Service_manual_of_R32_Pular_Pg1-29

Bu sayfa, kılavuzun PDF dosyasındaki metnin tamamıdır (sayfa sayfa). Görseller ve çizimler için PDF'i açın. — sibastore.com

Sayfa 1

Change for life

Service Manual

GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

Sayfa 2

Table of Contents

Part I : Technical Information...................................... 2

1. Summary......................................................................... 2

2. Specifications............................................................... 4

2.1 Specification Sheet..................................................................................................4

2.2 Capacity Variation Ratio According to Temperature..................................10

2.3 Cooling and Heating Data Sheet in Rated Frequency...............................11

3. Outline Dimension Diagram.................................. 12

3.1 Indoor Unit.................................................................................................................12

3.2 Outdoor Unit.............................................................................................................13

4. Refrigerant System Diagram................................ 15

5. Electrical Part.............................................................. 16

5.1 Wiring Diagram........................................................................................................16

5.2 PCB Printed Diagram.............................................................................................19

6. Function and Control............................................... 25

6.1 Remote Controller Introduction.........................................................................25

6.2 Brief Description of Models and Functions...................................................30

6.3 GREE+ App Operation Manual...........................................................................33

6.4 Ewpe Smart App Operation Manual.................................................................34

Part II : Installation and Maintenance ................... 35

7. Notes for Installation and Maintenance........... 35

8. Installation.................................................................... 40

8.1 Installation Dimension Diagram........................................................................40

8.2 Installation Parts-checking ................................................................................42

8.3 Selection of Installation Location.....................................................................42

8.4 Electric Connection Requirement.....................................................................42

Service Manual

Table of Contents

Sayfa 3

Service Manual

8.5 Installation of Indoor Unit....................................................................................43

8.6 Installation of Outdoor unit.................................................................................45

8.7 Vacuum Pumping and Leak Detection............................................................47

8.8 Check after Installation and Test operation..................................................47

9. Maintenance................................................................. 48

9.1 Error Code List........................................................................................................48

9.2 Procedure of Troubleshooting...........................................................................53

9.3 Troubleshooting for Normal Malfunction.......................................................67

10. Exploded View and Parts List............................ 69

10.1 Indoor Unit..............................................................................................................69

10.2 Outdoor Unit...........................................................................................................75

11. Removal Procedure................................................ 85

11.1 Removal Procedure of Indoor Unit.................................................................85

11.2 Removal Procedure of Outdoor Unit.............................................................90

Appendix.......................................................................... 110

Appendix 1: Reference Sheet of Celsius and Fahrenheit.............................110

Appendix 2: Configuration of Connection Pipe................................................110

Appendix 3: Pipe Expanding Method................................................................... 111

Appendix 4: List of Resistance for Temperature Sensor..............................112

Table of Contents

Sayfa 4

1. Summary

Indoor Unit:

A1 Panel:

Outdoor Unit:

GWH07AGAXB-K6DNA1A/O

GWH09AGCXB-K6DNA1A/O 
GWH21AGEXF-K6DNA1A/O

GWH28AGEXH-K6DNA1A/O 
GWH18AGDXE-K6DNA1A/O 

Remote Controller:

 YAP1F7(WiFi)

2
Technical Information

Service Manual

GWH24AGEXF-K6DNA1A/O 

Sayfa 5

Service Manual

Model list:

No
Model
Product code
Indoor model
Indoor product 

code
Outdoor model
Outdoor 
product code
1
GWH07AGAXB-K6DNA1A CB385012200 GWH07AGAXB-K6DNA1A/I CB385N12200 GWH07AGAXB-K6DNA1A/O CB385W12200
2
GWH09AGCXB-K6DNA1A CB385012100 GWH09AGCXB-K6DNA1A/I CB385N12100 GWH09AGCXB-K6DNA1A/O CB385W12100
3
GWH18AGDXE-K6DNA1A CB385012900 GWH18AGDXE-K6DNA1A/I CB385N12900 GWH18AGDXE-K6DNA1A/O CB385W12900
4
GWH21AGEXF-K6DNA1A CB385014100 GWH21AGEXF-K6DNA1A/I CB385N14100 GWH21AGEXF-K6DNA1A/O CB385W14100
5
GWH24AGEXF-K6DNA1A CB385013900 GWH24AGEXF-K6DNA1A/I CB385N13900 GWH24AGEXF-K6DNA1A/O CB385W13900
6
GWH28AGEXH-K6DNA1A CB385014300 GWH28AGEXH-K6DNA1A/I CB385N14300 GWH28AGEXH-K6DNA1A/O CB385W14300

3
Technical Information

Sayfa 6

Service Manual
2. Specifications

2.1 Specification Sheet

Model 
GWH07AGAXB-K6DNA1A 
GWH09AGCXB-K6DNA1A 

Product Code
CB385012200
CB385012100

Rated Voltage 
V~
220-240
220-240

Power 
Supply

Rated Frequency
Hz
50
50

Phases
1
1

Power Supply Mode
Outdoor
Outdoor

Cooling Capacity
W
2250
2650

Heating Capacity
W
2700
3200

Cooling Power Input
W
600
575

Heating Power Input
W
720
745

Cooling Current Input
A
3.1
2.95

Heating Current Input
A
3.8
3.95

Rated Input
W
1250
1350

Rated Cooling  Current
A
4.9
5.65

Rated Heating Current
A
5.65
6

3/h
520/470/450/420/310/290/250
740/630/560/490/420/390/360

Air Flow Volume
m

Dehumidifying Volume
L/h
0.6
0.8

EER 
W/W
3.75
4.6

COP 
W/W
3.75
4.3

SEER 
W/W
/
4.3

HSPF 
W/W
/
/

Application Area
m

2
10-16
12-18

Model
GWH07AGAXB-K6DNA1A/I
GWH09AGCXB-K6DNA1A/I 

Product Code
CB385N12200
CB385N12100

Fan Type
Cross-flow
Cross-flow

Fan Diameter Length(DXL) 
mm
Φ93X505
Ф98×630

Cooling Speed
r/min
1300/1200/1120/1050/920/800/750
1350/1200/1100/1000/850/750/650

Heating Speed
r/min
1300/1200/1120/1050/950/850/800
1200/1100/1040/950/900/880/850

Fan Motor Power Output
W
20
15

Fan Motor RLA
A
0.22
0.22

Fan Motor Capacitor 
μF
1
/

Evaporator Form 
Aluminum Fin-copper Tube
Aluminum Fin-copper Tube

Evaporator Pipe Diameter
mm
Φ5
Ф5

Evaporator Row-fin Gap
mm
2-1.4
2-1.4

Indoor  Unit 

Evaporator Coil Length (LXDXW)  
mm
509×22.8×266.7
634×22.8×304.8

Swing Motor Model
MP24AK MP24BA MP24HF
MP24HF MP24AK MP24BA

Swing Motor Power Output
W
1.5/1.5/1.5
1.5 1.5 1.5

Fuse Current
A
3.15
3.15

Sound Pressure Level 
dB (A) 
Cooling:39/36/34/32/28/23/22
Heating:39/36/33/31/29/25/23

Sound Power Level
dB (A) 
Cooling:55/52/50/48/44/39/38
Heating:55/52/49/47/45/41/39

Dimension (WXHXD) 
mm
704×260×185
825×293×196

Dimension of Carton Box (LXWXH)
mm
748×316×247
870×349×257

Dimension of Package (LXWXH) 
mm
753×332×258
875×365×268

Net Weight  
kg
7.5
9.5

Gross Weight
kg
9
11.5

4
Technical Information

Cooling:42/37/36/32/28/24/20
Heating:39/36/33/31/29/28/27

Cooling:57/52/51/47/43/39/35
Heating:57/52/49/47/45/44/43

Sayfa 7

Service Manual
2. Specifications

Outdoor Unit Model
GWH07AGAXB-K6DNA1A/O
GWH09AGCXB-K6DNA1A/O

Outdoor Unit Product Code
CB385W12200
CB385W12100

Compressor Manufacturer
ZHUHAI LANDA COMPRESSOR 

Compressor Model
QXF-A082zC170
QXF-A082zC170

Compressor Oil
ZE-G;ES RB68GX or equivalent
ZE-G;ES RB68GX or equivalent

Compressor Type
Rotary
Rotary

Compressor LRA.  
A
15.00
15.00

Compressor RLA  
A
2.56
2.56

Compressor Power Input
W
756.6
756.6

Compressor Overload Protector
/
/

Throttling Method
Capillary
Electron expansion valve

Set Temperature Range 
ºC
16~30
16~30

Cooling Operation  Ambient Temperature Range 
ºC
-10~50
-10~50

Heating Operation  Ambient Temperature Range 
ºC
-15~24
-15~24

Condenser  Form 
Aluminum Fin-copper Tube
Aluminum Fin-copper Tube

Condenser  Pipe Diameter 
mm
Φ7
Φ7

Condenser  Rows-fin Gap
mm
1-1.2
2-1.4

Condenser  Coil Length (LXDXW)  
mm
666×19.05×527
666×38.1×527

Fan Motor Speed
rpm
850
850

Fan Motor Power Output
W
30
30

Outdoor 

Fan Motor RLA  
A
0.40
0.4

Unit

Fan Motor Capacitor 
μF
/
2.5

Outdoor Unit Air Flow Volume
m

Fan Type
Axial-flow
Axial-flow

Fan Diameter
mm
Φ400
Φ400

Defrosting Method
Automatic Defrosting
Automatic Defrosting

Climate Type
T1
T1

Isolation
I
I

Moisture Protection
IPX4
IPX4

Permissible Excessive Operating Pressure for 
the Discharge Side
MPa
4.3
4.3

Permissible Excessive Operating Pressure for 
the Suction Side
MPa
2.5
2.5

Sound Pressure Level (H/M/L) 
dB (A) 
50/-/-
50/-/-

Sound Power Level (H/M/L) 
dB (A) 
60/-/-
61/-/-

Dimension(WXHXD) 
mm
732×555×330
732×555×330

Dimension of Carton Box (LXWXH)
mm
791×373×590
791×373×590

Dimension of Package(LXWXH)
mm
794×376×615
794×376×615

Net Weight  
kg
24
26.5

Gross Weight
kg
26.5
29

Refrigerant 
R32
R32

Refrigerant Charge
kg
0.46
0.65

Connection Pipe Length
m
5
5

Connection Pipe Gas Additional Charge
g/m
16
16

Outer Diameter Liquid Pipe
inch
1/4
1/4

Connection 

Outer Diameter Gas Pipe
inch
3/8
3/8

Pipe

Max Distance Height
m
10
10

Max Distance Length
m
15
15

Note: The connection pipe applies metric diameter.

The above data is subject to change without notice. Please refer to the nameplate of the unit.

5
Technical Information

ZHUHAI LANDA COMPRESSOR 

CO.,LTD

CO.,LTD

3/h
1950
1950

Sayfa 8

Model 
GWH28AGEXH-K6DNA1A
GWH21AGEXF-K6DNA1A

Product Code
CB385014300
CB385014100

Rated Voltage 
V~
220-240
220-240

Power 
Supply

Rated Frequency
Hz
50
50

Phases
1
1

Power Supply Mode
Outdoor
Outdoor

Cooling Capacity
W
8500
6400

Heating Capacity
W
9000
7400

Cooling Power Input
W
2297
1542

Heating Power Input
W
2647
1805

Cooling Current Input
A
10.4
11.5

Heating Current Input
A
12
11

Rated Input
W
3650
2600

Rated Cooling  Current
A
18.5
12.5

Rated Heating Current
A
16.5
12.5

3/h
1300/1050/1000/900/800/750/700/500
1300/1100/1050/950/900/850/800/700

Air Flow Volume
m

Dehumidifying Volume
L/h
3
2.5

EER 
W/W
3.7
4.15

COP 
W/W
3.4
4.10

SEER 
W/W
/
/

HSPF 
W/W
/
/

2
32-50
27-42

Application Area
m

Model
GWH28AGEXH-K6DNA1A/I
GWH21AGEXF-K6DNA1A/I

Product Code
CB385N14300
CB385N14100

Fan Type
Cross-flow
Cross-flow

Fan Diameter Length(DXL) 
mm
Φ108×830
Ф98×630

Cooling Speed
r/min
1400/1150/1100/1000/900/850/800//600 1400/1150/1100/1000/900/850/800/650

Heating Speed
r/min
1400/1200/1100/1000/900/800/750/-
1400/1200/1100/1000/900/800/750/-

Fan Motor Power Output
W
60
60

Fan Motor RLA
A
0.38
0.28

Fan Motor Capacitor 
μF
/
/

Evaporator Form 
Aluminum Fin-copper Tube
Aluminum Fin-copper Tube

Evaporator Pipe Diameter
mm
Φ7
Ф7

Evaporator Row-fin Gap
mm
2-1.4
2-1.3

Evaporator Coil Length 
(LXDXW)  
mm
850×25.4×342.9
850×25.4×342.9

Indoor  Unit 

Swing Motor Model
MP24HF/MP24AK/MP24HF 
MP24HF/MP24AK/MP24HF

Swing Motor Power Output
W
1.5/1.5/1.5
1.5/1.5/1.5

Fuse Current
A
3.15
3.15

Sound Pressure Level 
dB (A) 
Cooling:49/43/42/39/37/35/32/30

Heating:48/43/41/37/34/31/29/-

Sound Power Level
dB (A) 
Cooling:65/59/58/55/53/51/48/46

Heating:64/59/57/53/50/47/45/-

Dimension (WXHXD) 
mm
1075×333×246
1075×333×246

Dimension of Carton Box 
(LXWXH)
mm
1128×406×323
1128×406×323

Dimension of Package (LXWXH) 
mm
1133×414×333
1133×414×333

Net Weight  
kg
16
16

Gross Weight
kg
19
19

6
Technical Information

Service Manual

Cooling:49/43/41/38/35/33/29/27

Heating:39/36/33/31/29/28/27/-

Cooling:62/55/53/50/47/45/41/39

Heating:57/52/49/47/45/44/43/-

Sayfa 9

Service Manual

Outdoor Unit Model
GWH28AGEXH-K6DNA1A/O
GWH21AGEXF-K6DNA1A/O

Outdoor Unit Product Code
CB385W14300
CB385W14100

Compressor Manufacturer
ZHUHAI LANDA COMPRESSOR 

Compressor Model
QXFS-B238zX070
QXFS-M180zX170

Compressor Oil
/
/

Compressor Type
Rotary
Rotary

Compressor LRA.  
A
27.00
24.00

Compressor RLA  
A
4.30
3.50

Compressor Power Input
W
2020
1350

Compressor Overload Protector
/
HPC 115/95U1 KSD115ºC

Throttling Method
Electron expansion valve
Electron expansion valve

Set Temperature Range 
ºC
16~30
16~30

Cooling Operation  Ambient Temperature Range 
ºC
-10~50
-10~50

Heating Operation  Ambient Temperature Range 
ºC
-15~24
-15~24

Condenser  Form 
Aluminum Fin-copper Tube
Aluminum Fin-copper Tube

Condenser  Pipe Diameter 
mm
Φ7.94
Φ7

Condenser  Rows-fin Gap
mm
2-1.4
2-1.4

Condenser  Coil Length (LXDXW)  
mm
955X38.1X704
890×38.1×616

Fan Motor Speed
rpm
850
880

Fan Motor Power Output
W
90
60

Outdoor 

Fan Motor RLA  
A
0.70
0.65

Unit

Fan Motor Capacitor 
μF
/
/

Outdoor Unit Air Flow Volume
m

Fan Type
Axial-flow
Axial-flow

Fan Diameter
mm
Φ570
Φ520

Defrosting Method
Automatic Defrosting
Automatic Defrosting

Climate Type
T1
T1

Isolation
I
I

Moisture Protection
IPX4
IPX4

Permissible Excessive Operating Pressure for 
the Discharge Side
MPa
4.3
4.3

Permissible Excessive Operating Pressure for 
the Suction Side
MPa
2.5
2.5

Sound Pressure Level (H/M/L) 
dB (A) 
62/-/-
58/-/-

Sound Power Level (H/M/L) 
dB (A) 
72/-/-
67/-/-

Dimension(WXHXD) 
mm
1000×746×427
958×660×402

Dimension of Carton Box (LXWXH)
mm
1077×480×785
1029×453×715

Dimension of Package(LXWXH)
mm
1080×483×810
1032×456×737

Net Weight  
kg
51.5
42.5

Gross Weight
kg
56.5
47

Refrigerant 
R32
R32

Refrigerant Charge
kg
1.7
1.3

Connection Pipe Length
m
5
5

Connection Pipe Gas Additional Charge
g/m
40
16

Outer Diameter Liquid Pipe
inch
1/4
1/4

Connection 

Outer Diameter Gas Pipe
inch
5/8
1/2

Pipe

Max Distance Height
m
10
10

Max Distance Length
m
25
25

Note: The connection pipe applies metric diameter.

The above data is subject to change without notice. Please refer to the nameplate of the unit.

7
Technical Information

ZHUHAI LANDA COMPRESSOR 

CO.,LTD

CO.,LTD

3/h
4500
3800

Sayfa 10

Model 
GWH18AGDXE-K6DNA1A 
GWH24AGEXF-K6DNA1A

Product Code
CB385012900
CB385013900

Rated Voltage 
V~
220-240
220-240

Power 
Supply

Rated Frequency
Hz
50
50

Phases
1
1

Power Supply Mode
Outdoor
Outdoor

Cooling Capacity
W
5000
7100

Heating Capacity
W
6000
8000

Cooling Power Input
W
1290
1844

Heating Power Input
W
1460
2000

Cooling Current Input
A
6
8.1

Heating Current Input
A
6.5
8.8

Rated Input
W
2300
3200

Rated Cooling  Current
A
10
14.5

Rated Heating Current
A
10
13.5

3/h
1050/910/870/830/770/660/600
1300/1050/1000/900/820/750/650

Air Flow Volume
m

Dehumidifying Volume
L/h
1.8
2.5

EER 
W/W
3.87
3.85

COP 
W/W
4.1
4.00

SEER 
W/W
/
/

HSPF 
W/W
/
/

2
23-34
27-42

Application Area
m

Model
GWH18AGDXE-K6DNA1A/I
GWH24AGEXF-K6DNA1A/I

Product Code
CB385N12900
CB385N13900

Fan Type
Cross-flow
Cross-flow

Fan Diameter Length(DXL) 
mm
Ф106X739
Ф108×830

Cooling Speed
r/min
1400/1200/1120/1050/980/860/750
1400/1150/1100/1000/900/850/800/650

Heating Speed
r/min
1400/1200/1120/1050/950/850/750
1400/1200/1100/1000/900/800/750/-/-

Fan Motor Power Output
W
50
60

Fan Motor RLA
A
0.25
0.28

Fan Motor Capacitor 
μF
/
/

Evaporator Form 
Aluminum Fin-copper Tube
Aluminum Fin-copper Tube

Evaporator Pipe Diameter
mm
Φ7
Ф7

Evaporator Row-fin Gap
mm
2-1.4
2-1.3

Evaporator Coil Length 
(LXDXW)  
mm
715×25.4×304.8
850×25.4×342.9

Indoor  Unit 

Swing Motor Model
MP35CP
MP24AK/MP24HF/MP24HF

Swing Motor Power Output
W
2.5
1.5/1.5/1.5

Fuse Current
A
3.15
3.15

Sound Pressure Level 
dB (A) 
Cooling:46/41/39/37/35/32/27
Heating:48/43/41/39/35/32/28

Sound Power Level
dB (A) 
Cooling:62/57/55/63/51/48/43
Heating:58/53/51/49/45/42/38

Dimension (WXHXD) 
mm
982X311X221
1075×333×246

Dimension of Carton Box 
(LXWXH)
mm
1039X377X287
1128×406×323

Dimension of Package (LXWXH) 
mm
1044X385X297
1133×414×333

Net Weight  
kg
13
16

Gross Weight
kg
15.5
19

8
Technical Information

Service Manual

Cooling:50/44/43/40/36/34/32/30

Heating:50/45/42/39/36/34/32/-

Cooling:66/60/59/56/52/50/48/46

Heating:66/61/58/55/52/50/48/-

Sayfa 11

Service Manual

Outdoor Unit Model
GWH18AGDXE-K6DNA1A/O
GWH24AGEXF-K6DNA1A/O

Outdoor Unit Product Code
CB385W12900
CB385W13900

Compressor Manufacturer
ZHUHAI LANDA COMPRESSOR 

Compressor Model
QXF-M130zF170
QXFS-M180zX170

Compressor Oil
RB68GX or equivalent
/

Compressor Type
Rotary
Rotary

Compressor LRA.  
A
/
24.00

Compressor RLA  
A
5.36
3.50

Compressor Power Input
W
1196
1350

Compressor Overload Protector
/
HPC 115/95U1 KSD115ºC

Throttling Method
Electron expansion valve
Electron expansion valve

Set Temperature Range 
ºC
16~30
16~30

Cooling Operation  Ambient Temperature Range 
ºC
-10~50
-10~50

Heating Operation  Ambient Temperature Range 
ºC
-15~24
-15~24

Condenser  Form 
Aluminum Fin-copper Tube
Aluminum Fin-copper Tube

Condenser  Pipe Diameter 
mm
Φ7.94
Φ7.94

Condenser  Rows-fin Gap
mm
2-1.4
2-1.4

Condenser  Coil Length (LXDXW)  
mm
865×38.1×528
934×38.1×616

Fan Motor Speed
rpm
950
880

Fan Motor Power Output
W
40
60

Outdoor 

Fan Motor RLA  
A
0.70
0.65

Unit

Fan Motor Capacitor 
μF
/
/

Outdoor Unit Air Flow Volume
m

Fan Type
Axial-flow
Axial-flow

Fan Diameter
mm
Φ445
Φ520

Defrosting Method
Automatic Defrosting
Automatic Defrosting

Climate Type
T1
T1

Isolation
I
I

Moisture Protection
IPX4
IPX4

Permissible Excessive Operating Pressure for 
the Discharge Side
MPa
4.3
4.3

Permissible Excessive Operating Pressure for 
the Suction Side
MPa
2.5
2.5

Sound Pressure Level (H/M/L) 
dB (A) 
58/-/-
61/-/-

Sound Power Level (H/M/L) 
dB (A) 
68/-/-
68/-/-

Dimension(WXHXD) 
mm
873×555×376
958×660×402

Dimension of Carton Box (LXWXH)
mm
948×428×591
1029×453×715

Dimension of Package(LXWXH)
mm
951×431×620
1032×456×737

Net Weight  
kg
37
43.5

Gross Weight
kg
40
48

Refrigerant 
R32
R32

Refrigerant Charge
kg
1
1.45

Connection Pipe Length
m
5
5

Connection Pipe Gas Additional Charge
g/m
12
16

Outer Diameter Liquid Pipe
inch
1/4
1/4

Connection 

Outer Diameter Gas Pipe
inch
1/2
5/8

Pipe

Max Distance Height
m
10
10

Max Distance Length
m
25
25

Note: The connection pipe applies metric diameter.

The above data is subject to change without notice. Please refer to the nameplate of the unit.

9
Technical Information

ZHUHAI LANDA COMPRESSOR 

CO.,LTD

CO., LTD 

3/h
3000
3600

Sayfa 12

2. Specifications

2.2 Capacity Variation Ratio According to Temperature

7K
Heating:

Cooling

120

100

Capacity ratio (%)

80

60

Conditions
Indoor:DB27°C/WB19°C
Indoor air flow:Super High
Pipe length:5m

40

20

0

18
20
25
30
35
40
45
50

Outdoor temp.(°C)
Outdoor temp.(°C)

9K

Cooling

140

120

100

Capacity ratio (%)

80

60

Conditions
Indoor:DB27°C/WB19°C
Indoor air flow:Super High
Pipe length:5m

40

20

0

18
20
25
30
35
40
45
50

Outdoor temp.(°C)

18/21/24K

Cooling

100

90

80

70

Capacity ratio (%)

60

Conditions
Indoor:DB27°C/WB19°C
Indoor air flow:Super High
Pipe length:5m

50

40

30

20

10

0

- 10
- 5
0
5
10
15
20
25
30
35
40
45
50

Outdoor temp.(°C)
Outdoor temp.(°C)

10
Technical Information

Service Manual

140

120

100

Capacity ratio (%)

80

  
Condition Heating
Indoor:DB20°C
Indoor air flow: Super High
Pipe length:5m 

60

40

20

0

15
7
2
7
15
18
21
24

Heating:

140

120

Capacity ratio (%)

100

80

  
Condition Heating
Indoor:DB20°C
Indoor air flow: Super High
Pipe length:5m 

60

40

20

0

.15
.7
2
7
15
18
21
24

Outdoor temp.(°C)

Heating:

100

90

80

70

Capacity ratio (%)

60

Conditions
Indoor:DB20°C
Indoor air flow:Super High

50

Pipe length:5m

40

30

20

10

0

- 15
- 10
- 7
- 5
- 3
0
5
6
7
10
15
18
20
24

Sayfa 13

Service Manual

Cooling:
28K

120

Heating:

100

100

90

80

80

Capacity ratio (%)

Capacity ratio (%)

70

60

60

50

Conditions
Indoor:DB20°C
Indoor air flow:Super High

Conditions
Indoor:DB27°C/WB19°C
Indoor air flow:Super High
Pipe length:5m

40

40

Pipe length:5m

30

20

20

10

0

0

- 15
- 10
- 7
- 5
- 3
0
5
6
7
10
15
18
20

- 10
- 5
0
5
10
15
20
25
30
35
40
45
50

Outdoor temp.(°C)
Outdoor temp.(°C)

2.3 Cooling and Heating Data Sheet in Rated Frequency

Cooling:

Pressure of gas pipe connecting 

Inlet and outlet pipe temperature of 

Rated cooling condition(°C) (DB/WB) 

indoor and outdoor unit

heat exchanger
Fan speed of 

Fan speed of 

Model

outdoor unit
Indoor 
Outdoor 
P (MPa) 
T1 (°C) 
T2 (°C) 

indoor unit

7K
0.8~1.1
12 ~ 15
75~40

TURBO
High
9K
1~1.3
12 ~15
78~38

27/19
35/24

21/24K
0.9~1.1
12 ~ 14
75 ~ 37

28K
0.7~0.9
10 ~ 12
78 ~ 37

Heating:

Pressure of gas pipe 
connecting indoor and 

Rated heating condition(°C) 

Inlet and outlet pipe temperature 

of heat exchanger
Fan speed of 

Fan speed of 

(DB/WB)
Model 

outdoor unit 

indoor unit

outdoor unit 

Indoor
Outdoor 
P (MPa) 
T1 (°C) 
T2 (°C) 

7K
2.0~2.6
75~38
2 ~ 5

TURBO
High 
9K
2.0~2.5
70~35
2 ~5

20/-
7/6

21/24K
2.2~2.4
70 ~ 35
2 ~ 4

28K
2.4~2.7
71 ~ 36
1 ~ 7

Instruction:
T1: Inlet and outlet pipe temperature of evaporator 
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve 
Connection pipe length: 5 m.

11
Technical Information

Sayfa 14

Service Manual
3. Outline Dimension Diagram

3.1 Indoor Unit

W

D

H

AGA
AGD

W3
W2
W1

W3
W2
W1

Φ55

Φ55

55
55

42

40

42

40

75

75

178
89

AGC

AGE

W3
W2
W1

W2
W1
W3

Φ55

Ø70
Ø70

175
60

43

43

116

155

Unit:mm

Model
W
H
D
W1
W2
W3

AGA
704
260
185
93
462
149
AGC
825 
293   
196
113
 542
170
AGD
982
311
221
122.5
707.5
152
AGE
1075
333
246
184
707.5
183.5

* Recommended distance

12
Technical Information

Sayfa 15

3. Outline Dimension Diagram

Service Manual

3.2 Outdoor Unit

07/09K

285

555

330

Unit:mm

21/28K

340

660

402

Unit:mm

13
Technical Information

675

732

455

310

889

958

371

570

Sayfa 16

28K

369

923

746

427

1000

395

Unit:mm

610

18K

316.5

805

555

376
873

30

348.6

Unit:mm

528

14
Technical Information

Service Manual

Sayfa 17

Service Manual
4. Refrigerant System Diagram

7K

Cooling and heating model

 Indoor unit   
 Outdoor unit  

Suction
Heat 
exchanger
(evaporator)  
Heat 
exchanger
(condenser)  

Connection pipe specification:
Liquid pipe:1/4" 
Gas pipe:3/8" 

9/18/21/24/28K

Cooling and heating model

Indoor unit 

Suction
Heat 
exchanger
(evaporator) 
Heat 
exchanger
(condenser) 

Connection pipe specification:
Liquid pipe:1/4" 
Gas pipe:3/8" 9K
Gas pipe:1/2" 18/21K
Gas pipe:5/8" 28K

15
Technical Information

Gas pipe
side

 Valve

4-Way valve 

Discharge

Accumlator 
 Compressor  

Liquid pipe
side

 Valve

Strainer
Strainer
Capillary

COOLING 

HEATING 

Outdoor unit 

Gas pipe
side

 Valve

4-Way valve 

Discharge

Accumlator

Compressor

side
Liquid pipe

 Valve

Strainer
Electric 
expand 
valve

Strainer

COOLING 

HEATING 

Sayfa 18

5. Electrical Part

Service Manual

5.1 Wiring Diagram

●Instruction

Symbol
Symbol Color 
Symbol
Symbol Color 
Symbol
Name

WH
White
GN
Green
CAP
Jumper cap

YE
Yellow
BN 
Brown
COMP
Compressor

RD
Red
BU
Blue
Grounding wire

YEGN
Yellow/Green
BK 
Black
/
/

VT
Violet
OG
Orange
/
/

Note: Jumper cap is used to determine fan speed and the swing angle of horizontal lover for this model.

● Indoor Unit

7K

OPTIONAL

OPTIONAL

ROOM
TUBE

TEMP.
SENSOR

TEMP.
SENSOR

WIRED
CONTROLLER

DRY
CONTACT

RECEIVER AND
DISPLAY BOARD

FAN MOTOR

M1

AP3

AP4

AP1

DISPLAY

θ

θ

PE
EVAPORATOR

RT1

RT2

YEGN

T-SENSOR

DISP

PG
PGF

PE
EARTH-PLATE

COM-MANUAL

DOOR-C
(DRY-C)

CAP

YEGN
XT

AP2

OUTDOOR UNIT

PRINTED CIRCUIT BOARD

BU

BU

JUMP

N(1)

N(N1)

BK

BK

COM-OUT

2

3
BN

BN

AC-L

SWING-UD1

SWING-UD2

CABLE
CONNECTING

SWING-LR

HEALTH

BLOCK
TERMINAL

M2

M3

M4

ION
PLASMACLUSTER

UP-DOWN

UP-DOWN

LEFT-RIGHT

STEPPING

STEPPING

600007063739

MOTOR
STEPPING

MOTOR

MOTOR

OPTIONAL

OPTIONAL

16
Technical Information

Sayfa 19

Service Manual

9K

237,21$/

237,21$/

)$102725
78%( 5220

*$7(
&21752/

:,5('
&21752//(5

7(03
6(1625
7(03
6(1625

5(&(,9(5$1'
',63/$<%2$5'

$3

$3

0

',63/$<
$3

­
­

57
57

7(50,1$/

'225&
'5<&

%/2&.

&200$18$/

',63
76(1625

'&02725

%8

%8

1

287'22581,7

%.
11

&$3

%.

&20287



-803
$3
35,17('&,5&8,7%2$5'

%1

%1

$&/



<(*1

;7

&$%/(
&211(&7,1*

<(*1

6:,1*/5

6:,1*8'

6:,1*8'

+($/7+

3(

(9$325$725

0

0

0

,21
3/$60$&/867(5

/()75,*+7

83'2:1

83'2:1

02725
67(33,1*
67(33,1*
02725

67(33,1*

02725

600007065783

237,21$/

237,21$/

18/21/24/28K

TUBE ROOM

TEMP.
SENSOR

TEMP.
SENSOR

OPTIONAL 

RECEIVER AND
DISPLAY BOARD

LEFT-RIGHT

MOTOR
STEPPING

FAN MOTOR

WIRED
 CONTROLLER

DISPLAY
AP1

M1

θ
θ

M4

RT1
RT2

TERMINAL

BLOCK

DC-MOTOR

T-SENSOR

DISP

SWING-LR

COM-MANUAL

BU
CAP

BU
N

OUTDOOR  UNIT

N(1)

JUMP
AP2

BK

BK

COM-OUT

2

3
BN

PRINTED CIRCUIT BOARD

BN

AC-L

YEGN

YEGN
E YEGN

CONNECTING

(DRY-C)

SWING-UD1

SWING-UD2

XT

HEALTH

CABLE

DOOR-C

PE
EVAPORATOR

M3

M2

ION
PLASMACLUSTER

UP-DOWN

UP-DOWN

DRY

STEPPING

STEPPING

CONTACT

MOTOR

MOTOR

OPTIONAL
OPTIONAL 

60000706411701

17
Technical Information

Sayfa 20

5. Electrical Part

● Outdoor Unit

7/9K

237,21$/ 237,21$/
237,21$/

:$51,1*

%RWWRP
%DQG
+HDWHU

(;+$867
7(03
2875220
7(03
28778%(

9$/9(
:$<

(/(&7521,&
(;3$16,21
9$/9(

3OHDVHGRQ
WWRXFKDQ\
WHUPLQDOZKHQWKHPDFKLQH
LVUXQQLQJVWRSSLQJRU

7(03
6(1625 6(1625 6(1625

<9

(.9

(+

.
.
.
57

KDVEHHQSRZHUHGRIIIRU
OHVVWKDQPLQXWHVWR

97
97

57
57

SUHYHQWWKHULVNRI
HOHFWULFVKRFNέ

76(1

:$<

+($7%

)$

0$*1(7,&5,1*

;7

%8

/

%8
%.
%1

0DLQ%RDUG
$3

,1'22581,7

1
&208&20,1
$&B/$&/

1

/

%.
%1



/

/
'5('
'5(''&

2)$1

&1

<(*1

<(*1

7(50,1$/

(

%/2&.

3(

5'
<(
%8

0$*1(7,&
5,1*

%8
%1%.

/
1

/
/
/

&1
&1
'5('
0$,1%2$5' &1

3(

<(*1

0

<(*1

3(

<(
5'
8
9
:
%8

)$1

3(

32:(5

3(



02725

&203

237,21$/

'5('
02'8/(

600007065732

&203

237,21$/

18/21/24/28K

&203

:$51,1*
3OHDVHGRQ
WWRXFKDQ\
WHUPLQDOZKHQWKHPDFKLQH
LVUXQQLQJVWRSSLQJRU

237,21$/

29(5/2$'
3527(&725

&203

(;+$867
7(03
2875220
7(03
28778%(

8
9
:
%8

7(03
6(1625 6(1625 6(1625

<(
5'

0$*1(7,&
5,1*

6$7

KDVEHHQSRZHUHGRIIIRU
OHVVWKDQPLQXWHVWR

.
.
.
57

/
/
/

:+
:+

57
57

SUHYHQWWKHULVNRI
HOHFWULFVKRFNέ

76(1625

76(1

&1

29&&203

0$*1(7,&5,1*

;7

%8

/

%8
%.
%1

,1'22581,7

35,17('&,5&8,7%2$5'
$3

1


1

/

%.
%1

'5('

&20,1

&20,11(5
$&/
(

/

'5('&2008
'5(''&

/

)$

'5('&20
'5('32:(5

2)$1

:$<

<(*1

<(*1

7(50,1$/

3(

%/2&.

3(

%8
%1%.

97
97

/
1

&1
&1
'5('
&1

<9
(.9

<(*1

<(*1

0

(/(&7521,&

0$,1%2$5'

3(

3(

32:(5

(;3$16,21

9$/9(
:$<

)$1

9$/9(

3(

02725

237,21$/
237,21$/

237,21$/
237,21$/

'5('
02'8/(

600007065952

These wiring diagrams are subject to change without notice; please refer to the one supplied with the unit.

18
Technical Information

Service Manual

Sayfa 21

5. Electrical Part

Service Manual

5.2 PCB Printed Diagram

Indoor Unit

4
5
6
7
8
9
7K

3

2

16

1

No.
Name 
No.
Name 

1
Terminal of communication
9
Left &Right swing interface(only for the 
model with this function)

2
Fuse
10
Interface of PG feedback 

3
Live wire terminal
11
Display interface

4
Neutral wire terminal
12
Terminal of temperature sensor

5
PG Motor terminal 
13
Jumper cap

6
Interface of health function
14
Interface of gate-control (only for the 
model with this function) 

7
Up&down swing interface 2
15
Wired controller terminal (only for the 
model with this function)  

8
Up&down swing interface 1
16
Terminal of live wire used for supplying 
power for outdoor unit 

19
Technical Information

10

11

12

13

14

15

Sayfa 22

9/18/21/24/28K

3
4
5
6
7
8

1

15

14

No.
Name 
No.
Name 

1
Fuse
9
Up&down swing 1

2
Live wire
10
Interface of display board 

3
Neutral wire
11
Temperature sensor

4
Dommunication wire 
12
Door control 

5
DC fan
13
Wired controller

6
Cold plasma
14
Earthing wire 

7
Left&right swing 
15
Terminal of live wire

8
Up&down swing 2

20
Technical Information

Service Manual

9

10

11

12

13

Sayfa 23

Service Manual

Outdoor Unit

7/9K

1

2

3

4

5
6
7

No.
Name 

1
Earthing wire 

2
Neutral wire, live wire and communication cable

3
4-way valve

4
Electric heating belt of chassis

5
Interface of outdoor fan

6
Interface of electronic expansion valve

7
Temperature sensor 

8
Three-phase terminal of compressor

21
Technical Information

8

Sayfa 24

21/24K

1
2
3
4
6
7
8
9

5

11
12
13

No.
Name 

No.
Name 

1
Eathing wire 

9
Overload interface of compressor 

2
Live wire

10
Interface of compressor

3
Neutral wire 

11
DRED interface

4
Communication cable

12
Interface of electronic expansion valve

5
4-way valve

13
E disk interface

6
Electric heating belt of chassis

7
Interface of outdoor fan

8
Temperature sensor 

22
Technical Information

Service Manual

10

Sayfa 25

Service Manual

28K

1

2

3

4

5

6

7

8

9

10

11

12

13
14

No.
Name 
No.
Name 

1
Neutral wire
8
Terminal of high pressure protection

2
Earthing wire
9
Temperature sensor 

3
Live wire
10
Overload interface of compressor

4
Communication cable
11
Interface of electronic expansion valve

5
4-way valve
12
Terminal of DRED

6
Electric heating belt of chassis
13
E disk interface

7
Interface of outdoor fan
14
Interface of compressor

23
Technical Information

Sayfa 26

18K

1
3
5
7
9

6
8
4
2

2
1
1
1

No
Name
No
Name

1
Earthing wire 
8
Interface of outdoor fan

2
Live wire
9
Temperature sensor 

3
Communication cable
10
Overload interface of compressor

4
Neutral wire 
11

5
4-way valve 
12

6
Electric heating belt of chassis
13

7
Interface of electronic expansion valve

24
Technical Information

Service Manual

10

13

Dred
communication

E disk interface

Interface of compressor

Sayfa 27

Service Manual
6. Function and Control

6.1 Remote Controller Introduction

Notice:

1.This is a general use remote controller. It could be used for the air conditioner with multifunction. For the functions which the 
model doesn't have, if press the corresponding button on the remote controller, the unit will keep the original running status.

2.After putting through the power, the air conditioner will give out a sound. Operation indicator " 
 " is ON (red indicator, the 
colour is different for different models). After that, you can operate the air condition-er by using remote controller.

3.Under on status, pressing the button on the remote controller, the signal icon " 
 " on the display of remote controller will 
blink once and the air condition-er will give out a “ di ” sound, which means the signal has been sent to the air conditioner.

4.As for the models with functions of WiFi or wired controller, the indoor unit must has been controlled by standard remote 
controller under auto mode first, and then the function of adjustable temperature under auto mode can be realized by APP or 
the wired controller.

5.This remote controller can adjust the temperature under auto mode. When matching with the unit which is without the 
function of adjustable temperature under auto mode, the set temperature under auto mode may be invalid, or the displayed set 
temperature on the unit is not same as that on the remote controller under auto mode.

 button

Press this button to turn on the unit. Press this button again to 

turn off the unit.

 button
Press this button to select your required operation mode :

● When selecting auto mode, air conditioner will operate 
automatically according to the sensed temperature. Set 
temperature can't be adjusted and will not be displayed 
as well. Press "FAN" button can adjust fan speed. 
Press " 
  "/" 
 " button can adjust fan blowing angle.
● After selecting cool mode, air conditioner will operate 
under cool mode. Press " " or " 
 " button to adjust set 
temperature. Press "FAN" button to adjust fan speed. 
Press" 
 "/" 
 " button to adjust fan blowing angle.

25
Technical Information

● When selecting dry mode, the air conditioner operates at low 
speed under dry mode. Under dry mode, fan speed can't be 
adjusted. Press " 
 "/" 
 " button to adjust fan blowing angle. 
● When selecting fan mode, the air conditioner will only blow 
fan, no cooling and no heating. Press "FAN" button to adjust 
fan speed. Press" 
  "/"  " button to adjust fan blowing angle. 
When selecting heat mode, the air conditioner operates under 
heat mode. Press "▲" or "▼" button to adjust set temperature. 
Press "FAN" button to adjust fan speed. Press " 
 " / "  " button 
to adjust fan blowing angle. 
● When selecting heating mode, the air conditioner operates 
under heat mode. Press " 
 " or " 
 "button to adjust set 
temperature. Press "FAN" button to adjust fan speed. Press "
 " 
/ " "button to adjust fan blowing angle. (Cooling only unit won't 
receive heating mode signal. If setting heat mode with remote 
controller, press ON/OFF button can’t start up the unit).
Note:
● For preventing cold air, after starting up heat mode,indoor unit 
will delay 1~5 minutes to blow air (Actual delay time depends on 
indoor ambient temperature).
● Set temperature range from remote controller: 16~30
oC(61-
86
oF).
● Under auto mode, temperature can be displayed;Under auto 
mode, set temperature can be adjusted.
● This mode indicator is not available for some models.

 button
This button is used for setting Fan Speed in the sequence that 

goes from AUTO, 
 ,  , 
 , 
 , 
 , 
 , then back to 

Auto.
Note: 
● Under AUTO speed, air conditioner will select proper fan speed 
automatically according to factory default setting.
● It's low fan speed under dry mode.
● X-FAN function Hold fan speed button for 2s in cool or dry 
mode, the icon " 
 " is displayed and the indoor fan will continue 
operation for a few minutes in order to dry the indoor unit even 
though you have turned off the unit. After energization, X-FAN 
OFF is defaulted. X-FAN is not available in auto, fan or heat mode. 
● This function indicates that moisture on evaporator of indoor 
unit will be blowed after the unit is stopped to avoid mould.
● Having set X-FAN function on: After turning off the unit 

Sayfa 28

by pressing " ON/OFF " button indoor fan will continue 
running for a few minutes. at low speed. In this per- iod, 
Hold fan speed button for 2s to stop indoor fan directly.
Having set X-FAN function off: After turning off the unit by 
pressing "    " button, the complete unit will be off directly.

 
TURBO button
Under COOL or HEAT mode, press this button to turn to quick 

COOL or quick HEAT mode. " 
  " icon is displayed on remote 

controller. Press this button again to exit turbo function and " 

  " icon will disappear. If start this function, the unit will run at 

super-high fan speed to cool or heat quickly so that the ambient 

temperature approaches the preset temperature as soon as 

possible. 

/
 button

● Press " 
 " or " 
" button once increase or d ecrease set 

temperature 1°C (°F). Holding " " or " 
 " button, 2s later, 

set temperature on remote controller will change quickly. On 

releasing button after setting is finished, temperature indicator on 

indoor unit will change accordingly.

● When setting T-ON, T-OFF or CLOCK, press " " or " " button 

to adjust time. (Refer to CLOCK, TON,T-OFF buttons)

 button
Press this button can select left & right swing angle. Fan blow 
angle can be selected circularly as below:

Note:
● Press this button continuously more than 2s, the main unit will 
swing back and forth from left to right, and then loosen the button, 
the unit will stop swinging and present position of guide louver 
will be kept immediately.
● Under left and right swing mode, when the status is switched 
from off to  
, if press this button again 2s later, 
  status 
will switch to off status directly; if press this button again within 
2s, the change of swing status will also depend on the circulation 
sequence stated above.
● The function is only available for some models.

 button
Press this button can select left & right swing angle.  Fan blow 

angle can be selected circularly as below:

no display
(horizontal louvers stops

at current position)

● When selecting " 
 ", air conditioner is blowing fan 

automatically. Horizontal louver will automatically swing up & 

down at maximum angle.  

●When selecting " 
、     、    、   、  ", air conditioner is blowing fan 

at fixed position. Horizontal louver will stop at the fixed position.

● When selecting " 
、   、      ", air conditioner is blowing fan at 

fixed angle. Horizontal louver will send air at the fixed angle.

● Hold " 
 "button above 2s to set your required swing angle. 

26
Technical Information

Service Manual

When reaching your required angle, release the button.   
Note:
●  " 
 、  
               
  、 " may not be available. When air conditioner 
receives this signal, the air conditioner will blow fan automatically.
● Press this button continuously for more than 2s, the main 
unit will swing back and forth from up to down, and then loosen 
the button, the unit present position of guide louver will be kept 
immediately.
● Under up and down swing mode, when the status is switched 
from off to 
 , if press this button again 2s later, 
 status will 
switch to off status directly; if press this button again within 2s, 
the change of swing status will also depend on the circulation 
sequence stated above.  

T-ON  T-OFF button

● T-ON button

"T-ON" button can set the time for timer on. After pressing this 
button, " 
 " icon disappears and the word "ON" on remote 
controller blinks. Press "▲" or " ▼ " button to adjust T-ON 
setting. After each pressing "▲" or " ▼ " button, T-ON setting will 
increase or decrease 1min. Hold "▲" or " ▼ " button, 2s later, the 
time will change quickly until reaching your required time. Press 
"T-ON" to confirm it. The word "ON" will stop blinking. " 
 " icon 
resumes displaying. Cancel T-ON: Unde the condition that T-ON 
is started up, press "T-ON " button to cancel it.
● T-OFF button
"T-OFF" button can set the time for timer off. After pressing this 
button, " 
 " icon disappears and the word "OFF" on remote 
controller blinks. Press "▲" or " ▼ " button to adjust T-OFF 
setting. After each pressing "▲" or " ▼ " button, T-OFF setting 
will increase or decrease 1min. Hold "▲" or " ▼ " button, 2s later, 
the time will change quickly until reaching your required time. 
Press "T-OFF" word "OFF" will stop blinking.  " 
 " icon resumes 
displaying. Cancel T-OFF. Under the condition that T-OFF is 
started up, press "T-OFF" button to cancel it.
Note:

● Under on and off status, you can set T-OFF or T-ON 
simultaneously.
● Before setting T-ON or T-OFF, please adjust the clock time.
● After starting up T-ON or T-OFF,set the constant circulating
valid.
● After that, air conditioner will be turned on or turned off 
according to setting time.ON/OFF button has no effect on setting.
If you don’t need this function, please use remote controller to 
cancel it.

I FEEL button

Press this button to start I FEEL function and " 
 " will be 

displayed on the remote controller. After this function is set, the 
remote controller will send the detected ambient temperature 
to the controller and the unit will automatically adjust the indoor 
temperature according to the detected temperature. Press this 

button again to cancel I FEEL function and " 
 " will disappear.

● Please put the remote controller near user when this function 

Sayfa 29

Service Manual
6. Function and Control

is set. Do not put the remote contro ller near the object of high 
temperature or low temperature in order to avoid detecting 
inaccurate amb ient temperature. When I FEEL function is turned 
on, the remote controller should be put within the area where 
indoor unit can receive the signal sent by the remote controller.

CLOCK button

Press this button to set clock time. " 
 " icon on remote controller 
will blink. Press "▲" or " ▼ " button within 5s to set clock time. 
Each pressing of "▲" or " ▼ " button, clock time will increas e or 
decrease 1 minute.If hold "▲" or " ▼ " button, 2s later, time will 
change quickly. Release this button when reaching your required 
time. Press "CLOCK" button to confirm the time. " 
 " icon stops 
blinking.
Note:

● Clock time adopts 24-hour mode.
● The interval between two operations can't exceed 5s. 
Otherwise, remote controller will quit setting status. Operation for 
TIMER ON/TIMER OFF is the same.

SLEEP button

● Press this button, can select Sleep 1 (
 1), Sleep 2 (
 2), 

Sleep 3 (
 3) and cancel the Sleep, circulate between these, 

after electrified, Sleep Cancel is defaulted.

● Sleep 1 is Sleep mode 1, in Cool modes; sleep status after run 

for one hour, the main unit setting temperature will increase 1 , 

two hours, setting temperature increased 2℃, then the unit will 

run at this setting temperature; In Heat mode: sleep status after 

run for one hour, the setting temperature will decrease 1 , two 

hours, setting temperature will decrease 2 , then the unit will run 

at this setting temperature.

● Sleep 2 is sleep mode 2, that is air conditioner will run 

according to the presetting a group of sleep temperature curve.

● Sleep 3-the sleep curve setting under Sleep mode by DIY;

(1) Under Sleep 3 mode, press “Turbo” button for a long 

time, remote controller enters into user individuation sleep 

setting status, at this time, the time of remote controller will 

display “1hour”, the setting temperature “88” will display the 

corresponding temperature of last setting sleep curve and blink 

(The first entering will display according to the initial curve setting 

value of original factory);

(2) Adjust “+” and “-” button, could change the corresponding 

setting temperature, after adjusted, press “Turbo” button for 

confirmation;

(3) At this time, 1hour will be automatically increased at the timer 

position on the remote control, (that are "2hours" or "3hours" or 

"8hours"), the place of setting temperature "88" will display the 

corresponding temperature of last setting sleep

curve and blink;

(4) Repeat the above step (2)~(3) operation, until 8 hours 

temperature setting finished, sleep,curve setting finished, at this 

27
Technical Information

time, the remote controller will resume the original timer display; 

temperature display will resume to original setting temperature.

● Sleep3- the sleep curve setting under Sleep mode by DIY could 

be inquired:

The user could accord to sleep curve setting method to inquire 

the presetting sleep curve, enter into user individuation sleep 

setting status, but do not change the temperature, press "Turbo" 

button directly for confirmation. Note: In the above presetting or 

enquiry procedure, if continuously within 10s, there is no button 

pressed, the sleep curve setting within 10s, there is no button 

pressed, the sleep curve setting status will be automatically quit 

and resume to display the original displaying. In the presetting 

or enquiry procedure, press "ON/OFF" button, "Mode" button, 

"Sleep" button, the sleep curve setting or enquiry status will quit 

similarly.

WiFi
 button

Press " WiFi "  button to turn on WiFi function,   "WiFi " icon will 
be displayed on the remote controller; Hold " WiFi "  button for 5s 
to turn off WiFi function and " WiFi " icon will disappear. 
Under off status, press "MODE" and " WiFi " buttons 
simultaneously for 1s, WiFi module will restore factory settings.
● This function is only available for some models.

 button

Press this button to achieve the on and off of health and 
scavenging functions in operation station. Press this button 
for the first time to start scavenging function; LCD displays
" 
 ". Press the button for the second time to start health and 
scavenging functions simultaneously; LCD displays " 
 " and " 
 ". 
Press this button for the third time to quit health and scavenging 
functions simultaneously. Press the button for the fourth time to 
start health function; LCD display " 
 ". Press this button again to 
repeat the operation above.
● This function is applicable to partial of models .

LIGHT button

Press this button to turn off display light on indoor unit. " 
 " icon 
on remote controller disappears. Press this button again to turn 

on display light. " 
 " icon is displayed.
Press and hold the LIGHT button for 5 seconds to activate or 
cancel the auto light function. When the set temperature on the 
remote controller blinks 3 times, it means the auto light function is
successfully turned on. When this function is active, the panel 
lamp will light up for 20 seconds every time the indoor unit 
receives a signal from the remote controller and then go off 
automatically.
Auto light function is only available for some models.

TEMP button

Press this button, you can see indoor set temperature, indoor 
ambient temperature on indoor unit' s display. The setting on 
remote controller is selected circularly as below:

no display

Sayfa 30

Service Manual
6. Function and Control

Introduction for icons on display screen

I feel

Set fan speed
(No
fan speed. It’s
displayed only after turning it on.)

Turbo mode

Send signal

Auto mode

Operation mode

Cool mode

Dry mode

Fan mode
Heat mode

Sleep mode
 8ȭ heating function

Power limiting operation

Health mode 
Scavenging function

Quiet

X-FAN function

Set temp.

Indoor ambient 
temp.

Temp. 

display type

Outdoor ambient 
temp.

Clock

Set temperature

WiFi function

Set time
TIMER ON / TIMER OFF

Left & right swing
Up & down swing

Child lock

Function introduction for combination buttons

Energy-saving function

Under cooling mode, press "TEMP" and "CLOCK"buttons 
simultaneously to start up or turn off energysaving function. 
When energy-saving function is started up, "SE" will be shown 
on remote controller,and air conditioner will adjust the set 
temperature automatically according to ex-factorysetting to reach 
to the best energy-saving effect. Press "TEMP" and "CLOCK" 
buttons simultaneously again to exit energysaving function.
Note:
● Under energy-saving function, fan speed is defaulted at auto 
speed and it can't be adjusted.
● Under energy-saving function, set temperature can't be 
adjusted. Press "TURBO" button and the remote controller won't 
send signal.
● Sleep function and energy-saving function can't operate at the 
same time. If energy-saving function has been set under cool 
mode, press sleep button will cancel energy-saving function. If 
sleep function has been set under cool mode, start up the energy-
saving function will cancel sleep function.

8°C heating function

Under heat mode, press "TEMP" and "CLOCK" buttons 
simultaneously to start up or turn off 8°C heating function. When 
this function is started up, "
" and "8°C" will be shown on remote 

28
Technical Information

controller, and the air conditioner keep the heating status at 8°C.
Press "TEMP" and "CLOCK" buttons simultaneously again to exit 
8°C heating function.
Note:
● Under 8°C heating function, fan speed is defaulted at auto 
speed and it can't be adjusted.
● Under 8°C heating function, set temperature can't be adjusted.
Press "TURBO" button and the remote controller won't send 
signal.
● Sleep function and 8°C heating function can't operate at the 
same time. If 8°C heating function has been set under heat 
mode, press sleep button will cancel 8°C heating function. If 
sleep function has been set under heat mode, start up the 8°C 
heating function will cancel sleep function.
● Under °F temperature display, the remote controller will display 
46°F heating.

Child lock function

Press "▲" and "▼" simultaneously to turn on or turn off child lock 
function. When child lock function is on, " " icon is displayed on 
remote controller.If you operate the remote controller, the " " icon 
will blink three times without sending signal to the unit.

Temperature display switchover function

Under OFF status, press "▼" and "MODE" buttons 
simultaneously to switch temperature display between °C and °F.

Night mode

Under cooling or heating mode, when turning on sleep mode and 
turn to low speed or quiet notch, the outdoor unit would enter into 
night mode.
Note:
When you feel that the cooling and heating effect is poor, please 
press "FAN" button to other fan speed or press "SLEEP" button 
to exit the night mode.
The night mode can only work under normal ambient 
temperature.
This function is only available for some models.

Auto clean function

Under unit off status, hold "MODE" and "FAN" buttons 
simultaneously for 5s to turn on or turn off the auto clean function. 
When the auto clean function is turned on, indoor unit displays 
"CL" . During the auto clean process of evaporator, the unit will 
perform fast cooling or fast heating. There may be some noise, 
which is the sound of flowing liquid or thermal expansion or cold 
shrinkage. The air conditioner may blow cool or warm air, which 
is a normal phenomenon. During cleaning process, please make 
sure the room is well ventilated to avoid affecting the comfort.
Note:
● The auto clean function can only work under normal ambient 
temperature. If the room is dusty, clean it once a month; if not, 
clean it once every three months. After the auto clean function is 
turned on,you can leave the room. When auto clean is finished, 
the air conditioner will enter standby status.
● This function is only available for some models.

Sayfa 31

Service Manual
6. Function and Control

function

Press "MODE" and "SLEEP" buttons simultaneously to start 
 
function.

 function is for limiting power of the whole unit. Press this button, 
the remote controller will circu-larly display as the following:

blank
No Setting

● Maximum power limited under the  mode is lower than that of 
mode.
● If you want to cancel the power limiting function, press the 
button  till the icon in remote controller is not displayed.
● When the remote controller is turned off, power limiting function 
is cancelled. If you want to activatethe function, please repress 
this button.

● If the current power is lower than the maximum power of 
 
mode, then the power will not be limited after entering into such 
mode.
● For the model with one outdoor unit and two indoor units, if any 
one of indoor units enters into power limiting function, the outdoor 
unit will enter into the set limiting power mode of indoor unit; 
when two indoor units enter into power limiting mode, then the 
power of outdoor unit will be limited according to the lower power 
of the two indoor units.
Note:
● This function is only available for some models.
Replacement of batteries in remote controller

1. Lift the cover along the direction of arrow (as shown in Fig 1① ).
2.Take out the original batteries (as shown in Fig 1 ② ).
3.Place two 7# (AAA 1.5V) dry batteries, and make sure the 
position of “ + ” polar and “ - ” polar is correct (as shown in Fig 2 

③ ).
4.Reinstall the cover (as shown in Fig 2 ④ ).

①

④

②

③

Fig.1
Fig.2 

NOTICE:
● During operation, point the remote control signal sender at 
the receiving window on indoor unit.
The distance between signal sender and receiving window 
should be no more than 8m, and there should be no 
obstacles between them.
● Signal may be interfered easily in the room where there is 
fluorescent lamp or wireless telephone; remote controller 
should be close to indoor unit during operation.
● Replace new batteries of the same model when 
replacement is required.
● When you don’t use remote controller for a long time, 
please take out the batteries.
● If the display on remote controller is fuzzy or there’s no 
display, please replace batteries.

29