Change for life

Owner's Manual

Original Instructions

Console Type Air Conditioner

Thank you for choosing our product.
Please read this Owner’s Manual carefully before operation and 
retain it for future reference.
If you have lost the Owner's Manual, please contact the local agent 
or visit www.gree.com or send an email to global@cn.gree.com for
the electronic version.

Sayfa 2

GEH09AA-K6DNA1F/O
GEH12AA-K6DNA1A/O
GEH18AA-K6DNA1F/O

Sayfa 3

Content
Operation Notices

Precautions............................................................................................................2
The Refrigerant......................................................................................................1

Parts name............................................................................................................7

Installation Notice

Safety operation of flammable refrigerant.............................................................8

Installation dimension diagram ............................................................................10

Safety precautions for installing and relocating the unit.......................................11

Tools for installation .............................................................................................12
Selection of installation location ..........................................................................12
Requirements for electric connection ..................................................................13

Installation
Installation of outdoor unit ...................................................................................14
Vacuum pumping .................................................................................................17
Leakage detection ...............................................................................................17
Check after installation ........................................................................................18

Test and operation
Test operation ......................................................................................................18

Attachment

Configuration of connection pipe
Pipe expanding method .......................................................................................21
Specialist’s Manual ..............................................................................................22

This appliance is not intended for use by persons (including children) with reduced physical, sensory 
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision 
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.

This marking indicates that this product should not be disposed with other household wastes
throughout the EU. To prevent possible harm to the environment or human health from un-
controlled waste disposal, recycle it responsibly to promote the sustainable reuse of mate-
rial resources. To return your used device, please use the return and collection systems or 
contact the retailer where the product was purchased. They can take this product for envi-
ronmental safe recycling.

R32: 675

.........................................................................19

Sayfa 4

Explanation of Symbols

DANGER

WARNING

CAUTION

NOTICE

Exception Clauses

Manufacturer will bear no responsibilities when personal injury or 
property loss is caused by the following reasons.

1.Damage the product due to improper use or misuse of the product;

2.Alter, change, maintain or use the product with other equipment without abiding

by the instruction manual of manufacturer;

After verification, the defect of product is directly caused by corrosive gas;
3.

After verification, defects are due to improper operation during transportation of
product;
4.

Operate, repair, maintain the unit without abiding by instruction manual or related
regulations;
5.

After verification, the problem or dispute is caused by the quality specification or
performance of parts and components that produced by other manufacturers;
6.

The damage is caused by natural calamities, bad using environment or force
majeure.
7.

If it needs to install, move or maintain the air conditioner, please contact dealer 
or local service center to conduct it at first. Air conditioner must be installed, 
moved or maintained by appointed  unit. Otherwise, it may cause serious 
damage or personal injury or death.
When refrigerant leaks or requires discharge during installation, maintenance, 
or disassembly, it should be handled by certified professionals or otherwise in 
compliance with local laws and regulations.

Indicates a hazardous situation that, if not avoided, will
result in death or serious injury.  

Indicates a hazardous situation that, if not avoided, could 
result in death or serious injury. 

Indicates a hazardous situation that, if not avoided, may
result in minor or moderate injury.  

Indicates important but not hazard-related information, 
used to indicate risk of property damage. 

Indicates a hazard that would be assigned a signal word 
WARNING or CAUTION.

Sayfa 5

Please read this operating manual carefully before operating the unit.

to the material objects for reference.

The Refrigerant
●To realize the function of the air conditioner unit, a special refrigerant circulates
. 
lead to explosion 

●Compared to common refrigerants, R32 is a nonpolluting refrigerant with no

lower. R32 has got very good thermodynamic features which lead to a really high

WARNING:
Do not use means to accelerate the defrosting process or to clean, other than 
those recommended by the manufacture.Should repair be necessary, contact your 
nearest authorized Service Centre.

The appliance shall be stored in a room without continuously operating ignition 

electric heater.)
Do not pierce or burn.

Appliance shall be installed, operated and stored in a room with a floor area larger

than “X”m  .(Please refer to table "a" in section of " Safety operation of flammable
refrigerant " for Space X.)

2

’s 
instructions only.
Be aware that refrigerants may not contain an odour. 
Read specialist’s manual.

1

. It can 

Sayfa 6

Precautions

Operation and Maintenance

This appliance can be used by children aged from 8 
years and above and persons with reduced physical, 
sensory or mental capabilities or lack of experience 
and knowledge if they have been given supervision or 
instruction concerning use of the appliance in a safe 

Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by 
children without supervision.

conditioner. Otherwise, it may cause electric shock.
If the supply cord is damaged, it must be replaced by 

electric shock.

shock or malfunction.

2

Sayfa 7

Precautions

Maintenance must be performed by qualified 
professionals. Otherwise, it may cause personal injury 
or damage.

Do not repair air conditioner by yourself. It may cause 

electric shock or damage. Please contact dealer when 
you need to repair air conditioner. 

Do not extend fingers or objects into air inlet or air 

outlet. It may cause personal injury or damage.

Do not block air outlet or air inlet. It may cause 
malfunction.

Do not spill water on the remote controller, otherwise the 

remote controller may be broken.

When below phenomenon occurs, please turn off air 

conditioner and disconnect power immediately, and then 

contact the dealer or qualified professionals for service.

●Power cord is overheating or damaged.

●There’s abnormal sound during operation.

●Circuit break trips off frequently.

●Air conditioner gives off burning smell.

●Indoor unit is leaking.

If the air conditioner operates under abnormal conditions, 
it may cause malfunction, electric shock or fire hazard.

When turning on or turning off the unit by emergency 
operation switch, please press this switch with an insulating 
object other than metal.

objects. It may cause damage or personal injury.
Do not step on top panel of outdoor unit, or put heavy 

WARNING

3

Sayfa 8

Precautions

Attachment

Installation must be performed by qualified professionals. 
Otherwise, it may cause personal injury or damage.

Must follow the electric safety regulations when installing 
the unit.

According to the local safety regulations, use qualified 

power supply circuit and circuit break.

Do install the circuit break. If not, it may cause malfunction. 

An all-pole disconnection switch having a contact separation 

of at least 3mm in all poles should be connected in fixed 
wiring.

Including an circuit break with suitable capacity, please 

note the following table. Air switch should be included 

magnet buckle and heating buckle function, it can protect
the circuit-short and overload.

Air Conditioner should be properly grounded. Incorrect 

Don't use unqualified power cord.
grounding may cause electric shock.

Make sure the power supply matches with the requirement 
of air conditioner. Unstable power supply or incorrect wiring
may result in electric shock, fire hazard or malfunction.
Please install proper power supply cables before using the
air conditioner.

grounding wire of power socket.
Properly connect the live wire, neutral wire and 

any work related to electricity and safety.
Be sure to cut off the power supply before proceeding 

WARNING

4

Sayfa 9

Precautions

Do not put through the power before finishing installation.

the manufacturer, its service agent or similarly qualified 
If the supply cord is damaged, it must be replaced by 

persons in order to avoid a hazard.

The temperature of refrigerant circuit will be high, please 

keep the interconnection cable away from the copper 
tube.

The appliance shall be installed in accordance with 

national wiring regulations.

Installation must be performed in accordance with the 

requirement of NEC and CEC by authorized personnel 
only.

The air conditioner is the first class electric appliance. It 

must be properly grounding with specialized grounding 
device by a professional. Please make sure it is always 
grounded effectively, otherwise it may cause electric shock.

The yellow-green wire in air conditioner is grounding 

wire, which can't be used for other purposes.
The grounding resistance should comply with national 
electric safety regulations.

The appliance must be positioned so that the plug is 
accessible.

All wires of indoor unit and outdoor unit should be 
connected by a professional. 

If the length of power connection wire is insufficient, please 
contact the supplier for a new one. Avoid extending the 
wire by yourself.

WARNING

5

Sayfa 10

Precautions

reachable after finishing installation.
For the air conditioner with plug, the plug should be  

If you need to relocate the air conditioner to another 
must be installed in the line.
For the air conditioner without plug, an circuit break 

place, only the qualified person can perform the work. 
Otherwise, it may cause personal injury or damage.

Select a location which is out of reach for children and 

far away from animals or plants. If it is unavoidable, 
please add the fence for safety purpose.

The indoor unit should be installed close to the wall. 
Instructions for installation and use of this product are 
provided by the manufacturer.

Working temperature range

Indoor side DB/WB(℃)
Outdoor side DB/WB(℃)
Maximum cooling
32/23
43/26
Maximum heating
27/-
24/18

NOTICE:

● The operating temperature range (outdoor temperature) for cooling only unit is 
   -15℃~ 43℃; for heat pump unit is -22℃~ 43℃.

WARNING

6

Sayfa 11

Parts name

Indoor Unit

Outdoor Unit

NOTICE:
Actual product may be different from above graphics, please refer to actual 
products.

air inlet

Connection wire

air outlet

7

Sayfa 12

Safety operation of flammable refrigerant

Qualification requirement for installation and maintenance man

All the work men who are engaging in the refrigeration system should bear the
valid certification awarded by the authoritative organization and the qualification
for dealing with the refrigeration system recognized by this industry. If it needs
other technician to maintain and repair the appliance, they should be supervised
by the person who bears the qualification for using the flammable refrigerant.
It can only be repaired by the method suggested by the equipment’s manufacturer.

Installation notes

The air conditioner is not allowed to use in a room that has running fire (such as fire
source, working coal gas ware, operating heater).

It is not allowed to drill hole or burn the connection pipe.
The air conditioner must be installed in a room that is larger than the minimum room
area. The minimum room area is shown on the nameplate or following table a.
Leak test is a must after installation.

table a- Minimum room area ( m  )
2

Charge amount (kg) ≤1.2 1.3 1.4
1.5
1.6
1.7
1.8
1.9
2
2.1
2.2
2.3
2.4
2.5

floor location

/
14.5 16.8 19.3 22 24.8 27.8 31 34.3 37.8 41.5 45.4 49.4 53.6

Minimum

/

room

window mounted

5.2 6.1
7
7.9
8.9
10 11.2 12.4 13.6
15
16.3 17.8 19.3

2
area( m  )

wall mounted

/

1.6 1.9
2.1
2.4
2.8
3.1
3.4
3.8
4.2
4.6
5
5.5
6

ceiling mounted

/

1.1 1.3
1.4
1.6
1.8
2.1
2.3
2.6
2.8
3.1
3.4
3.7
4

Maintenance notes

Check whether the maintenance area or the room area meet the requirement of the

nameplate.
- It’s only allowed to be operated in the rooms that meet the requirement of the

nameplate.

Check whether the maintenance area is well-ventilated.

- The continuous ventilation status should be kept during the operation process.
Check whether there is fire source or potential fire source in the maintenance area.

- The naked flame is prohibited in the maintenance area; and the “no smoking”

warning board should be hanged.

Check whether the appliance mark is in good condition.

- Replace the vague or damaged warning mark.

Welding

If you should cut or weld the refrigerant system pipes in the process of maintaining, 
please follow the steps as below:

8

Sayfa 13

Safety operation of flammable refrigerant

a. Shut down the unit and cut power supply
b. Eliminate the refrigerant
c. Vacuuming
d. Clean it with N2 gas
e. Cutting or welding
f. Carry back to the service spot for welding

The refrigerant should be recycled into the specialized storage tank.

Make sure that there isn’t any naked flame near the outlet of the vacuum pump
and it’s well-ventilated.

Filling the refrigerant

Use the refrigerant filling appliances specialized for R32. Make sure that different

kinds of refrigerant won’t contaminate with each other.

The refrigerant tank should be kept upright at the time of filling refrigerant.

Stick the label on the system after filling is finished (or haven’t finished).
Don’t overfilling.

After filling is finished, please do the leakage detection before test running; another

time of leak detection should be done when it’s removed.

Safety instructions for transportation and storage

Please use the flammable gas detector to check before unload and open the container.

No fire source and smoking.
According to the local rules and laws.

9

Sayfa 14

Installation dimension diagram

Space to the obstruction

Space to the 

At least 50cm

obstruction

At least 

30cm

At least 30cm

Space to the wall

Space to the obstruction

At least 200cm

At least 50cm

Space to the 
obstruction

Drainage pipe

10

Sayfa 15

Safety precautions for installing and relocating the unit

To ensure safety, please be mindful of the following precautions. 

Warning
When installing or relocating the unit, be sure to keep the refrigerant 
circuit free from air or substances other than the specified refrigerant.
Any presence of air or other foreign substance in the refrigerant circuit will cause 
system pressure rise or compressor rupture, resulting in injury.

When installing or moving this unit, do not charge the refrigerant which 
is not comply with that on the nameplate or unqualified refrigerant.
Otherwise, it may cause abnormal operation, wrong action, mechanical 
malfunction or even series safety accident.
When refrigerant needs to be recovered during relocating or repairing the 
unit, be sure that the unit is running in cooling mode.Then, fully close the 
valve at high pressure side (liquid valve).About 30-40 seconds later, fully 
close the valve at low pressure side (gas valve), immediately stop the unit 
and disconnect power. Please note that the time for refrigerant recovery 
should  not exceed 1 minute. 
If refrigerant recovery takes too much time, air may be sucked in and cause 
pressure rise or compressor rupture, resulting in injury. 
During refrigerant recovery, make sure that liquid valve and gas valve are 
fully closed and power is disconnected before detaching the connection pipe. 
If compressor starts running when stop valve is open and connection pipe is not 
yet connected, air will be sucked in and cause pressure rise or compressor 
rupture, resulting in injury.

When installing the unit, make sure that connection pipe is securely 
connected before the compressor starts running.
If compressor starts running when stop valve is open and connection pipe is not 
yet connected, air will be sucked in and cause pressure rise or compressor 
rupture, resulting in injury.

Prohibit installing the unit at the place where there may be leaked corrosive 
gas or flammable gas.
If there leaked gas around the unit, it may cause explosion and other accidents. 

Do not use extension cords for electrical connections. If the electric wire 
is not long enough, please contact a local service center authorized  
and ask for a proper electric wire.
Poor connections may lead to electric shock or fire.
Use the specified types of wires for electrical connections between the 
indoor and outdoor units. Firmly clamp the wires so that their terminals 
receive no external stresses.
Electric wires with insufficient capacity, wrong wire connections and insecure 
wire terminals may cause electric shock or fire.

11

Sayfa 16

Tools for installation

1 Level meter
2 Screw driver
3 Impact drill

4 Drill head
5 Pipe expander
6 Torque wrench

7 Open-end wrench
8 Pipe cutter
9 Leakage detector

10 Vacuum pump
11 Pressure meter
12 Universal meter

13 Inner hexagon spanner
14 Measuring tape

Note:
●Please contact the local agent for installation.

Selection of installation location

Basic requirement

Installing the unit in the following places may cause malfunction. If it is un-
avoidable, please consult the local dealer:

1.The place with strong heat sources, vapors, flammable or explosive gas, or
volatile objects spread in the air.
2.The place with high-frequency devices (such as welding machine, medical
equipment).
3. The place near coast area.
4. The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circumstances.
7. The appliance shall not be installed in the laundry.

8. It’s not allowed to be installed on the unstable or motive base structure
(such as truck) or in  the corrosive environment (such as chemical factory).

Outdoor unit

    will not affect neighborhood.
2. The location should be well ventilated and dry, in which the outdoor unit

    won't be exposed directly to sunlight or strong wind.
3. The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirement of installation
dimension diagram.
5. Select a location which is out of reach for children and far away from animals
or plants.If it is unavoidable, please add the fence for safety purpose.

12

Sayfa 17

Requirements for electric connection

Safety precaution

1.

Must follow the electric safety regulations when installing the unit.

3.

Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring or malfunction. Please install proper
power supply cables before using the air conditioner.
Properly connect the live wire, neutral wire and grounding wire of power socket.
Be sure to cut off the power supply before proceeding any work related to
electricity and safety. For models with a power plug, make sure the plug is
within reach after installation.

4.
5.

7.

If the supply cord is damaged, it must be replaced by the manufacturer, its

The temperature of refrigerant circuit will be high, please keep the interconnec-
    tion cable away from the copper tube.
9. 
10.
The appliance shall be installed in accordance with national wiring regulations.

8.

Appliance shall be installed, operated and stored in a room with a floor area

larger than “X”m  (see table a).
    

2

Please notice that the unit is filled with flammable gas R32. Inappropriate
treatment of the unit involves the risk of severe damages of people and
material. Details to this refrigerant are found in chapter “refrigerant”.

Grounding requirement

    grounding with specialized grounding device by a professional. Please make 
    sure it is always grounded effectively, otherwise it may cause electric shock.

2.

The yellow-green wire in air conditioner is grounding wire, which can't be used
    for other purposes.

3.
4.
5.

The grounding resistance should comply with national electric safety regulations.
The appliance must be positioned so that the plug is accessible.
An all-pole disconnection switch having a contact separation of at least 3mm in

6.

Including an air switch with suitable capacity, please note the following table. Air
switch should be included magnet buckle and heating buckle function, it can
protect the circuit-short and overload. (Caution: please do not use the fuse only
for protect the circuit)

Air-conditioner
Circuit break capacity

09K

12K
16A
10A

18K

16A

13

air switch.

Sayfa 18

Installation of outdoor unit

(select it according to the actual installation situation)

1. Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion screws.

 Note:

   installing the outdoor unit.

Make sure the support can withstand at least
   four times of the unit weight.

●

●

The outdoor unit should be installed at least

joint. (for the model with heating tube, the 
installation height should be no less than 20cm.)

●For the unit with cooling capacity of 2300W

~5000W, 6 expansion screws are needed;
for the unit with cooling capacity of 6000W
~8000W, 8 expansion screws are needed;
for the unit with cooling capacity of 10000W
~16000W, 10 expansion screws are needed.

Step two: install drain joint 
(Only for some models)   
1.

Connect the outdoor drain joint into
the hole on the chassis, as shown in
the picture below.

2. Connect the drain hose into the drain vent.
foot holes

NOTE: As for the shape of drainage joint, 

please refer to the current product. 
Do not install the drainage joint in the 
severe cold area. Otherwise,it will be 
frosted and then cause malfunction. 

drain vent

chassis

Drain hose

outdoor drain joint

at least 3cm above the floor

1. Place the outdoor unit on the
support.
Fix the foot holes of outdoor unit
with bolts.
2.

foot holes

14

Sayfa 19

Installation of outdoor unit

Step four: connect indoor and outdoor pipes

3. Pretighten the union nut with hand.

1. Remove the screw on the right han-
    dle of outdoor unit and then remove 

the handle.

pipe joint

screw

union nut

handle

2. Remove the screw cap of valve and
aim the pipe joint at the bellmouth of
pipe.

4. Tighten the union nut with torque
wrench by referring to the sheet
below.

Hex nut diameter Tightening torque

liquid pipe

(N.m)
Φ 6
Φ 9.52

15~20

liquid
valve

gas pipe

30~40
45~55
60~65
70~75

Φ 12
Φ 16
Φ 19

gas valve

1. Remove the wire clip; connect the power connection wire and signal control
wire (only for cooling and heating unit) to the wiring terminal according to the

09、12K:
18K:

N(1)
2
3

N(1)
2
3 L     N

N
L

(black)
black
yellow-
green

blue
blue
brown brown

yellow-
green

blue
blue
black
yellow-
green

yellow-
green
brown
brown
(black)

L
N

N
L

Indoor unit connection
POWER

Indoor unit connection
POWER

Note: the wiring board is for reference only, please refer to the actual one

15

Sayfa 20

Installation of outdoor unit

2. Fix the power connection wire and signal control wire with wire clip (only for
cooling and heating unit).

Note:

●Never cut the power connection wire to prolong or shorten the distance.

Step six: neaten the pipes

1. The pipes should be placed along the wall, 
bent reasonably and hidden possibly. Min. 
semidiameter of bending the pipe is 10cm.

2. If the outdoor unit is higher than the wall
hole, you must set a U-shaped curve in the
pipe before pipe goes into the room, in
order to prevent rain from getting into the
room.

wall

U-shaped curve

drain hose

16

Sayfa 21

Vacuum pumping

Use vacuum pump

1. Remove the valve caps on
the liquid valve and gas
valve and the nut of refri-
    gerant charging vent.
2. Connect the charging hose
of piezometer to the refri-
    gerant charging vent of gas 
    valve and then connect the 
    other charging hose to the 
    vacuum pump.
3. Open the piezometer com-
    pletely and operate for 
    10-15min to check if the 
    pressure of piezometer re-
    mains in -0.1MPa.
4. Close the vacuum pump
and maintain this status for
1-2min to check if the pres-
    sure of piezometer remains 
    in -0.1MPa. If the pressure decreases, there may be leakage.
5. Remove the piezometer, open the valve core of liquid valve and gas valve
completely with inner hexagon spanner.
6. Tighten the screw caps of valves and refrigerant charging vent.
7. Reinstall the handle.

Leakage detection

1. With leakage detector:
Check if there is leakage with leakage detector.
2. With soap water:
If leakage detector is not available, please use soap water for leakage detection.
Apply soap water at the suspected position and keep the soap water for more

than 3min. If there are air bubbles coming out of this position, there's a leakage.

liquid valve

piezometer

Lo
Hi

gas valve

refrigerant 
charging vent

valve cap

nut of refrigerant
charging vent

vacuum pump

inner hexagon
spanner

close

open

17

Sayfa 22

Check after installation

Items to be checked
Possible malfunction

Have you done the refrigerant leakage 
test?
(heating) capacity.

Is water drained well?
It may cause condensation and water 
dripping.

Is the voltage of power supply accord-
ing to the voltage marked on the
nameplate?

Is electric wiring and pipeline installed
correctly?

Is the unit grounded securely?
It may cause electric leakage.

Does the power cord follow the speci-
It may cause malfunction or damaging 
the parts.

Is there any obstruction in the air inlet 
and outlet?
(heating) capacity.

The dust and sundries caused during 
installation are removed?

The gas valve and liquid valve of 
connection pipe are open completely?

Is the inlet and outlet of piping hole 
been covered?

Test operation

1. Preparation of test operation
●The client approves the air conditioner.
●Specify the important notes for air conditioner to the client.
2. Method of test operation
●Put through the power, press ON/OFF button on the remote controller to start
operation.
●Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
●If the ambient temperature is lower than 16℃, the air conditioner can’t
start cooling.

The unit may drop, shake or emit noise.

It may cause condensation and water 
dripping.

It may cause malfunction or damaging 
the parts.

It may cause malfunction or damaging 
the parts.

It may cause malfunction or damaging 
the parts.

(heating) capacity.

It may cause insufficient cooling
(heating) capacity or waster eletricity.

18

Sayfa 23

Configuration of connection pipe

1. Standard length of connection pipe
●5m、7.5m、8m

2. Min. length of connection pipe
For the unit with standard connection pipe of 5m, there is no limitation for the 
min. length of connection pipe. For the unit with standard connection pipe of 
7.5m and 8m, the min. length of connection pipe is 3m.

3. Max. length of connection pipe

Sheet 1 Max. length of connection pipe 
Unit: m

Max. length of
connection pipe

capacity
capacity

5000Btu/h
(1465W)

24000Btu/h
(7032W)

15
25

7000Btu/h
(2051W)

28000Btu/h
(8204W)

15
30

9000Btu/h
(2637W)

36000Btu/h
(10548W)

15
30

12000Btu/h
(3516W)

42000Btu/h
(12306W)

20
30

18000Btu/h
(5274W)

48000Btu/h
(14064W)

25
30

4. The calculation method of additional refrigerant oil and refrigerant charging amount
after prolonging connection pipe
After the length of connection pipe is prolonged for 10m at the basis of standard
length, you should add 5ml of refrigerant oil for each additional 5m of connection
pipe.
The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe):

(1) Additional refrigerant charging amount= prolonged length of liquid pipe × additional

refrigerant charging amount per meter

Basing on the length of standard pipe, add refrigerant according to the 
requirement as shown in the table.  The additional refrigerant charging amount 
       per meter is different according to the diameter of liquid pipe. See Sheet 2.

(2) 
 

19

Max. length of 
connection pipe

Sayfa 24

Configuration of connection pipe

Sheet 2. Additional refrigerant charging amount for R32

Diameter of connection pipe mm

Indoor unit throttle
Outdoor unit throttle

Cooling only,
cooling and heating

cooling and

Cooling only

Liquid pipe
Gas pipe

heating

(g / m)

(g / m)
(g / m)

Ф6

Ф9.5 or Ф12

16

12

16

Ф6 or Ф9.5

Ф16 or Ф19

40

12

40

Ф12

Ф19 or Ф22.2

80

24

96

Ф16

Ф25.4 or Ф31.8

136

48

96

_

Ф19

200
200

200

_

Ф22.2

280
280

280

Note: The additional refrigerant charging amount in Sheet 2 is recommended

value, not compulsory.

20

Sayfa 25

Pipe expanding method

Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand
the pipe according to the following steps:

A: Cut the pipe

E: Expand the port
●Expand the port with expander.

   the distance of indoor unit and 
   outdoor unit.
●Cut the required pipe with pipe cutter.
pipe

hard
mold

expander

pipe

pipe cutter

Note:
●"A" is different according to the
   diameter, please refer to the sheet 
   below:

leaning
uneven
burr

A(mm)

Outer diameter

B: Remove the burrs
●Remove the burrs with shaper and
   prevent the burrs from getting into 
   the pipe.

(mm)

Max
Min

Φ6 - 6.35(1/4")

1.3
0.7

Φ9.52(3/8")

1.6
1.0

pipe

Φ12-12.7(1/2")

1.8
1.0

shaper

Φ15.8-16(5/8")

2.4
2.2

downwards

F: Inspection
●Check the quality of expanding port.
    If there is any blemish, expand the 
    port again according to the steps 
    above.

C: Put on suitable insulating pipe
D: Put on the union nut
●Remove the union nut on the indoor
   connection pipe and outdoor valve; 
   install the union nut on the pipe.

smooth surface

improper expanding

union pipe

leaning
damaged

crack
uneven
thickness

surface

pipe

the length is equal

21

Sayfa 26

Specialist’s Manual

The following checks shall be applied to installations using flammable refrig-
erants:
– the charge size is in accordance with the room size within which the refrigerant
containing parts are installed;
– the ventilation machinery and outlets are operating adequately and are not
obstructed;
– if an indirect refrigerating circuit is being used, the secondary circuit shall be
checked for the presence of refrigerant;
– marking to the equipment continues to be visible and legible. Markings and signs
that are illegible shall be corrected;
– refrigeration pipe or components are installed in a position where they are unlikely
to be exposed to any substance which may corrode refrigerant containing compo-
nents, unless the components are constructed of materials which are inherently 
resistant to being corroded or are suitably protected against being so corroded.

Repair and maintenance to electrical components shall include initial safety 
checks and component inspection procedures. If a fault exists that could 
compromise safety, then no electrical supply shall be connected to the circuit 
until it is satisfactorily dealt with. If the fault cannot be corrected immediately 
but it is necessary to continue operation, an adequate temporary solution 
shall be used. This shall be reported to the owner of the equipment so all 
parties are advised.

Initial safety checks shall include:
– that capacitors are discharged: this shall be done in a safe manner to avoid possi-
bility of sparking;
– that no live electrical components and wiring are exposed while charging, recover-
ing or purging the system;
– that there is continuity of earth bonding.

Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and 
during work, to ensure the technician is aware of potentially toxic or flammable 
atmospheres. Ensure that the leak detection equipment being used is suitable for 
use with all applicable refrigerants, i.e. non-sparking, adequately sealed or intrinsi-
cally safe.

Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated 
parts, appropriate fire extinguishing equipment shall be available to hand. Have a 
dry powder or CO2 fire extinguisher adjacent to the charging area.

Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before breaking 
into the system or conducting any hot work. A degree of ventilation shall continue 
during the period that the work is carried out. The ventilation should safely disperse 
any released refrigerant and preferably expel it externally into the atmosphere.

Leak detection methods
Leak detection fluids are suitable for use with most refrigerants but the use of deter-
gents containing chlorine shall be avoided as the chlorine may react with the refrig-
erant and corrode the copper pipe-work.

22

Sayfa 27

Specialist’s Manual

Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the purpose 
and to the correct specification. At all times the manufacturer's maintenance and 
service guidelines shall be followed. If in doubt, consult the manufacturer's technical 
department for assistance.

Checks to electrical devices
– that capacitors are discharged: this shall be done in a safe manner to avoid possi-
bility of sparking; 
– that no live electrical components and wiring are exposed while charging, recover-
ing or  purging the system.

Repairs to sealed components
During repairs to sealed components, all electrical supplies shall be disconnected 
from the equipment being worked upon prior to any removal of sealed covers, etc. 
If it is absolutely necessary to have an electrical supply to equipment during servic-
ing, then a permanently operating form of leak detection shall be located at the most 
critical point to warn of a potentially hazardous situation.
Particular attention shall be paid to the following to ensure that by working on electri-
cal components, the casing is not altered in such a way that the level of protection 
is affected. This shall include damage to cables, excessive number of connections, 
terminals not made to original specification, damage to seals, incorrect fitting of 
glands, etc.
– Ensure that the apparatus is mounted securely.
– Ensure that seals or sealing materials have not degraded to the point that they no
longer serve the purpose of preventing the ingress of flammable atmospheres. 
Replacement parts shall be in accordance with the manufacturer’s specifications.

NOTE:The use of silicon sealant can inhibit the effectiveness of some types of leak 
detection equipment. Intrinsically safe components do not have to be isolated prior 
to working on them.

Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the circuit without 
ensuring that this will not exceed the permissible voltage and current permitted for 
the equipment in use.
Intrinsically safe components are the only types that can be worked on while live in 
the presence of a flammable atmosphere. The test apparatus shall be at the correct 
rating.
Replace components only with parts specified by the manufacturer. Other parts 
may result in the ignition of refrigerant in the atmosphere from a leak.

Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure, vibra-
tion, sharp edges or any other adverse environmental effects. The check shall also 
take into account the effects of aging or continual vibration from sources such as 
compressors or fans.

Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the searching 
for or detection of refrigerant leaks. A halide torch (or any other detector using a 
naked flame) shall not be used.

23

Sayfa 28

Specialist’s Manual

Decommissioning
Before carrying out this procedure, it is essential that the technician is completely 
familiar with the equipment and all its detail. It is recommended good practice that 
all refrigerants are recovered safely. Prior to the task being carried out, an oil and 
refrigerant sample shall be taken in case analysis is required prior to re-use of 
reclaimed refrigerant. It is essential that electrical power is available before the task 
is commenced.
a) Become familiar with the equipment and its operation.
b) Isolate system electrically.
c) Before attempting the procedure, ensure that:

– mechanical handling equipment is available, if required, for handling refrigerant
    cylinders;

– all personal protective equipment is available and being used correctly;
– the recovery process is supervised at all times by a competent person;
– recovery equipment and cylinders conform to the appropriate standards.
d) Pump down refrigerant system, if possible.
e) If a vacuum is not possible, make a manifold so that refrigerant can be removed
from various parts of the system.
f) Make sure that cylinder is situated on the scales before recovery takes place.
g) Start the recovery machine and operate in accordance with manufacturer's instruc-
tions.
h) Do not overfill cylinders. (No more than 80% volume liquid charge).
i) Do not exceed the maximum working pressure of the cylinder, even temporarily.
j) When the cylinders have been filled correctly and the process completed, make
sure that the cylinders and the equipment are removed from site promptly and all 
isolation valves on the equipment are closed off.
k) Recovered refrigerant shall not be charged into another refrigeration system
unless it has been cleaned and checked.

Labelling
Equipment shall be labelled stating that it has been de-commissioned and emptied 
of refrigerant. The label shall be dated and signed. For appliances containing flam-
mable refrigerants, ensure that there are labels on the equipment stating the equip-
ment contains flammable refrigerant.

Recovery
When removing refrigerant from a system, either for servicing or decommissioning, 
it is recommended good practice that all refrigerants are removed safely.
When transferring refrigerant into cylinders, ensure that only appropriate refrigerant 
recovery cylinders are employed. Ensure that the correct number of cylinders for 
holding the total system charge are available. All cylinders to be used are designat-
ed for the recovered refrigerant and labelled for that refrigerant (i.e. special cylin-
ders for the recovery of refrigerant). Cylinders shall be complete with pressure-re- 
lief valve and associated shut-off valves in good working order. Empty recovery 
cylinders are evacuated and, if possible, cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions 
concerning the equipment that is at hand and shall be suitable for the recovery of all 
appropriate refrigerants including, when applicable, flammable refrigerants. In addi-
tion, a set of calibrated weighing scales shall be available and in good working 
order. Hoses shall be complete with leak-free disconnect couplings and in good 
condition. Before using the recovery machine, check that it is in satisfactory working 

24

Sayfa 29

Specialist’s Manual

order, has been properly maintained and that any associated electrical components 
are sealed to prevent ignition in the event of a refrigerant release. Consult manufac-
turer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct 
recovery cylinder, and the relevant waste transfer note arranged. Do not mix refrig-
erants in recovery units and especially not in cylinders.
If compressors or compressor oils are to be removed, ensure that they have been 
evacuated to an acceptable level to make certain that flammable refrigerant does 
not remain within the lubricant. The evacuation process shall be carried out prior to 
re- turning the compressor to the suppliers. Only electric heating to the compressor 
body shall be employed to accelerate this process. When oil is drained from a 
system, it shall be carried out safely.

25

Sayfa 30

GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070

 
Tel: (+86-756) 8522218         
Fax: (+86-756) 8669426
E-mail: global@cn.gree.com
Web: www.gree.com

600005061344