Change for life

Owner's Manual

Original Instructions

Console Type Air Conditioner

Thank you for choosing our product.
Please read this Owner’s Manual carefully before operation and 
retain it for future reference.
If you have lost the Owner's Manual, please contact the local agent 
or visit www.gree.com or send an email to global@cn.gree.com for
the electronic version.

Sayfa 2

GEH09AAXB-K6DNA1A/I
 
GEH12AAXD-K6DNA1A/I
GEH18AAXF-K6DNA1A/I

Sayfa 3

Contents

The Refrigerant ..........................................................................................................................................1 

Precautions ............................................................................................................................................... 2

Maintenance .............................................................................................................................................. 7

Operating guide ....................................................................................................................................... 10

Precautions .............................................................................................................................................. 12

Checking before contact the service man ................................................................................................ 13

Installation of indoor unit .......................................................................................................................... 14

Refrigerant piping work ............................................................................................................................ 22

Routine check after installation ................................................................................................................ 23

Part names and their functions ................................................................................................................. 24

How to use the remote control to operate the unit .................................................................................... 25

Configuration of connection pipe .............................................................................................................. 30

Safety operation of flammable refrigerant ................................................................................................. 32

Pipe preparation........................................................................................................................................ 34

Specialist’s Manual.................................................................................................................................... 35

Thank you for selecting our products
One of the benefits awaiting you with our room air conditioner is not only comfort of life but 

also good health. This operation instruction brings you the many omfort and technological 

features your unit has to offer. In addition, it provides you vital information about 

maintenance, service and economical operating. Take the next few minutes to discover 

how to get your comfort and economy of the operation from your new room air conditioner.

The figures in this manual may be different with the material objects, please refer to the 

material objects for reference.

This appliance is not intended for use by persons (including children) with reduced 
physical,sensory or mental capabilities,or lack of experience and knowledge,unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.Children should be supervised to ensure that they do 
not play with the appliance.

External static pressures at the appliance was tested is 0 Pa
Fuse link: T250 V; 3.15 A

Hereby, Our company, declares that this Air Conditioner is in compliance with the essential 
requirement and other relevant provisions of RE Directive 2014/53/EU. A copy of the full 
DoC is attached. Wireless frequency range: 2412MHz - 2472MHz
Maximum Transmit Power: 18dBm

This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm  
to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of
material resources. To return your used device, please use the return and collection systems or contact the retailer where
the product was purchased. They can take this product for environmental safe recycling.

R32: 675

Sayfa 4

Explanation of Symbols

DANGER

WARNING

CAUTION

NOTICE

Exception Clauses
Manufacturer will bear no responsibilities when personal injury or 
property loss is caused by the following reasons.

Damage the product due to improper use or misuse of the product;
1.

2.Alter, change, maintain or use the product with other equipment without abiding

by the instruction manual of manufacturer;

After verification, the defect of product is directly caused by corrosive gas;
3.

After verification, the defects are due to improper operation during transportation
of product;
4.

Operate, repair, maintain the unit without abiding by instruction manual or related
regulations;
5.

After verification, the problem or dispute is caused by the quality specification or
performance of parts and components that produced by other manufacturers;
6.

The damage is caused by natural calamities, bad using environment or force
majeure.
7.

If it needs to install, move or maintain the air conditioner, please contact dealer 
or local service center to conduct it at first. Air conditioner must be installed, 
moved or maintained by appointed  unit. Otherwise, it may cause serious 
damage or personal injury or death.
When refrigerant leaks or requires discharge during installation, maintenance, 
or disassembly, it should be handled by certified professionals or otherwise in 
compliance with local laws and regulations.

Indicates a hazardous situation that, if not avoided, will
result in death or serious injury.  

Indicates a hazardous situation that, if not avoided, could 
result in death or serious injury. 

Indicates a hazardous situation that, if not avoided, may
result in minor or moderate injury.  

Indicates important but not hazard-related information, 
used to indicate risk of property damage. 

Indicates a hazard that would be assigned a signal word 
WARNING or CAUTION.

Sayfa 5

Appliance filled with flammable gas R32.

Before use the appliance, read the owner’s manual first.

Before install the appliance, read the installation manual first.

Before repair the appliance, read the service manual first.

The Refrigerant

To realize the function of the air conditioner unit, a special refrigerant circulates in
the system. The used refrigerant is the fluoride R32, which is specially cleaned. 
The refrigerant is flammable and inodorous. Furthermore, it can lead to explosion 
under certain conditions. But the flammability of the refrigerant is very low. It can
be ignited only by fire.

Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm
to the ozonosphere. The influence upon the greenhouse effect is also lower. R32
has got very good thermodynamic features which lead to a really high energy
efficiency. The units therefore need a less filling.

WARNING

Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacture. Should repair be necessary, contact your nea-
rest authorized Service Centre. Any repairs carried out by unqualified personnel
may be dangerous. The appliance shall be stored in a room without continuously
operating ignition sources. (for example: open flames, an operating gas appliance
or an operating electric heater.) Do not pierce or burn.

Appliance shall be installed, operated and stored in a room with a floor area larger

than X m . 
2

 (Please refer to table "a" in section of " Safety operation of flammable 

refrigerant " for Space X.)

Appliance filled with flammable gas R32. For repairs, strictly follow manufacturer’s
instructions only. Be aware that refrigerants may not contain an odour. Read specialist’s
manual.

1

Sayfa 6

Precautions

This appliance can be used by children aged from 8 
Operation and Maintenance

years and above and persons with reduced physical, 
sensory or mental capabilities or lack of experience 
and knowledge if they have been given supervision or 
instruction concerning use of the appliance in a safe 
way and understand the hazards involved. 

Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by 
children without supervision.

Do not connect air conditioner to multi-purpose socket.

Otherwise, it may cause fire hazard.

Do disconnect power supply when cleaning air 
conditioner. Otherwise, it may cause electric shock.

If the supply cord is damaged, it must be replaced by 
the manufacturer, its service agent or similarly qualified 
persons in order to avoid a hazard.

Do not wash the air conditioner with water to avoid 
electric shock.

Do not spray water on indoor unit. It may cause electric
shock or malfunction.

After removing the filter, do not touch fins to avoid injury.
Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.

WARNING

2

Sayfa 7

Precautions

Maintenance must be performed by qualified 
professionals. Otherwise, it may cause personal injury 
or damage.

Do not repair air conditioner by yourself. It may cause 

electric shock or damage. Please contact dealer when 
you need to repair air conditioner. 

Do not extend fingers or objects into air inlet or air 

outlet. It may cause personal injury or damage.

Do not block air outlet or air inlet. It may cause 
malfunction.

Do not spill water on the remote controller, otherwise the 

remote controller may be broken.

When below phenomenon occurs, please turn off air 

conditioner and disconnect power immediately, and then 

contact the dealer or qualified professionals for service.

● Power cord is overheating or damaged.

● There’s abnormal sound during operation.

● Circuit break trips off frequently.

● Air conditioner gives off burning smell.

● Indoor unit is leaking.

If the air conditioner operates under abnormal conditions, 
it may cause malfunction, electric shock or fire hazard.

When turning on or turning off the unit by emergency 
operation switch, please press this switch with an insulating 
object other than metal.

objects. It may cause damage or personal injury.
Do not step on top panel of outdoor unit, or put heavy 

WARNING

3

Sayfa 8

Precautions

Attachment

Installation must be performed by qualified professionals. 
Otherwise, it may cause personal injury or damage.

Must follow the electric safety regulations when installing 
the unit.

According to the local safety regulations, use qualified 

power supply circuit and circuit break.

Do install the circuit break. If not, it may cause malfunction. 

An all-pole disconnection switch having a contact separation 

of at least 3mm in all poles should be connected in fixed 
wiring.

Including an circuit break with suitable capacity, please 

note the following table.Air switch should be included 

magnet buckle and heating buckle function, it can protect
the circuit-short and overload.

Air Conditioner should be properly grounded. Incorrect 

Don't use unqualified power cord.
grounding may cause electric shock.

Make sure the power supply matches with the requirement
of air conditioner. Unstable power supply or incorrect wiring
may result in electric shock, fire hazard or malfunction.
Please install proper power supply cables before using the
air conditioner.

grounding wire of power socket.
Properly connect the live wire, neutral wire and 

any work related to electricity and safety.
Be sure to cut off the power supply before proceeding 

WARNING

4

Sayfa 9

Precautions

Do not put through the power before finishing installation.

the manufacturer, its service agent or similarly qualified 
If the supply cord is damaged, it must be replaced by 

persons in order to avoid a hazard.

The temperature of refrigerant circuit will be high, please 

keep the interconnection cable away from the copper 
tube.

The appliance shall be installed in accordance with 

national wiring regulations.

Installation must be performed in accordance with the 

requirement of NEC and CEC by authorized personnel 
only.

The air conditioner is the first class electric appliance. It 

must be properly grounding with specialized grounding 
device by a professional. Please make sure it is always 
grounded effectively, otherwise it may cause electric shock.

The yellow-green wire in air conditioner is grounding 

wire, which can't be used for other purposes.
The grounding resistance should comply with national 
electric safety regulations.

The appliance must be positioned so that the plug is 
accessible.

All wires of indoor unit and outdoor unit should be 
connected by a professional. 

If the length of power connection wire is insufficient, please 
contact the supplier for a new one. Avoid extending the 
wire by yourself.

WARNING

5

Sayfa 10

Precautions

For the air conditioner with plug, the plug should be  

reachable after finishing installation.

If you need to relocate the air conditioner to another 
must be installed in the line.
For the air conditioner without plug, an circuit break 

place, only the qualified person can perform the work. 
Otherwise, it may cause personal injury or damage.

Select a location which is out of reach for children and 

far away from animals or plants.If it is unavoidable, 
please add the fence for safety purpose.

The indoor unit should be installed close to the wall. 

WARNING

6

Sayfa 11

Maintenance

Before inspection and maintenance of the unit. PLEASE set power switch to “OFF” to cut off the
power supply.

1 Units

●Indoor unit, Outdoor unit and Remote controller

1. Wipe them with dry soft cloth.

●Front panel

1. Open the front panel.

Slide the two stoppers on the left and right sides inward until they click.

2. Remove the front panel.

• Remove the string.

• Allowing the front panel to fall forward will enable you to remove it.

3. Clean the front panel.

• Wipe it with a soft cloth soaked in water.

• Only neutral detergent may be used.

• In case of washing the front panel with water,dry it with cloth, dry
it up in the shade after washing.

4. Attach the front panel.

• Insert the front panel into the grooves of the unit (3 places).

• Attach the string to the right, inner-side of the front grille.
• Close the panel slowly.

CAUTION

• Don’t touch the metal parts of the indoor unit. If you touch those parts, this may cause an injury.

• When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully.

• When removing or attaching the front panel, support the panel securely with hand to prevent it from falling.

• For cleaning, do not use hot water above 40°C, benzine, gasoline, thinner, nor other volatile oils, polishing compound,
scrubbing brushes, nor other hand stuff.

• After cleaning, make sure that the front panel is securely fixed.

2 Filters

1. Open the front panel.

2. Remove the air filter.

• Press the claws on the right and left of the air filter down slightly, then
pull upward.

3. Take off the Air-Purifying Filter.

• Hold the tabs of the frame, and remove the claws in 4 places.

String

String

Place front 
panel in 
grooves.

7

Sayfa 12

Maintenance

4.

Clean or replace each filter.

See figure.

5.

Set the air filter and Air-Purifying Filter as they were and 
close the front panel. 

• Operation without air filters may result in troubles as dust will accumulate
inside the indoor unit.

6.

Wash the air filters with water or clean them with vacuum
cleaner.

•

If the dust does not come off easily, wash them with neutral detergent
thinned with lukewarm water, then dry them up in the shade.

• It is recommended to clean the air filters every  week.

Air-Purifying Filter
3

The Air-Purifying Filter can be renewed by washing it with water
once every 6 months. We recommend replacing it once every 3 years.

●Maintenance

Vacuum dusts, and soak in warm water or water for about 10 to 15 minutes if dirt is heavy.
2.

1.

3.
Do not remove filter from frame when washing with water.

4.
After washing, shake off remaining water and dry in the shade.

Since the material is made out of paper, do not wring out the filter when removing water from it.

●Replacement

Remove the tabs on the filter frame and replace with a new filter.

• Dispose of the old filter as flammable waste.

• Note: Healthy filter is the optional accessory.

NOTE

• Operation with dirty filters:
(1) cannot deodorize the air.
(2) cannot clean the air.

(3) results in poor heating or cooling. (4) may cause odour.

Air-Purifying
Filter

Air filter

8

Sayfa 13

Maintenance

Check

Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded.

Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit.

Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.

• If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult
    the service shop if this is the case.

4 Before a long idle period

1. Operate the “FAN only” for several hours on a fine day to dry out the inside.

• Press “MODE” button and select “FAN” operation.

• Press “ON/OFF” button and start operation.

2. After operation stops, turn off the breaker for the room air conditioner.

3. Clean the air filters and set them again.

4. Take out batteries from the remote controller.

NOTE

• When a multi outdoor unit is connected, make sure the heating operation is not used at the other room befure you use the fan
operation.

Working temperature range

Indoor sideDB/WB(oC)
Outdoor sideDB/WB(oC)

Maximum cooling

32/23

Maximum heating

27/---

The operating temperature range (outdoor temperature) for cooling unit is -15℃~ 43℃;
for cooling and heating unit is -22℃~ 43℃.

9

43/26

 24/18

Sayfa 14

Operating guide

Working principle and special functions for cooling

Principle:

Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that
indoor ambient temperature decreased, its cooling capacity will increase or decrease by
outdoor ambient temperature.

Anti-freezing function:

If the unit is running in COOL mode and in low temperature, there will be frost formed on
the heat exchanger, when indoor heat exchanger temperature decreased below 0
, the
indoor unit microcomputer will stop compressor running and protect the unit.

Working principle and special functions for heating

Principle:

* Air conditioner absorbs heat from outdoor and transmits to indoor, in this way to increase
room temperature. This is the heat pump heating principle, its heating capacity will be
reduced due to outdoor temperature decrease.
* If outdoor temperature becomes very low, please operate with other heating equipments.

Defrosting:

*
When outdoor temperature is low but high humidity, after a long while running, frost will
form on outdoor unit, that will effect the heating effect, at this time, the auto defrosting
function will act, the heat running will stop for 8-10mins.
* During the auto defrosting, the fan motors of indoor unit and outdoor unit will stop.
* During the defrosting, the indoor indicator flashes, the outdoor unit may
emit  vapor, This is due to the defrosting, it isn't malfunction.
* After defrosting finished,the heating will recover automatically.

Anti-cool wind function:

In Heat mode, the following three kinds of status, if indoor heat exchanger hasn't achieve
certain temperature that indoor fan motor will not start, in this way to prevent blowing cool

wind (within 3mins):

1. Heat operation just startedup.
2. After Auto defrosting operation is finished.
3. Heating under low temperature.

The climate type of this unit is according to the nameplate.

℃

10

Sayfa 15

Operating guide

The temperature should not be set lower than
what you need. This would result to increase
energy cost. 

Clean the air filter every week for higher
efficiency.

Draw close curtains or close glass windows
when cooling to prevent heat load from sun
light which may cause more electricity cost.

To distribute cool air through out the roon,
adjust air flow direction as shown by the
arrows (see picture) to diffuse cool air.

Close window and door while operating the unit 
to prevent leakage of cooled air to save energy.

In case of ineffective ventilation,open the
window to ventilate the room air once in a 
while but not too long since cooled air will be
uselessly drained out.

11

Sayfa 16

Precautions

Check electrical system(voltage and frequency).
Use the proper power supply indicated on the 
unit to operate the airconditioner and only fuses
with specified capacity.Do not use pieces of wire
instead of fuse. 

Do not insert objects into the air inlet or outlet
when the airconditioner is running as it may
cause damage or personal injury .Also pay
special attention when children are around.

Do not channel the air flow directly at people,
especially infants,aged persons or patients.

Turn off the airconditioner if ,while running,
electricity interference occurs.If the unit is not
to be used for a long time,cut off the power
supply main switch.

Do not locate any obstacle against the air
flow direction of indoor and outdoor unit.
Inefficient performance or malfunction may re-
sult.

Do not locate a heater or any other heat source
close to the unit.The heat may deform plastic
parts.

12

Sayfa 17

Checking before contact the service man

Check the  following before contact the service man.You may find the solution to your problems.
After checking,if it still does not operate, please contact your local dealer.

CAUSES
PROBLEM

NO  operation

The air conditioner runs
but does not cool enough.

Vapor or mist fume coming
out of the unit while runing.

Inoperative
remote control.

Check if eletrical wire is damaged & check if breaker
switch is still on.
Check if the power supply is in order.

Check if the timer switch is on or not.

Check if the preset temperature is too high.

Check if the sunlight shines directly into the room.

Check if the door and window are opened.

Check if there is anything obstructing the air discharge

Check if the exhaust fan still operates
Check if the air filter is dirty or clogged.

Hot air in the room mixes with cool air.This causes smoke fume.

Loosened or disconnected wire between the unit and the
display.

Check if the batteries are inserted in correct directions.
Check if the batteries are exhaused or not.

13

Sayfa 18

Installation of indoor unit

SELECTION OF INSTALLATION LOCATION.

Such a place where cool air can be distributed 

●

throughout the room.

Such a place where condensation water is easily 

●

drained out.

Such a place that can handle the weight of indoor unit. 

●

Such a place which has easy access for maintenance.

●

●

The appliance shall not be installed in the laundry.

THERE ARE 2 STYLES OF INSTALLATION.

●

CEILING TYPE

●

FLOOR TYPE

Each type is similar to the other as follows;

  Indoor unit

The indoor unit should be sited in a place where:

1) the restrictions on installation specified in the indoor
unit  installation drawings are met.
2) both air intake and exhaust have clear paths met.

3) the unit is not in the path of direct sunlight.

4) the unit is away from the source of heat or steam.

5) there is no source of machine oil vapour (this may
shorten indoor unit life).
6) cool(warm) air is circulated throughout the room.

7) the unit is away from electronic ignition type fluorwscent lamps

(inverter or rapid stert type) as they may shorten the  remote
controller  range.

8) the unit is at least 1 metre away from any television or  radio

set(unit may cause  interference with the picture or sound).

CAUTIONS FOR INSTALLATION WHERE

A

IR CONDITIONER TROUBLEIS LIABLE

TOOCCUR.

Where there is toomuch of oil area.
●

Where it is acid base   area.
●

Where there is irregular electrical supply.
●

Indoor Unit Installation Drawings

The indoor unit may be mounted in any of the three styles shown here.

Console unit shall be installed on the ground or the position where is 0.3m from the floor.  

Exposed

Half conceated
Concealed

Mounting plate

Molding

Grid(field supply)

Floor lnstallation
Wall Installation

Location for securing the installation panel.

700

200

120
220

644

120
220

570

600

170

30

160

30

Schematic drawing of hooks:

200mm

INSTALLATION
PAPER PLANK

70mm
or more

50mm
or more

50mm
or more

14

Sayfa 19

Installation of indoor unit

Refrigerant piping

1)Drill a hole ( 55mm in diameter ) in  the spot indicated by the     symbol in the illustration as below .
2)The location of the hole is different depending on which side of the pipe is taken out .
3)For piping ,see Connecting the refrigerant pipe ,under Indoor Unit Installation(1).

4)Allow space around the pipe for a easier indoor unit pipe connection.

(Unit : mm)

Wall

45

60

g
nipip
 
m
o
tt
o
b
 t
h
gi
R
g
nipip
 
m
o
tt
o
b
 tf
e
L

75

75

45

75

75

Left back piping

Right back piping
Left/right piping

45

45

45

CAUTION

Min.allowable length

The suggested shortest pipe length is 2.5m,in order to avoid noise from the outdoor unit and vibration.
(Mechanical noise and vibration may occur depending on how the unit is installed and the environment in which it is
used.)

See the installation manual for the outdoor unit for the maximum pipe length.
For multi-connections ,see the installation manual for the multi-outdoor unit.

wall

350

Refrigerant pipe

45

75
Floor

15

Sayfa 20

Installation of indoor unit

Boring a wall hole and installing wall embedded pipe

For walls containing metal frame or metal board ,be sure to use a wall embedded
pipe and wall cover in the feed-through hole to prevent water leakage.

Be sure to caulk the gaps around the pipes with caulking material to prevent
water leakage.
1)Bore a feed-through hole of 55mm in the wall so it has a down slope toward the
outside.
2)Insert a wall pipe into the hole.
3)Insert a wall cover into wall pipe .
4)After completing refrigerant piping, wiring, and drain piping, caulk pipe hole gap

with putty.

Drain piping

1)Use commercial regid polyvinyl chloride pipe
general VP 20 pipe, outer diameter 26mm, inner diameter 20mm
for the drain pipe.
2)The drain hose (outer diameter 18mm at connecting end, 220mm long)is supplied with the indoor unit. Prepare the
drain pipe picture below position.
3)The drain pipe should be inclined downward so that water will flow smoothly without any accumulation.(Should not
be trap.)
4)Insert the drain hose to this depth so it won’t be pulled out of the drain pipe.
5)Insulate the indoor drain pipe with 10mm or more of insulation material to prevent condensation.

6)Remove the air filters and pour some water into the drain pan to check the water flows smoothly.

Inside 
Outside

Caulking
Wall embedded pipe 
(field supply)

Φ55

Wall hole cover

Wall embedded pipe 
(field supply)

150

Must be no trap

Do not touch water

100

100
Drain hose

50mm
or more

Vinyl chloride
drain pipe

Reducer

16

Sayfa 21

Installation of indoor unit

Installing indoor unit

1.Preparation

Open the front panel, remove the 4 screws and dis-
mount the front grille while pulling it forward.

Follow the arrows to disengage the clasps on the 
front case to remove it.

Follow the procedure below when removing the slit

portions.

For Moldings

 Remove the pillars. (Remove the slit portions on the

bottom frame using nippers.)

For Side Piping

Remove the pillars.
1)Remove the 7screws.
2)Remove the upper casing (2 tabs).
3)Remove the left and right casings (2 tabs on each
side ).
4)Remove the slit portions on the bottom frame and
casings using nippers .
5)Return by following the steps in reverse order(3>2>

1).

2.Installation

Secure using 6 screws for floor installations.(Do not forget to secure to the rear wall.)
For wall installations, secure the  mounting plate using 5 screws and the indoor unit using 4 screws.

3 tabs

Casing

Front 
grille

Front panel

Remove
front grille

Open the front panel

Remove 4 screws

2)Upper casing

3)Side 
casings

3)Side
casings

Remove the pillar
Remove 7 screws

Bottom frame

Casing

Casing

Remove the pillar

Remove the pillar

17

Sayfa 22

Installation of indoor unit

The mounting plate should be installed on a wall which can support the weight of the indoor unit.

1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring

points on the wall.

2) Secure the mounting plate to the wall with screws.

Floor Installation
Wall Installation

Casing

200mm

Molding

6screws

6screws

3) Once refrigerant piping and drain piping connections are complete, fill in the gap of the through hole with putty. A gap

can lead to condensation on the refrigerant pipe, and drain pipe, and the entry of insects into the pipes.

4) Attach the front panel and front grille in their original positions once all connections are complete.

Flaring the pipe end

1)Cut the pipe end with a pipe cutter.

2)Remove burrs with the cut surface facing downward so that the chips do not enter the pipe.

3)Fit the flare nut on the pipe.

4)Flare the pipe.

5)Check that the flaring is properly made.

WARNING
1)
Do not use mineral oil on flared part.

2)
Prevent mineral oil from getting into the system as this would reduce the lifetime of the units.

3)
Never use piping which had been used for previous installations. Only use parts which are delivered with the unit.

4)
Do never install a drier to this R32 unit in order to guarantee its lifetime.

5)
The drying material may dissolve and damage the system.

6)
Incomplete flaring may cause refrigerant gas leakage.

The pipe end must
be evenly flared in 
a perfect circle

Flare’s inner 
surface must
be scratch-free

Flaring
Set exactly at the position shown below

Flare tool for R32

Conventional flare tool

A

Clutch-type
Clutch-type
(Rigid-type)

Wing-nut type
(lmperial-type)

Die

Cut exactly
at right
angles

Make sure that the
flare nut is fitted

Renove

A
0-0.5mm
1.0-1.5mm
1.5-2.0mm

burrs

18

Sayfa 23

Installation of indoor unit

Connecting the refrigerant pipe

1) Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leaks.

Coat here with refrigeration oil

2) Align the centres of both flares and tighten the flares and tighten the flare nuts 3 or 4 turns by hand.

Then tighten them fully with the torque wrenches.

3) To prevent gas leakage, apply refrigeration oil on both inner and outer surfaces in the flare. (Use refrigeration oil for

R32.)

Flare nut tightening torque

Gas side

09K/12K
18K
09K/12K/18K

3/8 inch
1/2 inch
1/4 inch

31-35 N.m
50-55 N.m
15-20 N.m

Caution on piping handling

1)Protect the open end of the pipe against dust and moisture.

2)All pipe bends should be as gentle as possible. Use a pipe bender for

bending.

(Bending radius should be 30 to 40mm or larger.)

Selection of copper and heat insulation materials

When using commercial copper pipes and fittings, observe the

following:

1)Insulation material: Polyethylene foam

Heat transfer rate:0.041 to 0.052W/mK(0.035 to 0.045kca/(mh
Refrigerant gas pipe’s surface temperature reaches 110
max.

Choose heat insulation materials that will withstand this temperature.

2)Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below.

Gas side
Gas pipe thermal insulation
Liquid side
Liquid pipe
thermal insulation

18K
18K
09K/12K
09K/12K

O.D. 9.5mm
O.D. 12.7mm
O.D. 6.4mm
I.D. 12-15mm
I.D. 14-16mm
I.D. 8-10mm

Thickness 0.8mm
Thickness 10mm Min.

3)Use separate thermal insulation pipes for gas and liquid refrigerant pipes.

Open-end wrench (fixed)

Flare nut

Wrench

Connection pipe

Indoor unit tubing

Liquid side

Be sure to
place a cap.

If no flare cap is
available,cover 
the flare mouth 
with tape to keep
dirt or water out.

Inter-unit wiring

Gas pipe

Liquid pipe

Liquid pipe
insulation

Gas pipe
insulstion

Finising tape

19

Sayfa 24

Installation of indoor unit

Checking for gas leakage

1)Check for leakage of gas after air purging

2)See the sections on air purges and gas leak checks in

the installation manual for the outdoor unit.

Attaching the connection pipe

Attach the pipe after checking for gas leakage, described above.

1)Cut the insulated portion of the on-site piping, matching it up with the connecting portion.

2)Secure the slit on the refrigerant piping side with the butt joint on the auxiliary piping using the tape, making sure there

are no gaps.

3)Wrap the slit and butt joint with the included insulation sheet, making sure there are no gaps.

CAUTION

1)Insulate the joint of the pipes securely.

Incomplete insulation may lead to water leakage.

2)Push the pipe inside so it does not place undue force on the front grille.

Connecting the drain hose

Insert the supplied C drain hose into the socket

of the drain pan.

Fully insert the drain hose until it adheres to a

seat of the socket.

Check for leakage here
Apply soapy water and ch-
eck carefully for leaking gas.
wipe soapy water off after
the check is complete.

Refrigerant
pipe
Refrigerant
pipe

Refrigerant
pipe

Slit
Slit

Insulation sheet

Tape

Auxiliary pipe

Drain pan
Seal
Drain hose

Drain pan

Seal

20

Sayfa 25

Installation of indoor unit

Wiring

With a Multi indoor unit, install as described in the installation manual supplied with the Multi outdoor unit.

Live the sensor securing plate, remove the front metal plate cover, and connect the branch wiring to the terminal block.

1)Strip wire ends (15mm)

2)Mach wire colours with terminal numbers on indoor and outdoor unit’s terminal blocks and firmly screw wires to

the corresponding terminals.

3)Connect the earth wires to the corresponding terminals.

4)Pull wires to make sure that they are securely latches up, then retain wires with wire retainer.

Sensor securing plate

Firmly fix the wires with the
 terminal screws

Outdoor unit

N(1)
2
3
Terminal block

Shape wires so 
that the front metal 
plate cover will fit 
securely.

When wire length exceeds 10m,
use 2.0mmdiameter wires

Electrical 
component 
box

Indoor unit

Wire retainer

Firmly secure wire 
retainer so that 
wires sustain no 
external stress.

Use the specified wire type.

Front metal 
plate cover

Firmly fix the wires with the
 terminal screws

CAUTION

1)Do not use tapped wires, stranded wires, extensioncords, or starburst connections, as they may cause overheating,

electrical shock, or fire.

2)Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc, from

the terminal block.) Doing so may cause electric shock or fire.)

21

Sayfa 26

Refrigerant piping work

1 Select copper pipes for gas and liquid as informed in specific table(see the pipe table below)

2   For dust and moisture protection, before assembly of the pipe and its insulation,both end of the

pipe must be covered.

3   Avoid pipe bending as much as possible.If it is necessary, the bending radius must be more than

3cm. or 4cm.

4   The connection between an indoor unit and an outdoor unit.

Unscrew the flare nut for releasing pressure gas in the indoor unit.If there is no high pressure gas 

blowing out, it is the signal of a leaking indoor unit.

Fit the flare nut to the liquid pipe.Flare the pipe's end with flare tool.

Tighten both flare nuts into gas pipe and liquid pipe at the indoor unit with two holding spanners.

Gas pipe and liquid pipe insulation depends upon

copper pipe size and the insulation thickness = 3/8"

GAS PIPE TABLE

MODEL
PIPE SIZE

09K

3/8"

3/8"
12K

18K

1/2"

LIQUID PIPE TABLE

MODEL
PIPE SIZE

09K

1/4"

1/4"
12K

1/4"

18K

Connecting
Wire

Liquid
Pipe

Gas Pipe

Dia. Drain Pipe 1/2"
Piping Tape

22

Sayfa 27

Routine check after installation

Check after installation

Items to be checked

Has it been fixed firmly?

Have you done the refrigerant leakage test?

Is heat insulation sufficient?

Does the unit drain well?

Is the voltage in accordance with the rated
voltage marked on the nameplate?

Is the electrical wiring and piping connection
installed correctly and securely?

Has the unit been connected to a secure earth
connection?

Is the power cord specified?

Has the inlet and outlet been covered?

Has the length of connection pipes and the
refrigerant charge been record?

Is the inlet and outlet of piping hole been 
covered?
capacity or waster eletricity.
It may cause insufficient cooling (heating) 

Possible malfunction
Situation

The unit may drop,shake or emit noise.

It may cause insufficient refrigerating capacity.

It may cause condensation and dripping.

It may cause condensation and dripping.

It may cause electric malfunction or damage the
part.

It may cause electric malfunction or damage the
part.

It may cause electrical leakage.

It may cause electric malfunction or damage the
part.

It may cause insufficient refrigerating capacity.

The refrigerating capacity is not accurate

23

Sayfa 28

Part names and their functions

INDOOR UNIT

3
1
2

8

11

9

12
10

13

7

14

4

15

2

CAUTION

Before opening the front panel, be sure to 
stop the operation and turn the breaker OFF.

Air outlet selection switch

5

This setting blows air from 
•
upper outlet only.

Do not touch the metal parts on the inside 
of the indoor unit, as it may result in injury.

16

This setting automatically 
decides a blow pattern 
depending on mode and 
•

1. Air-Purifying Filter:

conditions.

•

 This setting is recommended. 

• These filters are attached to the inside

of the air filters.
Note: Healthy filter is the optional accessory.

•

 The unit is shipped from the 

Air outlet
3. Display
4. Front panel
5. Louvers (vertical blades)
• The louvers are inside of the air outlet.
6. Air inlet
7. Air filter
8. Flap (horizontal blade)
9. Cool mode lamp
10. Heat mode lamp
11. Dry mode lamp

2.

factory with this setting.

Opening the Front Panel

Indoor unit 
wiring terminal

N(1)
2

3

blue
black
yellow-
green

brown

12. Run lamp
13. LED display

14. Indoor Unit ON/OFF switch:
•

Push this switch once to start operation.
Push once again to stop it.

• The operation mode refers to the following table.

Model
Mode Temperature

setting
Air flow rate

COOLING

25℃

AUTO

AUTO

ONLY

HEAT
PUMP

25℃

AUTO

AUTO

• This switch is useful when the remote controller
is missing.

15.Signal receiver:
• It receives signals from the remote controller.
•

When the unit receives a signal, you will hear
a short beep.

•

Settings changed.....beep

Air outlet selection switch
16.
Room temperature sensor:
17.
It senses the air temperature around the unit.
•

24

6

17

Sayfa 29

How to use the remote control to operate the unit

Remote Controller Description

1

2

3

5
4

6

7

9
8

11
10

13
12

14

16
WiFi

15

Press it to start or stop operation.
ON/OFF

1

-

 : Press it to decrease temperature

2

 setting.

+

3

: Press it to increase temperature

 setting.

MODE

4

Press it to select operation mode
(AUTO/COOL/DRY/FAN/HEAT).

FAN

5

Press it to set fan speed.

SWING

6

Press it set swing angle.

I FEEL

7

/

8

Press it to set HEALTH or AIR function.

SLEEP

9

TEMP

10

QUIET

11

Press it to set

QUIET function.

CLOCK

12

Press it set clock.

T-ON T-OFF

13

Press it to set auto-off/auto-ontimer.

TURBO

14

LIGHT

15

Press it to turn on/off the light.

WiFi

16

25

Sayfa 30

How to use the remote control to operate the unit

Remote Controller Description

Note:

● This is a general use remote controller, it could be used for the air conditioners with multifunction; For some 
function, which the model doesn't have, if press the corresponding button on the remote controller that the unit
will keep the original running status.

1

ON/OFF :

Press this button to turn on the unit .Press this button again to turn off the unit.

2

Press this button to decrease set temperature. Holding it down above 2 seconds rapidly decreases 
set temperature. In AUTO mode, set temperature is not adjustable. 

+ :

3

Press this button to increase set temperature.Holding it down above 2 seconds rapidly increases set 

temperature. In AUTO mode, set temperature is not adjustable. 

4

MODE :

Each time you press this button,a mode is selected in a sequence that goes from AUTO, COOL,DRY, 

FAN,and HEAT

*, as the following:

AUTO
COOL
DRY
FAN
HEAT *

*Note:Only for models with heating function.

After energization, AUTO mode is  defaulted. In AUTO mode, the set temperature will not be displayed 
on the LED of the indoor, and the unit will  automatically select the suitable operation mode in 
accordance with the room temperature to make indoor room comfortable.

5

This button is used for setting Fan Speed in the sequence that goes from AUTO,
,
FAN :

to
then back to Auto.
,

Auto

Medium speed
Low-Medium speed
Low speed

High speed
Medium-High speed

●

X-FAN function:Hold fan speed button for 2s in COOL or DRY mode, the icon “      ” is displayed 
and the indoor fan will continue operation for a few minutes in order to dry the indoor unit even 
though you have turned off the unit. After energization, X-FAN OFF is defaulted. X-FAN is not 
available in AUTO, FAN or HEAT mode.   

This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is 
stopped to avoid mould. 

●

Having set X-FAN function on: After turning off the unit by pressing ON/OFF button indoor fan will 
continue running for a few minutes. at low speed. In this period, Hold fan speed button for 2s to 
stop indoor fan directly.   

●

Having set X-FAN function off: After turning off the unit by pressing ON/OFF button, the complete 
unit will be off directly.

26

,
,

Sayfa 31

How to use the remote control to operate the unit

6
Press this button to set up &down swing angle, which circularly changes as below:

SWING:

This remote controller is universal . If any command        ,           or          is sent out, the unit will carry

 out the command as

indicates the guide louver swings as:

I FEEL:

7

Press this button to turn on I FEEL function. The unit automatically adjust temperature according to
the sensed temperature. Press this button again to cancel I FEEL function. 
When I FEEL function is turned on, the remote controller should be put within the area where indoor unit 
can receive the signal sent by the remote controller. 

/
8

Press this button to achieve the on and off of health and scavenging functions in operation status.

Press this button for the first time to start scavenging function;
LCD displays“     ”. Press the button for the second time to start health and scavenging functions 
simultaneously; LCD displays“     ” and “     ” . Press this button for the third time to  quit health

and scavenging functions simultaneously. Press the button for the fourth time to start  health 
function; LCD display “      ” . Press this button again to repeat the operation above.
NOTE: This function is applicable to partial of models.

SLEEP:
9
Press this button, can select Sleep 1 (            ), Sleep 2 (           ),Sleep 3 (           ) and cancel the Sleep,
circulate between these, after electrified, Sleep Cancel is defaulted.
Sleep 1 is Sleep mode 1, in Cool mode: sleep status after run for one hour, the main
unit setting temperature will increase 1

●

●
℃,setting temperature increased 2℃, the unit will run at this
setting temperature; In Heat mode: sleep status after run for one hour, the setting temperature will
decrease 1 ℃, 2 hours, setting temperature will decrease 2℃, then the unit will run at this setting
temperature.

●Sleep 2 is sleep mode 2, that is air conditioner will run according to the presetting a group of sleep temperature curve.

Sleep 3- the sleep curve setting under Sleep mode by DIY:
(1) Under Sleep 3 mode, press "Turbo" button for a long time, remote control enters into user individuation sleep
setting status, at this time, the time of remote control will display "1 hour ", the setting temperature "88" will

●

display the corresponding temperature of last setting sleep curve and blink (The first entering will display
according to the initial curve setting value of original factory);

(2) Adjust "+" and "-" button, could change the corresponding setting temperature, after adjusted, press
"Turbo "button for confirmation;
(3) At this time, 1 hour will be automatically increased at the timer position on the remote control, (that are 

"2 hours " or "3 hours " or "8 hours "), the place of setting temperature "88" will display the 
corresponding temperature of last setting sleep curve and blink;

(4) Repeat the above step (2) ~(3) operation, until 8 hours temperature setting finished, sleep 
curve setting finished, at this time, the remote control will resume the original timer display;

temperature display will resume to original setting temperature.

●
Sleep3- the sleep curve setting under SLEEP mode by DIY could be inquired:

The user could accord to sleep curve setting method to inquire the presetting sleep curve, enter into user 
individuation sleep setting status, but do not change the temperature, press "Turbo" button directly for confirmation.
Note: In the above presetting or enquiry procedure, if continuously within10s, there is no button pressed, the
sleep curve setting within10s, there is no button pressed, the sleep curve setting status will be automatically
quit and resume to display the original displaying. In the presetting or enquiry procedure, press "ON/OFF"
button, "Mode" button, "Timer"button or "Sleep" button, the sleep curve setting or enquiry status will quit similarly.

OFF

27

Sayfa 32

How to use the remote control to operate the unit

10 TEMP:

Press this button, could select displaying the indoor setting temperature or indoor ambient
temperature.When the indoor unit firstly power on it will display the setting temperature,
if the temperature's displaying status is changed from other status to"    ",displays the
ambient temperature, 5s later or within 5s, it receives other remote control signal that will 
return to display the setting temperature. if the users haven't set up the temperature 
displaying status,that will display the setting temperature.

11 QUIET:

Press this button, the Quiet status is under the Auto Quiet mode (display "
" and "Auto" signal)
and Quiet mode (display "       " signal)  and Quiet OFF (there is no signal of "       " displayed),

      " signal), the
after powered on, the Quiet OFF is defaulted. Note: Under the Quiet mode (Display " 
fan speed is not available. 

12

CLOCK :

 
Press CLOCK button, blinking       . Within 5 seconds,pressing + or - button adjusts the present time.
Holding down either button above 2 seconds increases or decreases the time by 1 minute every 0.5 
second and then by 10 minutes every 0.5 second. During blinking after setting, press CLOCK button
again to confirm the setting,and then
 will be constantly displayed.

13

T-ON / T-OFF:

Press T-ON button to initiate the auto-ON timer. To cancel the auto-timer program, simply press this
button again.

After press of this button,

5 seconds,press + or - butt on to adjust the time value.Every press of either button changes the time
setting by 1minute. Holding down either button rapidly changes the time setting by 1 minute and then 
10 minutes.Within 5 Seconds after setting,press TIMER ON button to confirm. 

Press T-OFF button to initiate the auto-off timer. To cancel the auto-timer program, simply press the 

button again.TIMER OFF setting is the same as TIMER ON. 

14 TURBO:

Press this button to activate / deactivate the Turbo function which enables the unit to reach the preset
temperature in the shortest time. In COOL mode, the unit will blow strong cooling air at super high fan 

speed. In HEAT mode, the unit will blow strong heating air at super high fan speed. 

15 LIGHT:

Press LIGHT button to turn on the display's light and press this button again to turn off  the display 's 
light. If the light is turned on ,        is  displayed. If the light is turned off,       disappears. 

16
WiFi:

Press " WiFi "  button to turn on WiFi function,   " WiFi " icon will be displayed on the remote controller; 
Hold " WiFi "  button for 5s to turn off WiFi function and " WiFi " icon will disappear.(This function is only 
available for some models.)
Under off status, press " MODE " and " WiFi " buttons simultaneously for 1s, WiFi module will restore 
factory settings.

●This function is only available for some models.

17 Combination of "+" and "-" buttons: About lock

Press " + " and "-" buttons simultaneously to lock or unlock the keypad. If the remote controller is 
locked,        is displayed. In this case, pressing any button,     blinks three times.

0
.     s
k
nilb
" 
N
O
" 
d
n
a
 s
r
a
e
p
p
a
sid
  
0:00 is displayed for ON time setting.Within

28

Sayfa 33

How to use the remote control to operate the unit

Combination of "MODE " and "-" buttons:
18
About switch between Fahrenheit and centigrade

At unit OFF, press "MODE"and " - " buttons simultaneously to switch between      and     . 
℃
℉

Combination of " TEMP " and "CLOCK" buttons  :  About Energy-saving Function
19

Press "TEMP" and "CLOCK" simultaneously in COOL mode to start energy-saving function.
Nixie tube on the remote controller displays "SE". Repeat the operation to quit the function.  

Combination of " TEMP " and "CLOCK" buttons : About 8℃Heating Function
20

8℃Heating Function
.
Nixie tube on the remote controller displays "     " and a selected temperature of " 8℃"
(46     if Fahrenheit is adopted). Repeat the operation to quit the function.

Press "TEMP" and "CLOCK" simultaneously in HEAT mode to start 

℉

About Back-lighting Function
21

The unit lights for 4s when energizing for the first time, and 3s for later press.

Replacement of Batteries

1.Remove the battery cover plate from the rear of the remote controller.

(As shown in the figure)

2.Take out the old batteries. 

3.Insert two new AAA1.5V dry batteries, and pay attention to the polarity. 

4. Reinstall the battery cover plate. 

★

Notes:

●

When replacing the batteries, do not use old or different types of batteries,

otherwise, it may cause malfunction.

●

If the remote controller will not be used for a long time, please 

remove batteries to prevent batteries from leaking. 

●
●
●

The operation should be performed in its receiving range.

It should be kept 1m away from the TV set or stereo sound sets.

If the remote controller does not operate normally, please take the 

batteries out and reinsert them after 30 seconds.If it still can't operate properly,   

replace the batteries.

29

Sketch map for 
replacing batteries

Sayfa 34

Configuration of connection pipe

1. Standard length of connection pipe
    ● 5m, 7.5m, 8m.

2.Min. length of connection pipe is 3m.

3.Max. length of connection pipe.

Sheet 1 Max. length of connection pipe 
Unit: m

Max. length 
of connec-
tion pipe

Max. length
of connec-
tion pipe

Cooling 
capacity

Cooling 
capacity

5000Btu/h
(1465W)

24000Btu/h
(7032W)

15
25

7000Btu/h
(2051W)

28000Btu/h
(8204W)

15
30

9000Btu/h
(2637W)

36000Btu/h
(10548W)

15
30

12000Btu/h
(3516W)

42000Btu/h
(12306W)

20
30

18000Btu/h
(5274W)

48000Btu/h
(14064W)

25
30

4. The additional refrigerant oil and refrigerant charging required after prolonging  
    connection pipe
    ● After the length of connection pipe is prolonged for 10m at the basis of 
       standard length, you should add 5ml of refrigerant oil for each additional 5m 
       of connection pipe.
    ●

 The calculation method of additional refrigerant charging amount (on the basis 
       of liquid pipe):
         Additional refrigerant charging amount = prolonged length of liquid pipe × 
         additional refrigerant charging amount per meter

Basing on the length of standard pipe, add refrigerant according to the 
requirement as shown in the table. The additional refrigerant charging amount 
       per meter is different according to the diameter of liquid pipe. See Sheet 2.

●

30

Sayfa 35

Configuration of connection pipe

Sheet 2. Additional refrigerant charging amount for R32

Piping size

Indoor unit throttle
Outdoor unit throttle

Cooling only,
Cooling only
cooling and heating
(g / m)

Liquid pipe
Gas pipe

(g / m)
(g / m)

1/4''

3/8'' or 1/2''

16

1/4'' or 3/8''

5/8'' or 3/4''

40

1/2''

3/4'' or 7/8''

80

5/8''

1'' or 1 1/4''

136

_

3/4''

200
200

7/8''
_

280
280

Note: The additional refrigerant charging amount in Sheet 2 is recommended

value, not compulsory.

31

cooling and

heating

12

16

12

40

24

96

48

96

200

280

Sayfa 36

Safety operation of flammable refrigerant

Qualification requirement for installation and maintenance man

All the work men who are engaging in the refrigeration system should bear the
valid certification awarded by the authoritative organization and the qualification
for dealing with the refrigeration system recognized by this industry. If it needs
other technician to maintain and repair the appliance, they should be supervised
by the person who bears the qualification for using the flammable refrigerant.
It can only be repaired by the method suggested by the equipment’s manufacturer.

Installation notes

The air conditioner is not allowed to use in a room that has running fire (such as fire
source, working coal gas ware, operating heater).

It is not allowed to drill hole or burn the connection pipe.
The air conditioner must be installed in a room that is larger than the minimum room
area. The minimum room area is shown on the nameplate or following table a.
Leak test is a must after installation.

table a - Minimum room area ( m  )
2

Charge amount (kg) ≤1.2 1.3 1.4
1.5
1.6
1.7
1.8
1.9
2
2.1
2.2
2.3
2.4
2.5

floor location

/
14.5 16.8 19.3 22 24.8 27.8 31 34.3 37.8 41.5 45.4 49.4 53.6

Minimum

room

/

window mounted

5.2 6.1
7
7.9
8.9
10 11.2 12.4 13.6
15
16.3 17.8 19.3

2
area( m  )

wall mounted

/

1.6 1.9
2.1
2.4
2.8
3.1
3.4
3.8
4.2
4.6
5
5.5
6

ceiling mounted

/

1.1 1.3
1.4
1.6
1.8
2.1
2.3
2.6
2.8
3.1
3.4
3.7
4

Maintenance notes

Check whether the maintenance area or the room area meet the requirement of the

nameplate.
- It’s only allowed to be operated in the rooms that meet the requirement of the

nameplate.

Check whether the maintenance area is well-ventilated.

- The continuous ventilation status should be kept during the operation process.
Check whether there is fire source or potential fire source in the maintenance area.

- The naked flame is prohibited in the maintenance area; and the “no smoking”

warning board should be hanged.

Check whether the appliance mark is in good condition.

- Replace the vague or damaged warning mark.

Welding

If you should cut or weld the refrigerant system pipes in the process of maintaining, 
please follow the steps as below:

32

Sayfa 37

Safety operation of flammable refrigerant

a. Shut down the unit and cut power supply
b. Eliminate the refrigerant
c. Vacuuming
d. Clean it with N2 gas
e. Cutting or welding
f. Carry back to the service spot for welding

The refrigerant should be recycled into the specialized storage tank.

Make sure that there isn’t any naked flame near the outlet of the vacuum pump
and it’s well-ventilated.

Filling the refrigerant

Use the refrigerant filling appliances specialized for R32. Make sure that different

kinds of refrigerant won’t contaminate with each other.

The refrigerant tank should be kept upright at the time of filling refrigerant.

Stick the label on the system after filling is finished (or haven’t finished).
Don’t overfilling.

After filling is finished, please do the leakage detection before test running; another

time of leak detection should be done when it’s removed.

Safety instructions for transportation and storage

Please use the flammable gas detector to check before unload and open the container.

No fire source and smoking.
According to the local rules and laws.

33

Sayfa 38

Pipe preparation

1. PIPE & ELECTRICAL WIRE CUTTING

Use cutting tools easily found in the market.
Measure precisely both outer & inner pipe.
Provide a little bit longer pipe than the measurement.
Wire must be 1.5 m. longer than the refrigerant tube. 

2. REAMING

Clean inside  of the inner refrigerant tube.
While reaming, the tube end must be on the top of  the
reamer to prevent any dust going back into the tube.

3. FLARING THE PIPE END

Flare both ends of the pipe with flaring kit by fitting the
flare nut on the pipe before flaring.Set the die on the 
pipe so that pipe end is 0.5 mm. above top of the die.
Check if the pipe end is even and pertectly round.

4. WIRE CONNECTION AND TAPE COVERING

(see the picture on the right side)

Cutting Tool
Right
Wrong

Sloped Cut Rough Cut

Refrigerant Tube

Reamer

Up side

down position

0.5 mm.

Flare Kit

Refrigerant Tube

Uneven
Slope

Cracked
Poor skin
Uneven
Thickness

30-40 mm
Low Pressure Refrigerant Tube

Connecting 
Wire

High Prseeure 
Refrigerant Tube

To indoor Unit
To Outdoor Unit

34

Sayfa 39

Specialist’s Manual

 The following checks shall be applied to instal- 

lations using flammable refrigerants:
– the charge size is in accordance with the room size
within which the refrigerant containing parts are in- 
stalled;
– the ventilation machinery and outlets are operat-
ing adequately and are not obstructed;

– if an indirect refrigerating circuit is being used, the

secondary circuit shall be checked for the presence 
of refrigerant;
– marking to the equipment continues to be visible
and legible. Markings and signs that are illegible shall 
be corrected;
– refrigeration pipe or components are installed in a
position where they are unlikely to be exposed to any 
substance which may corrode refrigerant contain-
ting equipment or any associated parts, appropriate 
fire extinguishing equipment shall be available to 
hand. Have a dry powder or CO2 fire extinguisher 

ing components, unless the components are const-
ructed of materials which are inherently resistant to 
being corroded or are suitably protected against be- 
ing so corroded.

 Repair and maintenance to electrical compo-

nents shall include initial safety checks and com- 
ponent inspection procedures. If a fault exists 
that could compromise safety, then no electrical 
supply shall be connected to the circuit until it 
is satisfactorily dealt with. If the fault cannot 
be corrected immediately but it is necessary 
to continue operation, an adequate temporary 
solution shall be used. This shall be reported 
to the owner of the equipment so all parties are 

advised.
 Initial safety checks shall include:

– that capacitors are discharged: this shall be done
in a safe manner to avoid possibility of sparking;
– that no live electrical components and wiring are
exposed while charging, recovering or purging the 
system;
– that there is continuity of earth bonding.
 Checks to the area

Prior to beginning work on systems containing flamm- 

able refrigerants, safety checks are necessary to 
ensure that the risk of ignition is minimised. For 
repair to the refrigerating system, DD.3.3 to DD.3.7
shall be completed prior to conducting work on the 

system.
 Work procedure

Work shall be undertaken under a controlled 
procedure so as to minimise the risk of a flammable 
gas or vapour being present while the work is being 
performed.

 General work area

All maintenance staff and others working in the 
local area shall be instructed on the nature of work 
being carried out. Work in confined spaces shall be 
avoided.
 Checking for presence of refrigerant

The area shall be checked with an appropriate refri- 
gerant detector prior to and during work, to ensure 
the technician is aware of potentially toxic or flamm- 
able atmospheres. Ensure that the leak detection 
equipment being used is suitable for use with all app- 
licable refrigerants, i.e. non-sparking, adequately seal- 
ed or intrinsically safe.
 Presence of fire extinguisher

If any hot work is to be conducted on the refrigera-

adjacent to the charging area.
 No ignition sources

No person carrying out work in relation to a refriger-
ating system which involves exposing any pipe
work shall use any sources of ignition in such a
manner that it may lead to the risk of fire or
explosion. All possible ignition sources, including
cigarette smoking, should be kept sufficiently far
away from the site of installation, repairing, remov-
ing and disposal, during which refrigerant can
possibly be released to the surrounding space.

Prior to work taking place, the area around the
equipment is to be surveyed to make sure that
there are no flammable hazards or ignition risks.
''No Smoking'' signs shall be displayed.
 Ventilated area

Ensure that the area is in the open or that it is ad- 
equately ventilated before breaking into the system 
or conducting any hot work. A degree of ventilation 
shall continue during the period that the work is carri- 
ed out. The ventilation should safely disperse any re- 
leased refrigerant and preferably expel it externally 
into the atmosphere.
 Checks to the refrigeration equipment

Where electrical components are being changed, 

they shall be fit for the purpose and to the correct 

specification. At all times the manufacturer's mainte-
nance and service guidelines shall be followed. If in 
doubt,consult the manufacturer's technical depart-

ment for assistance.
The following checks shall be applied to installa-
tions using flammable refrigerants:

35

Sayfa 40

Specialist’s Manual

- the actual refrigerant charge is in accordance with 
the room size within which the refrigerant contain-
ing parts are installed;
- the ventilation machinery and outlets are operat-
ing adequately and are not obstructed;
- if an indirect refrigerating circuit is being used,the 
secondary circuit shall be checked for the presence 
of refrigerant;
- marking to the equipment continues to be visible 
and legible. Markings and signs that are illegible 
shall be corrected;
- refrigeration pipe or components are installed in a 
position where they are unlikely to be exposed to 
any substance which may corrode refrigerant 
containing components, unless the components
are constructed of materials which are inherently 
resistant to being corroded or are suitably protect-
ed against being so corroded.

 Checks to electrical devices

Repair and maintenance to electrical components
shall include initial safety checks and component
inspection procedures. If a fault exists that could
compromise safety,then no electrical supply shall
be connected to the circuit until it is satisfactorily
dealt with. If the fault cannot be corrected immedi-
ately but it is necessary to continue operation, an
adequate temporary solution shall be used. This
shall be reported to the owner of the equipment so
all parties are advised.

Initial safety checks shall include:
- that capacitors are discharged: this shall be done     
in a safe manner to avoid possibility of sparking;
- that no live electrical components and wiring are
exposed while charging, recovering or purging the
system;
- that there is continuity of earth bonding.

 Repairs to sealed components

During repairs to sealed components, all electrical
supplies shall be disconnected from the equipment
being worked upon prior to any removal of sealed
covers, etc. If it is absolutely necessary to have an
electrical supply to equipment during servicing, then
a permanently operating form of leak detection shall
be located at the most critical point to warn of a
potentially hazardous situation.

Particular attention shall be paid to the following to

ensure that by working on electrical components, the 
casing is not altered in such a way that the level of
protection is affected. This shall include damage to
cables, excessive number of connections, terminals
not made to original specification, damage to seals,

incorrect fitting of glands, etc.
–

Ensure that the apparatus is mounted securely.
 Ensure that seals or sealing materials have not de- 

–

graded to the point that they no longer serve the pur- 
pose of preventing the ingress of flammable atmos- 
pheres. Replacement parts shall be in accordance 
with the manufacturer’s specifications.
NOTE:The use of silicon sealant can inhibit the 
effectiveness of some types of leak detection equi- 
pment. Intrinsically safe components do not have to 
be isolated prior to working on them.
 Repair to intrinsically safe components

Do not apply any permanent inductive or capaci-
tance loads to the circuit without ensuring that this 
will not exceed the permissible voltage and current 

        
permitted for the equipment in use.
Intrinsically safe components are the only types that 
can be worked on while live in the presence of a fl- 
ammable atmosphere. The test apparatus shall be 
at the correct rating.
Replace components only with parts specified by the 
manufacturer. Other parts may result in the ignition 
of refrigerant in the atmosphere from a leak.
 Cabling

Check that cabling will not be subject to wear, cor- 
rosion, excessive pressure, vibration, sharp edges 

or any other adverse environmental effects. The 
check shall also take into account the effects of 
aging or continual vibration from sources such as 
    compressors or fans.

 Detection of flammable refrigerants

Under no circumstances shall potential sources of 
ignition be used in the searching for or detection of 
refrigerant leaks. A halide torch (or any other detec- 
tor using a naked flame) shall not be used.

 Leak detection methods

The following leak detection methods are deemed 
acceptable for all refrigerant systems.
Electronic leak detectors may be used to detect re- 
frigerant leaks but, in the case of flammable refrige- 

rants, the sensitivity may not be adequate, or may 
need re-calibration. (Detection equipment shall be 
calibrated in a refrigerant-free area.) Ensure that the 
detector is not a potential source of ignition and is 

suitable for the refrigerant used. Leak detection equip- 
ment shall be set at a percentage of the LFL of the 
refrigerant and shall be calibrated to the refrigerant 
employed, and the appropriate percentage of gas 
(25% maximum) is confirmed.
Leak detection fluids are also suitable for use with 

36

Sayfa 41

Specialist’s Manual

most refrigerants but the use of detergents contain-
ing chlorine shall be avoided as the chlorine may 
react with the refrigerant and corrode the copper 

pipe-work.
If a leak is suspected, all naked flames shall be re- 
moved/extinguished.

If a leakage of refrigerant is found which requires 
brazing, all of the refrigerant shall be recovered 
from the system, or isolated (by means of shut off 
valves) in a part of the system remote from the 
leak. For appliances containing flammable refriger-
ants, oxygen free nitrogen (OFN) shall then be 
purged through the system both before and during 

the brazing process.

 Removal and evacuation

When breaking into the refrigerant circuit to make 
repairs - or for any other purpose - conventional pro- 
cedures shall be used. However, for flammable 
refrigerants it is important that best practice is 
followed since flammability is a consideration. The 
following procedure shall be adhered to:

remove refrigerant;
purge the circuit with inert gas;
 evacuate;

purge with inert gas;
open the circuit by cutting or brazing.

The refrigerant charge shall be recovered into the 
correct recovery cylinders. For appliances contain-
ing flammable refrigerants, the system shall be 
"flushed" with OFN to render the unit safe. This 
process may need to be repeated several times. 
Compressed air or oxygen shall not be used for 
purging refrigerant systems.
For appliances containing flammable refrigerants, 
flushing shall be achieved by breaking the vacuum 
in the system with OFN and continuing to fill until 
the working pressure is achieved, then venting to 
atmosphere, and finally pulling down to a vacuum. 
This process shall be repeated until no refrigerant 
is within the system. When the final OFN charge is 
used, the system shall be vented down to atmo-
spheric pressure to enable work to take place. 
This operation is absolutely vital if brazing opera-
tions on the pipe-work are to take place.
Ensure that the outlet for the vacuum pump is not 
close to any ignition sources and that ventilation is 
available.

 Charging procedures

In addition to conventional charging procedures, the 
following requirements shall be followed.
   Ensure that contamination of different refrigerants

does not occur when using charging equipment. 
Hoses or lines shall be as short as possible to 
minimise the amount of refrigerant contained in 
them.
   Cylinders shall be kept in an appropriate position

according to the instructions.

Ensure that the refrigerating system is earthed

prior to charging the system with refrigerant.

Label the system when charging is complete (if

not already).
   Extreme care shall be taken not to overfill the re-
frigerating system.
Prior to recharging the system, it shall be pres- 
sure-tested with the appropriate purging gas. The 
system shall be leak-tested on completion of charg- 
ing but prior to commissioning. A follow up leak test 
shall be carried out prior to leaving the site.
 Decommissioning

Before carrying out this procedure, it is essential that 
the technician is completely familiar with the equip- 
ment and all its detail. It is recommended good pr- 

actice that all refrigerants are recovered safely. 
Prior to the task being carried out, an oil and refri- 
gerant sample shall be taken in case analysis is re- 
quired prior to re-use of recovered refrigerant. It is 
essential that electrical power is available before 

the task is commenced.
a) Become familiar with the equipment and its opera- 
tion.

b)
c)
–

Isolate system electrically.

Before attempting the procedure, ensure that:
mechanical handling equipment is available, if re- 

quired, for handling refrigerant cylinders;

–

all personal protective equipment is available and

being used correctly;

–

the recovery process is supervised at all times by

a competent person;

–

recovery equipment and cylinders conform to the

appropriate standards.

d) Pump down refrigerant system, if possible.
e) If a vacuum is not possible, make a manifold so
that refrigerant can be removed from various parts 
of the system.

f)
before recovery takes place.

Make sure that cylinder is situated on the scales

g)
dance with manufacturer's instructions.
h)

 Start the recovery machine and operate in accor- 

Do not overfill cylinders. (No more than 80% vo- 

lume liquid charge).
i)

Do not exceed the maximum working pressure of

37

Sayfa 42

Specialist’s Manual

the cylinder, even temporarily.
j) When the cylinders have been filled correctly and 
If compressors or compressor oils are to be remov- 
ed, ensure that they have been evacuated to an ac- 
ceptable level to make certain that flammable refri- 
gerant does not remain within the lubricant. The ev- 
acuation process shall be carried out prior to re- 
turning the compressor to the suppliers. Only ele- 
ctric heating to the compressor body shall be em- 
ployed to accelerate this process. When oil is drain- 
ed from a system, it shall be carried out safely. 

the process completed, make sure that the cylinders 
and the equipment are removed from site promptly 
and all isolation valves on the equipment are closed 
off.
k) Recovered refrigerant shall not be charged into
another refrigerating system unless it has been clean-
ed and checked.
 Labelling

Equipment shall be labelled stating that it has been 
de-commissioned and emptied of refrigerant. The label 
shall be dated and signed. For appliances contain-
ing flammable refrigerants, ensure that there are la- 
bels on the equipment stating the equipment con- 
tains flammable refrigerant.
 Recovery

When removing refrigerant from a system, either 
for servicing or decommissioning, it is recommend-
ed good practice that all refrigerants are removed 
safely.
When transferring refrigerant into cylinders, ensure 
that only appropriate refrigerant recovery cylinders 
are employed. Ensure that the correct number of cy- 

linders for holding the total system charge is av- 
ailable. All cylinders to be used are designated for 
the recovered refrigerant and labelled for that refri- 
gerant (i.e. special cylinders for the recovery of refri- 
gerant). Cylinders shall be complete with pressure-re- 
lief valve and associated shut-off valves in good work- 
ing order. Empty recovery cylinders are evacuated 
and, if possible, cooled before recovery occurs.

The recovery equipment shall be in good working 
order with a set of instructions concerning the 
equipment that is at hand and shall be suitable for 
the recovery of all appropriate refrigerants includ-

ing, when applicable, flammable refrigerants. In ad- 

dition, a set of calibrated weighing scales shall be 
available and in good working order. Hoses shall be 
complete with leak-free disconnect couplings and 

in good condition. Before using the recovery mac- 

hine, check that it is in satisfactory working order, 
has been properly maintained and that any associ-
ated electrical components are sealed to prevent 
ignition in the event of a refrigerant release. Con- 
sult manufacturer if in doubt.
The recovered refrigerant shall be returned to the 
refrigerant supplier in the correct recovery cylinder, 
and the relevant waste transfer note arranged. Do 
not mix refrigerants in recovery units and especially 

not in cylinders.

 General

That the installation of pipe-work shall be kept to a
minimum.
That compliance with national gas regulations shall
be observed.
That mechanical connections made in accordance
with 22.118 shall be accessible for maintenance
purposes.

38

Sayfa 43

GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 
Tel: (+86-756) 8522218         
Fax: (+86-756) 8669426
E-mail: global@cn.gree.com
Web: www.gree.com

600005067372