Change for life Service Manual GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI
Table of Contents Part Ⅰ: Technical Information.......................................................................1 1. Summary.......................................................................................................................1 2. Specifications...........................................................................................................3 2.1 Specification Sheet...........................................................................................................3 2.2 Operation Characteristic Curve.........................................................................................7 2.3 Capacity Variation Ratio According to Temperature..........................................................7 2.4 Noise Curve......................................................................................................................8 3. Outline Dimension Diagram.........................................................................................9 3.1 Indoor Unit........................................................................................................................9 3.2 Outdoor Unit....................................................................................................................10 4. Refrigerant System Diagram.....................................................................12 5. Electrical Part.........................................................................................................13 5.1 Wiring Diagram...............................................................................................................13 5.2 PCB Printed Diagram......................................................................................................17 6. Function and Control.......................................................................................20 6.1 Remote Controller Introduction ......................................................................................20 6.2 GREE+ App Operation Manual.......................................................................................24 6.3 Ewpe Smart App Operation Manual................................................................................25 6.4 Brief Description of Modes and Functions......................................................................26 Part Ⅱ: Installation and Maintenance ..................................................28 7. Notes for Installation and Maintenance..........................................28 8. Installation.................................................................................................................32 8.1 Requirements for Electric Connection............................................................................32 8.2 Installation of indoor unit.................................................................................................32 8.3 Outdoor Unit Installation.................................................................................................38 8.4 Vacuum Pumping and Leak Detection............................................................................39 8.5 Check after Installation and Test Operation....................................................................39 9. Maintenance............................................................................................................40 9.1 Error Code List................................................................................................................40 9.2 Procedure of Troubleshooting.........................................................................................47 9.3 Maintenance Method for Normal Malfunction.................................................................60 Service Manual Table of Contents
Service Manual 10. Exploded View and Parts List...............................................................62 10.1 Indoor Unit....................................................................................................................62 10.2 Outdoor Unit..................................................................................................................65 11. Removal Procedure........................................................................................71 11.1 Removal Procedure of Indoor Unit................................................................................71 11.2 Removal Procedure of Outdoor Unit.............................................................................75 Appendix:.........................................................................................................................90 Appendix 1: Reference Sheet of Celsius and Fahrenheit.....................................................90 Appendix 2: Configuration of Connection Pipe.....................................................................90 Appendix 3: Pipe Expanding Method....................................................................................91 Appendix 4: List of Resistance for Temperature Sensor.......................................................92 Table of Contents
Service Manual Part Ⅰ: Technical Information 1. Summary Indoor Unit GEH12AA-K6DNA1A/I GEH09AA-K6DNA1F/I GEH18AA-K6DNA1F/I Outdoor Unit GEH09AA-K6DNA1F/O GEH18AA-K6DNA1F/O 1 Technical Information GEH12AA-K6DNA1A/O Remote Controller YAA1FB8(WiFi)
Model List: No Model Product code Indoor model Indoor product Remote Controller 1 GEH09AA-K6DNA1F CV010002700 GEH09AA-K6DNA1F/I CV010N02700 GEH09AA-K6DNA1F/O CV010W02700 2 CV010002701 CV010N02701 3 GEH12AA-K6DNA1A CV010002900 GEH12AA-K6DNA1A/I CV010N02900 GEH12AA-K6DNA1A/O CV010W02900 4 CV010002901 CV010N02901 5 GEH18AA-K6DNA1F CV010002800 GEH18AA-K6DNA1F/I CV010N02800 GEH18AA-K6DNA1F/O CV010W02800 6 CV010002801 CV010N02801 2 Technical Information Service Manual code Outdoor model Outdoor product code YAA1FB8(WiFi)
Service Manual 2. Specifications 2.1 Specification Sheet Parameter Unit Value Model GEH12AA-K6DNA1A GEH09AA-K6DNA1F Product Code CV010002900/CV010002901 CV010002700/CV010002701 Rated Voltage V ~ 220-240 220-240 Rated Frequency Hz 50 50 Phases 1 1 Power Supply Mode Outdoor Outdoor Cooling Capacity(Min~Max) W 3520(800~4400) 2700(700~3400) Heating Capacity(Min~Max) W 3800(1100~4400) 2900(600~3500) Cooling Power Input(Min~Max) W 1000(160~1500) 720(170~1300) Heating Power Input(Min~Max) W 960(165~1500) 730(130~1350) Cooling Current Input A 4.48 3.5 Heating Current Input A 4.30 3.6 Rated Input W 1500 1350 Rated Current A 6.72 6.0 Air Flow Volume(SH/H/HM/M/LM/L/SL) m Power Supply 3/h 600/520/480/440/400/360/280 500/430/410/370/330/280/250 Dehumidifying Volume L/h 1.2 0.8 EER W/W 3.52 3.75 COP W/W 3.96 3.97 SEER W/W 7.0 7.2 SCOP(Average/Warmer/Colder) W/W 4.1/5.3/- 4.0/5.3/- Application Area m Indoor Unit Model GEH12AA-K6DNA1A/I GEH09AA-K6DNA1F/I Indoor Unit Product Code CV010N02900/CV010N02901 CV010N02700/CV010N02701 Fan Type Centrifugal Centrifugal Fan Diameter Length(DXL) mm Φ370X80 Φ370X80 Cooling Speed (SH/H/HM/M/LM/L/SL) r/min 750/650/600/550/500/450/350 650/560/530/480/430 /370/320 Heating Speed (SH/H/HM/M/LM/L/SL) r/min 750/650/600/550/500/450/350 650/560/530/480/430/370/320 Fan Motor Power Output W 30 30 Fan Motor RLA A 0.15 0.15 Fan Motor Capacitor μF / / Evaporator Form Aluminum Fin-copper Tube Aluminum Fin-copper Tube Evaporator Pipe Diameter mm Φ7 Φ7 Evaporator Row-fin Gap mm 2-1.3 2-1.3 Evaporator Coil Length (LXDXW) mm 511X400X25.4 511X400X25.4 Swing Motor Model MP24EB/MP24AE MP24EB/MP24AE Swing Motor Power Output W 1.5/1.5 1.5/1.5 Fuse Current A 3.15 3.15 Sound Pressure Level (SS/H/MH/M/ML/L/SL) dB (A) Cooling:44/40/38/36/33/29/25 Heating:44/40/38/36/33/29/25 Indoor Unit Cooling:39/36/33/31/29/26/23 Heating:38/36/32/30/28/25/22 Sound Power Level (SS/H/MH/M/ML/L/SL) dB (A) Cooling:54/50/48/46/43/39/35 Heating:54/50/48/46/43/39/35 Cooling:50/48/45/44/42/38/34 Heating:50/48/45/44/42/38/34 Dimension (WXHXD) mm 700X600X215 700X600X215 Dimension of Carton Box (LXWXH) mm 785X280X682 785X280X682 Dimension of Package(LXWXH) mm 788X283X697 788X283X697 Net Weight kg 15.5 15.5 Gross Weight kg 18.5 18.5 3 Technical Information 2 16-24 12-18
Outdoor Unit Model GEH12AA-K6DNA1A/O GEH09AA-K6DNA1F/O Outdoor Unit Product Code CV010W02900 CV010W02700 Compressor Manufacturer ZHUHAI LANDA COMPRESSOR CO., LTD Compressor Model QXF-A102zE190B QXF-A079zE190A Compressor Oil FW68DA FW68DA Compressor Type Rotary Rotary Compressor LRA. A / / Compressor RLA A 4.60 4.6 Compressor Power Input W 1023 790 Compressor Overload Protector HPC115/95U1/KSD115ºC HPC115/95U1/KSD115ºC Throttling Method Electron expansion valve Electron expansion valve Set Temperature Range ºC 16~30 16~30 Cooling Operation Ambient Temperature Range ºC -15~43 -15~43 Heating Operation Ambient Temperature Range ºC -22~24 -22~24 Condenser Form Aluminum Fin-copper Tube Aluminum Fin-copper Tube Condenser Pipe Diameter mm Φ7.94 Φ7 Condenser Rows-fin Gap mm 1-1.4 1-1.4 Condenser Coil Length (LXDXW) mm 731X19.05X550 710X19.05X508 Fan Motor Speed rpm 900 900 Fan Motor Power Output W 30 30 Fan Motor RLA A 0.36 0.36 Fan Motor Capacitor μF / / Outdoor Unit Air Flow Volume m Outdoor Unit 3/h 2200 1600 Fan Type Axial-flow Axial-flow Fan Diameter mm Φ438 Φ400 Defrosting Method Automatic Defrosting Automatic Defrosting Climate Type T1 T1 Isolation I I Moisture Protection IPX4 IPX4 Permissible Excessive Operating Pressure for the Discharge Side MPa 4.3 4.3 Permissible Excessive Operating Pressure for the Suction Side MPa 2.5 2.5 Sound Pressure Level (H/M/L) dB (A) 52/-/- 49/-/- Sound Power Level (H/M/L) dB (A) 62/-/- 60/-/- Dimension(WXHXD) mm 848X596X320 782X540X320 Dimension of Carton Box (LXWXH) mm 878X360X630 820X355X580 Dimension of Package(LXWXH) mm 881X363X645 823X358X595 Net Weight kg 30.5 27.5 Gross Weight kg 33.5 30 Refrigerant R32 R32 Refrigerant Charge kg 0.75 0.55 Connection Pipe Length m 5 5 Connection Pipe Gas Additional Charge g/m 16 16 Outer Diameter Liquid Pipe mm Φ6 Φ6 Outer Diameter Gas Pipe mm Φ9.52 Φ9.52 Max Distance Height m 10 10 Max Distance Length m 20 15 Note: The connection pipe applies metric diameter. Connection Pipe The above data is subject to change without notice. Please refer to the nameplate of the unit. 4 Technical Information Service Manual ZHUHAI LANDA COMPRESSOR CO.,LTD
Service Manual Parameter Unit Value Model GEH18AA-K6DNA1F Product Code CV010002800/CV010002801 Rated Voltage V ~ 220-240 Rated Frequency Hz 50 Phases 1 Power Supply Mode Outdoor Cooling Capacity(Min~Max) W 5200(1260~6600) Heating Capacity(Min~Max) W 5330(1120~6800) Cooling Power Input(Min~Max) W 1550(380~2450) Heating Power Input(Min~Max) W 1500(350~2500) Cooling Current Input A 7.1 Heating Current Input A 6.7 Rated Input W 2500 Rated Current A 11.1 Air Flow Volume(SH/H/HM/M/LM/L/SL) m Power Supply 3/h 700/650/580/520/460/410/320 Dehumidifying Volume L/h 1.8 EER W/W 3.4 COP W/W 3.55 SEER W/W 6.6 SCOP(Average/Warmer/Colder) W/W / Application Area m Indoor Unit Model GEH18AA-K6DNA1F/I Indoor Unit Product Code CV010N02800/CV010N02801 Fan Type Centrifugal Fan Diameter Length(DXL) mm Φ370X80 Cooling Speed (SH/H/HM/M/LM/L/SL) r/min 840/800/720/650/580/530/410 810/770/690/620/550/500/380 Heating Speed (SH/H/HM/M/LM/L/SL) r/min 930/840/760/690/620/570/480 850/800/720/650/580/530/470 Fan Motor Power Output W 30 Fan Motor RLA A 0.15 Fan Motor Capacitor μF / Evaporator Form Aluminum Fin-copper Tube Evaporator Pipe Diameter mm Φ7 Evaporator Row-fin Gap mm 2-1.3 Evaporator Coil Length (LXDXW) mm 511X400X25.4 Swing Motor Model MP24EB/MP24AE Swing Motor Power Output W 1.5/1.5 Fuse Current A 3.15 Sound Pressure Level (SS/H/MH/M/ML/L/SL) dB (A) 47/45/43/41/38/37/32 Indoor Unit Sound Power Level (SS/H/MH/M/ML/L/SL) dB (A) 57/55/53/51/48/47/42 Dimension (WXHXD) mm 700X600X215 Dimension of Carton Box (LXWXH) mm 785X280X682 Dimension of Package(LXWXH) mm 788X283X697 Net Weight kg 15.5 Gross Weight kg 18.5 5 Technical Information 2 23-34
Outdoor Unit Model GEH18AA-K6DNA1F/O Outdoor Unit Product Code CV010W02800 Compressor Manufacturer ZHUHAI LANDA COMPRESSOR CO.,LTD Compressor Model QXF-B141zF030A Compressor Oil 68DA Compressor Type Rotary Compressor LRA. A 25 Compressor RLA A 6.5 Compressor Power Input W 1410 Compressor Overload Protector 1NT11L-6233 or KSD115ºC or HPC115/95U1 Throttling Method Electron expansion valve Set Temperature Range ºC 16~30 Cooling Operation Ambient Temperature Range ºC -15~43 Heating Operation Ambient Temperature Range ºC -22~24 Condenser Form Aluminum Fin-copper Tube Condenser Pipe Diameter mm Φ7 Condenser Rows-fin Gap mm 2-1.4 Condenser Coil Length (LXDXW) mm 851X38.1X660 Fan Motor Speed rpm 800 Fan Motor Power Output W 60 Fan Motor RLA A 0.4 Fan Motor Capacitor μF / Outdoor Unit Air Flow Volume m Outdoor Unit 3/h 3200 Fan Type Axial-flow Fan Diameter mm Φ520 Defrosting Method Automatic Defrosting Climate Type T1 Isolation I Moisture Protection IPX4 Permissible Excessive Operating Pressure for the Discharge Side MPa 4.3 Permissible Excessive Operating Pressure for the Suction Side MPa 2.5 Sound Pressure Level (H/M/L) dB (A) 57/-/- Sound Power Level (H/M/L) dB (A) 65/-/- Dimension(WXHXD) mm 965X700X396 Dimension of Carton Box (LXWXH) mm 1026X455X735 Dimension of Package(LXWXH) mm 1029X458X750 Net Weight kg 46 Gross Weight kg 50.5 Refrigerant R32 Refrigerant Charge kg 0.95 Connection Pipe Length m 5 Connection Pipe Gas Additional Charge g/m 16 Outer Diameter Liquid Pipe mm Φ6 Outer Diameter Gas Pipe mm Φ12 Max Distance Height m 10 Max Distance Length m 25 Note: The connection pipe applies metric diameter. Connection Pipe The above data is subject to change without notice. Please refer to the nameplate of the unit. 6 Technical Information Service Manual
Service Manual 2.2 Operation Characteristic Curve Cooling Heating 11 11 220V 220V 10 • Conditions Indoor : DB27˚C/WB19˚C Outdoor : DB35˚C/WB24˚C Indoor air flow : High Pipe length : 5m 10 9 9 8 8 7 7 Current (A) Current (A) 230V 6 6 230V 5 5 240V 4 4 3 • Conditions Indoor : DB20˚C/WB15˚C Outdoor : DB7˚C/WB6˚C Indoor air flow : High Pipe length : 5m 3 240V 2 2 1 1 0 0 0 0 9 0 7 0 6 0 5 0 4 0 3 0 2 0 1 0 1 1 0 2 1 0 0 1 0 9 0 8 0 7 0 6 0 5 0 4 0 3 0 2 0 1 0 80 Compressor frequency(Hz) Compressor frequency(Hz) 2.3 Capacity Variation Ratio According to Temperature g nilo o C g nit a e H 140 140 120 Capacity ratio(%) 120 100 Capacity ratio(%) 100 80 80 Conditions Indoor:DB20°C Indoor air flow:Super High Pipe length:5m 60 60 Condition Indoor:DB27°C WB19°C Indoor air flow: High Pipe length:5m 40 40 20 20 0 0 -15 -10 -5 0 5 10 15 20 25 30 35 43 -22 -15 -10 -7 0 2 7 15 18 21 24 Outdoor temp.(°C) Outdoor temp.(°C) 7 Technical Information
2.4 Noise Curve Outdoor side noise when blowing Indoor side noise when blowing 52 50 12K 18K 51 40 50 Noise dB(A) 30 49 09K 48 20 47 SL L LM M HM H SH 46 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Indoor fan motor rotating speed Compressor frequency(Hz) 8 Technical Information Service Manual Cooling Heating
Service Manual 3. Outline Dimension Diagram 3.1 Indoor Unit 700 215 398 205 22 9 Technical Information 600 Unit:mm
3.2 Outdoor Unit GEH12AA-K6DNA1A/O 257 257 780 320 320 GEH09AA-K6DNA1F/O 257 540 320 Unit:mm Unit:mm 10 Technical Information Service Manual 596 848 286 Unit:mm 540 712 782 286 510
Service Manual GEH18AA-K6DNA1F/O 341 700 396 560 Unit:mm 11 Technical Information 892 965 368
4. Refrigerant System Diagram Indoor unit Outdoor unit Suction Heat exchanger (evaporator) Heat exchanger (condenser) Connection pipe specification: Liquid pipe:1/4" (6mm) Gas pipe:3/8" (9.52mm)(09/12K) Gas pipe:1/2" (16mm)(18K) 12 Technical Information Service Manual Gas pipe side Valve 4-Way valve Discharge Liquid pipe side Valve Strainer Electron expansion valve Strainer COOLING HEATING
Service Manual
5. Electrical Part
5.1 Wiring Diagram
● Instruction
Symbol
Symbol Color
Symbol
Symbol Color
Symbol
Name
WH
White
GN
Green
CAP
Jumper cap
YE
Yellow
BN
Brown
COMP
Compressor
RD
Red
BU
Blue
Grounding wire
YEGN
Yellow/Green
BK
Black
/
/
VT
Violet
OG
Orange
/
/
Note: Jumper cap is used to determine fan speed and the swing angle of horizontal lover for this model.
● Indoor Unit
GEH12AA-K6DNA1A/I(CV010N02900) GEH18AA-K6DNA1F/I(CV010N02800)
:$51,1*
3OHDVHGRQ
WWRXFKDQ\HOHFWURQLF
FRPSRQHQWRUWHUPLQDOZKHQWKH
PDFKLQHLVUXQQLQJVWRSSLQJRU
KDVEHHQSRZHUHGRIIIRUOHVV
WKDQPLQXWHVWRSUHYHQW
HOHFWULFVKRFN
6:,7&+
52207(03 78%(7(03
6(1625
6(1625
02725
5(&(,9(5$1'
0
)$1
6(/(&7
',63/$<%2$5'
$3
6
$3
',63/$<
57
57
/
0$*1(7,&
5,1*
02725)5$0(
5220
78%(
',63
',63
&1
'&02725
5,1*
0$*1(7,&
2*
&1
;7
/
%8
%8
287'22581,7
$335,17('&,5&8,7%2$5'
1
1
/
%.
%.
&$3
&20287
/
%1
%1
$&/
-803
<(*1
<(*1
<(*1
(
6:,1*'2:1
6:,1*83
:,),
&200$18$/
7(50,1$/
%/2&.
+($/7+/ +($/7+1
<(*1
%8
5'
3(
3(
(/(&75,&%2;
0
0
(9$325$725
%8
5'
$3
$3
*(1(5$725
&2/'3/$60$
02725
67(33,1*
02725
67(33,1*
:,),02'8/(
237,21$/
:,5('
&21752//(5
237,21$/
60000700126803
13
Technical InformationService Manual
GEH09AA-K6DNA1F/I(CV010N02701)
:$51,1*
3OHDVHGRQ
WWRXFKDQ\HOHFWURQLF
FRPSRQHQWRUWHUPLQDOZKHQWKH
PDFKLQHLVUXQQLQJVWRSSLQJRU
KDVEHHQSRZHUHGRIIIRUOHVV
WKDQPLQXWHVWRSUHYHQW
HOHFWULFVKRFN
52207(03 78%(7(03
5(&(,9(5$1'
',63/$<%2$5'
02725
)$1
6(1625
6(1625
0
$3
',63/$<
57
57
02725)5$0(
'&02725
5220
78%(
',63
',63
5,1*
0$*1(7,&
2*
&1
;7
/
%8
%8
287'22581,7
$335,17('&,5&8,7%2$5'
1
1
/
%.
%.
&$3
%1
&20287
/
%1
$&/
-803
<(*1
<(*1
<(*1
(
6:,1*'2:1
6:,1*83
&1
:,),
&200$18$/
7(50,1$/
%/2&.
<(*1
3(
(9$325$725
3(
(/(&75,&%2;
0
0
$3
6
$3
$3
6(/(&7
02725
67(33,1*
02725
67(33,1*
:,),02'8/(
:,5('
&21752//(5
237,21$/
6:,7&+
237,21$/
60000700126801
GEH12AA-K6DNA1A/I(CV010N02901) GEH18AA-K6DNA1F/I(CV010N02801)
:$51,1*
3OHDVHGRQ
WWRXFKDQ\HOHFWURQLF
FRPSRQHQWRUWHUPLQDOZKHQWKH
PDFKLQHLVUXQQLQJVWRSSLQJRU
KDVEHHQSRZHUHGRIIIRUOHVV
WKDQPLQXWHVWRSUHYHQW
HOHFWULFVKRFN
6:,7&+
52207(03 78%(7(03
6(1625
6(1625
5(&(,9(5$1'
0
)$1
02725
6(/(&7
',63/$<%2$5'
$3
6
$3
',63/$<
57
57
/
0$*1(7,&
5,1*
02725)5$0(
5220
78%(
',63
',63
&1
'&02725
5,1*
0$*1(7,&
2*
&1
;7
/
%8
%8
287'22581,7
$335,17('&,5&8,7%2$5'
1
1
/
%.
%.
&$3
&20287
/
%1
%1
$&/
-803
<(*1
<(*1
<(*1
(
6:,1*'2:1
6:,1*83
:,),
&200$18$/
7(50,1$/
%/2&.
<(*1
3(
3(
(/(&75,&%2;
0
0
(9$325$725
$3
$3
02725
67(33,1*
02725
67(33,1*
:,),02'8/(
237,21$/
:,5('
&21752//(5
237,21$/
60000700126804
14
Technical InformationService Manual
GEH09AA-K6DNA1F/I(CV010N02700)
:$51,1*
3OHDVHGRQ
WWRXFKDQ\HOHFWURQLF
FRPSRQHQWRUWHUPLQDOZKHQWKH
PDFKLQHLVUXQQLQJVWRSSLQJRU
KDVEHHQSRZHUHGRIIIRUOHVV
WKDQPLQXWHVWRSUHYHQW
HOHFWULFVKRFN
6:,7&+
)$1
02725
52207(03 78%(7(03
6(1625
6(1625
5(&(,9(5$1'
6(/(&7
',63/$<%2$5'
0
$3
6
$3
',63/$<
57
57
02725)5$0(
5220
78%(
',63
',63
&1
'&02725
5,1*
0$*1(7,&
2*
&1
;7
/
%8
%8
287'22581,7
$335,17('&,5&8,7%2$5'
1
1
/
%.
%.
&$3
&20287
/
%1
%1
$&/
-803
<(*1
<(*1
<(*1
(
6:,1*'2:1
6:,1*83
:,),
&200$18$/
7(50,1$/
%/2&.
+($/7+/ +($/7+1
<(*1
%8
5'
3(
3(
(/(&75,&%2;
0
0
(9$325$725
%8
5'
$3
$3
*(1(5$725
&2/'3/$60$
02725
67(33,1*
02725
67(33,1*
:,),02'8/(
237,21$/
:,5('
&21752//(5
600007001268
237,21$/
● Outdoor Unit
GEH09AA-K6DNA1F/O
:$51,1*
3OHDVHGRQ
WWRXFKDQ\
WHUPLQDOZKHQWKHPDFKLQHLV
UXQQLQJVWRSSLQJRUKDVEHHQ
SRZHUHGRIIIRUOHVVWKDQ
PLQXWHVWRSUHYHQWWKHULVN
RIHOHFWULFVKRFN
28778%( 2875220 (;+$867
:$<
(/(&7521,&
5($&725
7(03
6(1625
7(03
6(1625
7(03
9$/9(
(;3$16,21
/
%8
%1
6(1625
9$/9(
0$*1(7,&
5,1*
(.9
97
97
/
/
<9
57
57
57
N
N
N
/; /;
0$*1(7,&5,1*
;7
&1
&1
:$<
%8
/
/
%8
,1'22581,7
1
1
1
/
%.
%1
%.
$30DLQ%RDUG
/
$&/$&/
&208
/
%1
/
<(*1
3(
29&&203
+($7
2)$1
<(*1 <(*1
8 9 :
7(50,1$/
5'
5'
%8
%1%.
%/2&.
;
%8 <( 5'
/
1
0$*1(7,&
5,1*
3(
(+
3(
<(*1
<(*1
/
0
(/(&75,&$/
%2;
32:(5
%RWWRP
%DQG
+HDWHU
)$1
%8 <( 5'
6$7
:
8 9
3(
02725
&203
3527(&725
29(5/2$'
127(0RWRU
&203
JURXQGRQO\
DSSOLHVWRWKH
LURQVKHOOPRWRU
600007061371
15
Technical InformationService Manual
GEH18AA-K6DNA1F/O
7(036(1625
28778%(
7(036(1625
7(036(1625
(;+$867
:$51,1*
3OHDVHGRQ
WWRXFKDQ\
WHUPLQDOZKHQWKHYROWDJH
RIWHUPLQDO3'&DQG
1'&DW$3LVKLJKHU
WKDQ9WRSUHYHQWWKH
ULVNRIHOHFWULFVKRFN
29(5/2$'3527(&725
6$7
2875220
&203
:
9
8
:+
:+
&203
5,1*
/
/
0$*1(7,&
/
57
57
57
;
<(
%8
5'
.
.
.
<(*1
:+
%.
%/2&.
7(50,1$/
3(
<(
%8
5'
,1'22581,7
7B6(1625
8%8 9<( :5'
29&B&203
%1
%.
%8
1
/
%.
&20B,11(5
%8
$3
35,17('&,5&8,7%2$5'
%1
/
%1%.
%1
/
$&B/
/
%8
%8
1
1
:$<
)$
2)$1
+($7B%
0$*1(7,&
;7
3(
5,1*
<(*1
3(
5'
5'
<(*1
97
97
0
3(
32:(5
/
/
1
<(*1
(+
(.9
)$102725
3(
<9
:$<
%27720
(OHFWURQLF
RQO\DSSOLHVWRWKH
1RWH0RWRUJURXQG
9DOYH
3(
%$1'
+($7(5
([SDQVLRQ
9$/9(
LURQVKHOOPRWRU
600007061783
GEH12AA-K6DNA1A/O
:$51,1*
3OHDVHGRQ
WWRXFKDQ\
WHUPLQDOZKHQWKHPDFKLQHLV
UXQQLQJVWRSSLQJRUKDVEHHQ
SRZHUHGRIIIRUOHVVWKDQ
PLQXWHVWRSUHYHQWWKHULVN
RIHOHFWULFVKRFN
28778%( 2875220 (;+$867
(/(&7521,&
5($&725
7(03
6(1625
7(03
6(1625
7(03
9$/9(
(;3$16,21
:$<
/
%8
%1
6(1625
9$/9(
0$*1(7,&
5,1*
(.9
97
97
/
/
<9
57
57
57
N
N
N
/; /;
0$*1(7,&5,1*
;7
&1
:$<
&1
%8
/
%8
%.
%1
,1'22581,7
1
1
1
/
$30DLQ%RDUG
%.
%1
$&/$&/
&208
/
/
<(*1
+($7
2)$1
3(
29&&203
<(*1 <(*1
8 9 :
7(50,1$/
5'
5'
%8
%1%.
%/2&.
;
%8 <( 5'
/
1
0$*1(7,&
5,1*
(+
3(
3(
<(*1
<(*1
/
0
(/(&75,&$/
%2;
%RWWRP
%DQG
+HDWHU
%8 <( 5'
32:(5
6$7
:
8 9
)$1
02725
3(
&203
3527(&725
29(5/2$'
127(0RWRU
&203
JURXQGRQO\
DSSOLHVWRWKH
LURQVKHOOPRWRU
600007061430
These circuit diagrams are subject to change without notice, please refer to the one supplied with the unit.
16
Technical InformationService Manual 5.2 PCB Printed Diagram Indoor Unit ● Top view 8 9 10 11 12 13 14 13 Communication interface between indoor unit and outdoor unit 14 Control interface of Down swing 15 Wired controlled interface 16 Needle stand of jumper cap 17 Interface of display board 1 2 3 4 6 7 ● Bottom view 17 Technical Information NO. Name 1 Interface of tube temperature sensor 2 Interface of ambient temperature sensor 3 Up swing interface 4 Down swing interface 5 WIFI interface 6 Interface of EMC shielding wire 7 DC motor interface 8 Earthing wire of main board 9 Terminal of live wire 10 Fuse 17 16 11 Terminal for health function (only for the mode with this function) 12 Terminal of neutral wire 5 15
Outdoor Unit 09/12K ● Top view 3 2 1 ● Bottom view 18 Technical Information Service Manual 13 13 4 5 No. Name 1 Interface of compressor wire 2 Reactor wiring terminal 2 3 Reactor wiring terminal 1 4 Terminal of chassis electric heater 5 6 4-way valve terminal 7 Neutral wire Grounding wire 8 Communication wire 9 Live wire 10 Terminal of electronic expansion valve 11 Interface of temperature sensor 12 Overload interface of compressor 13 Terminal of outdoor fan 6 7 8 9 10 11 12
Service Manual GEH18AA-K6DNA1F/O ● Top view 1 2 10 3 5 4 8 7 9 6 ● Bottom view 19 Technical Information No Name Compressor wiring terminal for U V W 11 1 2 Terminal of system high pressure protection 3 Compressor overload protection terminal 4 Interface of temperature sensor 5 Terminal of electronic expansion valve Terminal of system low pressure protection 6 7 Terminal of outdoor fan 8 4-way valve terminal 12 9 Terminal of compressor electric heater 13 10 Terminal of compressor electric heater 11 Interface of electric heating belt of chassis 14 12 Terminal of power supply live wire terminal 13 Interface of communication wire for indoor unit and outdoor unit 14 Terminal of power supply earthing wire 15 Terminal of power supply neutral wire 15
6. Function and Control 6.1 Remote Controller Introduction Buttons on Remote Controller ON/OFF button 1 +/- button 2 MODE button 3 FAN button 4 SWING button 5 1 I FEEL button 6 2 / button 7 SLEEP button 8 4 3 TEMP button 9 5 6 QUIET button 10 8 7 ClOCK button 11 10 9 T-ON T-OFF button / 12 12 11 TURBO button 13 14 WiFi 13 WiFi button 15 14 LIGHT button 15 Introduction for Icons on Display Screen I feel Set fan speed Send signal Turbo mode Quiet Operation mode Healthy mode Scavenging functions Cool mode Auto mode 8 heating function Set temperature Dry mode X-FAN function Fan mode Heat mode Set time TIMER ON /TIMER OFF Clock Child lock Up & down swing Left & right swing Sleep mode Light Temp. display type :Set temp. :Indoor ambient temp. :Outdoor ambient temp. Introduction for Buttons on Remote Controller Note: This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model doesn't have, if press the corresponding button on the remote controller that the unit will keep the original running status. ON/OFF button 1 Press this button to turn on the unit. Press this button again to turn off the unit. 2 - button Press this button to decrease set temperature. Holding it down above 2 seconds rapidly decreases set temperature. In AUTO mode, set temperature is not adjustable. + button Press this button to increase set temperature. Holding it down above 2 seconds rapidly increases set temperature. In AUTO mode, set temperature is not adjustable. 20 Technical Information Service Manual
Service Manual MODE button 3 Each time you press this button , a mode is selected in a sequence that goes from AUTO,COOL, DRY, FAN, and HEAT * , as the following: *Note:Only for models with heating function. After energization, AUTO mode is defaulted. In AUTO mode, the set temperature will not be displayed on the LCD, and the unit will automatically select the suitable operation mode in accordance with the room temperature to make indoor room comfortable.(As for cooling only unit,it won’t have any action when it receives the signal of heating operation.) 4 FAN button This button is used for setting Fan Speed in the sequence that goes from AUTO, to then back to Auto. Auto Medium speed Low-Medium speed Low speed High speed Medium-High speed SWING button 5 Press this button to set up &down swing angle, which circularly changes as below: This remote controller is universal. If any command , or is sent out, the unit will carry out the command as indicates the guide louver swings as: I FEEL button 6 Press this button to turn on I FEEL function. The unit automatically adjust temperature according to the sensed temperature. Press this button again to cancel I FEEL function. / 7 button Press this button to achieve the on and off of healthy and scavenging functions in operation status. Press this button for the fi rst time to start scavenging function; LCD displays " ". Press the button for the second time to start healthy and scavenging functions simultaneously; LCD displays " " and " ". Press this button for the third time to quit healthy and scavenging functions simultaneously. Press the button for the fourth time to start healthy function; LCD display " ". Press this button again to repeat the operation above. SLEEP button 8 Press this button, can select Sleep 1 ( ), Sleep 2 ( ),Sleep 3 ( ) and cancel the Sleep,circulate between these, after electrifi ed, Sleep Cancel is defaulted. Sleep 1 is Sleep mode 1, in Cool mode: after run for one hour in sleep mode, the main unit setting temperature will increase 1 , after 2 hours, the setting temperature will increase 2 , but the maximal setting temperature is 30 , then the unit will run at this setting temperature all along; In Heat mode: after run for one hour in sleep mode, the setting temperature will decrease 1 after 2 hours the setting temperature will decrease 2 , but the minimal setting temperature is 16 , then the unit will run at this setting temperature all along. Sleep 2 is sleep mode 2, that is air conditioner will run according to the presetting a group of sleep temperature curve. Sleep 3- the sleep curve setting under Sleep mode by DIY: 21 Technical Information , , , ,
(1) Under Sleep 3 mode, press "Turbo" button for a long time, remote control enters into user individuation sleep setting status, at this
time, the time of remote control will display "1hour ",the setting temperature "88" will display the corresponding temperature of last
setting sleep curve and blink (The fi rst entering will display according to the initial curve setting value of original factory);
(2) Adjust "+" and "-" button, could change the corresponding setting temperature, after adjusted, press "Trubo "button for confi rmation;
(3) At this time, 1hour will be automatically increased at the timer postion on the remote control, (that are "2hours " or "3hours " or
"8hours "), the place of setting temperature "88" will display the corresponding temperature of last setting sleep curve and blink;
(4) Repeat the above step (2)
(3) operation, until 8hours temperature setting fi nished,sleep,curve setting fi nished, at this time, the
remote control will resume the original timer display;temperature display will resume to original setting temperature.
Sleep3- the sleep curve setting under Sleep mode by DIY could be inquired:
The user could accord to sleep curve setting method to inquire the presetting sleep curve,enter into user individuation sleep setting
status, but do not change the temperature, press "Turbo" button directly for confirmation.Note: In the above presetting or enquiry
procedure,if continuously within10s, there is no button pressed, the sleep curve setting within 10s, there is no button pressed, the sleep
curve setting status will be automatically quit and resume to display the original displaying. In the presetting or enquiry procedure, press
"ON/OFF" button, "Mode" button, "Timer"button or "Sleep" button, the sleep curve setting or enquiry status will quit similarly.
TEMP button
9
Press this button, you can see indoor set temperature, indoor ambient temperature on indoor unit’s display. The setting on remote
controller is selected circularly as below:
no display
When selecting " " with remote controller or no display, temperature indicator on indoor unit displays set temperature; When
selecting " " with remote controller, temperature indicator on indoor unit displays indoor ambie nt temperature; 5s later or within 5s
it receives other remote control signal that will return to display the setting temperature.
Caution:
This model hasn't outdoor ambient temperature display function. While remote controller
can operate " " and indoor unit displays set temperature.
It’s defaulted to display set temperature when turning on the unit.
Only for the models with temperature indicator on indoor unit.
QUIET button
10
Auto
Press this button, the Quiet status is under the Auto Quiet mode (display " "signal )and Quiet mode (display " " signal) and Quiet
OFF (there is no signal of " "displayed),after powered on, the Quiet OFF is defaulted. Note: the Quiet function cannot be set up in
Fan and Dry mode;Under the Quiet mode (Display" " Under the Quiet mode) the fan speed is not available.
11
ClOCK button
Press CLOCK button,blinking.
Within 5 seconds, pressing + or - button adjusts the present time. Holding down either button above
2 seconds increases or decreases the time by 1 minute every 0.5 second and then by 10 minutes every 0.5 second. During blinking
after setting, press CLOCK button again to confi rm the setting, and
then will be constantly displayed.
T-ON T-OFF button
12
/
Press T-ON button to initiate the auto-ON timer. To cancel the auto-timer program, simply press this button again.
After press of this button, disappears and "ON "blink s . 00:00 is displayed for ON time setting. Within 5 seconds, press + or - button
to adjust the time value. Every press of either button changes the time setting by 1 minute. Holding down either button rapidly changes
the time setting by 1 minute and then 10 minutes. Within 5 Seconds after setting, press TIMER ON button to confi rm.
Press T-OFF button to initiate the auto-off timer. To cancel the auto-timer program, simply press the button again.TIMER OFF setting is
the same as TIMER ON.
TURBO button
13
Press this button to activate / deactivate the Turbo function which enables the unit to reach the preset temperature in the shortest time.
In COOL mode, the unit will blow strong cooling air at super high fan speed. In HEAT mode, the unit will blow strong heating air at super
high fan speed.
22
Technical Information
Service ManualService Manual WiFi button 14 Press " WiF "i button to turn on or turn off WiFi function. When WiFi function is turned on, the " W i F i " icon will be displayed on remote controller; Under status of unit off, press "MODE" and "W i F i " " buttons simultaneously for 1s, WiFi module will restore to factory default setting. ● This function is only available for some models. 15 LIGHT button Press LIGHT button to turn on the display's light and press this button again to turn off the display 's light. If the light is turned on , is displayed. If the light is turned of f, disappears. If “H1” is displayed on the remote controller while it’s not operated by the professional person/after-sales person, it belongs to the misoperation. Please operate it as below to cancel it.Under the OFF status of remote controller, hold the Mode button for 5s to cancel “H1” display. Note: ● If remote controller displays “H1”, it belongs to the normal function reminder. If the unit is defrosting under heating mode, it operates according to H1 defrosting mode. “H1” won’t be displayed on the panel of indoor unit; ● Once you set H1 mode, if you turn off unit by remote controller, H1 will display 3 times on the remote controller and then disappear; ● Also, when you set H1 mode, when you change to heating mode, H1 will display 3 times on the remote controller and then disappear. Combination of "+" and "-" buttons: About lock Press "+" and "-" buttons simultaneously to lock or unlock the keypad. If the remote controller is locked, is displayed. In this case, pressing any button, blinks three times. Combination of "MODE" and "-" buttons:About switch between Fahrenheit and centigrade At unit OFF, press "MODE" and "-" buttons simultaneously to switch between °C and °F. Combination of "TEMP" and "CLOCK" buttons:About Energy-saving Function Press "TEMP" and "CLOCK" simultaneously in COOL mode to start energy-saving function.Nixie tube on the remote controller displays "SE". Repeat the operation to quit the function. Combination of "TEMP" and "CLOCK" buttons:About 8°C Heating Function Press "TEMP" and "CLOCK" simultaneously in HEAT mode to start 8°C Heating Function Nixie tube on the remote controller displays " " and a selected temperature of "8°C".(46°F if Fahrenheit is adopted). Repeat the operation to quit the function. About Back-lighting Function The unit lights for 4s when energizing for the fi rst time, and 3s for later press. Replacement of Batteries in Remote Controller 1.Press the back side of remote controller marked with“ ”as shown in the fi g, and then push out the cover of battery box along the arrow direction. 2. Replace two 7# (AAA 1.5V) dry batteries, and make sure the position of “+” polar and “-“ polar are correct. 3. Reinstall the cover of battery box. Note: ● During operation, point the remote control signal sender at the receiving window on indoor unit. ● The distance between signal sender and receiving window should be no more than 8m, and there should be no obstacles between them. ● Signal may be interfered easily in the room where there is fluorescent lamp or wireless telephone; remote controller should be close to indoor unit during operation. ● Replace new batteries of the same model when replacement is required. ● When you don’t use remote controller for a long time, please take out the batteries. ● If the display on remote controller is fuzzy or there’s no display, please replace batteries. 23 Technical Information battery reinstall remove Cover of battery box
6.2 GREE+ App Operation Manual Control Flow Chart Home Wi-Fi Gree intelligent home appliances Home wireless router Operating Systems Requirement for User's smart phone: iOS system Support iOS7.0 and above version Download and installation GREE+ App Download Linkage Scan the QR code or search "GREE+" in the application market to download and install it. When "GREE+" App is installed, register the account and add the device to achieve long-distance control and LAN control of Gree smart home appliances. For more information, please refer to "Help" in App. 24 Technical Information Service Manual Internet Gree Cloud Cellular/ Other Wi-FI Home Wi-Fi GREE+ APP Android system Support Android 4.4 and above version
Service Manual 6.3 Ewpe Smart App Operation Manual Control Flow Chart intelligent Home Wi-Fi home appliances Home wireless router Operating Systems Requirement for User's smart phone: iOS system Support iOS7.0 and above version Download and installation App Download Linkage Scan the QR code or search "Ewpe Smart" in the application market to download and install it. When "Ewpe Smart" App is installed, register the account and add the device to achieve long-distance control and LAN control of smart home appliances. For more information, please refer to "Help" in App. 25 Technical Information Internet Cloud Cellular/ Other Wi-FI Home Wi-Fi APP Android system Support Android 4.4 and above version
6.4 Brief Description of Modes and Functions 1. Cooling mode (1) Under this mode, the fan and the up swing will operate at setting status. The temperature setting range is 16~30ºC. (2) The unit is stopped because of malfunction of outdoor unit or protection. The indoor unit keeps original operation status and the error code is displayed. (3) Indoor unit is stopped due to mode shock. 2. Drying mode (1) Under this mode, the fan operates at low speed and the swing operates at setting status. The temperature setting range is 16~30ºC. (2) The unit is stopped because of malfunction of outdoor unit or protection. The indoor unit keeps original operation status and the error code is displayed. 3. Heating mode (1) Under this mode, the temperature setting range is 16~30ºC. (2) Working condition and process for heating When the unit is turned on under heating mode, the indoor unit turns to cold air prevention status. When the unit is turned off and the indoor unit has been started up before, the indoor unit blows the residual heat. (3) Protection function: When the compressor is stopped due to malfunction under heating mode, the indoor unit blows the residual heat. (4) Blow residual heat When the unit stops operation as it reaches the temperature point, indoor unit will continue to run for 60s. The fan speed cant be switched during blowing residual heat period. The upper horizontal louver will turn to the defaulted position in cooling. When the unit operates under heating mode or auto heating mode, compressor will be turned on and the corresponding electric expansion valve is more than 65 and the unit stops operation during the operation status of indoor unit. The upper horizontal louver will turn to the defaulted position in heating mode. The indoor unit operates at low speed for 10s and then the unit stops operation. (5) Defrosting, oil-returning As it received the signal of defrosting and oil-returning from outdoor unit, the upper horizontal louver will turn to the minimum angle in cooling. 10s later, the in door fan stop operation. During defrosting and oil-returning process and they are quitted within 5mins, all malfunctions for indoor tube temperature sensor wont be detected. 4. Working process for AUTO mode (Mode judgment will be performed every 30s) Under AUTO mode, standard cooling Tpreset=25ºC (77ºF), standard heating Tpreset=20ºC (68ºF), and standard fan Tpreset= 25ºC (77ºF). (1) When Tamb≥26ºC (79ºF), the unit operation in cooling mode; (2) Heating pump unit: When Tamb≤19ºC (66ºF), the unit operates in heating mode; (3) Cooling only unit: Tamb≤19ºC (66ºF), the unit operates in fanmode; (4) When 19ºC<Tindoor amb.<26ºC, if it turns to auto mode as the unit is turned on for the first time the unit will operates at auto fan mode. If it switch to auto mode from other modes, the unit will keep previous operation mode (when it turns to dry mode, the unit operates at auto fan mode). (5) Protection function Protection function is the same as that in cooling or heating mode. 5. Fan mode Under fan mode, only indoor fan and swing operates. When it operates at auto fan speed, it will operate according to auto fan speed condition in cooling. 6. Mode shock If the mode shock is 1 which is received by indoor unit from outdoor unit, the loads of indoor unit (indoor unit, auxiliary heating,swing) stop operation and the error code is displayed. The mode sent to outdoor unit is still remote control receiving mode. The unit will be turned off during mode shock. If timer ON is reached, and the mode shock is 1 which is received by indoor unit from outdoor unit, the loads of indoor unit (indoor unit,auxiliary heating, swing) stop operation and the error code is displayed. The mode sent to outdoor unit is still remote control receiving mode. 7. Other control 7.1 Buzzer Upon energization or availably operating the unit or remote controller, the buzzer will give out a beep. 7.2 Auto button If this button is pressed, the unit will operate in AUTO mode and indoor fan will operate at auto speed; meanwhile, the swing motor operates. Press this button again to turn off the unit. 7.3 8 ºC heating function Under heating mode, press TEMP+CLOCK buttons simultaneously. Under this mode, “cold air prevention protection” will be shielded. 26 Technical Information Service Manual
Service Manual 7.4 I FEEL function When I FEEL command is received, the controller will operate according to the ambient temperature sent by the remote controller (For defrosting and cold blow prevention, the unit operates according to the ambient temperature sensed by the air conditioner). The remote controller will send ambient temperature data to the controller every 10min. When the data has not been received after 11mins,the unit will operate according to the temperature sensed by the air conditioner. If I FEEL function is not selected, the ambient temperature will be that sensed by the air conditioner. I FEEL function will not to be memorized. 7.5 Timer function General timer and clock timer functions are compatible by equipping remote controller with different functions. (1)General Timer Timer ON can be set at unit OFF. If selected ON time is reached, the unit will start to operate according to previous setting status. Time setting range is 0.5-24hr in 30-minute increments. Timer OFF can be set at unit ON. If selected OFF time is reached, the unit will stop operation. Time setting range is 0.5-24hr in 30-minute increments. (2)Clock Timer Timer ON If timer ON is set during operation of the unit, the unit will continue to operate. If timer ON is set at unit OFF, upon ON time reaches the unit will start to operate according to previous setting status. Timer OFF If timer OFF is set at unit OFF, the system will keep standby status. If timer OFF is set at unit ON, upon OFF time reaches the unit will stop operation. Timer Change Although timer has been set, the unit still can be turned on/off by pressing ON/OFF button of remote controller. You can also set the timer once again, and then the unit will operate according to the last setting. If timer ON and timer OFF are set at the same time during operation of the unit, the unit will keep operating at current status till OFF time reaches. If timer ON and timer OFF are set at the same time at unit OFF, the unit will keep stop till ON time reaches. In the future’s every day, the system will operate according to presetting mode till OFF. 7.6 Sleep function This mode is only valid in cooling and heating modes. The unit will select proper sleep curve to operate according to different set temperature. 7.7 Compulsory defrosting function When the unit is turned on in heating by remote controller and the set temperature is 16 oC, press “+,-,+,-,+,-”continuously within 5s, the indoor unit turns to compulsory defrosting setting and it will send compulsory defrosting mode to outdoor unit. When indoor unit received the compulsory defrosting signal from outdoor unit, the indoor unit will quit from the compulsory defrosting setting and it will cancel to send compulsory defrosting mode to outdoor unit. 7.8 Refrigerant recovery function Turn to Freon recovery mode: After the unit is energized for 5min, and the unit is turned on at 16ºC under cooling mode, press light button on remote controller for 3 times successively within 3s to turn to Freon recovery mode. Fo is displayed and it will send Freon recovery mode to outdoor unit. Quit from Freon recovery mode:After it turns to Freon mode, if it receives any signal from remote controller or it turns to Freon recovery mode for 25 mins, it will quit from Freon recovery mode. Turn to the action for Freon recovery mode: indoor unit will be turned on in cooling mode. The fan speed is super-high fan speed and the set temperature is 16 oC. The horizontal louver will turn to the minimum operation angle. Quit the action for Freon recovery mode: The indoor fan operates at the previous set status by remote controller. 7.9 Pilot run function When the set temperature is 30 oC under cooling mode, press “+,-,+,-,+,-”continuously within 5s, the indoor unit turns to pilot run setting mode and it will send pilot run mode to outdoor unit. Pilot run mode: it operates under cooling mode and “dd” is displayed. Quit the pilot run mode and indoor unit cancels “dd” display. If it receives “wrong wire connection of malfunction of expansion valve” from outdoor unit, “dn” will be displayed. 27 Technical Information
Part Ⅱ: Installation and Maintenance 7. Notes for Installation and Maintenance Safety Precautions: Important! 10. If the power cord or connection wire is not long enough, please get the specialized power cord or connection wire from the manufacture or distributor. Prohibit prolong the wire by yourself. 11. For the air conditioner without plug, an air switch must be installed in the circuit. The air switch should be all-pole parting and the contact parting distance should be more than 3mm. 12. Make sure all wires and pipes are connected properly and the valves are opened before energizing. 13. Check if there is electric leakage on the unit body. If yes, please eliminate the electric leakage. 14. Replace the fuse with a new one of the same specification if it is burnt down; dont replace it with a cooper wire or conducting wire. 15. If the unit is to be installed in a humid place, the circuit breaker must be installed. Please read the safety precautions carefully before instal lation and maintenance. The following contents are very important for installation and maintenance. Please follow the instructions below. ●The installation or maintenance must accord with the instructions. ●Comply with all national electrical codes and local electrical codes. ●Pay attention to the warnings and cautions in this manual. ●All installation and maintenance shall be performed by distributor or qualified person. ●All electric work must be performed by a licensed technician according to local regulations and the instructions given in this manual. ●Be caution during installation and maintenance. Prohibit incorrect operation to prevent electric shock, casualty and other accidents. Installation Safety Precautions: 1. Select the installation location according to the require ment of this manual.(See the requirements in installation part) 2. Handle unit transportation with care; the unit should not be carried by only one person if it is more than 20kg. 3. When installing the indoor unit and outdoor unit, a suffi cient fixing bolt must be installed; make sure the installation support is firm. 4. Ware safety belt if the height of working is above 2m. 5. Use equipped components or appointed components dur ing installation. 6. Make sure no foreign objects are left in the unit after fin ishing installation. Warnings Electrical Safety Precautions: 1. Cut off the power supply of air conditioner before checking and maintenance. 2. The air condition must apply specialized circuit and prohibit share the same circuit with other appliances. 3. The air conditioner should be installed in suitable location and ensure the power plug is touchable. 4. Make sure each wiring terminal is connected firmly during installation and maintenance. 5. Have the unit adequately grounded. The grounding wire cant be used for other purposes. 6. Must apply protective accessories such as protective boards, cable-cross loop and wire clip. 7. The live wire, neutral wire and grounding wire of power supply must be corresponding to the live wire, neutral wire and grounding wire of the air conditioner. 8. The power cord and power connection wires cant be pressed by hard objects. 9. If power cord or connection wire is broken, it must be replaced by a qualified person. Improper installation may lead to fire hazard, explosion, electric shock or injury. 28 Installation and Maintenance Service Manual
Service Manual Safety Precautions for Installing and Relocating the Unit: To ensure safety, please be mindful of the following precautions. Warnings 1. When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the specified refrigerant. Any presence of air or other foreign substance in the refrigerant circuit will cause system pressure rise or compressor rupture, resulting in injury. 2.When installing or moving this unit, do not charge the refrigerant which is not comply with that on the nameplate or unqualified refrigerant. Otherwise, it may cause abnormal operation, wrong action, mechanical malfunction or even series safety accident. 3.When refrigerant needs to be recovered during relocating or repairing the unit, be sure that the unit is running in cooling mode.Then, fully close the valve at high pressure side (liquid valve).About 30-40 seconds later, fully close the valve at low pressure side (gas valve), immediately stop the unit and disconnect power. Please note that the time for refrigerant recovery should not exceed 1 minute. If refrigerant recovery takes too much time, air may be sucked in and cause pressure rise or compressor rupture, resulting in injury. 4.During refrigerant recovery, make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe. If compressor starts running when stop valve is open and connection pipe is not yet connected, air will be sucked in and cause pressure rise or compressor rupture, resulting in injury. 5.When installing the unit, make sure that connection pipe is securely connected before the compressor starts running. If compressor starts running when stop valve is open and connection pipe is not yet connected, air will be sucked in and cause pressure rise or compressor rupture, resulting in injury. 6.Prohibit installing the unit at the place where there may be leaked corrosive gas or flammable gas. If there leaked gas around the unit, it may cause explosion and other accidents. 7.Do not use extension cords for electrical connections. If the electric wire is not long enough, please contact a local service center authorized and ask for a proper electric wire. Poor connections may lead to electric shock or fire. 8.Use the specified types of wires for electrical connections between the indoor and outdoor units. Firmly clamp the wires so that their terminals receive no external stresses. Electric wires with insufficient capacity, wrong wire connections and insecure wire terminals may cause electric shock or fire. Safety Precautions for Refrigerant ●To realize the function of the air conditioner unit, a special refrigerant circulates in the system. The used refrigerant is the fluoride R32,which is specially cleaned. The refrigerant is flammable and inodorous. Furthermore, it can leads to explosion under certain conditions. But the flammability of the refrigerant is very low. It can be ignited only by fire. ●Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm to the ozonosphere. The influence upon the greenhouse effect is also lower. R32 has got very good thermodynamic features which lead to a really high energy efficiency. The units therefore need a less filling. WARNING: ●Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture. Should repair be necessary,contact your nearest authorized Service Centre. Any repairs carried out by unqualified personnel may be dangerous. The appliance shall be stored in a room without continuously operating ignition sources. (for example:open flames , an operating gas appliance or an operating electric heater.) ●Do not pierce or burn. ●Appliance shall be installed, operated and stored in a room with a floor area larger than “X”m 2 (see table a).(only applies to appliances that are not fixed appliances). ●Appliance filled with flammable gas R32. For repairs, strictly follow manufacturer’s instructions only.Be aware that refrigrants not contain odour. ●Read specialists manual. 29 Installation and Maintenance
Safety Operation of Flammable Refrigerant Qualification requirement for installation and maintenance man ●All the work men who are engaging in the refrigeration system should bear the valid certification awarded by the authoritative organization and the qualification for dealing with the refrigeration system recognized by this industry. If it needs other technician to maintain and repair the appliance, they should be supervised by the person who bears the qualification for using the flammable refrigerant. ●It can only be repaired by the method suggested by the equipments manufacturer. Installation notes ●The air conditioner is not allowed to use in a room that has running fire (such as fire source,working coal gas ware, operating heater). ●It is not allowed to drill hole or burn the connection pipe. ●The air conditioner must be installed in a room that is larger than the minimum room area. The minimum room area is shown on the nameplate or following table a. ●Leak test is a must after installation. table a - Minimum room area(m 2) Charge amount (kg) ≤1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 2.1 2.2 2.3 2.4 2.5 floor location 4 14.5 16.8 19.3 22 24.8 27.8 31 34.3 37.8 41.5 45.4 49.4 53.6 Minimum room 4 window mounted 5.2 6.1 7 7.9 8.9 10 11.2 12.4 13.6 15 16.3 17.8 19.3 2 area( m ) 4 4 4 4 4 4 4 4 wall mounted 4 4.2 4.6 5 5.5 6 4 4 4 4 4 4 4 4 4 4 4 4 4 4 ceiling mounted Maintenance notes ●Check whether the maintenance area or the room area meet the requirement of the nameplate. — Its only allowed to be operated in the rooms that meet the requirement of the nameplate. ●Check whether the maintenance area is well-ventilated. — The continuous ventilation status should be kept during the operation process. ●Check whether there is fire source or potential fire source in the maintenance area. — The naked flame is prohibited in the maintenance area; and the “no smoking” warning board should be hanged. ●Check whether the appliance mark is in good condition. — Replace the vague or damaged warning mark. Welding ●If you should cut or weld the refrigerant system pipes in the process of maintaining, please follow the steps as below: a. Shut down the unit and cut power supply b. Eliminate the refrigerant c. Vacuuming d. Clean it with N2 gas e. Cutting or welding f. Carry back to the service spot for welding ●Make sure that there isnt any naked flame near the outlet of the vacuum pump and its well-ventilated. ●The refrigerant should be recycled into the specialized storage tank. Filling the refrigerant ●Use the refrigerant filling appliances specialized for R32. Make sure that different kinds of refrigerant wont contaminate with each other. ●The refrigerant tank should be kept upright at the time of filling refrigerant. ●Stick the label on the system after filling is finished (or havent finished). ●Dont overfilling. ●After filling is finished, please do the leakage detection before test running; another time of leak detection should be done when its removed. Safety instructions for transportation and storage ●Please use the flammable gas detector to check before unload and open the container. ●No fire source and smoking. ●According to the local rules and laws. 30 Installation and Maintenance Service Manual
Service Manual Main Tools for Installation and Maintenance 1. Level meter, measuring tape 4. Electroprobe 7. Electronic leakage detector 10. Pipe pliers, pipe cutter 31 Installation and Maintenance 2. Screw driver 3. Impact drill, drill head, electric drill 5. Universal meter 6. Torque wrench, open-end wrench, inner hexagon spanner 8. Vacuum pump 9. Pressure meter 11. Pipe expander, pipe bender 12. Soldering appliance, refrigerant container
Service Manual 8. Installation 8.1 Requirements for Electric Connection 1. Safety Precaution (1) Must follow the electric safety regulations when installing the unit. (2) If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to (avoid a hazard. (3) According to the local safety regulations, use qualified power supply circuit and air switch. (4) A air switch having a contact separation of at least 3mm in all poles should be fixed in fixed wiring. (5) The appliance shall be installed in accordance with national wiring regulation. (6) The air switch must have the functions of magnetic tripping and heat tripping in order to prevent short circuit or overload. Please install the air switch with suitable capacity according to the sheet below. (7) Make sure the power supply matches with the requirement of air conditioner.Unstable power supply or incorrect wiring may result in electric shock, fire hazard or malfunction. Please install proper power supply cables before using the air conditioner. (8) Properly connect the live wire, neutral wire and grounding wire of power socket. (9) Be sure to cut off the power supply before proceeding any work related to electric safety. (10) Do not put through the power before finishing installation. 2. Grounding Requirement (1) The air conditioner is first class electric appliance. It must be properly grounded with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock. (2) The yellow-green wire in air conditioner is grounding wire, which can't be used for other purposes. (3) The grounding resistance should comply with national electric safety regulations. 8.2 Installation of indoor unit 1. Selection of Installation Location (1) Such a place where cool air can be distributed throughout the room. (2) Such a place where condensation water is easily drained out. (3) Such a place that can handle the weight of indoor unit. (4) Such a place which has easy access for maintenance. (5) The appliance shall not be installed in the laundry. There are 2 styles of installation ● Ceiling type ● Floor type Each type is similar to the other as follows: The indoor unit should be sited in a place where: (1) The restrictions on installation specified in the indoor unit installation drawings are met. (2) Both air intake and exhaust have clear paths met. (3) The unit is not in the path of direct sunlight. (4) The unit is away from the source of heat or steam. (5) There is no source of machine oil vapour (this may shorten indoor unit life). (6) Cool(warm) air is circulated throughout the room. (7) The unit is away from electronic ignition type fluorwscent lamps (inverter or rapid stert type) as they may shorten the remote controller range. (8) The unit is at least 1 metre away from any television or radio set(unit may cause interference with the picture or sound). 32 Installation and Maintenance Air-Conditioner Air Switch Capacity 09K 10A 12/18K 16A Exposed Half conceated Concealed Mounting plate Molding Grid(field supply) Floor lnstallation Wall Installation Location for securing the installation panel. 700 200 120 220 644 120 220 570 600 170 30 160 Unit: mm 30
Service Manual Cautions for installation where air conditioner troubleis liable tooccur. Where there is toomuch of oil area. Where it is acid base area. Where there is irregular electrical supply. Schematic drawing of hooks: 2. Indoor Unit Installation Drawings The indoor unit may be mounted in any of the three styles shown here. Console unit shall be installed on the ground or the position where is 0.3m from the floor. 200mm 70mm or more Installtion paper plank 50mm or more 50mm or more 3. Refrigerant Piping (1) Drill a hole ( 65mm in diameter ) in the spot indicated by the symbol in the illustration ad below . (2) The location of the hole is different depending on which side of the pipe is taken out . (3) For piping ,see6.Connecting the refrigerant pipe , under Indoor Unit Installation. (4) Allow space around the pipe for a easier indoor unit pipe connection. Wall 45 45 60 g nipip m o tt o b t h gi R g nipip m o tt o b tf e L 75 75 45 75 75 Left back piping Right back piping Left/right piping 45 45 Unit: mm 33 Installation and Maintenance
Service Manual CAUTION Min.allowable length ●The suggested shortest pipe length is 2.5m,in order to avoid noise from the outdoor unit and vibration. (Mechanical noise and vibration may occur depending on how the unit is installed and the environment in which it is used.) ●See the installation manual for the outdoor unit for the maximum pipe length. ●For multi-connections ,see the installation manual for the multi-outdoor unit. wall 350 Refrigerant pipe 45 Unit: mm 75 Floor 4. Boring a Wall Hole and Installing Wall Embedded Pipe ● For walls containing metal frame or metal board ,be sure to use a wall embedded pipe and wall cover in the feed-through hole to ● Be sure to caulk the gaps around the pipes with caulking material to prevent water leakage. (1) Bore a feed-through hole of 55mm in the wall so it has a down slope toward the outside. (2) Insert a wall pipe into the hole. (3) Insert a wall cover into wall pipe . (4) After completing refrigerant piping, wiring, and drain piping, caulk pipe hole gap with putty. Inside Outside Caulking Wall embedded pipe (field supply) Φ55 mm Wall hole cover (field supply) Wall embedded pipe (field supply) 5. Drain Piping (1) Use commercial regid polyvinyl chloride pipe general VP 20 pipe, outer diameter 26mm, inner diameter 20mm for the drain pipe. (2)The drain hose (outer diameter 18mm at connecting end, 220mm long)is supplied with the indoor unit. Prepare the drain pipe picture below position. (3) The drain pipe should be inclined downward so that water will flow smoothly without any accumulation.(Should not be trap.) (4) Insert the drain hose to this depth so it wont be pulled out of the drain pipe. (5) Insulate the indoor drain pipe with 10mm or more of insulation material to prevent condensation. (6) Remove the air filters and pour some water into the drain pan to check the water flows smoothly. Must be no trap 150 Do not touch water 100 100 Drain hose 50 or more Vinyl chloride drain pipe Reducer Unit: mm 34 Installation and Maintenance
Service Manual 3 tabs 6. Installing Indoor Unit Preparation ●Open the front panel, remove the 4 screws and dismount the front grille while pulling it forward. ●Follow the arrows to disengage the clasps on the front case to remove it. ●Follow the procedure below when removing the slit portions. Casing Front grille Front panel Remove front grille ■For Moldings ●Remove the pillars. (Remove the slit portions on the bottom frame using nippers.) Open the front panel Remove 4 screws ■For Side Piping ●Remove the pillars. (1) Remove the 7screws. (2) Remove the upper casing (2 tabs). (3) Remove the left and right casings (2 tabs on eachside ). (4) Remove the slit portions on the bottom frame and casings using nippers . (5) Return by following the steps in reverse order(3>2>1). 2)Upper casing 3)Side casings 3)Side casings Remove the pillar Remove 7 screws Bottom frame Casing Casing Remove the pillar Remove the pillar Installation ●Secure using 6 screws for floor installations.(Do not forget to secure to the rear wall.) ●For wall installations, secure the mounting plate using 5 screws and the indoor unit using 4 screws.The mounting plate should be installed on a wall which can support the weight of the indoor unit. (1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring points on the wall. (2) Secure the mounting plate to the wall with screws. Floor Installation Wall Installation Casing 200mm Molding 6screws 6screws 35 Installation and Maintenance
Service Manual (3) Once refrigerant piping and drain piping connections are complete, fill in the gap of the through hole with putty. A gap can lead to condensation on the refrigerant pipe, and drain pipe, and the entry of insects into the pipes. (4) Attach the front panel and front grille in their original positions once all connections are complete. 7. Flaring the Pipe End (1) Cut the pipe end with a pipe cutter. (2) Remove burrs with the cut surface facing downward so that the chips do not enter the pipe. (3) Fit the flare nut on the pipe. (4) Flare the pipe. (5) Check that the flaring is properly made. CAUTION (1) DO not use mineral oil on flared part. (2) Prevent mineral oil from getting into the system as this would reduce the lifetime of the units. (3) Never use piping which had been used for previous installations. Only use parts which are delivered with the unit. (4) Do never install a drier to this R410A unit in order to guarantee its lifetime. (5) The drying material may dissolve and damage the system. (6) Incomplete flaring may cause refrigerant gas leakage. The pipe end must be evenly flared in a perfect circle Flare’s inner surface must be scratch-free Flaring Set exactly at the position shown below Conventional flare tool Flare tool for R32 A Clutch-type Clutch-type (Rigid-type) Wing-nut type (lmperial-type) Die Cut exactly at right angles Make sure that the flare nut is fitted Renove A 0-0.5mm 1.0-1.5mm 1.5-2.0mm burrs 8. Connecting the Refrigerant Pipe (1) Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leaks. Open-end wrench (fixed) Flare nut Coat here with refrigeration oil Wrench Connection pipe Indoor unit tubing (2) Align the centres of both flares and tighten the flares and tighten the flare nuts 3 or 4 turns by hand. Then tighten them fully with the torque wrenches. (3) To prevent gas leakage, apply refrigeration oil on both inner and outer surfaces in the flare. (Use refrigeration oil for R410A.) Flare nut tightening torque Gas side Liquid side 09/12K 18K 09/12K 3/8 inch 1/2 inch 1/4 inch 31-35 N.m 50-55 N.m 15-20 N.m Caution on Piping Handling (1) Protect the open end of the pipe against dust and moisture. (2) All pipe bends should be as gentle as possible. Use a pipe bender for bending. (Bending radius should be 30 to 40mm or larger.) Be sure to place a cap. If no flare cap is available,cover the flare mouth with tape to keep dirt or water out. 36 Installation and Maintenance
Service Manual Selection of Copper and Heat Insulation Materials When using commercial copper pipes and fittings, observe the following: (1) Insulation material: Polyethylene foam Heat transfer rate:0.041 to 0.052W/mK(0.035 to 0.045kca/(mh oC Refrigerant gas pipes surface temperature reaches 110 max. Choose heat insulation materials that will withstand this temperature. (2) Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below. Gas side Liquid side Gas pipe thermal insulation Liquid pipe thermal insulation 09/12K 18K 09/12K 18K O.D. 9.55mm O.D. 12.7mm O.D. 6.4mm I.D. 12-15mm I.D. 14-16mm I.D. 8-10mm Thickness 0.8mm Thickness 10mm Min. (3) Use separate thermal insulation pipes for gas and liquid refrigerant pipes. 9. Checking for Gas Leakage (1) Check for leakage of gas after air purging (2) See the sections on air purges and gas leak checks in the installation manual for the outdoor unit. 10. Attaching the Connection Pipe ●Attach the pipe after checking for gas leakage, described above. (1) Cut the insulated portion of the on-site piping, matching it up with the connecting portion. (2) Secure the slit on the refrigerant piping side with the butt joint on the auxiliary piping using the tape, making sure there are no gaps. (3) Wrap the slit and butt joint with the included insulation sheet, making sure there are no gaps. CAUTION (1) Insulate the joint of the pipes securely. Incomplete insulation may lead to water leakage. (2) Push the pipe inside so it does not place undue force on the front grille. 11. Connecting the Drain Hose Insert the supplied C drain hose into the socket of the drain pan. Fully insert the drain hose until it adheres to a seat of the socket. 12. Wiring With a Multi indoor unit, install as described in the installation manual supplied with the Multi outdoor unit. ●Live the sensor securing plate, remove the front metal plate cover, and connect the branch wiring to the terminal block. (1) Strip wire ends (15mm) (2) Mach wire colours with terminal numbers on indoor and outdoor units terminal blocks and firmly screw wires to the corresponding terminals. (3) Connect the earth wires to the corresponding terminals. (4) Pull wires to make sure that they are securely latches up, then retain wires with wire retainer. (5) In case of connecting to an adapter system, Run the remote controller cable and attach the S21. (Refer to 11. When connecting go an system.) 37 Installation and Maintenance Inter-unit wiring Gas pipe Liquid pipe Liquid pipe insulation Gas pipe insulstion Finising tape Check for leakage here Apply soapy water and ch- eck carefully for leaking gas. wipe soapy water off after the check is complete. Refrigerant pipe Refrigerant pipe Refrigerant pipe Slit Slit Insulation sheet Tape Auxiliary pipe Drain pan Seal Drain hose Drain pan Seal
Service Manual Sensor securing plate Firmly fix the wires with the terminal screws Outdoor unit 2 3 Terminal block Shape wires so N(1) that the front metal plate cover will fit securely. When wire length exceeds 10m, use 2.0mmdiameter wires Electrical component box Indoor unit Wire retainer Firmly secure wire retainer so that wires sustain no external stress. Front metal plate cover Use the specified wire type. Firmly fix the wires with the terminal screws CAUTION (1) Do not use tapped wires, stranded wires, extensioncords, or starburst connections, as they may cause overheating, electrical shock, or fire. (2) Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc, from the terminal block.) Doing so may cause electric shock or fire.) 8.3 Outdoor Unit Installation 4. Connect Indoor and Outdoor Pipes (1) Remove the screw on the right handle of outdoor unit and then remove the handle.(As show in Fig.D) (2) Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe.(As show in Fig.E) 1. Fix the Support of Outdoor Unit(Select it according to the actual installation situation) (1) Select installation location according to the house structure. (2) Fix the support of outdoor unit on the selected location with expansion screws. Liquid pipe Pipe joint Liquid valve gas pipe CAUTION (1) Take sufficient protective measures when installing the outdoor unit. (2) Make sure the support can withstand at least four times the unit weight. (3) The outdoor unit should be installed at least 3cm above the floor in order to install drain joint.(As show in Fig.A) (4) For the unit with cooling capacity of 2300W~5000W, 6 expansion screws are needed; for the unit with cooling capacity of 6000W~8000W, 8 expansion screws are needed; for the unit with cooling capacity of 10000W~16000W, 10 expansion screws are needed. Union nut gas valve Fig.E (3) Pretightening the union nut with hand. (4) Tighten the union nut with torque wrench . Refer to the following table for wrench moment of force: Hex nut diameter(mm) Tightening torque(N.m) Φ6 15~20 Φ9.52 30~40 Φ12 45~55 Φ16 60~65 Φ19 70~75 5. Connect Outdoor Electric Wire (1) Remove the wire clip; connect the power connection wire and signal control wire (only for cooling and heating unit) to the wiring terminal according to the color; fix them with screws.(As show in Fig.F) Drain vent Chassis Outdoor drain joint Drain hose At least 3cm above the floor Fig.B Fig.A 09、12K: 18K: 2. Install Drain Joint(Only for cooling and heating unit) (1) Connect the outdoor drain joint into the hole on the chassis. (2) Connect the drain hose into the drain vent.(As show in Fig.B) N(1) 2 3 N(1) 2 3 L N N L brown blue blue black yellow- green yellow- green brown (black) yellow- blue blue black yellow- green brown brown (black) L N green N L Indoor unit connection POWER Indoor unit connection POWER 3. Fix Outdoor Unit (1) Place the outdoor unit on the support. (2) Fix the foot holes of outdoor unit with bolts.(As show in Fig.C) Fig.F Note: the wiring board is for reference only, please refer to the actual one. Foot holes (2) Fix the power connection wire and signal control wire with wire clip (only for cooling and heating unit). screw Note: (1) After tightening the screw, pull the power cord slightly to check if it is firm. (2) Never cut the power connection wire to prolong or shorten the distance. Foot holes handle Fig.C Fig.D 38 Installation and Maintenance
Service Manual 8.4 Vacuum Pumping and Leak Detection 8.5 Check after Installation and Test Operation 1. Use Vacuum Pump (1) Remove the valve caps on the liquid valve and gas valve and the nut of refrigerant charging vent. (2) Connect the charging hose of piezometer to the refrigerant charging vent of gas valve and then connect the other charging hose to the vacuum pump. (3) Open the piezometer completely and operate for 10-15min to check if the pressure of piezometer remains in -0.1MPa. (4) Close the vacuum pump and maintain this status for 1-2min to check if the pressure of piezometer remains in -0.1MPa. If the pressure decreases, there may be leakage. (5) Remove the piezometer, open the valve core of liquid valve and gas valve completely with inner hexagon spanner. (6) Tighten the screw caps of valves and refrigerant charging vent. 1. Check after Installation Check according to the following requirement after finishing installation. NO. Items to be checked Possible malfunction 1 Has the unit been installed firmly? 2 Have you done the refrigerant leakage test? 3 Is heat insulation of pipeline sufficient? 4 Is water drained well? It may cause condensation and water dripping. Is the voltage of power supply according to the voltage marked on the nameplate? 5 Liquid valve Piezometer Lo Hi 6 Is electric wiring and pipeline installed correctly? Gas valve Valve cap Refrigerant charging vent 7 Is the unit grounded securely? It may cause electric leakage. Nut of refrigerant 8 Does the power cord follow the specification? Charging vent Vacuum pump 9 Is there any obstruction in air inlet and air outlet? Inner hexagon spanner The dust and sundries caused during installation are removed? 10 Open Close 11 The gas valve and liquid valve of connection pipe are open completely? 2. Leakage Detection (1) With leakage detector: Check if there is leakage with leakage detector. (2) With soap water: If leakage detector is not available, please use soap water for leakage detection. Apply soap water at the suspected position and keep the soap water for more than 3min. If there are air bubbles coming out of this position, theres a leakage. 12 Is the inlet and outlet of piping hole been covered? 2. Test Operation (1) Preparation of test operation ● The client approves the air conditioner installation. ● Specify the important notes for air conditioner to the client. (2) Method of test operation ● Put through the power, press ON/OFF button on the remote controller to start operation. ● Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check whether the operation is normal or not. ● If the ambient temperature is lower than 16℃, the air conditioner cant start cooling. 39 Installation and Maintenance The unit may drop, shake or emit noise. It may cause insufficient cooling (heating) capacity. It may cause condensation and water dripping. It may cause malfunction or damage the parts. It may cause malfunction or damage the parts. It may cause malfunction or damage the parts. It may cause insufficient cooling (heating) capacity. It may cause malfunction or damaging the parts. It may cause insufficient cooling (heating) capacity. It may cause insufficient cooling (heating) capacity or waster eletricity.
Service Manual 9. Maintenance 9.1 Error Code List Display Method of Indoor Unit No. Malfunction Name A/C status Possible Causes Dual-8 Code Display During cooling and drying operation, except indoor fan operates, all loads stop operation. During heating operation, the complete unit stops. High pressure protection of system 1 E1 2 Low pressure protection of system The Dual-8 Code Display will show E3 until the low pressure switch stop operation. E3 High discharge temperature protection of compressor During cooling and drying operation, compressor and outdoor fan stop while indoor fan operates. During heating operation, all loads stop. 3 E4 During cooling and drying operation, compressor and outdoor fan stop while indoor fan operates. During heating operation, all loads stop. 4 Overcurrent protection E5 During cooling operation, compressor stops while indoor fan motor operates. During heating operation, the complete unit stops. 5 Communi- cation Malfunction E6 During cooling operation: compressor will stop while indoor fan will operate. During heating operation, the complete unit stops. High temperature resistant protection 6 E8 During cooling and drying operation, compressor will stop while indoor fan will operate; During heating operation, the complete unit will stop 7 EEPROM malfunction EE Limit/ decrease frequency due to high temperature of module All loads operate normally, while operation frequency for compressor is decreased 8 EU 9 Malfunction protection of jumper cap Wireless remote receiver and button are effective, but can not dispose the related command C5 40 Installation and Maintenance Possible reasons: 1. Refrigerant was superabundant; 2. Poor heat exchange (including filth blockage of heat exchanger and bad radiating environment ); Ambient temperature is too high. 1.Low-pressure protection 2.Low-pressure protection of system 3.Low-pressure protection of compressor Please refer to the malfunction analysis (discharge protection, overload). 1. Supply voltage is unstable; 2. Supply voltage is too low and load is too high; 3. Evaporator is dirty. Refer to the corresponding malfunction analysis. Refer to the malfunction analysis (overload, high temperature resistant). Replace outdoor control panel AP1 Discharging after the complete unit is de-energized for 20mins, check whether the thermal grease on IPM Module of outdoor control panel AP1 is sufficient and whether the radiator is inserted tightly. If its no use, please replace control panel AP1. 1. No jumper cap insert on mainboard. 2. Incorrect insert of jumper cap. 3. Jumper cap damaged. 4. Abnormal detecting circuit of mainboard.
Service Manual Display Method of Indoor Unit No. Malfunction A/C status Possible Causes Dual-8 Name Code Display When the outdoor unit receive signal of Gathering refrigerant ,the system will be forced to run under cooling mode for gathering refrigerant 10 Gathering refrigerant Fo Indoor ambient temperature sensor is open/short circuited During cooling and drying operation, indoor unit operates while other loads will stop; during heating operation, the complete unit will stop operation. 11 F1 AC stops operation once reaches the setting Indoor evaporator temperature sensor is open/short circuited temperature. Cooling, drying: internal fan motor stops operation while other loads stop operation; heating: AC stop operation 12 F2 Outdoor ambient temperature sensor is open/short circuited During cooling and drying operating, compressor stops while indoor fan operates; During heating operation, the complete unit will stop operation 13 F3 Outdoor condenser temperature sensor is open/short circuited During cooling and drying operation, compressor stops while indoor fan will operate; During heating operation, the complete unit will stop operation. 14 F4 During cooling and drying operation, compressor will sop after operating for about 3 mins, while indoor fan will operate; During heating operation, the complete unit will stop after operating for about 3 mins. Outdoor discharge temperature sensor is open/short circuited 15 F5 Limit/ decrease frequency due to overload All loads operate normally, while operation frequency for compressor is decreased 16 F6 Decrease frequency due to overcurrent All loads operate normally, while operation frequency for compressor is decreased 17 F8 41 Installation and Maintenance Nominal cooling mode 1. Loosening or bad contact of indoor ambient temp. sensor and mainboard terminal. 2. Components in mainboard fell down leads short circuit. 3. Indoor ambient temp. sensor damaged.(check with sensor resistance value chart) 4. Mainboard damaged. 1. Loosening or bad contact of Indoor evaporator temp. sensor and mainboard terminal. 2. Components on the mainboard fall down leads short circuit. 3. Indoor evaporator temp. sensor damaged.(check temp. sensor value chart for testing) 4. Mainboard damaged. Outdoor temperature sensor hasnt been connected well or is damaged. Please check it by referring to the resistance table for temperature sensor) Outdoor temperature sensor hasnt been connected well or is damaged. Please check it by referring to the resistance table for temperature sensor) 1.Outdoor temperature sensor hasnt been connected well or is damaged. Please check it by referring to the resistance table for temperature sensor) 2.The head of temperature sensor hasnt been inserted into the copper tube Refer to the malfunction analysis (overload, high temperature resistant) The input supply voltage is too low; System pressure is too high and overload
Display Method of Indoor Unit No. Malfunction A/C status Possible Causes Dual-8 Name Code Display Decrease frequency Overload or temperature is too high; All loads operate normally, while operation frequency for 18 due to high air F9 Refrigerant is insufficient; Malfunction of electric expansion compressor is decreased discharge valve (EKV) Limit/ decrease frequency All loads operate normally, while operation frequency for Poor air-return in indoor unit or fan 19 FH speed is too low due to antifreezing compressor is decreased 1. Measure the voltage of position L and N on wiring board (XT), if the voltage is higher than 265VAC, turn on the unit after the supply voltage is increased to the normal range. 2.If the AC input is normal, measure the voltage of electrolytic capacitor C on control panel (AP1), if its normal, theres malfunction for the circuit, please replace the control panel (AP1) During cooling and drying operation, compressor will stop 20 Voltage for DC bus-bar while indoor fan will operate; During heating operation, the complete unit will stop operation. PH is too high 1. Measure the voltage of position L and N on wiring board (XT), if the voltage is higher than 150VAC, turn on the unit after the supply voltage is increased to the normal range. 2.If the AC input is normal, measure the voltage of electrolytic capacitor C on control panel (AP1), if its normal, theres malfunction for the circuit, please replace the control panel (AP1) During cooling and drying operation, compressor will stop while indoor fan will operate; During heating operation, the complete unit will stop 21 Voltage of DC bus-bar is too low PL Compressor Min frequence in test state P0 Showing during min. cooling or min. heating test 22 Compressor rated frequence in test state P1 Showing during nominal cooling or nominal heating test 23 Compressor maximum frequence in test state P2 Showing during max. cooling or 24 max. heating test 42 Installation and Maintenance Service Manual
Service Manual Display Method of Indoor Unit No. Malfunction Name A/C status Possible Causes Dual-8 Code Display Compressor intermediate frequence in P3 Showing during middle cooling or middle heating test 26 test state During cooling and drying Overcurrent operation, compressor will stop while indoor fan will operate; protection of phase 26 P5 During heating operation, the complete unit will stop current for compressor operation. During cooling and drying operation, compressor will stop Charging malfunction of capacitor PU 27 while indoor fan will operate; During heating operation, the complete unit will stop During cooling and drying operation, compressor will stop while indoor fan will operate; During heating operation, the complete unit will stop Malfunction of module temperature sensor circuit 28 P7 During cooling operation, compressor will stop while indoor fan will operate; During heating operation, the complete unit will stop 29 Module high temperature P8 protection During cooling and drying operation, compressor will stop while indoor fan will operate; During heating operation, the complete unit will stop operation. 30 Overload protection for compressor H3 During cooling and drying operation, compressor will stop 31 IPM protection H5 while indoor fan will operate; During heating operation, the complete unit will stop operation. Internal fan motor, external fan motor, compressor and electric heater stop operation,guide louver stops at present location. 32 Internal motor (fan motor) do H6 not operate 43 Installation and Maintenance Refer to the malfunction analysis (IPM protection, loss of synchronism protection and overcurrent protection of phase current for compressor. Refer to the part three—charging malfunction analysis of capacitor Replace outdoor control panel AP1 After the complete unit is de- energized for 20mins, check whether the thermal grease on IPM Module of outdoor control panel AP1 is sufficient and whether the radiator is inserted tightly. If its no use, please replace control panel AP1. 1. Wiring terminal OVC-COMP is loosened. In normal state, the resistance for this terminal should be less than 1ohm. 2.Refer to the malfunction analysis ( discharge protection, overload) Refer to the malfunction analysis (IPM protection, loss of synchronism protection and overcurrent protection of phase current for compressor. 1. Bad contact of DC motor feedback terminal. 2. Bad contact of DC motor control end. 3. Fan motor is stalling. 4. Motor malfunction. 5. Malfunction of mainboard rev detecting circuit.
Display Method of Indoor Unit No. Malfunction Name A/C status Possible Causes Dual-8 Code Display During cooling and drying operation, compressor will stop while indoor fan will operate; During heating operation, the complete unit will stop operation. Refer to the malfunction 33 Desynchro- nizing of analysis (IPM protection, loss of synchronism protection and H7 compressor overcurrent protection of phase current for compressor. During cooling and drying operation, compressor will stop while indoor fan will operate; During heating operation, the complete unit will stop operation. 34 PFC protection HC Replace outdoor control panel AP1 or Reactor 35 Outdoor DC fan motor DC fan motor malfunction or system blocked or the connector Outdoor DC fan motor malfunction lead to compressor stop operation, L3 malfunction loosed compressor stop operation and Outdoor fan motor will stop 30s latter , 3 minutes latter fan motor and compressor will restart To protect the electronical components when detect high power 36 power protection L9 Indoor unit and outdoor unit doesnt match LP compressor and Outdoor fan motor cant work Indoor unit and outdoor unit doesnt match 37 During cooling and drying operation, compressor will stop while indoor fan will operate; During heating operation, the complete unit will stop operation. 38 Failure start- up LC Refer to the malfunction analysis 39 Anti-freezing protection for evaporator E2 Not the error code. It’s the status code for the operation. 1. Outdoor ambient temperature exceeds the operation range of unit (eg: less than-20oC or more than Cool: compressor and outdoor fan stops operation, while indoor fan operates; Heat: 60oC for cooling; more than 30oC for heating); 2. Failure startup of compressor? 40 Undefined outdoor unit oE error compressor, outdoor fan and 3. Are wires of compressor not indoor fan stop operation. connected tightly? 4. Is compressor damaged? 5. Is main board damaged? Malfunction of During cooling and drying phase current detection circuit for operation, compressor will stop while indoor fan will operate; During heating operation, the 41 U1 Replace outdoor control panel AP1 compressor complete unit will stop During cooling and drying operation, compressor will stop Malfunction of voltage dropping for 42 U3 while indoor fan will operate; During heating operation, the Supply voltage is unstable DC bus-bar complete unit will stop 44 Installation and Maintenance Service Manual
Service Manual Display Method of Indoor Unit No. Malfunction Name A/C status Possible Causes Dual-8 Code Display During cooling and drying operation, the compressor will Malfunction of complete stop while indoor fan will operate; 43 U5 units current detection During heating operating, the complete unit will stop operation. If this malfunction occurs 44 The four-way valve is during heating operation, the complete unit will stop U7 abnormal operation. Cold air E9 Not the error code. It’s the status code for the operation. 45 prevention protection Heating indicator off for 0.5s and then blinks for 10s Not the error code. It’s the status code for the operation. 46 Defrosting 47 Refrigerant recovery mode Refrigerant recovery. The Serviceman operates it for maintenance. Fo Malfunction of zero-cross detection circuit 48 U8 The complete unit stops 49 Malfunction of detecting plate(WIFI ) Loads operate normally, while the unit can’t be normally controlled by APP. JF 45 Installation and Maintenance Theres circuit malfunction on outdoor units control panel AP1, please replace the outdoor units control panel AP1. 1.Supply voltage is lower than AC175V; 2.Wiring terminal 4V is loosened or broken; 3.4V is damaged, please replace 4V. 1.Power supply is abnormal; 2.Detection circuit of indoor control mainboard is abnormal. 1.Main board of indoor unit is damaged; 2.Detection board is damaged; 3.The connection between indoor unit and detection board is not good;
Analysis or processing of some of the malfunction display: 1. Compressor discharge protection Possible causes: shortage of refrigerant; blockage of air filter; poor ventilation or air flow short pass for condenser; the system has noncondensing gas (such as air, water etc.); blockage of capillary assy (including filter); leakage inside four-way valve causes incorrect operation; malfunction of compressor; malfunction of protection relay; malfunction of discharge sensor; outdoor temperature too high. Processing method: refer to the malfunction analysis in the above section. 2. Low voltage overcurrent protection Possi ble cause: Sudden drop of supply voltage. 3. Communication malfunction Processing method: Check if communication signal cable is connected reliably. 4. Sensor open or short circuit Processing method: Check whether sensor is normal, connected with the corre sponding position on the controller and if damage of lead wire is found. 5. Compressor over load protection Possible causes: insufficient or too much refrigrant; blockage of capillary and increase of suction temp.; improper running of compressor, burning in or stuck of bearing, damage of discharge valve; malfunction of protector. Processing method: adjust refrigerant amount; replace the capillary; replace the compressor; use universal meter to check if the contactor of compress or is fine when it is not overheated, if not replace the protector. 6. System malfunction ieoverload protection.When tube temperature(Check the temperature of outdoor heat exchanger when cooling and check the temperatur e of indoor heat exchanger when heating) is too high, protectionwill beactivated. Possi ble causes: Outdoor temperature is too high when cooling; insufficient outdoor air circulation; refrigerant flow malfunction. please refer to the malfunction analysis in the previous section for handling method . 7. IPM module protection Processing method:Once the module malfunction happens,if it persists for a long time and can not be selfcanceled, cut off the power and turn off the unit,and then re-energize the unit again after about 10 min.After repeating the procedure for sever times, if the malfunction still exists,replace the module. 46 Installation and Maintenance Service Manual
Service Manual 9.2 Procedure of Troubleshooting Indoor unit 1. Malfunction of Temperature Sensor Main detection points: ● Is the wiring terminal between the temperature sensor and the controller loosened or poorly contacted? ● Is there short circuit due to trip-over of the parts? ● Is the temperature sensor broken? ● Is mainboard broken? Malfunction diagnosis process: 47 Installation and Maintenance Start Is the wiring terminal between the temperature sensor and the controller Yes loosened or poorly contacted? Insert the temperature sensor tightly No No Is malfunction eliminated Yes Is there short circuit due to trip- over of the parts Make the parts upright No No Is malfunction Yes eliminated Is the temperature sensor normal according to the resistance table? No Yes Replace it with a temperature sensor with the same model Yes Is malfunction No eliminated Replace the mainboard with the same model. Yes End
2. Malfunction of Blocked Protection of IDU Fan Motor Main detection points: ● SmoothlyIs the control terminal of PG motor connected tightly? ● SmoothlyIs the feedback interface of PG motor connected tightly? ● The fan motor cant operate? ● The motor is broken? ● Detectioncircuit of the mainboard is defined abnormal? Malfunction diagnosis process: Measure the voltage of this foot to neutral wire on the mainboard 48 Installation and Maintenance Service Manual Start While power is off stir the blade No with a tool to see whether the blade rotates smoothly Tighten the screw; reassemble the blade, motor and shaft bearing rubber base sub-assy to make sure there is no foreign object between them Yes No Is malfunction Yes eliminated Check if the connection of PG motor feedback terminal is firm No Insert the control terminal of PG motor tightly Yes No Is malfunction Yes eliminated Check if the connection of PG No motor control terminal is firm Reinstall the blade and motor correctly Yes No Is malfunction Yes eliminated Turn on the unit again; measure whether the output voltage on control terminal for PG motor is more than 50V within 1 min after Yes Yes the louvers are opened Yes Is the motor started up No Replace PG motor No No Yes Is malfunction eliminated Replace the mainboard with the same model End
Service Manual 3. Malfunction of Protection of Jumper Cap Main detection points: ● Is there jumper cap on the mainboard? ● Is the jumper cap inserted correctly and tightly? ● The jumper is broken? ● The motor is broken? ● Detection circuit of the mainboard is defined abnormal? Malfunction diagnosis process: Start No Appearance of the Is there jumper cap on the mainboard? jumper cap Assemble the jumper cap with the same model Yes No Is malfunction eliminated No Is the jumper cap inserted correctly and tightly? Insert the jumper cap tightly Yes No Is malfunction Yes eliminated Replace the jumper cap with the same model Yes Is malfunction eliminated Yes No Replace the mainboard with the same model End 49 Installation and Maintenance
4. Malfunction of Zero-crossing Inspection Circuit Malfunction of the IDU Fan Motor Main detection points: ● Instant energization afte de-energization while the capacitordischarges slowly? ● The zero-cross detectioncircuit of the mainboard is defined abnormal? Malfunction diagnosis process: Start Turn power off for 1minute,the turn back on The unit returns to normal. Conclusion:U8 is displayed due to power off/on while the capacitor discharges slowly. U8 is still displayed No Yes The zero-cross detection circuit of the mainboard is defined abnormal.Replace the mainboard with the same model End 50 Installation and Maintenance Service Manual
Service Manual 5. Malfunction of detecting plate(WIFI )JF Start check if the connection wire are correctly connected Yes Replace the detecting plate with the same model Replace the mainboard with the same model Yes 51 Installation and Maintenance Is malfunction eliminated No The end
Service Manual Outdoor unit 1. Capacitor charge fault (Fault with outdoor unit) (AP1 below refers to the outdoor control panel) Main Check Points: ●Use AC voltmeter to check if the voltage between terminal L and N on the wiring board is within 210VAC~240VAC. ●Is the reactor (L) correctly connected? Is the connection loose or fallen? Is the reactor (L) damaged? Fault diagnosis process: Turn on the unit and wait 1 minute Use DC voltmeter to measure the voltage on the two ends of electrolytic capacitor Fault with the voltage Yes Replace the control testing circuit on control panel AP1 Voltage higher than 200V? panel AP1 No Measure the AC voltage between terminal L and N on wiring board XT(power supply) Shut down the power and repair the power supply to restore the range 210VAC~250VAC power on and restart the unit Voltage within 210VAC~250VAC? If the fault is eliminated? No Yes Yes Shut down the power and wait 20 minutes; or use DC voltmeter to measure the voltage on the two ends of capacitor , until the voltage is lower than 20V No Check the connection of reactor (L in the Electrical Wiring Diagram) Connect the reactor Laccording to Elec- trical Wiring Diagr- am correctly Re-energize and turn on the unit If the wiring of reactor L is normal? No If the fault is eliminated? Yes Yes Replace the control panel AP1 No End 52 Installation and Maintenance
Service Manual
(2) IPM protection, phase current overcurrent (the control board as below indicates the control board
of outdoor unit) H5/P5
Mainly detect:
(1) Compressor COMP terminal (2) voltage of power supply (3) compressor
(4) Refrigerant-charging volume (5) air outlet and air inlet of outdoor/indoor unit
Troubleshooting:
Turn on the unit
after energization
Whether IPM
protection occurs after the unit has
operated for a while?
Correctly connect the wires of
compressor according to the
electric wiring diagram, and
then turn on the unit
Measure the voltage
between terminal L
and terminal N with
AC volmeter
Check the power
supply voltage and
make the power voltage
Whether
the voltage between
terminal L and terminal N of XT is
resume to the range
of 210VAC~250VAC
within 210AVC~
250VAC?
1. Whether the heat exchangers of indoor unit and outdoor unit are
dirty? Whether the radiation is affected because the unit is
covered by the objects?
2. When indoor fan and outdoor unit are operate normally?
3. Whether the system pressure is too high?
4. Whether the pressure is because there's too much refrigerant?
Correct it one by one
according to the Service
Manual, and then turn on
Whether there's
abnormal phenomenons
described as above?
the unit.
Whether the unit
can operate normally?
Replace control
board
End
53
Installation and Maintenance
Check the connection
between the control board
and the compressor by
referring to the electric
wiring diagram
Check whether wires
of compressor (UVW) are connected
correctly
Measure the resistance value
among three terminals (UVW)
of compressor with a resistance
measuring meter.
Whether the
resistance value of three terminals
are almost the same.
Measure the resistance
between three terminals (UVW)
of compressor and the copper pipe
with resistance measuring meter
Whether the
resistance value is more than
500ohm?
Replace the
compressor 3. High temperature and overload protection diagnosis (AP1 hereinafter refers to the control board of the outdoor unit) Mainly detect: ●Is outdoor ambient temperature in normal range? ●Are the outdoor and indoor fans operating normally? ●Is the heat dissipation environment inside and outside the unit good? Fault diagnosis process: Overheat and high temperature protection Normal protection, please operate it after the outdoor ambient temp- erature is normalized. Yes Is outdoor ambient temperature higher than 53? No 20 minutes after the complete unit is powered off. Improve the heat dissipation environ- ment of the unit Yes Is heat dissipation of the indoor unit and outdoor unit abnormal? No 1. Check if the fan terminal OFAN is connected correctly 2. Resistance between any two terminals is measure by an ohm gauge and should be less than 1K Ohm. No Does the outdoor fan work normally? Yes Replace the fan capacitor C1 Replace the control panel AP1 Replace the outdoor fan End 54 Installation and Maintenance Service Manual
Service Manual 4. Start-up failure (following AP1 for outdoor unit control board) Mainly detect: ●Whether the compressor wiring is connected correct? ●Is compressor broken? ●Is time for compressor stopping enough? Fault diagnosis process: 55 Installation and Maintenance Power on the unit No Restart it up after 3 minutes Is stop time of the compressor longer than 3 minutes? Yes Does startup fail? Yes Connect the wires as per the connection diagram Are the wires for the compressor connected No correctly? Is connection sequence right? Yes Replace the control panel AP1 No If the fault is eliminated? No Replace the compressor Yes End
5. Out of step diagnosis for the compressor (AP1 hereinafter refers to the control board of the outdoor unit) Mainly detect: ●Is the system pressure too high? ●Is the input voltage too low? Fault diagnosis process: Out of step occurs once the unit is powered on. No Is stop time of the compressor longer than 3 minutes? Yes Are the wires for the compressor connected correctly? Is connection sequence right? Is the connection made in clockwise direction? No Connect the wires correctly Yes Replace the control panel AP1 Yes If the fault is eliminated? No Replace the compressor End 56 Installation and Maintenance Service Manual Out of step occurs in operation Check if the fan terminal OFAN is connected correctly No Replace the fan Is the outdoor fan working normally? capacitor C1 Yes Replace the outdoor fan Is the outdoor unit blocked Yes Remove foreign objects by foreign objects? No Replace the control panel AP1 Yes If the fault is eliminated? No Replace the compressor End
Service Manual 6. Overload and air exhaust malfunction diagnosis (following AP1 for outdoor unit control board) Mainly detect: ●Is the PMV connected well or not? Is PMV damaged? ●Is refrigerant leaked? Fault diagnosis process: 57 Installation and Maintenance 20 minutes after the complete unit is powered off Is the terminal FA for the electronic expansion valve Connect the wires correctly No connected correctly? Yes Resistances between the first four pins close to the terminal hole and the fifth pin are almost the same, less than 100 ohm. Replace the electronic expansion valve Yes If the fault is eliminated? No Replace the control panel AP1 Yes If the fault is eliminated? No Coolant leakage, refilling the coolant End
Service Manual 7. Communication malfunction: (following AP1 for outdoor unit control board) Mainly detect: ●Is there any damage for the indoor unit mainboard communication circuit? Is communication circuit damaged? ●Detect the indoor and outdoor units connection wire and indoor and outdoor units inside wiring is connect well or not, if is there any damage? Fault diagnosis process: Start Did the equipment operate normally before the failure No Yes occurs? Check the wiring of the indoor and outdoor units with reference to the wiring diagram Check wiring inside of the indoor and outdoor Yes Is the connection right? units No No Correctly connect the corresponding wires for The AP1 voltage detection circuit is at fault Yes Are wires broken? the indoor and outdoor units with reference to the wiring diagram No Check the communication No circuit of the outdoor unit If the fault is eliminated? If the fault is eliminated? Replace the main board The communication Yes AP1 of the outdoor unit circuit is abnormal No If the fault is eliminated? No Replace the main board of the indoor unit Yes Yes Yes End 58 Installation and Maintenance
Service Manual 8. Malfunction of Overcurrent Protection Main detection points: ● Is the supply voltage unstable with big fluctuation? ● Is the supply voltage too low with overload? ● Hardware trouble? Malfunction diagnosis process: Start Yes Yes Normal fluctuation should be within 10 % of the rated voltage on the nameplate Is the supply voltage unstable with big fluctuation? No No Yes Is the supply voltage too low Adjust the supply voltage to maintain it within normal range with overload? No No Is the indoor / outdoor heat exchanger dirty,or are the air inlet Yes Clean the indoor and outdoor heat exchangers and remove the blockage of air inlet and outlet and outlet blocked? No No The fan is abnormal? Fan speed is too low or fan doesnt rotate Yes Check the motor and reinstall the motor to have the fan run normally No No Measure the current of live wire on the main board with a clamp ampere No Replace the mainboard with the same model meter. Is the current higher than the value of the overcurrent protection? No Yes Is there blockage inside the system? Yes Flush the heat exchangers with high pressure nitrogen (Filth blockage, ice plug, greasy blockage, the cut off valve hasnt been opened completely) No No Is the compressor running abnormally? Is there abnormal sound or oil leakage; Is the temperature of the shell too high, Yes Replace the compressor etc.? No Replace the mainboard with the same model End 59 Installation and Maintenance Is malfunction eliminated Yes Is malfunction eliminated Yes Is malfunction eliminated Is malfunction Yes eliminated Is malfunction Yes eliminated Yes Is malfunction eliminated Is malfunction Yes eliminated
9.3 Maintenance Method for Normal Malfunction 1. Air Conditioner Can't be Started Up Possible Causes Discriminating Method (Air conditioner Status) Troubleshooting Confirm whether it's due to power failure. If yes, wait for power recovery. If not, check power supply circuit and make sure the power plug is connected well. Wrong wire connection between indoor unit and outdoor unit, or poor connection for wiring terminals No power supply, or poor connection for power plug After energization, operation indicator isn’t bright and the buzzer can't give out sound Under normal power supply circumstances, operation indicator isn't bright after energization Make sure the air conditioner is grounded reliably Make sure wires of air conditioner is connected correctly Check the wiring inside air conditioner. Check whether the insulation layer of power cord is damaged; if yes, place the power cord. Model selection for air switch is improper After energization, air switch trips off Select proper air switch Electric leakage for air conditionerAfter energization, room circuit breaker trips off at once After energization, operation indicator is bright, while no display on remote controller or buttons have no action. Malfunction of remote controller 2. Poor Cooling (Heating) for Air Conditioner Possible Causes Discriminating Method (Air conditioner Status) Troubleshooting Set temperature is improper Observe the set temperature on remote controller Adjust the set temperature Rotation speed of the IDU fan motor is set too low Small wind blow Set the fan speed at high or medium Filter of indoor unit is blocked Check the filter to see it's blocked Clean the filter Check whether the installation postion is proper according to installation requirement for air conditioner Installation position for indoor unit and outdoor unit is improper Discharged air temperature during cooling is higher than normal discharged wind temperature; Discharged air temperature during heating is lower than normal discharged wind temperature; Unit's pressure is much lower than regulated range Refrigerant is leaking Malfunction of 4-way valve Blow cold wind during heating Replace the 4-way valve Discharged air temperature during cooling is higher than normal discharged wind temperature; Discharged air temperature during heating is lower than normal discharged wind temperature; Unit't pressure is much lower than regulated range. If refrigerant isn’t leaking, part of capillary is blocked Malfunction of capillary Flow volume of valve is insufficient The pressure of valves is much lower than that stated in the specification Open the valve completely Malfunction of horizontal louver Horizontal louver can’t swing Refer to point 3 of maintenance method for details Malfunction of the IDU fan motor The IDU fan motor can’t operate Refer to troubleshooting for H6 for maintenance method in details Malfunction of the ODU fan motor The ODU fan motor can't operate Refer to point 4 of maintenance method for details Malfunction of compressor Compressor can't operate Refer to point 5 of maintenance method for details 3. Horizontal Louver Can't Swing Possible Causes Discriminating Method (Air conditioner Status) Troubleshooting Connect wires according to wiring diagram to make sure all wiring terminals are connected firmly Stepping motor is damaged Stepping motor can't operate Repair or replace stepping motor Wrong wire connection, or poor connection Check the wiring status according to circuit diagram Main board is damaged Others are all normal, while horizontal louver can't operate Replace the main board with the same model 60 Installation and Maintenance Service Manual Check the circuit according to circuit diagram and connect wires correctly. Make sure all wiring terminals are connected firmly Replace batteries for remote controller Repair or replace remote controller Adjust the installation position, and install the rainproof and sunproof for outdoor unit Find out the leakage causes and deal with it. Add refrigerant. Replace the capillary
Service Manual 4. ODU Fan Motor Can't Operate Possible causes Discriminating method (air conditioner status) Troubleshooting Wrong wire connection, or poor connection Check the wiring status according to circuit diagram Measure the capacity of fan capacitor with an universal meter and find that the capacity is out of the deviation range indicated on the nameplate of fan capacitor. Capacity of the ODU fan motor is damaged Power voltage is a little low or high Use universal meter to measure the power supply voltage. The voltage is a little high or low Suggest to equip with voltage regulator When unit is on, cooling/heating performance is bad and ODU compressor generates a lot of noise and heat. Motor of outdoor unit is damaged 5. Compressor Can't Operate Possible causes Discriminating method (air conditioner status) Troubleshooting Wrong wire connection, or poor connection Check the wiring status according to circuit diagram Measure the capacity of fan capacitor with an universal meter and find that the capacity is out of the deviation range indicated on the nameplate of fan capacitor. Capacity of compressor is damaged Power voltage is a little low or high Use universal meter to measure the power supply voltage. The voltage is a little high or low Suggest to equip with voltage regulator Coil of compressor is burnt out Use universal meter to measure the resistance between compressor terminals and it's 0 Repair or replace compressor Cylinder of compressor is blocked Compressor can't operate Repair or replace compressor 6. Air Conditioner is Leaking Possible causes Discriminating method (air conditioner status) Troubleshooting Drain pipe is blocked Water leaking from indoor unit Eliminate the foreign objects inside the drain pipe Drain pipe is broken Water leaking from drain pipe Replace drain pipe Wrapping is not tight Water leaking from the pipe connection place of indoor unit Wrap it again and bundle it tightly 7. Abnormal Sound and Vibration Possible causes Discriminating method (air conditioner status) Troubleshooting When turn on or turn off the unit, the panel and other parts will expand and there's abnormal sound There's the sound of "PAPA" Normal phenomenon. Abnormal sound will disappear after a few minutes. When turn on or turn off the unit, there's abnormal sound due to flow of refrigerant inside air conditioner Water-running sound can be heard Normal phenomenon. Abnormal sound will disappear after a few minutes. Foreign objects inside the indoor unit or there're parts touching together inside the indoor unit Remove foreign objects. Adjust all parts' position of indoor unit, tighten screws and stick damping plaster between connected parts Foreign objects inside the outdoor unit or there're parts touching together inside the outdoor unit There's abnormal sound fro indoor unit Remove foreign objects. Adjust all parts' position of outdoor unit, tighten screws and stick damping plaster between connected parts Short circuit inside the magnetic coil There's abnormal sound fro outdoor unit During heating, the way valve has abnormal electromagnetic sound Replace magnetic coil Abnormal shake of compressor Outdoor unit gives out abnormal sound Adjust the support foot mat of compressor, tighten the bolts Abnormal sound inside the compressor Abnormal sound inside the compressor 61 Installation and Maintenance Connect wires according to wiring diagram to make sure all wiring terminals are connected firmly Replace the capacity of fan Change compressor oil and refrigerant. If no better, replace the compressor with a new one Connect wires according to wiring diagram to make sure all wiring terminals are connected firmly Replace the compressor capacitor If add too much refrigerant during maintenance, please reduce refrigerant properly. Replace compressor for other circumstances.
10. Exploded View and Parts List 10.1 Indoor Unit 15 16 14 13 33 12 11 10 9 7 8 6 5 4 3 2 1 The component is only for reference;please refer to the actual product. 62 Installation and Maintenance Service Manual 17 18 19 20 21 22 23 24 25 26 28 27
Service Manual NO. Description Part Code Product Code CV010N02900 CV010N02700 CV010N02800 1 Front Panel Assy 20012756 20012756 20012756 1 2 Filter Sub-Assy 11122139 11122139 11122139 1 3 Front Case Assy 20012601 20012601 20012601 1 4 Evaporator Assy 01100100160 01100100160 01100100164 1 5 Cold Plasma Generator 1114001604 1114001604 1114001604 1 6 Rear Case Assy 000001060071 000001000051 000001060071 1 7 Centrifugal Fan 10312005 10312005 10312005 1 8 Fan Motor 1570410001201 1570410001201 1570410001201 1 9 SteppingMotor 1521210101 1521210101 1521210101 1 10 Crank 73012005 73012005 73012005 1 11 Swing Assy 10102042 10102042 000211060003 1 12 Terminal Board 422000000022 422000000022 422000000022 1 13 Switch Board 30112007 30112007 30112007 1 14 Display Board 30568131 30568131 30568131 1 15 Fuse 46010055 46010055 46010055 1 16 Radiator / / / / 17 Signal Wire 4003004202 4003004202 4003004202 1 18 Jumper 4202300112 4202300111 4202300114 1 19 Main Board 300002000631 300002000631 300002000631 1 20 Electric Box 20112116 20112116 20112116 1 21 Electric Box Assy 100002002951 100002002848 100002002386 1 22 Air Louver (upper) 10512143 10512143 10512143 2 23 Swing Lever 10582096 10582096 10582096 1 24 Shaft of Guide Louver 10542020 10542020 10542020 1 25 Water Tray Assy 20182141 20182141 20182141 1 26 Air Louver (lower) 10512144 10512144 10512144 1 27 Axis (lower step motor) 10542034 10542034 10542034 1 28 SteppingMotor 1521210805 1521210805 1521210805 1 29 Connecting Cable 4002052317 4002052317 4002052317 0 30 Temperature Sensor 3900004508 3900004508 3900004508 1 31 Remote Controller 305001000111 305001000111 305001000111 1 32 Temperature Sensor 390000591 390000591 3900004508 1 33 Detecting Plate 30110154 30110154 30110154 1 Above data is subject to change without notice. 63 Installation and Maintenance Qty GEH12AA-K6DNA1A/I GEH09AA-K6DNA1F/I GEH18AA-K6DNA1F/I
NO. Description Part Code Qty GEH12AA-K6DNA1A/I GEH09AA-K6DNA1F/I GEH18AA-K6DNA1F/I Product Code CV010N02901 CV010N02701 CV010N02801 1 Front Panel Assy 20012756 20012756 20012756 1 2 Filter Sub-Assy 11122139 11122139 11122139 1 3 Front Case Assy 20012601 20012601 20012601 1 4 Evaporator Assy 01100100160 01100100160 01100100164 1 5 Cold Plasma Generator / / / / 6 Rear Case Assy 000001060071 000001000051 000001060071 1 7 Centrifugal Fan 10312005 10312005 10312005 1 8 Fan Motor 1570410001201 1570410001201 1570410001201 1 9 Stepping Motor 1521210101 1521210101 1521210101 1 10 Crank 73012005 73012005 73012005 1 11 Swing Assy 10102042 10102042 000211060003 1 12 Terminal Board 422000000022 422000000022 422000000022 1 13 Switch Board 30112007 30112007 30112007 1 14 Display Board 30568131 30568131 30568131 1 15 Fuse 46010055 46010055 46010055 1 16 Radiator / / / / 17 Signal Wire 4003004202 4003004202 4003004202 1 18 Jumper 4202300112 4202300111 4202300114 1 19 Main Board 300002000630 300002000630 300002000630 1 20 Electric Box 20112116 20112116 20112116 1 21 Electric Box Assy 100002060178 100002060177 100002060176 1 22 Air Louver (upper) 10512143 10512143 10512143 2 23 Swing Lever 10582096 10582096 10582096 1 24 Shaft of Guide Louver 10542020 10542020 10542020 1 25 Water Tray Assy 20182141 20182141 20182141 1 26 Air Louver (lower) 10512144 10512144 10512144 1 27 Axis (lower step motor) 10542034 10542034 10542034 1 28 Stepping Motor 1521210805 1521210805 1521210805 1 29 Connecting Cable 4002052317 4002052317 4002052317 0 30 Temperature Sensor 3900004508 3900004508 3900004508 1 31 Remote Controller 305001000111 305001000111 305001000111 1 32 Temperature Sensor 3900004508 3900004508 3900004508 1 33 Detecting Plate 30110154 30110154 30110154 1 Above data is subject to change without notice. 64 Installation and Maintenance Service Manual
Service Manual 10.2 Outdoor Unit GEH12AA-K6DNA1A/O 1 2 3 4 5 7 21 22 23 24 25 20 19 18 17 16 The component picture is only for reference; please refer to the actual product. 65 Installation and Maintenance 6 28 8 9 10 11 12 13 14 15 26 27
NO. Description Part Code Product Code CV010W02900 1 Left Side Plate 01303200P 1 2 Fan Motor 1501308511 1 3 Motor Support 01703136 1 4 Condenser Assy 011002060521 1 5 Top Cover Sub-Assy 000051060038 1 6 Rear Grill 01475014 1 7 Clapboard Sub-Assy 01233180 1 8 Compressor and Fittings 009001060066 1 9 Compressor Gasket 009012000027 3 10 4-Way Valve Assy 030152060255 1 11 Big Handle 2623343106 1 12 Valve Cover 22243006 1 13 Cut off Valve 071302391 1 14 Cut off Valve 07130239 1 15 Valve Support 0171314201P 1 16 Front Grill 22413047 1 17 Cabinet 01433033P 1 18 Axial Flow Fan 10333011 1 19 Chassis Sub-assy 017000060080P 1 20 Electric Box Assy 100002064438 1 21 Electric Box 20113034 1 22 Main Board 300027060573 1 23 Reactor 43130184 1 24 Wire Clamp 71010103 1 25 Terminal Board 422000060016 1 26 Electrical Heater / / 27 Electrical Heater (Chassis) 7651000414 1 28 Electric Expansion Valve Sub-Assy 030026060275 1 Above data is subject to change without notice. 66 Installation and Maintenance Service Manual Qty GEH12AA-K6DNA1A/O
Service Manual GEH09AA-K6DNA1F/O The component is only for reference;please refer to the actual product. 67 Installation and Maintenance
NO. Description Part Code Product Code CV010W02700 1 Electric Box Assy 100002064342 1 2 Electric Box Sub-Assy 017007060831 1 3 Main Board 300027060561 1 4 Reactor 43130184 1 5 Terminal Board 422000060016 1 6 Wire Clamp 71010103 1 7 Front Grill 22413049 1 8 Front Panel 01533034P 1 9 Axial Flow Fan 10333004 1 10 Chassis Sub-assy 017000060298P 1 11 Fan Motor 1501308511 1 12 Small Handle 26233100 1 13 Top Cover Sub-Assy 000051060006 1 14 Motor Support 01703104 1 15 Condenser Assy 011002060497 1 16 Rear Grill 01473009 1 17 Electronic Expansion Valve 07133821 1 18 Cut off Valve 071302391 1 19 Big Handle 262334332 1 20 Valve 07100003 1 21 Valve Support 0171314201P 1 22 Right Side Plate Sub-Assy 00013006002001 1 23 4-Way Valve Assy 030152060251 1 24 Clapboard Sub-Assy 0123338502 1 25 Magnet Coil 4300040050 1 26 Compressor and Fittings 009001060050 1 27 Drainage Connecter 06123401 1 28 Electrical Heater(Compressor) 7651000414 1 Above data is subject to change without notice. 68 Installation and Maintenance Service Manual Qty GEH09AA-K6DNA1F/O
Service Manual GEH18AA-K6DNA1F/O The component is only for reference;please refer to the actual product. 69 Installation and Maintenance
NO. Description Part Code Product Code CV010W02800 1 Front Grill 22413045 1 2 Front Panel 01535013P 1 3 Drainage Connecter 06123401 1 4 Chassis Sub-assy 02803270P 1 5 Drainage hole Cap 06813401 1 6 Compressor and fittings 00103919G 1 7 Magnet Coil 4300040087 1 8 4-Way Valve Assy 030152060322 1 9 Cut off Valve Assy 1/2 07133774 1 10 Cut off Valve Sub-Assy 07133058 1 11 Valve support assy 01715010P 1 12 Right Side Plate 0130509402P 1 13 Valve cover 22245002 1 14 Handle 26233053 1 15 Wiring Clamp 26115004 1 16 Electronic Expansion Valve assy 07133774 1 17 Electric Expand Valve Fitting 030174000058 1 18 Rear Grill 01473043 1 19 Condenser Assy 0116348702 1 20 Reactor / / 21 Clapboard Assy 01233153 1 22 Coping 012049000007P 1 23 Supporting Board(Condenser) 01795010 1 24 Motor Support Sub-Assy 01705036 1 25 Fan Motor 1501506402 1 26 Axial Flow Fan 10335008 1 27 Left Side Plate 01305093P 1 28 left handle 2623525404 1 29 Electric Box Assy 100002064320 1 30 Wire Clamp 71010003 1 31 Terminal Board 422000060009 1 32 Electric Box 20113027 1 33 Radiator 49013060 1 34 Main Board 300027060548 1 35 Insulated Board (Cover of Electric Box) 20113003 1 36 Temperature Sensor 3900030901 1 Above data is subject to change without notice. 70 Installation and Maintenance Service Manual Qty GEH18AA-K6DNA1F/O
Service Manual 11. Removal Procedure 11.1 Removal Procedure of Indoor Unit Steps Procedure 1. Remove panel Pull sliding clasps at both sides of panel, pull out the panel outwards and then move the panel upwards to remove it. 2. Remove filter sub-assy Pull the damping clasps at upper/lower side of filter sub-assy, and then move the filter sub-assy outwards to remove it. 3. Remove test board and front case Remove one screws fixing the test board, and t hen pull the test board outwards to remove it. Remove 4 screws fixing the front case, and then pull the front case outwards to remove it. 71 Installation and Maintenance Warning: Be sure to wait for a minimum of 20 minutes after turning off all power supplies and discharge the refrigerant completely before removal. panel sliding clasps filter sub-assy damping clasps screws front case test board
4. Remove swing parts Remove 2 screws fixing the swing parts, and then pull the swing parts outwards to remove it. 5. Remove water tray Remove 2 screws fixing water tray, and then pull the water tray outwards to remove it. 6. Remove electric box Remove one screw fixing the electric box, and then pull the electric box outwards to remove it. 72 Installation and Maintenance Service Manual swing parts screw water tray screws screws electric box
Service Manual 7. Remove fixer of piping Pry out the clasps connecting fixer of piping and bottom case, and then pull the fixer of piping outwards to remove it. 8. Remove evaporator Pry out the clasps connecting evaporator evaporator clasps and bottom case, and then pull the evaporator outwards to remove it. 9. Remove guide ring Remove 4 screws fixing guide ring, and then pull the guide ring outwards to remove it. screws 73 Installation and Maintenance clasps fixer of piping guide ring
10. Remove centrifugal blade Remove one nut fixing the centrifugal blade, and then pull the centrifugal blade outwards to remove it. 11. Remove fixing bracket of motor Remove 3 nuts on fixing bracket of motor, and then pull the fixing bracket of motor outwards to remove it. 12. Remove press plate of motor wire Loosen clasps between press plate of motor wire and bottom case, and then pull the press plate of motor wire outwards to remove it. 74 Installation and Maintenance Service Manual nut centrifugal blade fixing bracket of motor nuts clasps press plate of motorwire
Service Manual 11.2 Removal Procedure of Outdoor Unit GEH09AA-K6DNA1F/O Procedure Steps 1. Remove big handle Remove the screw fixing big handle; slide out the big handle upwards to make the clasp of big handle separate from the groove of right side plate, and then remove the big handle. 2. Remove top panel Remove the screws fixing top panel and then remove the top panel. 3. Remove front grille Remove connection screws between the front grille and the front panel. Then remove the front grille. 75 Installation and Maintenance Right side plate Screw Big handle Screws Top panel Screw Front grille Screws
Procedure Steps 4. Remove front panel Remove the screws fixing front panel,and then remove the front panel. 5. Remove axial flow blade Remove the nut fixing axial flow blade and then remove the axial flow blade. 76 Installation and Maintenance Service Manual Screws Screws Screws Panel Screws Nut Axial flow blade
Service Manual Procedure Steps 6. Remove protective grille and right side plate Remove the screws 1 fixing protective grille and then remove the protective grille. Remove the screws 2 fixing right side plate and then remove the right side plate. 7. Remove electric box assy Remove the screws fixing electric box assy ; pull out each wiring terminal; lift the electric box assy upwards to remove it. Note: When pulling out the wiring terminal, pay attention to loose the clasp and don’t pull it so hard. 77 Installation and Maintenance Protective grille Screws 2 Screws 1 Right side plate Right side plate Screws 2 Screws Electric box assy
Procedure Steps 8. Remove 4-way valve assy Unsolder the spot weld of 4-way valve assy, compressor and condenser, and then remove the 4-way valve assy . Note: When unsoldering the spot weld, wrap the 4-way valve with wet cloth completely to avoid damaging the valve due to high temperature. 9. Remove motor Remove the screws fixing motor and then remove the motor. 10. Remove motor support Remove the screws fixing motor support and then remove the motor support. 78 Installation and Maintenance Service Manual 4-way valve assy Spot weld Motor Screws Motor support Screws
Service Manual Procedure Steps 11. Remove gas valve and liquid valve Remove two screws fixing the gas valve, then remove the gas valve. Remove two screws fixing the liquid valve, then remove the liquid valve. 12. Remove clapboard Remove the screws fixing clapboard and then remove the clapboard. 13. Remove valve support Remove the screws fixing valve support and then remove the valve support. 79 Installation and Maintenance Liquid valve Screws Gas valve Screws Clapboard Screws Valve support Screws
Procedure Steps 14. Remove compressor Remove 3 foot nuts on compressor, and then remove the compressor. Note: Protect the ports of discharge pipe and suction pipe to avoid foreign objects to enter it. 15. Remove condenser Remove one screw fixing the condenser, then remove the condenser. 80 Installation and Maintenance Service Manual Compressor Foot nuts Condenser Screw
Service Manual GEH12AA-K6DNA1A/O 81 Installation and Maintenance
Step Remove grille 4. Remove connection screws between the front grille and the front panel. Then remove the grille. 5. Remove front panel Remove connection screws connecting the front panel with the chassis and the motor support and then remove the front panel. 6. Remove right side plate and support plate Remove connection screws connecting the right side plate with the valve support and the electric box. Then remove the right side plate. plate and chassis, and then remove the support plate. Remove the nut on the blade and then 82 Installation and Maintenance Service Manual Procedure grille front panel support plate right side plate
Service Manual Step 8. Remove motor and motor support motor and disconnect the leading wire insert of the motor. Then remove the motor. motor support and lift the motor support to remove it. 9. Remove Electric Box Assy subassembly; loosen the wire bundle and unplug the wiring terminals. Then lift the electric box to remove it. 10. Remove isolation sheet sheet and then remove the isolation sheet. 11. Remove compressor Unsolder the welding joint connecting the capillary, valves and the outlet pipe of condenser to remove the capillary. Do not block the capillary with welding slag during unsoldering. a 83 Installation and Maintenance Procedure motor support motor electric Box Assy isolation sheet liquid valve gas valve
Procedure Step and unsolder the welding joint between the gas valve and the air-return pipe to remove the gas valve. (NOTE: Discharge the refrigerant completely before unsoldering; when unsoldering, wrap the gas valve with a wet cloth completely to avoid damage to the valve caused by high temperature). b valve and unsolder the welding joint connecting the liquid valve to the Y-type pipe to remove the liquid valve. c Unsolder pipes connecting with compressor. d Remove the 3 foot nuts on the compressor and then remove the compressor. 84 Installation and Maintenance Service Manual 4-way valve compressor nuts
Service Manual GEH18AA-K6DNA1F/O Procedure Steps 1. Remove handle and valve cover Remove the screws used for fixing the handle and valve cover,pull the handle and valve cover up ward to remove them. 2. Remove top panel Remove the screws fixing top panel and then remove the top panel. 3. Remove front grille Remove connection screws between the front grille and the front panel. Then remove the front grille. 85 Installation and Maintenance Handle Screw Screw Valve cover Screws Screws Top panel Screw Front grille Screws
Procedure Steps 4. Remove front panel Remove the screws connecting the front panel with the chassis and the motor support, and then remove the front panel. 5. Remove rear grill and right side plate Remove the screws 1 connecing the left side plate and right side plate and then remove rear grill. Remove the screws 2 connecting the right side plate with the chassis, the valve support and the electric box, and then remove the right side plate . 86 Installation and Maintenance Service Manual Screws Front panel Screws Rear grill Screws 2 Right side plate Screws 1 Screws 2 Screws 2 Right side plate Screws 2
Service Manual Procedure Steps 6. Remove left side plate Remove the screws connecting the left side plate and the chassis, and then remove the left side plate. 7. Remove axial flow blade Remove the nut fixing the blade and then remove the axial flow blade. 8. Remove motor and motor support Remove the screws fixing motor and then remove the motor. Remove the screws fixing motor support and then remove the motor support. 87 Installation and Maintenance Left side plate Screws Nut Axial flow blade Motor Screws Motor support Screws
Procedure Steps 9. Remove electric box assy Remove the screws fixing electric box assy ; pull out each wiring terminal; lift the electric box assy upwards to remove it. Note: When pulling out the wiring terminal, pay attention to loose the clasp and don’t pull it so hard. 10. Remove soundproof sponge Since the piping ports on the soundproof sponge are torn easily, remove the soundproof sponge carefully. 11. Remove 4-way valve assy Unsolder the spot weld of 4-way valve assy, compressor and condenser, and then remove the 4-way valve assy . Note: When unsoldering the spot weld, wrap the 4-way valve with wet cloth completely to avoid damaging the valve due to high temperature. 88 Installation and Maintenance Service Manual Screws Electric box assy Soundproof sponge Remove 4-way valve assy Screws Screws
Service Manual Procedure Steps 12. Remove clapboard Remove the screws fixing clapboard and then remove the clapboard. 13. Remove gas valve ,liquid valve and valve support Since the piping ports on the soundproof sponge are torn easily, remove the soundproof sponge carefully. 14. Remove compressor Remove 3 foot nuts on compressor, and then remove the compressor. Note: Protect the ports of discharge pipe and suction pipe to avoid foreign objects to enter it. 89 Installation and Maintenance Clapboard Screws Liquid valve Screws Screws Gas valve Screws Valve support Compressor Screws
Service Manual Appendix: Appendix 1: Reference Sheet of Celsius and Fahrenheit Set temperature Conversion formula for Fahrenheit degree and Celsius degree: Tf=Tcx1.8+32 Fahrenheit Fahrenheit display temperature Fahrenheit display temperature Fahrenheit (℉) Celsius(℃) (℉) Celsius(℃) (℉) (℉) 61 60.8 16 69/70 69.8 21 78/79 78.8 26 62/63 62.6 17 71/72 71.6 22 80/81 80.6 27 64/65 64.4 18 73/74 73.4 23 82/83 82.4 28 66/67 66.2 19 75/76 75.2 24 84/85 84.2 29 68 68 20 77 77 25 86 86 30 Ambient temperature Fahrenheit Fahrenheit display temperature Fahrenheit display temperature Fahrenheit (℉) Celsius(℃) (℉) Celsius(℃) (℉) (℉) 32/33 32 0 55/56 55.4 13 79/80 78.8 26 34/35 33.8 1 57/58 57.2 14 81 80.6 27 36 35.6 2 59/60 59 15 82/83 82.4 28 37/38 37.4 3 61/62 60.8 16 84/85 84.2 29 39/40 39.2 4 63 62.6 17 86/87 86 30 41/42 41 5 64/65 64.4 18 88/89 87.8 31 43/44 42.8 6 66/67 66.2 19 90 89.6 32 45 44.6 7 68/69 68 20 91/92 91.4 33 46/47 46.4 8 70/71 69.8 21 93/94 93.2 34 48/49 48.2 9 72 71.6 22 95/96 95 35 50/51 50 10 73/74 73.4 23 97/98 96.8 36 52/53 51.8 11 75/76 75.2 24 99 98.6 37 54 53.6 12 77/78 77 25 Appendix 2: Configuration of Connection Pipe 1.Standard length of connection pipe(More details please refer to the specifications) 2.Min length of connection pipeFor the unit with standard connection pipe of 5m, there is no limitation for themin length of connection pipe. For the unit with standard connection pipe of 7.5m and 8m, the min length of connection pipe is 3m. 3.Max length of connection pipe(More details please refer to the specifications) 4.The additional refrigerant oil and refrigerant charging required after prolonging connection pipe ● After the length of connection pipe is prolonged for 10m at the basis of standard length, you should add 5ml of refrigerant oil for each additional 5m of connection pipe. ● The calculation method of additional refrigerant charging amount (on the basis of liquid pipe): ● Basing on the length of standard pipe, add refrigerant according to the requirement as shown in the table. The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe. See Sheet 2. ● Additional refrigerant charging amount = prolonged length of liquid pipe X additional refrigerant charging amount per meter Additional refrigerant charging amount for R32 Diameter of connection pipe Indoor unit throttl Outdoor unit throttle Liquid pipe Gas pipe Cooling only,cooling and heating(g / m) Cooling only(g / m) Cooling and heating(g / m) Ф6 Ф9.5 or Ф12 16 12 16 Ф6 or Ф9.5 Ф16 or Ф19 40 12 40 Ф12 Ф19 or Ф22.2 80 24 96 Ф16 Ф25.4 or Ф31.8 136 48 96 Ф19 / 200 200 200 Ф22.2 / 280 280 280 Note: The additional refrigerant charging amount in Sheet 2 is recommendedvalue, not compulsory. 90 Installation and Maintenance Fahrenheit display temperature Fahrenheit (℉) Celsius(℃) (℉) Fahrenheit display temperature Fahrenheit (℉) Celsius(℃) (℉)
Service Manual Appendix 3: Pipe Expanding Method Note: Improper pipe expanding is the main cause of refrigerant leakage.Please expand the pipe according to the following steps: A:Cut the pip ● Confirm the pipe length according to the distance of indoor unit and outdoor unit. ● Cut the required pipe with pipe cutter. B:Remove the burrs ● Remove the burrs with shaper and prevent the burrs from getting into the pipe. C:Put on suitable insulating pipe D:Put on the union nut ● Remove the union nut on the indoor connection pipe and outdoor valve; install the union nut on the pipe. E:Expand the port ● Expand the port with expander. Note: ● "A" is different according to the diameter, please refer to the sheet below: Outer diameter(mm) A(mm) Max Min Ф6 - 6.35 (1/4") 1.3 0.7 Ф9.52 (3/8”) 1.6 1.0 Ф12 - 12.70 (1/2”) 1.8 1.0 Ф16 - 15.88 (5/8”) 2.4 2.2 F:Inspection ● Check the quality of expanding port. If there is any blemish, expand the port again according to the steps above. 91 Installation and Maintenance Pipe Pipe cutter Leaning Uneven Burr Pipe Shaper Downwards Union pipe Pipe Hard mold Expander Pipe Smooth surface Improper expanding leaning damaged crack uneven thickness surface The length is equal
Appendix 4: List of Resistance for Temperature Sensor Resistance Table of Ambient Temperature Sensor for Indoor and Outdoor Units(15K) Temp( oC) Resistance(kΩ) Temp( oC) Resistance(kΩ) Temp( oC) Resistance(kΩ) Temp( -19 138.1 20 18.75 59 3.848 98 1.071 -18 128.6 21 17.93 60 3.711 99 1.039 -17 121.6 22 17.14 61 3.579 100 1.009 -16 115 23 16.39 62 3.454 101 0.98 -15 108.7 24 15.68 63 3.333 102 0.952 -14 102.9 25 15 64 3.217 103 0.925 -13 97.4 26 14.36 65 3.105 104 0.898 -12 92.22 27 13.74 66 2.998 105 0.873 -11 87.35 28 13.16 67 2.896 106 0.848 -10 82.75 29 12.6 68 2.797 107 0.825 -9 78.43 30 12.07 69 2.702 108 0.802 -8 74.35 31 11.57 70 2.611 109 0.779 -7 70.5 32 11.09 71 2.523 110 0.758 -6 66.88 33 10.63 72 2.439 111 0.737 -5 63.46 34 10.2 73 2.358 112 0.717 -4 60.23 35 9.779 74 2.28 113 0.697 -3 57.18 36 9.382 75 2.206 114 0.678 -2 54.31 37 9.003 76 2.133 115 0.66 -1 51.59 38 8.642 77 2.064 116 0.642 0 49.02 39 8.297 78 1.997 117 0.625 1 46.6 40 7.967 79 1.933 118 0.608 2 44.31 41 7.653 80 1.871 119 0.592 3 42.14 42 7.352 81 1.811 120 0.577 4 40.09 43 7.065 82 1.754 121 0.561 5 38.15 44 6.791 83 1.699 122 0.547 6 36.32 45 6.529 84 1.645 123 0.532 7 34.58 46 6.278 85 1.594 124 0.519 8 32.94 47 6.038 86 1.544 125 0.505 9 31.38 48 5.809 87 1.497 126 0.492 10 29.9 49 5.589 88 1.451 127 0.48 11 28.51 50 5.379 89 1.408 128 0.467 12 27.18 51 5.197 90 1.363 129 0.456 13 25.92 52 4.986 91 1.322 130 0.444 14 24.73 53 4.802 92 1.282 131 0.433 15 23.6 54 4.625 93 1.244 132 0.422 16 22.53 55 4.456 94 1.207 133 0.412 17 21.51 56 4.294 95 1.171 134 0.401 18 20.54 57 4.139 96 1.136 135 0.391 19 19.63 58 3.99 97 1.103 136 0.382 92 Installation and Maintenance Service Manual oC) Resistance(kΩ)
Service Manual Resistance Table of Tube Temperature Sensors for Outdoor and Indoor(20K) oC) Resistance(kΩ) Temp( oC) Resistance(kΩ) Temp( oC) Resistance(kΩ) Temp( Temp( -19 181.4 20 25.01 59 5.13 98 1.427 -18 171.4 21 23.9 60 4.948 99 1.386 -17 162.1 22 22.85 61 4.773 100 1.346 -16 153.3 23 21.85 62 4.605 101 1.307 -15 145 24 20.9 63 4.443 102 1.269 -14 137.2 25 20 64 4.289 103 1.233 -13 129.9 26 19.14 65 4.14 104 1.198 -12 123 27 18.13 66 3.998 105 1.164 -11 116.5 28 17.55 67 3.861 106 1.131 -10 110.3 29 16.8 68 3.729 107 1.099 -9 104.6 30 16.1 69 3.603 108 1.069 -8 99.13 31 15.43 70 3.481 109 1.039 -7 94 32 14.79 71 3.364 110 1.01 -6 89.17 33 14.18 72 3.252 111 0.983 -5 84.61 34 13.59 73 3.144 112 0.956 -4 80.31 35 13.04 74 3.04 113 0.93 -3 76.24 36 12.51 75 2.94 114 0.904 -2 72.41 37 12 76 2.844 115 0.88 -1 68.79 38 11.52 77 2.752 116 0.856 0 65.37 39 11.06 78 2.663 117 0.833 1 62.13 40 10.62 79 2.577 118 0.811 2 59.08 41 10.2 80 2.495 119 0.77 3 56.19 42 9.803 81 2.415 120 0.769 4 53.46 43 9.42 82 2.339 121 0.746 5 50.87 44 9.054 83 2.265 122 0.729 6 48.42 45 8.705 84 2.194 123 0.71 7 46.11 46 8.37 85 2.125 124 0.692 8 43.92 47 8.051 86 2.059 125 0.674 9 41.84 48 7.745 87 1.996 126 0.658 10 39.87 49 7.453 88 1.934 127 0.64 11 38.01 50 7.173 89 1.875 128 0.623 12 36.24 51 6.905 90 1.818 129 0.607 13 34.57 52 6.648 91 1.736 130 0.592 14 32.98 53 6.403 92 1.71 131 0.577 15 31.47 54 6.167 93 1.658 132 0.563 16 30.04 55 5.942 94 1.609 133 0.549 17 28.68 56 5.726 95 1.561 134 0.535 18 27.39 57 5.519 96 1.515 135 0.521 19 26.17 58 5.32 97 1.47 136 0.509 93 Installation and Maintenance oC) Resistance(kΩ)
Resistance Table of Discharge Temperature Sensor for Outdoor(50K) oC) Resistance(kΩ) Temp( Temp( -29 853.5 10 98 49 18.34 88 4.75 -28 799.8 11 93.42 50 17.65 89 4.61 -27 750 12 89.07 51 16.99 90 4.47 -26 703.8 13 84.95 52 16.36 91 4.33 -25 660.8 14 81.05 53 15.75 92 4.20 -24 620.8 15 77.35 54 15.17 93 4.08 -23 580.6 16 73.83 55 14.62 94 3.96 -22 548.9 17 70.5 56 14.09 95 3.84 -21 516.6 18 67.34 57 13.58 96 3.73 -20 486.5 19 64.33 58 13.09 97 3.62 -19 458.3 20 61.48 59 12.62 98 3.51 -18 432 21 58.77 60 12.17 99 3.41 -17 407.4 22 56.19 61 11.74 100 3.32 -16 384.5 23 53.74 62 11.32 101 3.22 -15 362.9 24 51.41 63 10.93 102 3.13 -14 342.8 25 49.19 64 10.54 103 3.04 -13 323.9 26 47.08 65 10.18 104 2.96 -12 306.2 27 45.07 66 9.83 105 2.87 -11 289.6 28 43.16 67 9.49 106 2.79 -10 274 29 41.34 68 9.17 107 2.72 -9 259.3 30 39.61 69 8.85 108 2.64 -8 245.6 31 37.96 70 8.56 109 2.57 -7 232.6 32 36.38 71 8.27 110 2.50 -6 220.5 33 34.88 72 7.99 111 2.43 -5 209 34 33.45 73 7.73 112 2.37 -4 198.3 35 32.09 74 7.47 113 2.30 -3 199.1 36 30.79 75 7.22 114 2.24 -2 178.5 37 29.54 76 7.00 115 2.18 -1 169.5 38 28.36 77 6.76 116 2.12 0 161 39 27.23 78 6.54 117 2.07 1 153 40 26.15 79 6.33 118 2.02 2 145.4 41 25.11 80 6.13 119 1.96 3 138.3 42 24.13 81 5.93 120 1.91 4 131.5 43 23.19 82 5.75 121 1.86 5 125.1 44 22.29 83 5.57 122 1.82 6 119.1 45 21.43 84 5.39 123 1.77 7 113.4 46 20.6 85 5.22 124 1.73 8 108 47 19.81 86 5.06 125 1.68 9 102.8 48 19.06 87 4.90 126 1.64 94 Installation and Maintenance Service Manual oC) Resistance(kΩ) Temp( oC) Resistance(kΩ) Temp( oC) Resistance(kΩ)
GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 Tel: (+86-756) 8522219 Fax: (+86-756) 8669426 E-mail: global@cn.gree.com www.gree.com For product improvement, specifications and appearance in this manual are subject to change without prior notice. JF00303896