R32_T-Fresh_User_Manual

Bu sayfa, kılavuzun PDF dosyasındaki metnin tamamıdır (sayfa sayfa). Görseller ve çizimler için PDF'i açın. — sibastore.com

Sayfa 1

Change for life

Owner's Manual

Original Instructions

Split Type Floor-standing Air Conditioner

Thank you for choosing our product.
Please read this Owner’s Manual carefully before operation and 
retain it for future reference.
If you have lost the Owner's Manual, please contact the local agent 
or visit www.gree.com or send an email to global@cn.gree.com for 
the electronic version.

Sayfa 2

GVH32ALXH-K6DNC7A

Sayfa 3

Content

Operation Notices

The Refrigerant ................................................................................................................. 1

Precautions .......................................................................................................................... 2

Parts Name .......................................................................................................................... 8

Operation Guide

Button’s Name and Function ................................................................................................
Introduction for icons on display screen of air conditioner ....................................................
Button’s introduction ...........................................................................................................10

Introduction for buttons on remote controller .....................................................................
Introduction for icons on display screen  .............................................................................
Buttons on remote controller ..............................................................................................

Function introduction for combination buttons ....................................................................

Replacement of batteries in remote controller ....................................................................

Clean and maintenance .....................................................................................................
Maintenance

Malfunction

Malfunction ..........................................................................................................................20

Safety operation of flammable refrigerant ................................................................... 24

Installation Notice

Installation dimension diagram .......................................................................................... 

Safety precautions for installing and relocating the unit ..................................................... 27

Tools for installation ........................................................................................................... 28

Selection of installation location .........................................................................................

Requirements for electric connection .................................................................................

Installation

Installation of indoor unit ....................................................................................................30
Installation of outdoor unit .................................................................................................. 34
Vacuum pumping .............................................................................................................. 37

Leakage detection ............................................................................................................. 37

Check after installation .......................................................................................................38

Test operation .................................................................................................................... 38

Attachment

Installation instructions of anti-collapse chain ....................................................................
Configuration of connection pipe ........................................................................................
Pipe expanding method ......................................................................................................

Specialist’s Manual ................................................................................................

This appliance is not intended for use by persons (including children) with reduced physical, sensory 
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision 
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.

 9
 9

12
12

13

 18
 17

 19

26

28

29

40
39

42
43

Sayfa 4

Explanation of Symbols

DANGER

WARNING

CAUTION

NOTICE

Exception Clauses

Manufacturer will bear no responsibilities when personal injury or 
property loss is caused by the following reasons.

1.

Damage the product due to improper use or misuse of the product;

2.

Alter, change, maintain or use the product with other equipment without abiding

by the instruction manual of manufacturer;

3.

After verification, the defect of product is directly caused by corrosive gas;

4.

After verification, the defects are due to improper operation during transportation 
of product;
Operate, repair, maintain the unit without abiding by instruction manual or related
regulations;
After verification, the problem or dispute is caused by the quality specification or
performance of parts and components that produced by other manufacturers;
The damage is caused by natural calamities, bad using environment or force
majeure.

5.

6.

7.

If it needs to install, move or maintain the air conditioner, please contact dealer 
or local service center to conduct it at first. Air conditioner must be installed, 
moved or maintained by appointed  unit. Otherwise, it may cause serious 
damage or personal injury or death.
When refrigerant leaks or requires discharge during installation, maintenance, 
or disassembly, it should be handled by certified professionals or otherwise in 
compliance with local laws and regulations.

Indicates a hazardous situation that, if not avoided, will
result in death or serious injury.  

Indicates a hazardous situation that, if not avoided, could 
result in death or serious injury. 

Indicates a hazardous situation that, if not avoided, may
result in minor or moderate injury.  

Indicates important but not hazard-related information, 
used to indicate risk of property damage. 

Indicates a hazard that would be assigned a signal word 
WARNING or CAUTION.

Sayfa 5

Appliance filled with flammable gas R32.

Before use the appliance, read the owner’s manual first.

Before install the appliance, read the installation manual first.

Before repair the appliance, read the service manual first.

The Refrigerant

To realize the function of the air conditioner unit, a special refrigerant circulates in 
the system. The used refrigerant is the fluoride R32, which is specially cleaned. 
The refrigerant is flammable and inodorous. Furthermore, it can lead to explosion 
under certain conditions. But the flammability of the refrigerant is very low. It can 
be ignited only by fire.

Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm
to the ozonosphere. The influence upon the greenhouse effect is also lower. R32
has got very good thermodynamic features which lead to a really high energy
efficiency. The units therefore need a less filling.

WARNING:

Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacture. Should repair be necessary, contact your nea-
rest authorized Service Centre. Any repairs carried out by unqualified personnel
may be dangerous. The appliance shall be stored in a room without continuously
operating ignition sources. (for example: open flames, an operating gas appliance
or an operating electric heater.) Do not pierce or burn.

Appliance shall be installed, operated and stored in a room with a floor area larger
than X m . 

2

 (Please refer to table "a" in section of " Safety operation of flammable 

refrigerant " for Space X.)

Appliance filled with flammable gas R32. For repairs, strictly follow manufacturer’s
instructions only. Be aware that refrigerants may not contain an odour. Read specialist’s 
manual.

1

Sayfa 6

Precautions

Operation and Maintenance

This appliance can be used by children aged from 8 
years and above and persons with reduced physical, 
sensory or mental capabilities or lack of experience 
and knowledge if they have been given supervision or 
instruction concerning use of the appliance in a safe 
way and understand the hazards involved. 
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by 
children without supervision.
Do not connect air conditioner to multi-purpose socket.
Otherwise, it may cause fire hazard.
Do disconnect power supply when cleaning air 
conditioner. Otherwise, it may cause electric shock.
If the supply cord is damaged, it must be replaced by 
the manufacturer, its service agent or similarly qualified 
persons in order to avoid a hazard.
Do not wash the air conditioner with water to avoid 
electric shock.
Do not spray water on indoor unit. It may cause electric
shock or malfunction.
After removing the filter, do not touch fins to avoid injury.
Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.

WARNING

2

Sayfa 7

Precautions

Maintenance must be performed by qualified 
professionals. Otherwise, it may cause personal injury 
or damage.

Do not repair air conditioner by yourself. It may cause 

electric shock or damage. Please contact dealer when 
you need to repair air conditioner. 

Do not extend fingers or objects into air inlet or air 

outlet. It may cause personal injury or damage.

Do not block air outlet or air inlet. It may cause 
malfunction.

Do not spill water on the remote controller, otherwise the 

remote controller may be broken.

When below phenomenon occurs, please turn off air 

conditioner and disconnect power immediately, and then 

contact the dealer or qualified professionals for service.

●Power cord is overheating or damaged.

●There’s abnormal sound during operation.

●Circuit break trips off frequently.

●Air conditioner gives off burning smell.

●Indoor unit is leaking.

If the air conditioner operates under abnormal conditions, 
it may cause malfunction, electric shock or fire hazard.

When turning on or turning off the unit by emergency 
operation switch, please press this switch with an insulating 
object other than metal.

objects. It may cause damage or personal injury.
Do not step on top panel of outdoor unit, or put heavy 

WARNING

3

Sayfa 8

Precautions

Attachment

Installation must be performed by qualified professionals. 
Otherwise, it may cause personal injury or damage.

Must follow the electric safety regulations when installing 
the unit.

According to the local safety regulations, use qualified 

power supply circuit and circuit break.

Do install the circuit break. If not, it may cause malfunction. 

An all-pole disconnection switch having a contact separation 

of at least 3mm in all poles should be connected in fixed 
wiring.

Including an circuit break with suitable capacity, please 

note the following table. Air switch should be included 

magnet buckle and heating buckle function, it can protect
the circuit-short and overload.

Air Conditioner should be properly grounded. Incorrect 

Don't use unqualified power cord.
grounding may cause electric shock.

Make sure the power supply matches with the requirement 
of air conditioner. Unstable power supply or incorrect wiring
may result in electric shock, fire hazard or malfunction.
Please install proper power supply cables before using the
air conditioner.

grounding wire of power socket.
Properly connect the live wire, neutral wire and 

any work related to electricity and safety.
Be sure to cut off the power supply before proceeding 

WARNING

4

Sayfa 9

Precautions

Do not put through the power before finishing installation.

the manufacturer, its service agent or similarly qualified 
If the supply cord is damaged, it must be replaced by 

persons in order to avoid a hazard.

The temperature of refrigerant circuit will be high, please 

keep the interconnection cable away from the copper 
tube.

The appliance shall be installed in accordance with 

national wiring regulations.

Installation must be performed in accordance with the 

requirement of NEC and CEC by authorized personnel 
only.

The air conditioner is the first class electric appliance. It 

must be properly grounding with specialized grounding 
device by a professional. Please make sure it is always 
grounded effectively, otherwise it may cause electric shock.

The yellow-green wire in air conditioner is grounding 

wire, which can't be used for other purposes.
The grounding resistance should comply with national 
electric safety regulations.

The appliance must be positioned so that the plug is 
accessible.

All wires of indoor unit and outdoor unit should be 
connected by a professional. 

If the length of power connection wire is insufficient, please 
contact the supplier for a new one. Avoid extending the 
wire by yourself.

WARNING

5

Sayfa 10

Precautions

For the air conditioner with plug, the plug should be   

reachable after finishing installation.

If you need to relocate the air conditioner to another 
must be installed in the line.
For the air conditioner without plug, an circuit break 

place, only the qualified person can perform the work. 
Otherwise, it may cause personal injury or damage.

Select a location which is out of reach for children and 

far away from animals or plants.If it is unavoidable, 
please add the fence for safety purpose.

The indoor unit should be installed close to the wall 

Please notice that the unit is filled with flammable gas 
R32. Inappropriate treatment of the unit involves the
risk of severe damages of people and material. Details
to this refrigerant are found in chapter “refrigerant”.
Check whether the maintenance area or the room area
meet the requirement of the nameplate.
- It’s only allowed to be operated in the rooms that meet

the requirement of the nameplate.
Check whether the maintenance area is well-ventilated.
- The continuous ventilation status should be kept 

during the operation process.

Check whether there is fire source or potential fire source

in the maintenance area. 

- The naked flame is prohibited in the maintenance area;

and the “no smoking” warning board should be hanged.

Check whether the appliance mark is in good condition.

- Replace the vague or damaged warning mark.

Please use the flammable gas detector to check before

unload and open the container.

No fire source and smoking.
According to the local rules and laws.

WARNING

6

Sayfa 11

Precautions

The air conditioner is not allowed to use in a room that
  
has running fire (such as fire source, working coal gas
ware, operating heater).

It is not allowed to drill hole or burn the connection pipe.
The air conditioner must be installed in a room that is
larger than the minimum room area. The minimum room
area is shown on the nameplate or following table a.

Leak test is a must after installation.

Instructions for installation and use of this product are
provided by the manufacturer.

Working temperature range

50/26
Maximum heating
27/-
24/18

Maximum cooling

NOTICE:

●The operating temperature range (outdoor temperature) for cooling only unit is
   -10℃~ 50℃; for heat pump unit is -15℃ ~ 50℃.

WARNING

Indoor side DB/WB(℃)

32/23
Outdoor side DB/WB(℃)

7

Sayfa 12

Parts Name

Indoor Unit

air outlet

display and button

display and button

FAN

ON/OFF

MODE
FUNC.

panel

air inlet

FAN

ON/OFF

FUNC.
MODE

(Display content or position may be different from above
graphics, please refer to actual products)

remote controller

Outdoor Unit

Air inlet (back)

Handle

Air outlet

NOTICE:
Actual product may be different from above graphics, please refer to actual
products.

8

Sayfa 13

Button’s Name and Function

1
ON/OFF button

2
MODE button

3
FAN button

4
FUNCTION button

5

3

ON/OFF
5
▼/▲ button

1

FAN

6
button
/

2

4

MODE

FUNC.

6

Introduction for icons on display screen
of air conditioner

Ambient temperature 
or set temperature 
display or others

Timer 
display

Operation

display

E-Heater display

Cooling display

Defrosting display

Dry display

Heating display

Fan display

Fan speed display

9

Sayfa 14

Button’s introduction

Note:

This series unit adopts touch buttons. You only need to touch the buttons slightly. 

1

ON/OFF button

●  

Press this button to turn on or turn off the unit.(Note: Under X-FAN mode, 
    press this button to turn on the unit directly.)

2

MODE button

●Every time press this button, the mode will switchover in cycle among.

COOLING
DRY

HEATING
FAN

(Note: Cooling only unit won’t accept heating operation signal. For cooling only unit, 
pressing MODE button under FAN mode will skip heating mode and enter cooling 
mode.)

FAN button
3

●Press this button and then fan speed can be selected and displayed in the
    sequence as below: 

(low) 
(medium)
(high) 

(turbo)

    (Note:Only low fan speed is available for dry mode.  Fan speed can't be adjusted 
    under dry mode. Turbo cannot be set in FAN mode.)

FUNCTION button
4
●  

Under on status, press Function button to switch between timer and auxiliary 
    heating function setting (auxiliary heating can be set only in heating mode). When 
    timer or auxiliary heating icon is blinking, it means this function can be set. Press 
    "▲" or "▼" button to set function. If there’s no operation change within 5s after 
    setting is finished, the function setting will be confirmed. Or press Function button 
    again to exit or confirm the function.When the function is selected through Function
    button, if the unit is not turned off and no remote control signal is received within 
    2min, pressing Function button again to circulate from the previous set function. 
    After 2min or the unit is turned off or remote control signal is received, pressing 
    Function button again to circulate from timer icon. (Note: Only when the unit is 
    under heating mode and with auxiliary heating function, auxiliary heating function 
    can be turned on or off through Function button.)
    Under off status, if the unit is in X-FAN status, press Function button to turn off the 
    unit directly; if the unit is not in X-FAN status,  press Function button to set timer ON. 

●  

10

Sayfa 15

Button’s introduction

5
increase or decrease
    1℃. Temperature adjustment range is 16℃~30℃. This button is invalid under 

auto mode. Timer setting can be set in 1h increment among 0~24h. When 
it is adjusted to auxiliary heating function setting through Function button, 
press this button to turn on or turn off auxiliary heating. (Note: auxiliary heating 
is valid only for the model with this function.) 
Hold "
" and "
" buttons for 3s and the air conditioner will display "LC", which

    function buttons under off status are all invalid. Hold these two button for 3s 
    again to release the lock. 

button
6

Left and right swing: this button controls  the left and right swing motor, single
    press it to switchover between ON and OFF.

Up and down swing: this button controls  the up and down swing motor, single

    press it to switchover between ON and OFF.

Icon function introduction

Operation display

It indicates the air conditioner is

put through the power. Under on 
status, this indicator is on; under 
off status, this indicator is off. 

Timer display

●When this indicator is on, it
indicates the timer function
is turned on.

Heating display

When this indicator is on, it
indicates the heating mode is
turned on.

Defrosting display

When this indicator is on, it
indicates the defrosting function
is turned on.

Dry display

●When this indicator is on, it indicates
the dry mode is turned on. 

E-Heater display

When this indicator is on, it indicates 

the E-heater function is turned on. 

This function is only available for some 
models.

Cooling display

When this indicator is on, it indicates 
the cooling mode is turned on. 

Fan display

When this indicator is on, it indicates
the fan mode is turned on.

Fan speed display

Displays the fan speed. The fan speed
is displayed as below:

(turbo)

11

Sayfa 16

Buttons on remote controller

1
7

8
2
9

4
3
10
5

6
7
12

9
8
13

13
10

14
11

15

Introduction for icons on display screen

Set fan speed
(No
only after turning it on.)
Operation mode

Auto mode
Cool mode

Dry mode
Fan mode

Heat mode

Set time

TIMER ON/TIMER OFF

Turbo fan speed

Quiet mode

X-FAN function

1
ON/OFF button

2
MODE button

3
FAN button

4
SAVE button

▲

5

▲/     button

6

COOL button

HEAT button

     button

     button

SLEEP button

11
WiFi button

X-FAN button

 button 

14
LIGHT button

15
TIMER button

12

{

fan speed. It’s displayed

Send signal

battery power
 This is a general remote controller.Some 
 models have this function while some
 do not. Please refer to the actual models.

WiFi{

Child lock

Switch temperature displaying type on
the unit’s display

function
Left & right swing
Up & down swing

Sleep mode

12

Sayfa 17

Introduction for buttons on remote controller

Note:

●This is a general use remote controller, it could be used for the air conditioners
with multifunction; For some function, which the model doesn't have, if press
the corresponding button on the remote controller that the unit will keep the
original running status.

●After putting through the power, the air conditioner will give out a sound.
Operation indicator "     " is ON . After that, you can operate the air conditioner by
using remote controller.
●Under on status, pressing the button on the remote controller, the signal icon "    "
on the display of remote controller will blink once and the air conditioner will give
out a “di” sound, which means the signal has been sent to the air conditioner.

ON/OFF button
1

Press this button can turn on or turn off the air conditioner. After turning on the air
conditioner, indoor unit will give out a sound.

MODE button
2
Press this button to select your required operation mode.

AUTO
COOL
DRY
FAN
HEAT

●When selecting auto mode, air conditioner will operate automatically according
to the sensed temperature. Set temperature can’t be adjusted and will not be
displayed as well. Press "FAN" button can adjust fan speed. Press "     " / "    "
button can adjust fan blowing angle.
●After selecting cool mode, air conditioner will operate under cool mode. Cool
indicator "     " on indoor unit is ON(This indicator is not available for some models).
Pres

s "▲" or "    " button to adjust set temperature. Press "FAN" button to adjust
fan speed. Press "     " / "    " button to adjust fan blowing angle.
●When selecting dry mode, the air conditioner operates at low speed under dry
mode. Dry indicator "     " on indoor unit is ON(This indicator is not available for
some models). Under dry mode, fan speed can’t be adjusted. Press "     " / "    "
button to adjust fan blowing angle.
●When selecting fan mode, the air conditioner will only blow fan, no cooling and
no heating. Fan indicator "     " on indoor unit is ON. Press "FAN" button to adjust
fan speed. Press"     " / "    " button to adjust fan blowing angle.

▲

13

Sayfa 18

Introduction for buttons on remote controller

●When selecting heating mode, the air conditioner operates under heat mode.
Heat indicator "      " on indoor unit is ON(This indicator is not available for some
models). Press "▲" or "    " button to ad

▲

just set temperature. Press "FAN" button
to adjust fan speed. Press "     " / "    " button to adjust fan blowing angle. (Cooling
only unit won’t receive heating mode signal. If setting heat mode with remote
controller, press ON/OFF button can’t start up the unit).
Note:
●For preventing cold air, after starting up heating mode, indoor unit will delay 1~5
minutes to blow air (actual delay time is depend on indoor ambient temperature).
●Set temperature range from remote controller: 16~30℃(61~86°F);
Fan speed: auto, quiet speed, low speed, medium speed, high speed, turbo speed.

3
FAN button

Pressing this button can set fan speed circularly as: auto (AUTO), QUIET(      ), 

 high(         ), turbo(         ).
low(    ), medium(      ),

Auto

Note:

●Under AUTO speed, air conditioner will select proper fan speed automatically
   according to ex-factory setting.

●It’s Low fan speed under Dry mode.
●Turbo cannot be set in FAN mode.

4 SAVE button

Under cooling mode, press this button to start up or turn off energy-saving function. 
When energy-saving function is started up, "SE" will be shown on remote controller, 
and air conditioner will adjust the set temperature automatically according to 
ex-factory setting to reach to the best energy-saving effect. Press this button again 
to exit energy-saving function. 

▲/     button
5

▲

▲

●Press "▲" or "    " button once increase or decrease set temperature 1℃(°F).
Holding "▲" or "    " button, 2s later, set temperature on remote controller will
change quickly. On releasing button after setting is finished, temperature indica-
   tor on indoor unit will change accordingly. (Temperature can’t be adjusted under

▲

   auto mode)

●When setting TIMER ON, TIMER OFF, press "▲" or "    " button to adjust time.
(Refer to TIMER button for details)

14

▲

Sayfa 19

Introduction for buttons on remote controller

COOL button
6

●Press this button, unit will operate in cool mode.

HEAT button
7

●Press this button, unit will operate in heat mode.

8
 button

●Under simple swing mode, press this button can turn on ("      " icon is displayed) or
turn off ("      " icon is not displayed) the left&right swing function.

●When the unit is turned off by remote controller, press "▲" button and "      "

button can switch between single swing mode and fixed-angle swing mode.
"      " on the remote controller will flash twice.

Under fixed-angle swing mode, press this button and then left&right swing status will
circulate as shown in the right figure:

●This remote controller is the general type remote controller. When remote controller
receives the signal of "      " , swing status is same as "      " ; when remote controller
receives "      " , swing status is same as left&right swing OFF.

9

 button

●Under simple swing mode, press this button can turn on ("      " icon is displayed)
   or turn off ("      " icon is not displayed) the up&down swing function.
●When the unit is turned off by remote controller, press "▲" button and "     "
   button can switch between single swing mode and fixed-angle swing mode.  
   "      " on the remote controller will flash twice. 
   Under fixed-angle swing mode, press this button and the up&down swing status will 
   circulate as shown in the right figure: 

no display

no display

15

Sayfa 20

Introduction for buttons on remote controller

10 SLEEP button

Under COOL or HEAT mode, press this button to start up sleep function.
"     " icon is displayed on remote controller. Press this button again to cancel sleep
function and "     " icon will disappear.After powered on, Sleep Off is defaulted. After
the unit is turned off, the Sleep function is canceled.  
In this mode, set temperature will be adjusted with the change of time. Under Fan、
DRY and Auto modes, this function is not available.

11
WiFi button

Press "WiFi"  button to turn on WiFi function, "WiFi" icon will be displayed on the 
remote controller; 
Hold "WiFi"  button for 5s to turn off WiFi function and "WiFi" icon will disappear.
Under off status, press "MODE" and "WiFi" buttons simultaneously for 1s, WiFi 
module will restore factory settings.

This function is only available for some models.

12 X-FAN button

Pressing this button in COOL or DRY mode, the icon "      " is displayed and the 
indoor fan will continue operation for a few minutes in order to dry the indoor unit 
even though you have turned off the unit. After energization, X-FAN OFF is

 defaulted.X-FAN is not available in AUTO, FAN or HEAT mode.
This function indicates that moisture on evaporator of indoor unit will be blowed 
after the unit is stopped to avoid mould.

Having set X-FAN function on: After turning off the unit by pressing ON/OFF 

button indoor fan will continue running for about a few minutes. at low speed.
In this period, press X-FAN button to stop indoor fan directly.
Having set X-FAN function off: After turning off the unit by pressing ON/OFF 
button, the complete unit will be off directly.

Only under cooling mode and dry mode, press this button can turn on (characters 
of “X-FAN” are displayed)  or turn off (characters of “X-FAN” are not displayed) X-
FAN function.

13 

n
o
tt
u
b 

Maximum power limited under the       mode is lower than that of       mode.
If you want to cancel the power limiting function, press the button      till the icon 
in remote controller is not displayed.

When the remote controller is turned off, power limiting function is cancelled. If
you want to activate the function, please repress this button.

blank

No Setting

16

Sayfa 21

Introduction for buttons on remote controller

       mode, then the
●If the current power is lower than the maximum power of
power will not be limited after entering into such mode.
For the model with one outdoor unit and two indoor units, if any one of indoor
units enters into power limiting function, the outdoor unit will enter into the set
limiting power mode of indoor unit; when two indoor units enter into power
limiting mode, then the power of outdoor unit will be limited according to the
lower power of the two indoor units.

●

Note:

●This function is only available for some models.

14
LIGHT button

Press this button to turn off display light on indoor unit. Press this button again 
to turn on display light. 

At ON status, press this button once can set TIMER OFF. The character of HOUR
15

●
TIMER 
▲
    
▲

▲

ON. After each pressing of "

" or "    " button, time will increase or decrease half an

▲

hour
▲
. When holding "    " or "    " button, 2s lat

▲

er, the time will change quickly until to

●
   Cancel TIMER OFF: Press "TIMER" button again under TIMER OFF status.

At OFF status, press this button once can set TIMER ON. Please refer to TIMER

   off for detailed operation. 

   Cancel TIMER ON: Press "TIMER" button again under TIMER ON status.

●T
Note:

ime setting range: 0.5-24 hours.
●

Time interval between two operations can’t exceed 5s. Otherwise, remote
controller will exit the setting status automatically.

Function introduction for combination buttons

Child lock function

▲

Press "▲" and "    " simultaneously to turn on or turn off child lock function. When
child lock function is on, "    " icon is displayed on remote controller. If you operate
the remote controller, the "    " icon will blink three times without sending signal to
the unit.

17

Sayfa 22

Temperature display switchover function

Under OFF status, press "    " and "MODE

" buttons simultaneously to switch temp-
erature display between ℃ and ℉.

Replacement of batteries in remote controller

 1. Lift the cover along the direction of arrow (as shown in Fig 1 ①).
 
 2. Take out the original batteries (as shown in Fig 1 ②).
 
3. Place two 7# (AAA 1.5V) dry batteries, and make sure the position of “+”
polar and “-” polar is correct (as shown in Fig 2③).
 
4. Reinstall the cover (as shown in Fig 2 ④).

NOTICE

●During operation, point the remote control signal sender at the receiving
window on indoor unit.
●The distance between signal sender and receiving window should be no
more than 8m, and there should be no obstacles between them.
●Signal may be interfered easily in the room where there is fluorescent lamp
or wireless telephone; remote controller should be close to indoor unit during
operation.
●Replace new batteries of the same model when replacement is required.
●When you don’t use remote controller for a long time, please take out the
batteries.
●If the display on remote controller is fuzzy or there’s no display, please
replace batteries.

▲

Fig.1
Fig.2 

18

Sayfa 23

Clean and maintenance

Note:

■

Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.
Do not wash the air conditioner with water to avoid electric shock.
Do not use volatile liquid to clean the air conditioner.
Do not use liquid or corrosive detergen t clean the appliance and do not splash
 water or other liquid onto it, otherwise, it may damage the plastic components,
even cause electric shock.

■
■
■

Clean surface of indoor unit

When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth
or wet cloth to wipe it.

NOTICE: Checking before use-season

Check whether air inlet and air outlet are blocked.
1.
2.
good condition.
Check whether air switch, plug and socket are in

Check whether filter is clean.
3.
4.
with batteries.
Check whether the remote controller is installed

5. Check whether mounting bracket for outdoor unit
is damaged or corroded. If yes, please contact dealer.
6. Check whether drainage pipe is damaged.

NOTICE: Checking after use-season

1. Disconnect power supply.
Clean filter and indoor unit’s panel.
2.
3.
4.
Clear dust and obstructions from the outdoor unit.
Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.

Notice for recovery

1. Many packing materials are recyclable materials. Please dispose them in
    appropriate recycling unit.
2. If you want to dispose the air conditioner, please contact local dealer or
    consultant service center for the correct disposal method.

19

Sayfa 24

Malfunction

General phenomenon analysis

Please check below items before asking for maintenance. If the malfunction still
can’t be eliminated, please contact local dealer or qualified professionals.

Phenomenon
Check items
Solution

●

Whether it's interfered severely
(such as static electricity, stable
voltage)?

●

Whether remote controller is

within the signal receiving
range?

●

Whether there are obstacles?

Indoor unit
can’t receive
remote
controller’s
signal or
remote
controller
has no action.

●

Whether remote controller is
pointing at the receiving

window?
●Is sensitivity of remote controll-

er low; fuzzy display and no
display?

●

No display when operating
remote controller?

●

Fluorescent lamp in room?

●

Power failure?

●Is plug loose?

●Reinsert the plug.
●Air switch trips off or fuse is

●Wiring has malfunction?
burnt out?

Air conditioner
can’t operate

●Unit has restarted immediately

after stopping operation?

Whether the function setting for
remote controller is correct?
●

●

Pull out the plug. Reinsert

the plug after about 3min, and
then turn on the unit again.

●

Signal receiving range is 8m.

●Remove obstacles.

●Select proper angle and point
the remote controller at the re-
ceiving window on indoor unit.
●Check the batteries. If the

power of batteries is too low,
please replace them.

●Check whether remote contr-
oller appears to be damaged.
If yes, replace it.

Take the remote controller
close to indoor unit.
●Turn off the fluorescent lamp
and then try it again.

●

●wait until power recovery.

●Ask professional to replace

air switch or fuse.

●Ask professional to replace it.

●Wait for 3min, and then turn

on the unit again.

●Reset the function.

20

Sayfa 25

Malfunction

Phenomenon
Check items
Solution

●Because indoor air is cooled
Mist is emitted
from indoor
unit’s air outlet

●Indoor temperature and hum-
idity is high?

●Air inlet or air outlet of indoor
unit is blocked?

●Under heating mode, indoor
temperature is reached to set

No air emitted
from indoor
unit

temperature?

●Heating mode is turned on
just now?

●Unit is operating under auto
●Temperature can’t be adjus-

mode?

Set temperat-
ure can’t be
adjusted

●Your required temperature
●Set temperature range:

exceeds the set temperature
range?

●Voltage is too low?

Cooling (hea-
ting) effect is 
not good.

●Filter is dirty?

●Set temperature is in proper

range?

●Door and window are open?

●Whether there’s odour source, ●Eliminate the odour source.

Odours are
emitted

●Clean the filter.
such as furniture and cigaret-
te, etc.

rapidly. After a while, indoor
temperature and humidity will
be decrease and mist will di-
sappear.

●Eliminate obstacles.

●After reaching to set

temperature, indoor unit will
stop blowing out air.

●In order to prevent blowing
out cold air, indoor unit will be
started after delaying for se-
veral minutes, which is a
normal phenomenon.

ted under auto mode. Please
switch the operation mode if
you need to adjust tempera-
ture.

16℃~30℃.

●Wait until the voltage resu-

mes normal.

●Clean the filter.
●Adjust temperature to proper

range.

●Close door and window.

21

Sayfa 26

Malfunction

Phenomenon
Check items
Solution

●Disconnect power, put back
Air conditioner
operates
normally
suddenly

●Whether there’s interference,
such as thunder, wireless
devices, etc.

Outdoor unit
has vapor

●Heating mode is turned on?

●Air conditioner is turned on or
●The noise is the sound of

“Water flowing”
noise

turned off just now?

Cracking noise ● Air conditioner is turned on or

turned off just now?

power, and then turn on the
unit again.

●During defrosting under

heating mode, it may gener-
ate vapor, which is a normal
phenomenon.

refrigerant flowing inside the
unit, which is a normal phe-
nomenon.

●This is the sound of friction

caused by expansion and/or
contraction of panel or other
parts due to the change of
temperature.

22

Sayfa 27

Malfunction

Error code

●

When air conditioner status is abnormal, temperature indicator on indoor unit will
blink to display corresponding error code. Please refer to below list for identific-
ation of error code.

Error code

It can be eliminated after restarting the unit. If not, please

H3

contact qualified professionals to deal with it.

It can be eliminated after restarting the unit. If not, please

H6

contact qualified professionals to deal with it.
It can be eliminated after restarting the unit. If not, please

E1

contact qualified professionals to deal with it.

It can be eliminated after restarting the unit. If not, please

E3

contact qualified professionals to deal with it.

It can be eliminated after restarting the unit. If not, please

E4

contact qualified professionals to deal with it.
It can be eliminated after restarting the unit. If not, please

E5

contact qualified professionals to deal with it.

It can be eliminated after restarting the unit. If not, please

E6

contact qualified professionals to deal with it.

It can be eliminated after restarting the unit. If not, please

E8

contact qualified professionals to deal with it.
It can be eliminated after restarting the unit. If not, please

e6

contact qualified professionals to deal with it.
F0
Please contact qualified professionals to deal with it.
Please contact qualified professionals to deal with it.
Please contact qualified professionals to deal with it.
Please contact qualified professionals to deal with it.
Please contact qualified professionals to deal with it.
Please contact qualified professionals to deal with it.

F1
F2
F3
F4
F5

Note: If there're other error codes, please contact qualified professionals for service.

WARNING

■

When below phenomenon occurs, please turn off air conditioner and discon-
nect power immediately, and then contact the dealer or qualified professionals

for service.

●
Power cord is overheating or damaged.

●

Air switch trips off frequently.
●
There’s abnormal sound during operation.

●
Indoor unit is leaking.
Air conditioner gives off burning smell.
●

■Do not repair or refit the air conditioner by yourself.

■

If the air conditioner operates under abnormal conditions, it may cause malf-
unction, electric shock or fire hazard.

Troubleshooting

23

Sayfa 28

Safety operation of flammable refrigerant

Qualification requirement for installation and maintenance man

All the work men who are engaging in the refrigeration system should bear the
valid certification awarded by the authoritative organization and the qualification
for dealing with the refrigeration system recognized by this industry. If it needs
other technician to maintain and repair the appliance, they should be supervised
by the person who bears the qualification for using the flammable refrigerant.
It can only be repaired by the method suggested by the equipment’s manufacturer.

Installation notes

The air conditioner is not allowed to use in a room that has running fire (such as fire
source, working coal gas ware, operating heater).

It is not allowed to drill hole or burn the connection pipe.
The air conditioner must be installed in a room that is larger than the minimum room
area. The minimum room area is shown on the nameplate or following table a.
Leak test is a must after installation.

table a - Minimum room area ( m  )
2

Charge amount (kg) ≤1.2 1.3 1.4
1.5
1.6
1.7
1.8
1.9
2
2.1
2.2
2.3
2.4
2.5

floor location

/
14.5 16.8 19.3 22 24.8 27.8 31 34.3 37.8 41.5 45.4 49.4 53.6

Minimum

/

room

window mounted

5.2 6.1
7
7.9
8.9
10 11.2 12.4 13.6
15
16.3 17.8 19.3

2
area( m  )

wall mounted

/

1.6 1.9
2.1
2.4
2.8
3.1
3.4
3.8
4.2
4.6
5
5.5
6

ceiling mounted

/

1.1 1.3
1.4
1.6
1.8
2.1
2.3
2.6
2.8
3.1
3.4
3.7
4

Maintenance notes

Check whether the maintenance area or the room area meet the requirement of the

nameplate.
- It’s only allowed to be operated in the rooms that meet the requirement of the

nameplate.

Check whether the maintenance area is well-ventilated.

- The continuous ventilation status should be kept during the operation process.
Check whether there is fire source or potential fire source in the maintenance area.

- The naked flame is prohibited in the maintenance area; and the “no smoking”

warning board should be hanged.

Check whether the appliance mark is in good condition.

- Replace the vague or damaged warning mark.

Welding

If you should cut or weld the refrigerant system pipes in the process of maintaining, 
please follow the steps as below:

24

Sayfa 29

Safety operation of flammable refrigerant

a. Shut down the unit and cut power supply
b. Eliminate the refrigerant
c. Vacuuming
d. Clean it with N2 gas
e. Cutting or welding
f. Carry back to the service spot for welding

The refrigerant should be recycled into the specialized storage tank.

Make sure that there isn’t any naked flame near the outlet of the vacuum pump
and it’s well-ventilated.

Filling the refrigerant

Use the refrigerant filling appliances specialized for R32. Make sure that different

kinds of refrigerant won’t contaminate with each other.

The refrigerant tank should be kept upright at the time of filling refrigerant.

Stick the label on the system after filling is finished (or haven’t finished).
Don’t overfilling.

After filling is finished, please do the leakage detection before test running; another

time of leak detection should be done when it’s removed.

Safety instructions for transportation and storage

Please use the flammable gas detector to check before unload and open the container.

No fire source and smoking.
According to the local rules and laws.

25

Sayfa 30

Installation dimension diagram

Away from wall (30cm
at least for piping side)

Away from 

10cm above

ceiling

30cm

200cm above

Away from obstacles

FAN

ON/OFF

FUNC.

MODE

Away from wall (30cm at
least for piping side)

10cm above

from back side
Away 

5cm above

Space to the obstruction

obs
Space to the 

uction

At least 50cm

tr

At least 

0cm

3

At least 30cm

Space to the wall

At least 50cm

Space to the
obstruction

Space to the obstruction

At least 200cm

Drainage pipe

26

Sayfa 31

Safety precautions for installing and relocating the unit

To ensure safety, please be mindful of the following precautions. 

Warning
When installing or relocating the unit, be sure to keep the refrigerant 
circuit free from air or substances other than the specified refrigerant.
Any presence of air or other foreign substance in the refrigerant circuit will cause 
system pressure rise or compressor rupture, resulting in injury.

When installing or moving this unit, do not charge the refrigerant which 
is not comply with that on the nameplate or unqualified refrigerant.
Otherwise, it may cause abnormal operation, wrong action, mechanical 
malfunction or even series safety accident.
When refrigerant needs to be recovered during relocating or repairing the 
unit, be sure that the unit is running in cooling mode.Then, fully close the 
valve at high pressure side (liquid valve).About 30-40 seconds later, fully 
close the valve at low pressure side (gas valve), immediately stop the unit 
and disconnect power. Please note that the time for refrigerant recovery 
should  not exceed 1 minute. 
If refrigerant recovery takes too much time, air may be sucked in and cause 
pressure rise or compressor rupture, resulting in injury. 
During refrigerant recovery, make sure that liquid valve and gas valve are 
fully closed and power is disconnected before detaching the connection pipe. 
If compressor starts running when stop valve is open and connection pipe is not 
yet connected, air will be sucked in and cause pressure rise or compressor 
rupture, resulting in injury.

When installing the unit, make sure that connection pipe is securely 
connected before the compressor starts running.
If compressor starts running when stop valve is open and connection pipe is not 
yet connected, air will be sucked in and cause pressure rise or compressor 
rupture, resulting in injury.

Prohibit installing the unit at the place where there may be leaked corrosive 
gas or flammable gas.
If there leaked gas around the unit, it may cause explosion and other accidents. 

Do not use extension cords for electrical connections. If the electric wire 
is not long enough, please contact a local service center authorized  
and ask for a proper electric wire.
Poor connections may lead to electric shock or fire.
Use the specified types of wires for electrical connections between the 
indoor and outdoor units. Firmly clamp the wires so that their terminals 
receive no external stresses.
Electric wires with insufficient capacity, wrong wire connections and insecure 
wire terminals may cause electric shock or fire.

27

Sayfa 32

Tools for installation

1 Level meter
2 Screw driver
3 Impact drill

4 Drill head
5 Pipe expander
6 Torque wrench

7 Open-end wrench
8 Pipe cutter
9 Leakage detector

10 Vacuum pump
11 Pressure meter
12 Universal meter

13 Inner hexagon spanner
14 Measuring tape

Note:
● Please contact the local agent for installation.
●Don't use unqualified power cord.

Selection of installation location

Basic requirements

Indoor unit
Installing the unit in the following pla-

ces may cause malfunction. If it is u-
navoidable, please consult the local
dealer:

vapors, flammable or explosive gas,
1. The place near strong heat sources

or volatile objects spread in the air.
2. The place with high-frequency dev-
ices (such as welding machine,
medical equipment).
3. The place near coast area.
4. The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circums-
tances.
7. Please try your best to keep way
from fluorescent lamp.
8.It’s not allowed to be installed on the
unstable or motive base structure (such
as truck) or in the corrosive environ-
ment (such as chemical factory).

Outdoor unit

1. Select a location where the noise and outflow air emitted by the outdoor unit

will not affect neighborhood.

2. The location should be well ventilated and dry, in which the outdoor unit won't

be exposed directly to sunlight or strong wind.

3. The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirement of installation dimen-

sion diagram.

5. Select a location which is out of reach for children and far away from animals

or plants. If it is unavoidable, please add fence for safety purpose.

5m. The length of connection pipe should be within 10m.
6. The height difference between indoor unit and outdoor unit should be within

1. Avoid installing the indoor unit in a place
where generated or leaked inflammable
gas will stay.
2. Avoid installing the indoor unit in a moist
place or in a place where oil may be
splashed on the unit.
3. Select a location where outlet air may
reach each corner of the room.
4. Select a location where connection pipe
can be led to outdoor conveniently.

5. Select a location where air inlet and

outlet won't be blocked.

6. Select a location with least affection of

outdoor air.

7. Select a location with firm and flat floor.
8. Retain sufficient space for maintenance

and installation.

9. Ensure the installation meets the requir-

ement of installation dimension diagram.

10. Do not use the unit in the immediate

surroundings of a laundry a bath a
shower or a swimming pool.

28

Sayfa 33

Requirements for electric connection

Safety precaution

1.

Must follow the electric safety regulations when installing the unit.

air switch.
Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring or malfunction. Please install proper
power supply cables before using the air conditioner.
Properly connect the live wire, neutral wire and grounding wire of power socket.
Be sure to cut off the power supply before proceeding any work related to
electricity and safety. For models with a power plug, make sure the plug is
within reach after installation.

3.

4.
5.

7.

If the supply cord is damaged, it must be replaced by the manufacturer, its

8.

The temperature of refrigerant circuit will be high, please keep the interconnec-
tion cable away from the copper tube.

9. 
10.
2

The appliance shall be installed in accordance with national wiring regulations.

Appliance shall be installed, operated and stored in a room with a floor area
larger than Xm . (Please refer to table "a" in section of " Safety operation of

flammable refrigerant " for Space X.)

Please notice that the unit is filled with flammable gas R32. Inappropriate
treatment of the unit involves the risk of severe damages of people and
material. Details to this refrigerant are found in chapter “refrigerant”.

Grounding requirement

    grounding with specialized grounding device by a professional. Please make 
    sure it is always grounded effectively, otherwise it may cause electric shock.

2.

The yellow-green wire in air conditioner is grounding wire, which can't be used
    for other purposes.

3.
4.
5.

The grounding resistance should comply with national electric safety regulations.
The appliance must be positioned so that the plug is accessible.
An all-pole disconnection switch having a contact separation of at least 3mm in

6. Including an air switch with suitable capacity, please note the following table. Air
switch should be included magnet buckle and heating buckle function, it can
protect the circuit-short and overload. (Caution: please do not use the fuse only
for protect the circuit)

Air-conditioner

Air switch capacity

32K
25A

29

Sayfa 34

Installation of indoor unit

Step one: choosing installation location

Recommend the installation location to the client and then confirm it with the client.

Step two: open piping hole

1. Choose the position of piping hole according to the direction of outlet pipe.
2. Open a piping hole with the diameter of Ф70 on the selected outlet pipe
position. In order to drain smoothly, slant the piping hole on the wall slightly
downward to the outdoor side with the gradient of 5-10°.

   Note:
●Pay attention to dust prevention and
take relevant safety measures when
opening the hole.

Step three: outlet pipe

1. The pipe can be led out in the
2. After confirming the direction of outlet pipe,
loosen the screws at the upper and lower
direction of left, right or rear.

left
back
right
upper and lower adjusting baffle

Step four: connect the pipe of indoor unit
1. Take out the left and right screw cover and then remove the screws on air-inlet
panel to remove the panel.
screw

Indoor

outdoor

Φ70

5-10

adjusting baffle to let the connection pipe
/drain pipe connects the indoor unit.

left
back
right

air-inlet panel

30

Sayfa 35

Installation of indoor unit

2.

Aim the pipe joint at the correspo-

nding bellmouth.

pipe joint
union nut pipe

3.

Pretighten the union nut with hand.
4.

Adjust the torque force by referring to
5.

Wrap the indoor pipe and joint of
connection pipe with insulating pipe,
and then wrap it with tape.
the following sheet. Place the open-
end wrench on the pipe joint and
place the torque wrench on the
union nut. Tighten the union nut

with torque wrench.

Step five: install drain hose
1. Connect the drain hose to the

outlet pipe of indoor unit.

drain hose
outlet pipe

2. Bind the joint with tape.

1.
Step six: connect wire of indoor unit

Make the power connection wire go

power connection wire
through the cable-cross hole of
indoor unit and then pull it out.

open-end wrench

union nut

pipe

torque wrench

indoor pipe

Hex nut diameter
Tightening torque (N.m)

1/4''
29.4 (3.0kg.m)
49.0 (5.0kg.m)

15.7 (1.6kg.m)
3/8''
1/2''
5/8''

73.6 (7.5kg.m)

insulating pipe

drain hose

outlet pipe

tape

Note:
●Add insulating pipe in the indoor drain
hose in order to prevent condens-
ation.

drain hose

insulating pipe

cable-cross hole

31

Sayfa 36

2. Remove the wire clip; connect the power connection wire to the wiring terminal
Installation of indoor unit

according to the color; tighten the screw and then fix the power connection wire
with wire clip.

3.

Adjust the position of upper and lower adjusting baffle; clamp the connection
pipe and drain pipe as firm as possible.

4. Tighten the screws.

Note:

All wires of indoor unit and outdoor unit should be connected by a professional.

●If the length of power connection wire is insufficient, please contact the supplier

for a new one. Avoid extending the wire by yourself.

●
installation.

For the air conditioner with plug, the plug should be reachable after finishing

●For the air conditioner without plug, an air switch must be installed in the line.
The air switch should be all-pole parting and the contact parting distance
should be more than 3mm.

1.
Step seven: bind up pipe

Bind up the connection pipe, power cord and drain hose with the band.

3

N(1)
2

blue
black
yellow-
green

brown

Outdoor unit connection

indoor unit

indoor and outdoor power cord
gas pipe

liquid pipe

drain hose
band

32

Sayfa 37

Installation of indoor unit

2. Reserve a certain length of drain hose and power cord for installation when
binding them. When binding to a certain degree, separate the indoor power and
then separate the drain hose.

drain hose
band
connection pipe

indoor power cord

3. Wrap it evenly, and rolling width should be 1/3 of bandaging belt. Do not wrap it

4. The liquid pipe and gas pipe should be bound separately at the end.
too tight or too loose.

Note:
●The power cord and control wire can't be crossed or winding.
●The drain hose should be bound at the bottom.

Step eight: place the indoor unit

hole.
1. Put the bound pipes in the wall pipe and then make them pass through the wall

2. Stuff the gap between pipes and wall hole with sealing gum.
3. Fix the wall pipe.

indoor
outdoor

Note:
●Do not bend the drain hose too
excessively in order to prevent
blocking.

wall pipe

sealing gum

33

Sayfa 38

Installation of outdoor unit

(select it according to the actual installation situation)

1.
2.

Select installation location according to the house structure.
Fix the support of outdoor unit on the selected location with expansion screws.

 Note:

   installing the outdoor unit.

Make sure the support can withstand at least
   four times of the unit weight.

The outdoor unit should be installed at least

joint. (for the model with heating tube, the 
installation height should be no less than 20cm.)

For the unit with cooling capacity of 2300W
~5000W, 6 expansion screws are needed;
for the unit with cooling capacity of 6000W
~8000W, 8 expansion screws are needed;
for the unit with cooling capacity of 10000W
~16000W, 10 expansion screws are needed.

Step two: install drain joint 

(Only for some models) 

Connect the outdoor drain joint into
1.

the hole on the chassis, as shown in
the picture below.

2. Connect the drain hose into the drain vent.

NOTE: As for the shape of drainage joint, 

please refer to the current product. 
Do not install the drainage joint in the 
severe cold area. Otherwise,it will be 
frosted and then cause malfunction. 

drain vent

chassis

Drain hose

outdoor drain joint

at least 3cm above the floor

1.

Place the outdoor unit on the
support.
Fix the foot holes of outdoor unit
with bolts.

2.

foot holes

foot holes

34

Sayfa 39

Installation of outdoor unit

Step four: connect indoor and outdoor pipes

1. Remove the front side plate or handle.
3.

Pretighten the union nut with
hand.

pipe joint

handle

union nut

2.
4.

Remove the screw cap of valve and
aim the pipe joint at the bellmouth of
pipe.

Tighten the union nut with torque
wrench by referring to the sheet
below.

liquid pipe

(N.m)
Hex nut diameter
Tightening torque

gas pipe
liquid
valve

1/4”
3/8”
1/2”

15.7 (1.6kg.m)

29.4 (3.0kg.m)
49 (5.0kg.m)
73.6 (7.5kg.m)

5/8”

gas valve

Step five: connect outdoor electric wire

1. Remove the wire clip; connect the power connection wire and signal control wire

ng unit to the wiring terminal according to the color;

fix them with screws.

N(1)

2

L(3)

yellow-
green

blue black brown blue
yellow-
green

brown

(black)

L
N
Indoor unit connection

POWER

35

Sayfa 40

Installation of outdoor unit

2. Fix the power connection wire and
signal control wire with wire clip
(only for cooling and heating unit).

Step six: neaten the pipes

1.

The pipes should be placed along the wall,
bent reasonably and hidden possibly. Min.
semidiameter of bending the pipe is 10cm.

2. If the outdoor unit is higher than the wall

hole, you must set a U-shaped curve in
the pipe before pipe goes into the room,
in order to prevent rain from getting into
the room.

Note:

●

T he through-wall height of drain hose
shouldn't be higher than the outlet
pipe hole of indoor unit.

●

The water outlet can't be placed in water
in order to drain smoothly.

The water outlet can't 
be placed in water

Note:
●After tightening the screw, pull the power

●
cord slightly to check if it is firm.
Never cut the power connection wire to
prolong or shorten the distance.

wall

U-shaped curve

drain hose

●

Slant the drain hose slightly downw-
ards. The drain hose can't be curved,
raised and fluctuant, etc.

The drain hose can't

be fluctuant

the drain hose can't
raise upwards.

The drain hose

can't be fluctuant

The water outlet
can't be fluctuant

36

Sayfa 41

Vacuum pumping

Use vacuum pump

1. Remove the valve caps on the liquid
valve and gas valve and the nut of
refrigerant charging vent.
2. Connect the charging hose of piezo-
meter to the refrigerant charging vent
of gas valve and then connect the
other charging hose to the
vacuum pump.
3. Open the piezometer completely
and operate for 10-15min to
check if the pressure of piezometer
remains in -0.1MPa.
4. Close the vacuum pump and maintain this
status for 1-2min to check if the pressure of
piezometer remains in -0.1MPa. If the
pressure decreases, there may be leakage.
5. Remove the piezometer, open the valve

core of liquid valve and gas valve completely
with inner hexagon spanner.

6. Tighten the screw caps of valves and refrigerant charging vent.
7. Reinstall the handle.

Leakage detection

1. With leakage detector
Check if there is leakage with leakage detector.

2. With soap water

If leakage detector is not available, please use soap water for leakage detection.

Apply soap water at the suspected position and keep the soap water for more
than 3min. If there are air bubbles coming out of this position, there's a leakage.

piezometer

Lo
Hi

gas valve

liquid valve

valve cap

vacuum pump

refrigerant charging vent

valve cap

nut of refrigerant charging vent

inner hexagon spanner

close

open

37

Sayfa 42

Check after installation

Items to be checked
Possible malfunction

Have you done the refrigerant leakage 
test?
(heating) capacity.

Is water drained well?
It may cause condensation and water 
dripping.

Is the voltage of power supply accord-
ing to the voltage marked on the
nameplate?

Is electric wiring and pipeline installed
correctly?

Is the unit grounded securely?
It may cause electric leakage.

Does the power cord follow the speci-
It may cause malfunction or damaging 
the parts.

Is there any obstruction in the air inlet 

and outlet?
(heating) capacity.

The dust and sundries caused during 
installation are removed?

The gas valve and liquid valve of 
connection pipe are open completely?
(heating) capacit

Is the inlet and outlet of piping hole 
been covered?

Test operation

1. Preparation of test operation
●The client approves the air conditioner.
●Specify the important notes for air conditioner to the client.
2. Method of test operation
●Put through the power, press ON/OFF button on the remote controller to start
operation.
●Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
●If the ambient temperature is lower than 16℃, the air conditioner can’t
start cooling.

The unit may drop, shake or emit noise.

It may cause condensation and water 
dripping.

It may cause malfunction or damaging 
the parts.

It may cause malfunction or damaging 
the parts.

It may cause malfunction or damaging 
the parts.

y.

It may cause insufficient cooling
(heating) capacity or waste electricity.

38

Sayfa 43

Installation instructions of anti-collapse chain

●In order to prevent accidental collapse of indoor unit, please install the

anti-collapse chain.

Installation steps:

1. Remove the screw of anti-collapse hole at the top cover of indoor unit

(see fig. 3);

2. Take out the anti-collapse chain and put it into the anti-collapse hole, and then

tighten it with screw (see fig. 4);

3. Fix the other end of anti-collapse chain on the wall with screw (ST4.2X38)

(see fig. 4).

Fix the other end on the wall with screw

Remove the screw at the top cover

Put this end into the hole
and then tighten it with screw

Anti-collapse hole

Fig. 3
Fig. 4

●The above fig may be different from the actual products; please refer to the

actual products.

39

Wall

Indoor unit

Sayfa 44

Configuration of connection pipe

1.

Standard length of connection pipe
●5m、7.5m、8m

2.

Min. length of connection pipe
For the unit with standard connection pipe of 5m, there is no limitation for the 
min. length of connection pipe. For the unit with standard connection pipe of 
7.5m and 8m, the min. length of connection pipe is 3m.
Max. length of connection pipe

3.

Sheet 1 Max. length of connection pipe 

Max. length of
connection pipe

capacity
capacity

5000Btu/h
(1465W)

24000Btu/h

15

(7032W)

7000Btu/h
(2051W)

28000Btu/h
(8204W)

15

9000Btu/h
(2637W)

36000Btu/h
(10548W)

15
30

12000Btu/h
(3516W)

42000Btu/h
(12306W)

20
30

18000Btu/h
(5274W)

48000Btu/h
(14064W)

25
30

4.

The calculation method of additional refrigerant oil and refrigerant charging amount
after prolonging connection pipe
After the length of connection pipe is prolonged for 10m at the basis of standard
length, you should add 5ml of refrigerant oil for each additional 5m of connection
pipe.
The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe):

(1) Additional refrigerant charging amount= prolonged length of liquid pipe × additional

refrigerant charging amount per meter
(2) Basing on the length of standard pip e, add refrigerant according to the 

requirement as shown in the table.  The additional refrigerant charging amount 
       per meter is different according to the diameter of liquid pipe. See Sheet 2.

40

Unit: m

Max. length of
connection pipe

25

30

Sayfa 45

Configuration of connection pipe

Sheet 2. Additional refrigerant charging amount for R32

Piping size

Indoor unit throttle
Outdoor unit throttle

Cooling only
Cooling only,
cooling and heating

cooling and

Liquid pipe
Gas pipe

heating

(g / m)
(g / m)

(g / m)

1/4''

3/8'' or 1/2''

16

12

16

1/4'' or 3/8''

5/8'' or 3/4''

40

12

40

1/2''

3/4'' or 7/8''

80

24

96

5/8''

1'' or 1 1/4''

136

48

96

_

3/4''

200
200

200

7/8''
_

280
280

280

value, not compulsory.
Note: The additional refrigerant charging amount in Sheet 2 is recommended

5. If the outdoor unit is higher than the indoor unit for more than 5m, an oil return
bend is needed.

outdoor unit

outdoor unit

oil return bend

indoor unit
indoor unit

Below 5m
Above 5m

41

Sayfa 46

Pipe expanding method

Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand
the pipe according to the following steps:

A: Cut the pipe

E: Expand the port
●Expand the port with expander.

   the distance of indoor unit and 
   outdoor unit.
●Cut the required pipe with pipe cutter.
pipe

hard
mold

expander

pipe

pipe cutter

Note:
●"A" is different according to the
   diameter, please refer to the sheet 
   below:

leaning
uneven
burr

A(mm)

Outer diameter

B: Remove the burrs
●Remove the burrs with shaper and
   prevent the burrs from getting into 
   the pipe.

(mm)

Max
Min

Φ6-6.35(1/4") 

1.3
0.7

Φ9-9.52(3/8")

1.6
1.0

pipe

Φ12-12.7(1/2")

1.8
1.0

shaper

Φ15.8-16(5/8")

2.4
2.2

downwards

F: Inspection
●Check the quality of expanding port.
    If there is any blemish, expand the 
    port again according to the steps 
    above.

C: Put on suitable insulating pipe
D: Put on the union nut
●Remove the union nut on the indoor
   connection pipe and outdoor valve; 
   install the union nut on the pipe.

smooth surface

improper expanding

union pipe

leaning
damaged

crack
uneven
thickness

surface

pipe

the length is equal

42

Sayfa 47

Specialist’s Manual

The following checks shall be applied to installations using flammable refrig-
erants:

– the charge size is in accordance with the room size within which the refrigerant
containing parts are installed;
–

the ventilation machinery and outlets are operating adequately and are not

obstructed;
–

if an indirect refrigerating circuit is being used, the secondary circuit shall be

checked for the presence of refrigerant;

– marking to the equipment continues to be visible and legible. Markings and signs
that are illegible shall be corrected;
– refrigeration pipe or components are installed in a position where they are unlikely

to be exposed to any substance which may corrode refrigerant containing compo-
nents, unless the components are constructed of materials which are inherently 
resistant to being corroded or are suitably protected against being so corroded.
Repair and maintenance to electrical components shall include initial safety 
checks and component inspection procedures. If a fault exists that could 
compromise safety, then no electrical supply shall be connected to the circuit 
until it is satisfactorily dealt with. If the fault cannot be corrected immediately 
but it is necessary to continue operation, an adequate temporary solution 
shall be used. This shall be reported to the owner of the equipment so all 
parties are advised.
Initial safety checks shall include:

–
bility of sparking;
–

that capacitors are discharged: this shall be done in a safe manner to avoid possi-

that no live electrical components and wiring are exposed while charging, recover-

ing or purging the system;
– that there is continuity of earth bonding.

Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety 
checks are necessary to ensure that the risk of ignition is minimised. For repair to 
the refrigerating system, DD.4.3 to DD.4.7 shall be completed prior to conducting 
work on the system.
Work procedure
Work shall be undertaken under a controlled procedure so as to minimise the risk of 
a flammable gas or capour being present while the work is being performed.
General work area
All maintenance staff and others working in the local area shall be instructed on the 
nature of work being carried out. Work in confined spaces shall be avoides.

43

Sayfa 48

Specialist’s Manual

Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and 
during work, to ensure the technician is aware of potentially toxic or flammable 
atmospheres. Ensure that the leak detection equipment being used is suitable for 
use with all applicable refrigerants, i.e. non-sparking, adequately sealed or intrinsi-
cally safe.
Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated 
parts, appropriate fire extinguishing equipment shall be available to hand. Have a 
dry powder or CO2 fire extinguisher adjacent to the charging area.
Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before breaking 
into the system or conducting any hot work. A degree of ventilation shall continue 
during the period that the work is carried out. The ventilation should safely disperse 
any released refrigerant and preferably expel it externally into the atmosphere.
Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the purpose 
and to the correct specification. At all times the manufacturer's maintenance and 
service guidelines shall be followed. If in doubt, consult the manufacturer's technical 
department for assistance.
Checks to electrical devices

–
bility of sparking; 
–

that capacitors are discharged: this shall be done in a safe manner to avoid possi-

that no live electrical components and wiring are exposed while charging, recover-

ing or purging the system.
No ignition sources
No person carrying out work in relation to a refrigerating system which involves 
exposing any pipe work shall use any sources of ignition in such a manner that it 
may lead to the risk of fire or explosion. All possible ignition sources, including 
cigarette smoking, should be kept sufficiently far away from the site of installation, 
repairing, removing and disposal, during which refrigerant can possibly be released 
to the surrounding space. Prior to work taking place, the area around the equipment 
is to be surveyed to make sure that there are no flammable hazards or ignition risks. 
''No Smoking'' signs shall be displayed.
Repairs to sealed components
During repairs to sealed components, all electrical supplies shall be disconnected 
from the equipment being worked upon prior to any removal of sealed covers, etc. 
If it is absolutely necessary to have an electrical supply to equipment during servic-
ing, then a permanently operating form of leak detection shall be located at the most 
critical point to warn of a potentially hazardous situation.
Particular attention shall be paid to the following to ensure that by working on 
electrical components, the casing is not altered in such a way that the level of 
protection is affected. This shall include damage to cables, excessive number of 
connections, terminals not made to original specification, damage to seals, incor-

44

Sayfa 49

Specialist’s Manual

rect fitting of glands, etc.
– Ensure that the apparatus is mounted securely.
– Ensure that seals or sealing materials have not degraded to the point that they no
longer serve the purpose of preventing the ingress of flammable atmospheres. 
Replacement parts shall be in accordance with the manufacturer’s specifications.
NOTE: The use of silicon sealant can inhibit the effectiveness of some types of leak 
detection equipment. Intrinsically safe components do not have to be isolated prior 
to working on them.
Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the circuit without 
ensuring that this will not exceed the permissible voltage and current permitted for 
the equipment in use.
Intrinsically safe components are the only types that can be worked on while live in 
the presence of a flammable atmosphere. The test apparatus shall be at the correct 
rating.
Replace components only with parts specified by the manufacturer. Other parts 
may result in the ignition of refrigerant in the atmosphere from a leak.
Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure, vibra-
tion, sharp edges or any other adverse environmental effects. The check shall also 
take into account the effects of aging or continual vibration from sources such as 
compressors or fans.
Leak detection methods
Leak detection fluids are suitable for use with most refrigerants but the use of deter-
gents containing chlorine shall be avoided as the chlorine may react with the refrig-
erant and corrode the copper pipe-work.
Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the searching 
for or detection of refrigerant leaks. A halide torch (or any other detector using a 
naked flame) shall not be used.
The following leak detection methods are deemed acceptable for all refrigerant 
systems.
Electronic leak detectors may be used to detect refrigerant leaks but, in the case of 
flammable refrigerants, the sensitivity may not be adequate, or may need re-cali-
bretion. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure 
that the detector is not a potential source of ignition and is suitable for the refrigerant 
used. Leak detection equipment shall be set at a percentage of the LFL of the reftig-
erant and shall be calibrated to the refrigerant employed, and the appropriate 
percentage of gas (25% maximum) is confirmed.
Leak detection fluids are also suitable for use with most refrigerants but the use of 
detergents containing chlorine shall be avoided as the chlorine may react with the 
refrigerant and corrode the copper pipe-work.
NOTE: Examples of leak detection fluids are
- bubble method,
- fluorescent method agents.

45

Sayfa 50

Specialist’s Manual

If a leak is suspected, all naked flames shall be removed/extinguished.
If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall 
be recovered from the system, or isolated (by means of shut off valves) in a part of 
the system remote from the leak. Removal of refrigerant shall be according to 
clause DD.9.
Removel and evacuation
When breaking into the refrigerant circuit to make repairs - or for any other purpose 
- conventional procedures shall be used. However, for flammable refrigerants it is 
important that best practice is followed sinse flammability is a consideration. The 
following procedure shall be adhered to:

   remove refrigerant;
   purge the circuit with inert gas (optional for A2L);
   evacuate (optional for A2L);
   purge with inert gas (optional for A2L);
   open the circuit by cutting or brazing.

The refrigerant charge shall be recovered into the correct tecovery cylinders. For 
appliances containing flammable refrigerants other than A2L refrigerants, the 
system shall be perged process may need to be repeated several times. Com-
pressed air or oxygen shall not be used for purging refrigerant systems.
For appliances containing flammable refrigerants, other than A2L refrigerants, 
refrigerants purging shall be achieved by breaking the vacuum in the system with 
oxygen-free nitrogen and continuing to fill until the working pressure is achieved, 
then venting to atmosphere, and finally pulling down to a vacuum. This process 
shall be repeated until no refrigerant is within the system. When the final 
oxygen-free nitrogen charge is used, the system shall be vented down to atmo-
spheric pressure to enable work to take place. This operation is absolutely vital if 
brazing operations on the pipe-work are to take place.
Ensure that the outlet for the vacuum pump is not close to any potential ignition 
sources and that ventilation is available.
Charging procedures
In additon to conventional charging procedures, the following requirements shall be 
followed.

   Ensure that contamination of different refrigerants does not occur when using 
charging equipment. Hoses or lines shall be as short as possible to minimise the 
amount of refrigerant contained in them.

   Cylinders shall be kept in an appropriate position according to the instructions.

   Ensure that the refrigerating system is earthed prior to charging the system with 
refrigerant.

   Label the system when charging is complete (if not already).
   Extreme care shall be taken not to overfill the refrigerating system.

Prior to recharging the system, it shall be pressure-tested with the appropriate purg-
ing gas. The system shall be leak-tested on completion of charging but prior to com-
missioning. A follow up leak test shall be carried out prior to leaving the site.
Decommissioning
Before carrying out this procedure, it is essential that the technician is completely 

46

Sayfa 51

Specialist’s Manual

familiar with the equipment and all its detail. It is recommended good practice that 
all refrigerants are recovered safely. Prior to the task being carried out, an oil and 
refrigerant sample shall be taken in case analysis is required prior to reuse of 
reclaimed refrigerant. It is essential that electrical power is available before the task 
is commenced.

a) Become familiar with the equipment and its operation.
b) Isolate system electrically.
c) Before attempting the procedure, ensure that:
–
cylinders;
– all personal protective equipment is available and being used correctly;
– the recovery process is supervised at all times by a competent person;

mechanical handling equipment is available, if required, for handling refrigerant

– recovery equipment and cylinders conform to the appropriate standards.
d) Pump down refrigerant system, if possible.
e)

If a vacuum is not possible, make a manifold so that refrigerant can be removed

from various parts of the system.
f)

Make sure that cylinder is situated on the scales before recovery takes place.
g)
instructions.
h) Do not overfill cylinders. (No more than 80% volume liquid charge).

Start the recovery machine and operate in accordance with manufacturer's

i ) Do not exceed the maximum working pressure of the cylinder, even temporarily.
j ) When the cylinders have been filled correctly and the process completed, make 
sure that the cylinders and the equipment are removed from site promptly and all 
isolation valves on the equipment are closed off.

k)
unless it has been cleaned and checked.
Labelling

Recovered refrigerant shall not be charged into another refrigeration system

Equipment shall be labelled stating that it has been de-commissioned and emptied 
of refrigerant. The label shall be dated and signed. For appliances containing flam-
mable refrigerants, ensure that there are labels on the equipment stating the equip-

ment contains flammable refrigerant.
Recovery
When removing refrigerant from a system, either for servicing or decommissioning, 
it is recommended good practice that all refrigerants are removed safely.

When transferring refrigerant into cylinders, ensure that only appropriate refrigerant 
recovery cylinders are employed. Ensure that the correct number of cylinders for 
holding the total system charge are available. All cylinders to be used are designat-
ed for the recovered refrigerant and labelled for that refrigerant (i.e. special cylin-
ders for the recovery of refrigerant). Cylinders shall be complete with pressure-re- 
lief valve and associated shut-off valves in good working order. Empty recovery 
cylinders are evacuated and, if possible, cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions 
concerning the equipment that is at hand and shall be suitable for the recovery of all 
appropriate refrigerants including, when applicable, flammable refrigerants. In ad- 
dition, a set of calibrated weighing scales shall be available and in good working 

47

Sayfa 52

Specialist’s Manual

order. Hoses shall be complete with leak-free disconnect couplings and in good 
condition. Before using the recovery machine, check that it is in satisfactory working 
order, has been properly maintained and that any associated electrical components 
are sealed to prevent ignition in the event of a refrigerant release. Consult manufac-
turer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct 
recovery cylinder, and the relevant waste transfer note arranged. Do not mix refrig-
erants in recovery units and especially not in cylinders.
If compressors or compressor oils are to be removed, ensure that they have been 
evacuated to an acceptable level to make certain that flammable refrigerant does 
not remain within the lubricant. The evacuation process shall be carried out prior to 
returning the compressor to the suppliers. Only electric heating to the compressor 
body shall be employed to accelerate this process. When oil is drained from a 
system, it shall be carried out safely. 

48

Sayfa 53

GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

 Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 
Tel: (+86-756) 8522218         
Fax: (+86-756) 8669426
E-mail: global@cn.gree.com  
Web: www.gree.com

600005065881