃ Auto Menu/OK Back FAN MENU OK SWING MODE Enter weekly timer setting page Press "▲"button or"▼"button to select one day in a week to set timer Press "▲"button or"▼"button to adjust the setting content Press "Menu/OK" button to enter timer setting of this day 61
Owner’s Manual Fig. 6.19 Weekly timer setting When entering to weekly timer setting page, press “◀” or “▶” button to select the setting item, press “▲” or “▼”button to set the value and then press “Menu/OK” button to save the setting. 6.8.3 Two-week Timer Setting Users can set the timer for each day in two weeks and they can also set 4 timer periods for each day. The unit will execute corresponding timer setting on two-week circularly. Select “two week” on the timer interface and then press “Menu/OK” button to enter into two-week timer menu. Please refer to the figure as below. 62
Owner’s Manual Fig. 6.20 Two-week timer menu Select the item of “two week schedule”, press “Menu/OK” button to enter into its setting page, select the item of “current week” and then press “◀” or “▶” button can set the current week as the first week or the second week. When entering two-week timer page, users can press “ ▲” or “▼”button to select the setting items for two-week time, and then press “Menu/OK” button to go to two-week timer setting page. When entering two-week timer setting page, press “◀” or “▶” button to select one day in two weeks, press “Menu/OK” button to go to its timer setting, press “◀” or “▶” button to select the item, press “▲” or “▼”button again to adjust the setting content and then press “Menu/OK” button to save the setting. Press “ ” button to exit from this page. Please refer to the figure as the Fig. Weekly timer setting. 6.8.4 Timer OFF Setting As for timer OFF, the unit will be turned off after operating for“x” hours. If the timer off has been set, when the unit has been turned on 63
every time, it will be turned off automatically after operation for “x” hours. When entering timer OFF page, press “▲” or “▼”button to set the time for timer OFF, set the time change at the interval of 0.5h and then press “Menu/OK” button to save the setting. If not save the setting, press “ ” button turn it back. Please refer to the figure as below. Fig. 6.21 Timer OFF Setting Page NOTE: The time is 12-hour format. The time on the timer setting page is displayed by 12-hour format. 7 Error Display When there is error during operation, the temperature display zone on the wired controller will show the error code. If several errors happen at the same time, error codes will show on the display repeatedly. NOTE: If error occurs, please turn off the unit and ask for professionals to repair it. Owner’s Manual 64
Owner’s Manual Fig.7.1shows the display of outdoor unit high pressure protection when unit is on. Fig. 7.1 Display of Outdoor Unit High Pressure Protection 7.1 Table of Error Codes for VRF and Big Duct Unit 7.1.1 Table of Error Codes for Outdoor Unit Error Code Content Error Code Content E0 Outdoor Unit Error J9 System Pressure Under- Ratio Protection 65
Owner’s Manual Error Code Content Error Code Content E1 High Pressure Protection JA Protection of Abnormal Pressure E2 Discharge Low Temperature Protection JC Protection of Water Flow Switch E3 Low Pressure Protection JL Protection of Low High- pressure Excess Discharge Temperature Protection JE Oil Return Pipe is E4 Blocked of Compressor Low Temperature Protection of Driver Ed JF Oil Return Pipe is Leaking Module F0 Bad Performance of the Outdoor Mainboard JJ Low Water-in Temperature Protection F1 High Pressure Sensor Error b1 Outdoor Ambient Temperature Sensor Error Inlet Tube Temperature b2 Defrosting Temperature F2 Sensor Error of Plate Type Heat Exchanger Sensor 1 Error F3 Low Pressure Sensor Error b3 Defrosting Temperature Sensor 2 Error Outlet Tube Temperature Sensor b4 Subcooler Liquid-out Temperature Sensor Error F4 Error of Plate Type Heat Exchanger 66
Owner’s Manual Error Code Content Error Code Content Compressor 1 Discharge Temperature F5 Sensor Error Compressor 2 Discharge Temperature F6 Sensor Error Compressor 3 Discharge Temperature F7 Sensor Error Compressor 4 Discharge Temperature F8 Sensor Error Compressor 5 Discharge Temperature F9 Sensor Error Compressor 6 Discharge Temperature FA Sensor Error FC Compressor 2 Current Sensor Error bH System Clock Malfunction FL Compressor 3 Current Sensor Error bE FE Compressor 4 Current Sensor Error bF b5 Subcooler Gas-out Temperature Sensor Error b6 Gas-liquid Separator Inlet Temperature Sensor Error Gas-liquid Separator b7 Outlet Temperature Sensor Error b8 Outdoor Humidity Sensor Error b9 Heat Exchanger Gas-out Temperature Sensor Error bA Oil-return Temperature Sensor Error Malfunction of Entry Tube Temperature Sensor of Condenser Malfunction of Exit Tube Temperature Sensor of Condenser 67
Owner’s Manual Error Code Content Error Code Content High and Low Pressure Sensors are Connected FF Compressor 5 Current Sensor Error bJ Inversely FJ Compressor 6 Current Sensor Error bP Oil-return 2 Temperature Sensor Error FP Malfunction of DC motor bU Oil-return 3 Temperature Sensor Error Compressor 1 Top Temperature Sensor bb Oil-return 4 Temperature FU Sensor Error Error Compressor 2 Top Temperature Sensor bd Air-in Temperature Sensor Error of Subcooler Fb Error Mode Exchanger Outlet bn Liquid-in Temperature Sensor Error of Subcooler Fd Pipe Temperature Sensor Error Mode Exchanger Inlet by Water-out Temperature Fn Pipe Temperature Sensor Error Sensor Error Fy Water-in Temperature Sensor Error P0 Compressor Drive Board Error J1 Compressor 1 Over- current Protection P1 Compressor Drive Board Malfunction Protection of Compressor J2 Compressor 2 Over- current Protection P2 Drive Board Power Supply 68
Owner’s Manual Error Code Content Error Code Content J3 Compressor 3 Over- current Protection P3 J4 Compressor 4 Over- current Protection H0 Error of Fan Drive Board J5 Compressor 5 Over- current Protection H1 Malfunction of Fan Drive J6 Compressor 6 Over- current Protection H2 Protection of Fan Drive J7 4-way Valve Blow-by Protection GH PV DC/DC Protection J8 System Pressure Over- Ratio Protection — — 7.1.2 Table of Error Codes for Indoor Unit Error Code Content Error Code Content L0 Indoor Unit Error dL Outlet Air Temperature Sensor Error L1 Indoor Fan Protection dE Indoor Unit CO2 Sensor Error L2 E-heater Protection db Special Code: Field Debugging Code L3 Water Full Protection dn Swing Assembly Error L4 Wired Controller Power Supply Error dy Water Temperature Sensor Error L5 Anti-Frosting Protection y1 Inlet Pipe Temperature Sensor 2 Error Protection of Compressor Drive Board Module Reset Board Board Power Supply 69
Error Code Content Error Code Content L6 Mode Conflict y2 Outlet Pipe Temperature Sensor 2 Error L7 No Master Indoor Unit Error y3 Middle Tube Temperature Sensor 2 Error L8 Power Insufficiency Protection y7 Fresh Air Inflow Temperature Sensor Error Quantity Of Group Control Indoor Units Setting Error L9 LA Indoor Units Incompatibility Error y9 Outdoor Air Box Sensor Error LH Low Air Quanlity Warning yA IFD error LC Outdoor-Indoor Incompatibility Error yH Fresh Air-out Sensor Error LF Shunt Valve Setting Error yC Air-return Inlet Sensor Error LJ Wrong Setting of Function DIP Switch yL Air-return Outlet Temperature Sensor Error Zero-crossing Malfunction of PG Motor LP Inconsistent Branch of Group-controlled Indoor Units in Heat Recovery System LU Owner’s Manual y8 Indoor Air Box Sensor Error yE High Liquid Level Switch Error yF Low Liquid Level Switch Error 70
Owner’s Manual Error Code Content Error Code Content Inconsistency of Group- controlled Indoor Units in Reheat Dehumidification System Lb Ld Indoor Fan 2 Error o1 Low Voltage of IDU Bus Bar Ln Lift Panel Return Air Frame Reset Exception o2 High Voltage of IDU Bus Bar d1 Indoor Unit PC-Board Error o3 IDU IPM Module Protection d3 Ambient Temperature Sensor Error o4 IDU Startup Failure d4 Inlet Pipe Temperature Sensor Error o5 IDU Overcurrent Protection Malfunction of Middle Tube Temperature Sensor d5 Outlet Pipe Temperature Sensor Error d6 d7 Humidity Sensor Error o8 IDU Driver Communication Error d8 Water Temperature Abnormality o9 o0 Motor Drive Error o6 IDU Current Detective Electric Circuit Error o7 IDU Losing Step Protection Communication Error between IDU Main Control and IDU Drive Board 71
Error Code Content Error Code Content d9 Jumper Cap Error oA High Temperature of IDU Module dA Indoor Unit Hardware Address Error oC IDU Charging Circuit Error dH Wired Controller PC- Board Error ob Temperature Sensor Error of IDU Module dC Capacity DIP Switch Setting Error — — 7.1.3 Table of Debugging Codes Error Code Content Error Code Content Outdoor Unit Capacity Code/Jumper Cap Setting Error U2 Phase Sequence Protection of Power Supply U3 U4 Protection of Lack of Refrigerant C2 Owner’s Manual Communication between indoor unit and outdoor unit and the communication between indoor unit and wired controller have malfunction C0 C1 Communication error of expansion board Communication error between master control and inverter compressor drive 72
Owner’s Manual Error Code Content Error Code Content Wrong Address of Compressor Drive Board U5 U6 Valve Abnormal Alarm C4 Error of Lack of Indoor Unit U7 Grid DRED0 Response Protection C5 Alarm of Indoor Unit Project Number Collision U8 Indoor Unit Tube Malfunction C6 Alarm of Wrong Number of Outdoor Unit U9 Outdoor Unit Tube Malfunction C7 Mode Exchanger Communication Error Overvoltage Protection of DC Bus Bar in Power Grid Side UA Under voltage Protection of DC Bus Bar in Power Grid Side UH UC Master indoor unit is successfully set CL Rated capacity is too low Emergency Operation DIP switch setting of the compressor is wrong UL UE Refrigerant Charging is ineffective CF Error of Multiple Master Indoor Unit Communication error between master control and inverter fan motor drive C3 CH Rated capacity is too high CC No master control unit error Communication Failure Between Mode Exchanger and Indoor Unit CE 73
Error Code Content Error Code Content Indoor Unit Identification Error of Mode Exchanger UF UJ PV module F0 protection CP Error of Multiple Master Wired Controller Protection shutdown error of thermal storage module UP Electronic expansion valve leak error of thermal storage module UU Protection without shutdown error of thermal storage module Ub Ud Grid-connection driver board error Cn Communication error between grid- connection driver board and master controller Un Uy PV module overheating protection — — Owner’s Manual CJ System addresses is incompatible Communication Error between Indoor Unit and Remote Receiver CU Cb Outflow of Units IP Address Communication Failure Between Mode Exchanger and Outdoor Unit Cd Indoor and Outdoor Network Error of Mode Exchanger Communication Error of No Master in Mode Exchanger Cy 74
Owner’s Manual 7.1.4 Table of Status Codes Error Code Content Error Code Content A0 Unit is waiting for debugging Ay Shielding status A1 Check the compressor operation parameters n3 Compulsory defrosting A2 After-sales Refrigerant Reclaim q5 A3 Defrosting q7 Select degree Celsius or Fahrenheit A4 Oil return q8 A5 Online Testing q9 Setting of defrosting mode A8 Vacuum-pumping Mode qL Setting of static pressure A9 Operate in Setback Function qE EVI Operating Mode AH Heating qF System compulsory cooling mode AC Cooling qP PV GMV Unit export area setting AF Fan qU Grid voltage system configuration AJ Filter Clean Reminder qb Anti-condensation temperature setting Setting of ordinary units and high sensible heat units Discharge low temperature protection revision value b 75
Error Code Content Error Code Content AU Remote Urgent Stop qd Setting of target degree of super-cooling of ODU Ab Emergency Stop qn PV grid-connected settings Ad Operation Restriction qy Working mode of compressor heating belt An Lock status — — 7.2 Table of Display Codes for U-Match Unit 7.2.1 Table of Error Codes of Outdoor Unit Error Code Content Error Code Content E4 Discharge Protection LA Outdoor Fan 2 Error H4 Overload Protection L3 Outdoor Fan 1 Error PA ODU AC Current Protection E3 System Low Pressure Protection H5 Module Current Protection E1 System High Pressure Protection P8 Module Temperature Protection U3 DC Bus Voltage Drop Error E2 Freeze Protection U5 Current Detecting Error of Complete Unit L9 High Power Protection PU Capacitor Charging Error Compressor Phase Loss/Phase Reversal/Out of Phase U2 Owner’s Manual Compressor Phase Current Circuit Detecting Error U1 76
Owner’s Manual Error Code Content Error Code Content HC PFC Overcurrent Error H7 Compressor Non- synchronism PH High Voltage Protection of DC Bus HE PL Low Voltage Protection of DC Bus LE Compressor Stalling Lc Startup Failure P6 Drive Board Communication Error Overcurrent of Compressor Phase Current LF Overspeed PP DC Input Voltage Error P0 Drive Module Reset P5 Compressor DIP Switch/Jumper Cap Error C8 Drive Board Ambient Temperature Sensor Error PF P9 AC Contactor Protection b7 Gas Valve Temperature Sensor Error PE Temperature Shifting Protection A5 Compressor Demagnetization Protection Abnormal Outdoor Ambient Temperature (heating at too high ambient temperature or cooling at too low ambient temperature) Uo b5 Liquid Valve Temperature Sensor Error Outdoor Condenser Inlet Pipe Temperature Sensor Error 77
Error Code Content Error Code Content Sensor Connection Protection (current sensor hasn’t been connected to corresponding U phase or V phase) Pd e3 Low Pressure Sensor Error A4 Refrigerant Temperature Sensor Error C7 Outdoor Pipe Middle Sensor Error A3 ODU Refrigerant Heater Failure E1 High Pressure Switch 2 Error A2 ODU Refrigerant Heater Relay Adhesion Error C9 Compressor Drive Storage Chip Error E6 Communication Error between ODU and IDU Ad Outdoor Fan Out-of- phase Protection C4 ODU Jumper Cap Error AE Outdoor Fan Current Detecting Circuit Error dJ Ac Outdoor Fan Startup Failure e1 High Pressure Sensor Error AJ Outdoor Fan Non- synchronism Protection UL Outdoor Fan Overcurrent Protection EL Emergency Operation Stop A1 Outdoor Fan IPM Module Protection oE Other Error of Compressor C6 Discharge Temperature Sensor Error Owner’s Manual Outdoor Condenser Outlet Pipe Temperature Sensor Error A7 AC Phase Sequence Protection (phase loss or phase reversal) 78
Owner’s Manual Error Code Content Error Code Content Compressor Suction Temperature Sensor Error dc P7 Module Temperature Sensor Circuit Error U7 4-way Valve Commutation Error U8 Zero-crossing Signal Error Cd Abnormal Electrical Level of Selected Port Outdoor Ambient Temperature Sensor Error F3 E3 Refrigerant Lacking Protection — — 7.2.2 Table of Error Codes of Indoor Unit Error Code Content Error Code Content E0 Indoor Fan Error L1 Indoor Humidity Sensor Error Inverter Indoor Fan Drive Current Detecting Circuit Error qA Indoor Ambient Temperature Sensor Error C1 Indoor Evaporator Middle Temperature Sensor Error C2 Outdoor Condenser Middle Pipe Temperature Sensor Error C3 EE Memory Chip Read and Write Error Main Control and Inverter Indoor Fan Drive Communication Error qC Inverter Indoor Fan Drive Module High Temperature Protection qd Inverter Indoor Fan Drive Module Temperature Sensor Error qE 79
Error Code Content Error Code Content E9 IDU Water Full Protection qF Inverter Indoor Fan Drive Storage Chip Error CJ IDU Jumper Cap Error qH Inverter Indoor Fan Drive Charging Circuit Error Inverter Indoor Fan Drive IPM Module Protection q3 Low Voltage Protection or Voltage Drop Error of Inverter Indoor Fan Drive DC Bus q0 High Voltage Protection of Inverter Indoor Fan Drive DC Bus q1 Inverter Indoor Fan AC Current Protection (input side) q2 q4 Inverter Indoor Fan Drive PFC Protection qb Inverter Indoor Fan Non- synchronism Protection q5 Inverter Indoor Fan Startup Failure CP Multiple Master Wired Controllers Error q6 Inverter Indoor Fan Out-of-phase Protection L5 q7 Inverter Indoor Fan Drive Module Reset L7 Group-controlled IDU Series Inconsistency Owner’s Manual Inverter Indoor Fan Drive AC Input Voltage Abnormal Protection qL Inverter Indoor Fan Drive Electric Box Temperature Sensor Error qo Inverter Indoor Fan Drive AC Input Zero-crossing Protection qp Communication Error between Indoor Unit and Wired Controller C0 Wired Controller Power Supply Overcurrent Protection 80
Owner’s Manual Error Code Content Error Code Content q8 Inverter Indoor Fan Overcurrent Protection CE q9 Inverter Indoor Fan Power Protection dH Wired Controller Circuit Board Error L4 Wired Controller Power Supply Circuit Failure Lb L6 Group-controlled IDU Quantity Inconsistency — — 7.2.3 Table of Status Codes Status Code Content Status CL Auto clean d1 DRED operation mode 1 Fo Refrigerant recycle mode d2 DRED operation mode 2 H1 Ordinary defrosting status d3 DRED operation mode 3 Wired Controller Temperature Sensor Error Group-controlled IDU Inconsistency of Reheat Dehumidification System Code Content 81
GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: global@cn.gree.com www.gree.com 600005067336