eXPERT H070800.A - 2020/12 EN Instructions for installation and use - English Salt water chlorinator Translation of the original instructions in french More documents on: www.zodiac.com
• Before handling the appliance, it is vital that you read this installation and user manual, as well as the "Warranty" booklet delivered with the appliance. Failure to do so may result in material damage or serious or fatal injury and will void the warranty. • Keep and pass on these documents for reference during the appliance's service life. • The distribution or modification of this document in any way is prohibited, without prior authorisation from Zodiac®. • Zodiac® is constantly developing its products to improve their quality. The information contained herein may therefore be modified without notice. GENERAL WARNINGS • Failure to respect the warnings may cause serious damage to the pool equipment or cause serious injury, even death. • Only a person qualified in the technical fields concerned (electricity, hydraulics or refrigeration) is authorised to carry out maintenance or repair work on the appliance. The qualified technician working on the appliance must use/wear personal protective equipment (such as safety goggles and protective gloves, etc.) in order to reduce the risk of injury occurring when working on the appliance. • Before handling the appliance, check that it is switched off and isolated from mains power. • The appliance is intended to be used for pools for a specific purpose; it must not be used for any purpose other than that for which it was designed. • This appliance is not intended for use by individuals (including children) with impaired physical, sensorial or mental abilities, or persons lacking in knowledge and experience, unless they receive supervision or prior instructions on using the appliance from a person responsible for their safety. Children must be supervised to ensure that they do not play with the appliance. • This appliance can be used by children under 8 and adults with impaired physical, sensory or mental capabilities, or who lack experience and knowledge, if they are correctly supervised or have been instructed in how to use the appliance safely and understand the hazards involved. User cleaning and maintenance operations must not be carried out by children without supervision. • The appliance must be installed according to the manufacturer’s instructions and in compliance with local and national standards. The installer is responsible for installing the appliance and for compliance with national installation regulations. Under no circumstances may the manufacturer be held liable in the event of failure to comply with applicable local installation standards. • For any work other than the simple user maintenance described in this manual, the product should be referred to a qualified professional. • If the appliance suffers a malfunction, do not try to repair it yourself; instead contact a qualified technician. • Refer to the warranty conditions for details of the permitted water balance values for operating the appliance. • Deactivating, eliminating of by-passing any of the safety mechanisms integrated into the appliance, or the use of spare parts manufactured by unauthorised third-party manufacturers, shall automatically void the warranty. • Do not spray insecticide or any other chemical (inflammable or non-inflammable) in the direction of the appliance, as this may damage the body and cause a fire. 1 WARNINGS
WARNINGS ASSOCIATED WITH ELECTRICAL APPLIANCES • The power supply to the appliance must be protected by a dedicated 30 mA Residual Current Device (RCD), complying with the standards and regulations in force in the country in which it is installed. • Do not use any extension lead when connecting the appliance; connect the appliance directly to a suitable power supply. • Before carrying out any operations, check that: - The required input voltage indicated on the appliance information plate corresponds to the mains voltage; - The mains supply is compatible with the appliance's electricity needs and is correctly grounded. • In the event of abnormal operation or the release of odours from the appliance, turn it off immediately, unplug it from its power supply and contact a professional. • Before servicing or performing maintenance on the appliance, check that it is powered off and completely disconnected from the power supply. • Do not disconnect and reconnect the appliance to the power supply when in operation. • Do not perform maintenance or servicing operations on the appliance with wet hands or if the appliance is wet. • Before connecting the appliance to the power supply, check that the connection unit which the appliance will be connected is in good condition and shows no signs of damage or rust. • For any component or sub-assembly containing a battery: do not recharge or dismantle the battery, or throw it into a fire. Do not expose it to high temperatures or direct sunlight. • In stormy weather, disconnect the appliance from the power supply to prevent it from suffering lightning damage. • Do not immerse the appliance in water or mud. Recycling This symbol is required by the European directive DEEE 2012/19/EU (directive on waste electrical and electronic equipment) and means that your appliance must not be thrown into a normal bin. It will be selectively collected for the purpose of reuse, recycling or creating value. If it contains any substances that may be harmful to the environment, these will be eliminated or neutralised. Contact your retailer for recycling information. EN 2
❶Specifications 4 1.1 I Contents 4 1.2 I Technical specifications 5 1.3 I Dimensions 6 1.4 I Operating principle 6 ❷Installing the salt water chlorinator 7 2.1 I Installing the electrolytic cell 7 2.2 I Installing the flow switch 11 2.3 I Installing the sensors (pH & pH/ORP, depending on model) 12 2.4 I Installing the pH pump (pH & pH/ORP, depending on model) 13 2.5 I Installing the control box 15 2.6 I Connecting auxiliary devices 16 ❸Preparing the pool 19 3.1 I Balance the water 19 3.2 I Add salt 20 ❹Use 21 4.1 I User interface 21 4.2 I Routine use 23 4.3 I Settings that can be accessed in Configuration mode 24 4.4 I Calibrating the sensors (pH or pH/ORP models) 32 ❺Remote control using Fluidra Connect and NN app 34 5.1 I Wiring the chlorinator to Fluidra Connect power center 34 5.2 I Managing the chlorinator remotely with NN app 35 ❻Maintenance 36 6.1 I Sensor maintenance 36 6.2 I Inspecting and cleaning the electrodes 37 6.3 I Peristaltic pump maintenance 38 6.4 I Winterising 39 6.5 I Preparing the pool for new season 39 ❼Troubleshooting 40 7.1 I User alerts 40 7.2 I Effects of the stabilising agent on chlorine and ORP 41 3 CONTENTS
1❶ Specifications 1.1 I Contents Control box Electrolysis cell Wall-mounting bracket kit Flow switch with installation kit Sensor holder kit pH sensor (blue) + pH 7 and pH 4 buffer solutions PH pump kit: peristaltic pump, filter, injector, 2 metre suction (transparent 6x4 PVC) and injection (white 6x4 PE) pipes ORP sensor (yellow, with gold tip) + ORP buffer solution 470 mV : Included EN eXPERT eXPERT pH eXPERT pH/ORP 4
1.2 I Technical specifications eXPERT 7 12 21 30 40 Operating water temperature 5 - 40°C Volume of treated water (m³) (temperate climate, 8h/day filtration) 30 50 100 140 180 Nominal chlorine production 7 g/h 12 g/h 21 g/h 30 g/h 40 g/h Nominal output current 3.5 A 6 A 3.5 A 6 A 6.5 A Fuse (5x20 mm) 1 A T 2 A T 2 A T 3.15 A T 4 A T Recommended salt level (g/L) Power supply voltage 230V 50-60 Hz Electrical power 46 W 92 W 92 W 184 W 207 W Protection rating IPX5 Minimum flow rate required through the cell (m³/h) 3 3 5 6 8 Maximum allowable pressure in the cell 1 bar Number of electrode plates 3 5 7 11 13 Cell connection Ø63 mm (use Ø50mm PVC reducers for 50mm pipe) Sensor type Combined, glass body Ø12 mm pH measurement range 0.0 - 9.9 pH pH measurement accuracy 0.01 Sensor tolerance 0-40°C, water speed ≤ 2 m/s pH sensor calibration Semi-automatic in 2 points (pH 4 and pH 7) ORP measurement scale 0 - 999 mV ORP measurement accuracy 1 mV ORP sensor calibration Semi-automatic at 1 point (470 mV) Maximum counter pressure (injection point) 1.5 bar Peristaltic pump flow rate (pH) 1.5 L/h Length of box-cell cable 1.5 m Packaged net weight (kg) 9 11 13 15 17 5 5 5 4 4 4 Min-max: 4-10
1.3 I Dimensions 1.3.1. Cell 157 mm 332 mm 63 mm 1.3.2. Flow switch (and installation kit) 1.3.3. Control box 230 mm 120 mm 340 mm 1.4 I Operating principle The chlorinator is composed of an electrolytic cell (containing electrodes) and a control box. When the salt water from the swimming pool passes through the cell, the current generated by the electrodes creates an electrolytic reaction which transforms the chloride ions (from the salt in the swimming pool) into chlorine gas. Chlorine gas is a powerful disinfectant and is instantly dissolved in water. It then reverts back into salt under the action of UV radiation and also because of the need for disinfectant resulting from use of the pool (organic matter). The chlorinator therefore generates a cyclic reaction designed to produce chlorine. EN 6
2❷ Installing the salt water chlorinator 2.1 I Installing the electrolytic cell • The cell must always be the last element placed on the pool return pipe (see § “2.1.1. Installing the cell and the sensor holder (depending on model)”). • It is always recommended to install the cell on a by-pass. This assembly is mandatory if the flow is in excess of 18 m³/hour to avoid head loss. A flow regulation valve must be included. • When the cell is installed on a by-pass, fit a check valve downstream from the cell instead of a manual valve, to avoid any risk of incorrect configuration and poor circulation inside the cell. 2.1.1. Installing the cell and the sensor holder (depending on model) • The cell must be installed on the piping after the filtration system, after any measurement sensors, and after any heating system. • The cell's installation must allow easy access to the installed electrodes. • Two valves must be installed for isolating the cell from the rest of the installation, so that maintenance tasks can be performed without emptying the pool. Installing the chlorinator on a by-pass (recommended) Direct installation Control box Cell Flow switch Filter Electric terminal block Sensor holder + pH sensor and/or ORP sensor* pH pump* Container of pH-minus* Direct installation is only possible if the flow rate is going up. (*depending on model) • Respect the water flow direction indicated on the cell. • The circulation system must guarantee the minimum required flow (see§ “1.2 I Technical specifications”). • For Ø50 mm pipes, use glue-on PVC adapters of the corresponding diameter. • Connect the cell power cord following the wire colour codes (red, yellow, and orange connectors) and then refit the protective cap (see § “2.1.3. Connecting the cell to the control box”). 7 Outlet Inlet
2.1.2. Connecting the cell and the sensor holder • Do not glue sensor holder and cell directly together : use a PVC union coupler (not included) between sensor holder and cell. It is also possible to use a 6-to-8 cm PVC tube, Ø63 cm, with one beveled end (the one to glue to the cell inlet) and a PVC sleeve (to glue between the PVC tube and the sensor holder). For connecting the cell and the sensor holder : • Degrease the sensor holder, the cell inlet and the PVC union with PVC cleaner (not supplied). • Glue the sensor holder and the female union and fit them into each other as far as it will go. Remove any excess glue with a damp cloth. • Glue the cell inlet and the male union and fit them into each other as far as it will go. Remove any excess glue with a damp cloth. PVC union coupler Connecting the cell and the sensor holder 2.1.3. Connecting the cell to the control box • Open the cell protective cap by turning it anti-clockwise. • Identify the function of each wire (red, yellow, orange) in the power cable. EN PVC sleeve PVC pipe (fitted into the cell) Cable colour Function Red Electrolysis Red Electrolysis Yellow AUX / Conductivity Orange Temperature 8
• Identify the input points on the cell for each function, according to the appliance model: 9
• Attach the connectors by successively installing the terminals, washers, and nuts (see following table). • Carefully tighten the top nut by hand (risk of irreversible leakage). eXPERT 7 exPERT 12 eXPERT 21 eXPERT 30 exPERT 40 • Connect the cell to the control box, see§ “2.5 I Installing the control box”. EN 10
2.2 I Installing the flow switch • Failure to comply with these instructions could lead to the destruction of the cell. The manufacturer cannot be liable in this case. • The flow switch has a direction for installation (arrow indicated on it showing the flow direction for the water). Make sure that it is correctly placed on its fixture collar so that it stops the appliance's production when filtering is stopped. • The flow switch and its fixture collar (supplied) must be installed just in front of the cell and after a possible valve, in the flow section that supplies the cell. • Tighten the nuts by hand. Installation of the flow switch and the installation kit 11 G 3/4 F G 3/4 M G 1/2 M G 1/2 F
2.3 I Installing the sensors (pH & pH/ORP, depending on model) • Never wipe the sensor using a cloth or paper tissue, as this may damage it. • A badly-installed sensor may give false readings and cause inappropriate operation of the appliance. Neither the manufacturer nor the appliance shall be liable in this event. • Carefully unscrew the protection tube from the sensor ( ). Keep the protection tube for storing the sensor over winter. • Rinse the end of the sensor with tap water and shake off excess water ( ). • Loosen the nut fixed to the sensor holder ( ). • Install the pH sensor and/or the ORP sensor (supplied) in the sensor holder so that the sensor located at the end of the holder is always submerged in the water flowing through the piping( ). Ensure that the cable is not tangled. • To avoid damage, sensor end must be located in the center of the pipe, not further. • The sensor must always be installed vertically, or where necessary, at a maximum angle of 40°( ). • Once the sensor is installed it can be connected to the BNC socket on the control box, see § “2.5.2. Connecting the control box” ). • The sensor must then be calibrated, see § “4.4 I Calibrating the sensors (pH or pH/ORP models)”. ORP pH 40° EN 12
2.4 I Installing the pH pump (pH & pH/ORP, depending on model) • When handling chemical products, always use appropriate safety equipment (safety glasses, gloves, jacket and mask). • The pH pump is a peristaltic pump that rotates in the clockwise direction: it sucks up acid (pH-minus) to inject into the pool. 2.4.1. Installing the pH minus injection line • Cut a suitable length of white hose from the coil (supplied) to connect the ppH pump to the injection check valve. • Unscrew the connector cap and attach the hose to the connector at the outlet of the pH pump, see figure . Screw the cap in place. • Attach the other end of the hose to the injection check valve, see figure . 13 : Support tip : Ceramic weight : pH-minus container : Suction hose : pH pump : Inlet : Outlet : Injection hose : Injection check valve
2.4.2. Installing the pH minus suction line • Cut a suitable length of transparent hose from the coil (supplied) to connect the container of pH-minus to the pH pump. • Unscrew the connector cap and attach the hose to the connector at the inlet of the pH pump, see figure . Screw the cap in place. • Drill two holes into the cap of the pH minus container, see figure : - One hole suitable for the diameter of the hose ( )to aspirate the product. - One smaller hole to prevent the container from becoming deformed during aspiration of the product. • Pass the free end of the suction hose ( ) through the hole made in the cap ( ) and put the ceramic weight pro vided ( ) and the support tip on the hose, see figure . • Ensure that all connections are correct and watertight before operating the appliance. Do not place the pH-minus container directly beneath electrical equipment in the technical room to prevent risk of corrosion resulting from potential acidic vapours. EN pH-minus 14
2.5 I Installing the control box 2.5.1. Placement of the control box • The control box must be installed in a dry ventilated technical room protected against frost, with no pool maintenance products or similar products stored nearby. • The control box must be installed at a distance of at least 3.5 m from the outside edge of the pool. Always comply with the installation codes and/or laws applicable at the place of installation. • It must not be installed more than 1.6 metres from the cell (maximum cable length). • If the box is fixed to a post, a watertight panel must be fixed behind the control box (350x250 mm minimum): - Secure the mounting (provided) to the wall or to the watertight panel using screws or wall plugs (not provided) (figure ). - Clip the top of the control box into the mount (figure ). 15
2.5.2. Connecting the control box • Before beginning, disconnect all potential power supplies to the appliance. • Check that the cables used comply with the intended use and with the regulations in force. • Identify the connection point for each desired function at the bottom of the control box: pH ORP Electrolysis cell pH sensor (BNC connector)* ORP sensor (BNC connector)* ON/OFF switch Power supply (230V, 50-60Hz) controlled by filter pump relay (ON when pump is running) Fuse pH pump* Available space for Modbus cable if controlled with Fluidra Connect automation (NN app) Flow switch (*depending on model) 2.6 I Connecting auxiliary devices 2.6.1. Open the control box • Use a screwdriver to pry open the clips at the top of the front cover to dislodge it (see figure ). • Using a No. 3 Allen key, unscrew the 8 screws that secure the screen (see figure ). • Open the box and carefully position the screen (see figure ). EN 16
2.6.2. Detail of connections Contact closed (ON) Contact open (OFF) Activate the function Pool Cover Pool cover closed: reduced production (10% to 90%) Pool cover open : 100% production No external chlorination controller (ORP or PPM) or automatic ORP regulation (pH/ ORP model) Slave mode External chlorination controller connected (ORP or PPM) Flow switch* Flow switch detected No flow detected: Alarm See § “2.6.3. pH pump connection (for pH - PH/ORP models)” (*Flow switch comes already wired from the factory) pH pump 230 V supply when pH correction is needed (depending on model) 17 See§ “4.3.7. “Cover”: Connecting a pool cover” See § “4.3.12. “Cl EXT”: Slave mode” See § “4.3.5. “Flow”: Activating the flow switch”
2.6.3. pH pump connection (for pH - PH/ORP models) • Above 500mA, the pH pump connection must be protected by a circuit breaker with a suitable residual current protection device and controlled using a relay. Installation with provided pH pump Alternative solution if a bigger pump is used pH pump fuse: 5x20 T 500 mA/250V pH pump (included) pH pump >500 mA (not included) 230V relay EN 18
3❸ Preparing the pool 3.1 I Balance the water The water used must originate from a supply network compliant with Directive 98/83/EC on the quality of water intended for human consumption. In order for the water to be treated optimally, carry out measurements and adjust the values in accordance with the following recommendations: Seasonal analyses in "preparation for re-use" - Stabiliser (cyanuric acid) (<30 mg/L, ppm): the stabiliser protects chlorine from the destructive power of the sun's U.V. rays. Excessive stabiliser can block the disinfecting power of chlorine and turn the water turbid. - Metals (Cu, Fe, Mn) (± 0 mg/L, ppm): metals damage the metallic parts of the pool (corrosion phenomenon) or can cause permanent stains. Monthly analyses - TH (150 - 300 mg/L CaCO3 , ppm): the TH measures the water hardness (quantity of calcium carbonate), and this value can vary significantly depending on the geographical region concerned. - TA (80 -150 mg/L CaCO3 , ppm): the TA measures the water alkalinity, and this value allows the pH to be stabilised. It is important that the TA is adjusted before the pH. Weekly analyses - pH (7.0 - 7.4): the pH measures the acidity or alkalinity of the water. A pH in the range 7.0 to 7.4 helps to preserve the pool equipment and maintain effective disinfection. Taylor's balance method, as shown below, is used to adjust the pH value: TA pH TH Taylor's balance - Free chlorine (0.5 - 2 mg/L or ppm): this quantity of free chlorine makes the water both disinfected and disinfecting. Contact your retailer to determine the type of corrector product or automatic control appliance to be used to adjust the values. 19 : Mark the value of the TH after adjustment. : Mark the value of the TA after adjustment. : Draw a line between the TH value and the TA value to determine the pH value to be adjusted.
3.2 I Add salt Every appliance must be operated with a minimum recommended salt level, see § “1.2 I Technical specifications”. In order for the chlorinator appliance to operate properly, and to protect the equipment, we recommend using salt (sodium chloride) as per standard EN 16401. 3.2.1. Determining the quantity of salt to be used when installing the appliance Example: A. Appliance operating with 4 kg of salt per m³ of water (=4g/L or 4000 ppm). B. Appliance operating with 5 kg of salt per m³ of water (=5g/L or 5000 ppm). • 50m³ pool. The formula: A. 50m3 x 4 kg of salt/m³ = 200 kg of salt to be added to the water B. 50m3 x 5 kg of salt/m³ = 250 kg of salt to be added to the water 3.2.2. Routine analyses Check the salt level quarterly and readjust the quantity of salt present where necessary. ==> Method for adding salt to the water • Start the filter pump to cause the water in the pool to circulate. • If the appliance has already been installed, switch it off. • Move around the perimeter of the pool while pouring the required quantity of salt into the water to help disso lution. Add the salt in stages. It is easier to add salt to make up for an insufficient quantity that to dilute the salt present to make up for an excessive quantity. • Operate the filter pump for 24 hours. • After 24 hours have passed, check that the salinity level in the pool is correct, i.e. 4g/litre or 5g/litre (in the exam ples cited). • If the salt level is correct and the appliance has already been installed, switch it on then adjust the desired level of chlorine production, see § “4.2.1. Adjusting chlorine production”. Do not add salt directly in the skimmer(s). The appliance must only be switched on when the salt has completely dissolved in the pool. EN 20
4❹ Use 4.1 I User interface 4.1.1. User interface presentation BROWSING BUTTONS - Display the values for water temperature, salt concentration, pH & ORP values and setpoints (depending on model) and Boost mode management. - Browse and exit the Configuration menu - Calibrate - Configure values and confirm - Reduce production or a selected value - Access to the Configuration menu (hold 5 seconds with chlorination set to 0%) - Increase production or a selected value - Slide from left to right to unlock, see § “4.1.2. Unlocking the screen” INDICATORS Actual chlorine production Chlorine production setpoint Configuration mode activated "Pool cover" mode activated Automatic ORP regulation activated pH display (depending on model) : “intelligent” appears if mode is activated Slave mode activated Current cell polarity (direct or reverse) Salt concentration display 21 Buttons touch areas
Water temperature display ORP mV display (shows chlorination efficiency) Setpoint display Chlorination is off (setpoint = 0%) ALARMS Measured temperature too high or too low (non-blocking) Measured salt concentration too high or too low (non-blocking) Measured pH too high or too low (non-blocking) Measured ORP value too high or too low (non-blocking) Values too high Values too low pH pump stopped pH pump fuse blown Cell damaged or calcified Water flow problem 4.1.2. Unlocking the screen After a while whitout any use, chlorinator user interface goes into standby display to save energy (depending on the setting in the configuration menu). To wake it up, screen needs to be unlocked : • Slide your finger across the unlocking zone ( ) to the edge of the screen. EN 22
4.2 I Routine use 4.2.1. Adjusting chlorine production Chlorine production can be manually adjusted between 0 and 100% in intervals of 10%, by using or : the chlorine production setpoint indicator is adjusted (in the following example, for production at 70%). The setpoint value remains valid until next modified. 4.2.2. Displaying values and configuring setpoints The pH and ORP values are automatically displayed on the home screen. “Example with pH setpoint adjustment below (same logic for ORP setpoint).” To access all values and setpoints, press : - Press once to access the temperature value and setpoint, - Twice to access the salt concentration value and setpoint, - Three times to access the pH value and setpoint, - Four times to access the ORP value and setpoint. • The measured value appears at the top, the setpoint underneath (indicated by the icon). Example with pH setpoint adjustment (same logic for ORP setpoint) 23 Measured pH value Measured ORP value Measured value Setpoint
4.2.3. "Boost" mode In some cases, the pool may require a higher than normal chlorine level, for example during times of high use, bad weather or at the start of the pool season. "Boost" mode is used to quickly increase the chlorine level. It operates for 24 consecutive hours at a 100% production rate. When the filtration pump is connected to the appliance, the chlorination and filtration timers are temporarily ignored throughout the duration of the "Boost" mode. Once deactivated, the appliance and the filter pump resume the programmed operations. To activate the "Boost" mode: • Press five times : "BOOST OFF" is displayed on the screen. • Press to activate the mode: "OFF" flashes. • Press or : "24 h" flashes. • Press to confirm. • Press to exit. • When “Boost” mode is active, the blue circle representing actual chlorination will flash and spin. • “Boost” mode can be stopped at any time by applying the procedure above. 4.3 I Settings that can be accessed in Configuration mode 4.3.1. Accessing Configuration mode • From the home screen, press to reduce chlorine production to 0%. • Press for 5 seconds. The "Config" icon appears. Home screen EN Configuration mode activated (chlorinator type & power is shown on the screen) 24
• Press (see number of required presses in the following table) to access the desired function. Number of presses Screen display Function Additional information • Shows the appliance model • Displaying and resetting the number of operating hours of the cell or the pH pump 0 1 Shows the software version in use • See § «4.3.2. Appliance information»“ 2 reverse direct Polarity reversal cycles adjustment See § “4.3.4. “Reverse direct”: Reversal adjustment for cell cleaning” 3 flow Activation of the flow switch See § “4.3.5. “Flow”: Activating the flow switch” 4 flow cell Activation of the gas sensor See § “4.3.6. “Flow cell”: Activating the gas sensor” 5 cover Activation of "Pool cover" mode § “4.3.7. “Cover”: Connecting a pool cover” 6 pH intelligent Activation of "Intelligent pH" mode § “4.3.8. “Intelligent pH” mode” 7 i n i pH Activation of the “Initialisation” mode for pH regulation 8 pump Setting the pH pump over feed alarm triggering stop 9 auto Cl mV Activation of the automatic ORP regulation 10 Cl EXT Activation of Slave mode § “4.3.12. “Cl EXT”: Slave mode” 11 Setting the "Temperature" alarm triggering 12 Setting the "Salinity" alarm triggering 13 Activation of the user interface power saving mode 14 b i o Activation of "Bio pool" mode for natural pools Settings N/A N/A Calibrating the temperature See § “4.3.17. Calibrating the temperature” N/A N/A Calibrating the salt concentration See § “4.3.18. Calibrating the salt concentration” 25 • See § «4.3.2. Appliance information»“ • See § «4.3.3. Displaying and resetting the number of operating hours of the cell or the pH pump»“ § “4.3.9. “Ini pH”: Initialisation of pH regulation” § “4.3.10. “Pump stop”: pH pump stop over feed alarm (pH - PH/ORP models)” § “4.3.11. “Auto Cl mV”: Automatic ORP regulation (pH/ORP models)” § “4.3.10. “Pump stop”: pH pump stop over feed alarm (pH - PH/ORP models)” § “4.3.14. Setting the “Salinity” alarm triggering ” § “4.3.15. User interface energy saving mode” § “4.3.16. “Bio”: “Bio pool” mode for natural pools”
4.3.2. Appliance information Show the appliance model Show the current software version • Press for 5 seconds. • Press for 5 seconds then press . The soft The appliance model is displayed on the screen (platform version and g/h power). ware version is displayed on the screen. 4.3.3. Displaying and resetting the number of operating hours of the cell or the pH pump • Press for 5 seconds to see the “Appliance model” display. • Press once on to view the number of hours the cell has been in use (“Config Cell” is displayed) or press 3 times on to view the number of hours the pH pump has been in use (“Config” is displayed). • The “h” value corresponds to the number of hours the cell has been in use since the last reset. Press twice on to reset the value. • Press to switch to the “H” value: this corresponds to the total number of operating hours and cannot be reset. • Press to exit. 4.3.4. "Reverse direct": Reversal adjustment for cell cleaning The polarity reversal principle eliminates scaling that has deposited on the electrodes by reversing the electrical power at a specified time. • The hardness of the water varies depending on the geographical region concerned (water hardness = TH). • In order to protect the electrodes from scale build-up (which reduces the efficacy of the electrolysis reaction), the polarity reversal time can be adjusted. By default, the cycle is reversed every 2 hours. You may increase polarity reversal time to 3, 4 or 7h if water hardness is below 200 ppm (20°f). To set this duration: • In the Configuration/Reverse Direct mode, press to change the duration of polarity reversal. The displayed duration flashes. • Press or to choose between 2h, 3h, 4h or 7h (or “tSt” test mode). • Press to confirm the duration. EN 26
At the time of reversal, chlorination is stopped for a few minutes. No message is displayed on the screen. Normal operation resumes after reversal is complete. 4.3.5. "Flow": Activating the flow switch This mode is activated by default. To deactivate the use of the flow switch: • From the Configuration/Flow menu, press : "OFF" flashes. • Press or to switch to "ON". • Press to confirm. Deactivating the use of the flow switch is not recommended as it is a safety feature. 4.3.6. “Flow cell”: Activating the gas sensor This mode is activated by default. To deactivate the use of the gas sensor: • From the Configuration/Flow cell menu, press : “ON” flashes. • Press or to switch to “OFF”. • Press to confirm. Deactivating the use of the gas sensor is not recommended as it is a safety feature. 27
4.3.7. "Cover": Connecting a pool cover
If the pool is equipped with a compatible electric cover, it can be connected to the appliance in order to automatically
reduce chlorination when it is closed: this is the "Cover " mode. It is then automatically activated when the pool cover
is closed, and chlorination resumes at the level determined by the programming on opening the compatible electric
pool cover.
Check that the cover is compatible and is connected to the appliance on the low-voltage circuit, see § “2.6 I
Connecting auxiliary devices”.
This mode is deactivated by default. To activate it and configure the production:
• From the Configuration/Cover mode, press
then
to activate or configure the desired percentage of pro
duction (configurable between 10% and 90%).
• Press
to confirm.
Recommendations for use:
• Adjust the production percentage to between 10% and 30%.
• You may let ORP regulation manage chlorination instead of pool cover mode if water stay warm when
pool cover is closed.
4.3.8. "Intelligent pH" mode
The "Intelligent pH" mode is used to adjust the pH more precisely: it reduces production as the setpoint is
approached, thus reducing wider fluctuations in pH levels.
This mode is activated by default. To deactivate it:
• From the Configuration/Intelligent pH mode, press
: "ON" flashes.
• Press
to deactivate it ("OFF").
• Press
to confirm.
4.3.9. "Ini pH": Initialisation of pH regulation
This mode allows the pH measurement to stabilise over a certain time at each start-up, before starting to dose (if
necessary). The initialisation time can be set to 0, 1, 2 or 4 minutes.
This mode is deactivated by default. To activate it:
• From the Configuration/Ini pH mode, press
: "OFF" flashes.
• Press
to activate ("ON") and to configure the initialisation time.
• Press
to confirm.
• It is advised to enable this feature and set it to “1 min” to prevent unwanted pH corrective product
injection upon each filter pump startup.
EN
284.3.10. “Pump stop”: pH pump stop over feed alarm (pH - PH/ORP models)
The pH pump stops rotating if the pH setpoint has not been reached after a given time, resulting in the display of an
alarm. By default, this programmed safety time is 60 minutes. To adjust it (minimum value: 1 min - maximum value:
120 min):
• From the Configuration/Pump stop mode, press
: “OFF” flashes
• Press
to switch to “ON”. The injection time flashes.
• Press
or
to adjust this value.
• Press
to confirm.
4.3.11. "Auto Cl mV": Automatic ORP regulation (pH/ORP models)
This mode is activated by default on pH/ORP models only. Production stops when the setpoint is passed. To deactivate
the automatic mode:
• From the Configuration/Auto Cl mV mode, press
: "ON" flashes.
• Press
to activate it ("OFF").
• Press
to confirm.
4.3.12. "Cl EXT": Slave mode
• Ensure that these appliances are properly connected to the power supply in accordance with
the regulations in force and are protected by a circuit breaker (filtration unit).
Slave mode transfers control over the chlorination function to an external controller (ORP or ppm control). Once the
external controller is correctly connected to the connection point (see § “2.6.2. Detail of connections”), activate the
Slave mode:
• From the Configuration/Cl EXT auto mode, press
: "OFF" flashes.
• Press
to activate it ("ON").
• Press
to confirm.
•
294.3.13. Setting the “Temperature” alarm triggering When the measured temperature is outside the configured range, an alarm is displayed. The recorded default range is 5°C - 40°C. To adjust it: • From the Configuration/ mode, press : the minimum value (indicated by “LO”) flashes. • Press or to adjust this value (select 0 to deactivate the alarm). • Press to confirm: the maximum value (indicated by “HI”) flashes. • Press or to adjust this value. • Press to confirm. 4.3.14. Setting the “Salinity” alarm triggering When the water’s measured salt concentration is outside the configured range, an alarm is displayed. The recorded default range is 2.5 g/L - 8 g/L). To adjust it: • From the Configuration/ mode, press : the minimum value (indicated by “LO”) flashes. • Press or to adjust this value (select 0.5 to deactivate the alarm). • Press to confirm: the maximum value (indicated by “HI”) flashes. • Press or to adjust this value. • Press to confirm. EN 30
4.3.15. User interface energy saving mode
By default, the screen power saving mode is activated and an appliance which is unused goes into standby: an
animated production indicator is displayed and the measured values are not visible. To deactivate this mode:
• From the Configuration/D15 ECO mode, press
: “OFF” flashes.
• Press
to switch to “ON”.
• Press
to confirm.
4.3.16. "Bio": "Bio pool" mode for natural pools
The "Bio" mode is used to modify the pH and ORP setpoints and the related high and low alarms (see the values in the
table below) so they are best suited to natural pools.
mode
Threshold
Alarm
« Bio pool »
pH
OFF (default)
7.0
7.8
> 8.5
< 6.5
ON
6.5
8.5
> 9.0
< 6.0
ORP (mV)
OFF (default)
600
850
> 855
< 600
ON
300
850
> 855
< 300
By default, this mode is disabled; to activate it:
• From the Configuration/bio mode, press
: "OFF" flashes.
• Press
to activate it ("ON").
• Press
to confirm.
4.3.17. Calibrating the temperature
• From the home screen, press
to access the temperature values (*).
• Press
to enter the Calibration mode. The screen displays
(“Standard”).
• Press
to select this mode. The value flashes.
• Press
or
to change the value.
• Press
to confirm.
Press
at this step to switch between a temperature display in degrees Celsius (°C) and degrees Fahrenheit
(°F).
4.3.18. Calibrating the salt concentration
• From the home screen, press twice on
to access the salinity values.
• Press
to enter Calibration mode. The screen displays
(“Standard”).
• Press
to select this mode. The value flashes.
• Press
or
to change the value.
• Press
to confirm.
31
High (HI)
Low (LO)4.4 I Calibrating the sensors (pH or pH/ORP models)
4.4.1. Choosing the calibration mode
• The pH sensor and the ORP sensor can be calibrated in "Standard" mode
• The pH sensor can also be calibrated in "Fast" mode
Standard mode (pH & ORP)
Fast mode "Fast" (pH)
Restart
Calibrate the sensor by
Calibrate without removing
the sensor
Restart calibration
removing it
4.4.2. Calibrating the pH sensor in "Standard" mode
In “Standard” mode, the pH sensor is calibrated in 2 point calibration (pH 4 and pH 7) ; 2 point calibration is recommended
for more accurate measurement.
• Switch off the pool's pump and close the necessary valves in order to isolate the cell and the sensors.
• From the home screen, press
3 times to access the pH values.
• Press
to enter Calibration mode. The screen displays
("Standard").
• Press
to select this mode. The screen displays
.
• Remove the sensor.
• Rinse the tip of the sensor with tap water.
• Shake it to remove any residual water. Do not touch the glass bulb at the end of the pH sensor.
• Place the tip of the pH sensor in the pH 7 solution.
• Wait 15 seconds.
• Press
to continue. The screen displays
.
• Rinse the tip of the sensor with tap water.
• Shake it to remove any residual water. Do not touch the glass bulb at the end of the pH sensor.
• Place the tip of the pH sensor in the pH 4 solution.
• Wait 15 seconds.
• Replace the sensor back in its holder.
• Press
. Calibration is complete.
• If necessary, adjust the setpoint (see § “4.4.4. Configuring the pH setpoint”) or press
to return to the home
screen.
4.4.3. Calibrating the pH sensor in "Fast" mode
In “Fast” mode, the pH sensor is calibrated in 1 point calibration ; 1 point calibration is possible if the pH 7 and pH 4
solutions provided are not available.
• From the home screen, press
3 times to access the pH values.
• Press
to enter Calibration mode. The screen displays
("Standard").
• Press
. The screen displays
("Fast" calibration mode).
• Press
. The second displayed value flashes.
• Place a pH meter in the pool's water then modify this second value with
or
so that it matches the value
displayed by the pH meter.
• Press
to confirm. The current sensor measurement has been replaced.
• If necessary, adjust the setpoint (see § “4.4.4. Configuring the pH setpoint”) or press
to return to the home
screen.
EN
324.4.4. Configuring the pH setpoint
The pH setpoint configuration determines the time when acid is added to the system to reduce the water's pH. The
default value of the pH setpoint is 7.2.
To determine the value of the setpoint to be configured, refer to Taylor's balance, see § “3.1 I Balance the water”.
• Press
three times to display the pH setpoint.
• Press
The setpoint value flashes.
• Press
and
to select the desired value. These values are increments of 0.1.
• Press
to confirm.
• Press
to exit.
4.4.5. Calibrating the ORP sensor
• Switch off the pool's pump and close the necessary valves in order to isolate the cell and the sensors.
• From the home screen, press
4 times to access the ORP values.
• Press
to enter Calibration mode. The screen displays
("Standard").
• Press
to select this mode. The screen displays
• Remove the sensor.
• Rinse the tip of the sensor with tap water.
• Shake it to remove any residual water. Do not touch the gold tip at the end of the ORP sensor.
• Place the tip of the ORP sensor in the ORP 470 mV solution.
• Wait 15 seconds.
• Rinse the tip of the sensor with tap water.
• Replace the sensor back in its holder.
• Press
. Calibration is complete.
• If necessary, adjust the setpoint (see § “4.4.6. Configuring the ORP setpoint”) or press
to return to the home
screen.
4.4.6. Configuring the ORP setpoint
The ORP setpoint configuration determines the time at which chlorine is produced by the appliance. The level of
free chlorine must be controlled at regular intervals after initial installation. The default value of the ORP setpoint is
700 mV.
The value of the setpoint depends on the pool's environment, its affluence, and the amount of stabiliser present in the
pool water.
• From the home screen, press
4 times to access the ORP values.
• Press
. The setpoint value flashes.
• Press
and
to select the desired value (recommended between 650 mV and 750 mV). These values are
increments of 1.
• Press
to confirm.
• Press
to exit.
33
Current sensor measurement
Setpoint5❺ Remote control using Fluidra Connect and NN app 5.1 I Wiring the chlorinator to Fluidra Connect power center The chlorinator is a connectable device: information on the status of the swimming pool can be accessed at any moment (to check the dashboard, change a setting, etc.) from a smartphone or tablet via the Fluidra Connect NN app. For this, the chlorinator must first be connected to a Connect & Go automation power center, following the connection method shown below. • It’s strongly advised to use a specific RS485 cable to wire the chlorinator to the Connect & Go power center. If not available, an Ethernet cable can be used (RJ45 connectors cannot be used). • The Fluidra Connect NN app also provides the possibility to locate professionals who can remotely check the swimming pool, access the measurement history, and display errors through a Fluidra Connect service platform. Connect & Go automation unit Chlorinator Connections: A D+ BLUE GND COM BROWN B D- WHITE EN 34
5.2 I Managing the chlorinator remotely with NN app Before you install the app, you must: • Use a Wi-Fi-enabled smartphone or tablet, • Use a Wi-Fi network with a reasonably strong signal when connecting to the chlorinator. • Have your home Wi-Fi network password at the ready. • Download the Fluidra Connect NN app from the App Store or Google Play Store. • Connect to your account or register to create an account (first-time use). • Access your pool settings or adjust setpoints remotely. Access the pool settings from the "Dashboard" tab 35 Adjust the setpoints from the "Devices" tab
6❻ Maintenance 6.1 I Sensor maintenance The sensors must be cleaned every 2 months. • Stop the filter pump. • Close all valves. • Remove the sensor and the sensor holder. • Rinse the sensor in tap water for 1 minute. • Shake it to remove any residual water. To prevent damage to the active part, do not rub and do not dry with a cloth. • Brush the junctions and the metal part (Gold) for the ORP sensor using a toothbrush for 1 minute. • Prepare a solution of diluted hydrochloric acid by pouring 1 mL (10 drops) of commercially-available hydrochloric acid (HCl 37 %) into 50 mL of tap water (1/2 glass of water). • Hydrochloric acid is a hazardous chemical that may cause burns, lesions and irritations. Handle with care and use protective equipment (gloves, safety glasses, overalls). Refer to the product's MSDS for more information. • Always pour the acid into the water. • Once cleaning is complete, dispose of the solution according to the standard in force in the country of use. • Wash the sensor in the diluted hydrochloric acid solution for 2 minutes. • Rinse the sensor in clean water under the tap for 1 minute. • Shake it to remove any residual water. • Then calibrate the sensor, see § “4.4 I Calibrating the sensors (pH or pH/ORP models)”. • Replace the sensor holder and the sensor. EN 36
6.2 I Inspecting and cleaning the electrodes The appliance is equipped with a smart polarity inversion system designed to prevent the electrode plates from scaling. The polarity reversal time can be modified, see § “4.3.4. “Reverse direct”: Reversal adjustment for cell cleaning”. However cleaning may be required in regions where the water is very hard. • Turn off the appliance and the filtration system, close the isolation valves, remove the protection cover and discon nect the cell power cable. • Unscrew the tightening ring and remove the cell. The ring is crenelated thus allowing a lever to be used in the event of it jamming (see figure ). • Submerge the part containing the electrode plates in a suitable recipient containing a cleaning solution (see figure ). • Leave the cleaning solution to dissolve the scale deposit for about 10 minutes. Dispose of the cleaning solution at an approved waste recycling site. Never pour into the rainwater drainage system or into the sewers. • Rinse the electrode using clean water and put it back on the cell fixture collar (there is an alignment foolproofer). • Refit the tightening ring, reconnect the cell cable and refit the protective cover. • Re-open the isolation valves and restart the filtering system and appliance. If you are not using a commercially-available cleaning solution, you can make your own by carefully mixing 1 part hydrochloric acid with 10 parts water. (Caution: always pour the acid into the water and not the opposite and wear suitable protective equipment). 37
6.3 I Peristaltic pump maintenance • To prevent the pump from operating when empty, check the level of the pH-Minus (acid) container every 2 to 12 months, depending on your installation (see table below). HYDROCHLORIC ACID HYDROCHLORIC ACID Very corrosive atmosphere (installation not recommended) Corrosive atmosphere (acceptable installation) - Check every 2 to 3 months - Check every 3 to 6 months • To check the correct operation of the pH pump: - Ensure the tube is in good condition ( ) and the connections are correctly sealed, - Check that the tablet holder rotates correctly ( ). SULFURIC ACID EN Non-corrosive atmosphere (recommended installation) - Check every 6 to 12 months 38
6.4 I Winterising The appliance is fitted with a protection system limiting chlorine production in poor operating conditions such as cold water (winter) or low salt. • Active winterising = filtering operational in winter: below 10°C it is preferable to switch off the appliance. Above this temperature you can leave it running. • Passive winterising = lower water level and drained piping: switch off the appliance and leave the cell dry in place with any isolation valves open. • Winterising the sensors = Keep the plastic sensor tube (which contains a storage solution) for re-use when win terising. The sensors must always be stored wet (never dry). They must be stored in the tube filled with a storage solution of 3 mol/L KCl or at least in tap water. 6.5 I Preparing the pool for new season Required actions: • Adjust the water level (too much or too little). • Check the water parameters: TA/TH/pH/Salinity/Chlorine/Stabiliser/Copper/Metals, and adjust the parameters to obtain a balanced, healthy pool, see § “3.1 I Balance the water”. • Check the condition of the equipment (pump, filter, chlorinator, electrolytic cell). • Inspect the sensors, then clean and recalibrate. • As soon as the salt level reaches the required level (4,000 ppm or 5,000 ppm) and has completely dissolved in the water, restart the salt water chlorinator. 39
7❼ Troubleshooting • Before you contact the retailer, carry out these few simple checks using the following table if a problem occurs. • If the problem is not resolved, contact your retailer. • : Actions to be performed by a qualified technician only 7.1 I User alerts Message Possible cause Solution • The appliance automatically exits Calibration mode after two minutes without any action by the user. This message then appears briefly on the screen. • Information only, no issue. • If needed, restart the calibration process from the beginning, see § “4.4 I Calibrating the sensors (pH or pH/ORP models)”. • The value detected during calibration differs greatly from the expected value, making calibration impossible. • Visually check the condition of the sensor and rinse it. • Repeat the measurement in a buffer solution, wait 15 seconds, then recalibrate if the measurement is incorrect. • Clean the sensor or replace if necessary. • The value detected during calibration is unstable, making calibration impossible. • The pH pump fuse is faulty. • Check the pH pump to ensure it’s not damaged. • Replace the pH pump fuse (inside the chlorinator power pack). • pH setpoint has not been reached within allocated time frame. • Check pH value and calibrate the pH sensor if needed. • Check pH pump tubing and container to ensure pH minus can be injected. • Adjust the alarm trigger time, see § “4.3.10. “Pump stop”: pH pump stop over feed alarm (pH - PH/ORP models)”. • Reset the alarm: press • The pH pump has stopped. • Steady red: The temperature setpoint is lower or higher than the measured value (not blocking) • Flashing: Water conductivity problem: the appliance is not reaching 100% production • Check the alarm triggering range (see § “4.3 I Settings that can be accessed in Configuration mode”). • Check the electrode wiring: ensure compliance with the numerical codes and the colours (see § “2.1.3. Connecting the cell to the control box”) • Check the water temperature. • Check the condition of the cell plates. • Measure the salt concentration in the pool water using a salt tester or a test strip, then add salt to the pool to keep the level at 4 or 5 g/L. Consult your retailer if necessary. • Steady red: The salt concentration setpoint is lower or higher than the measured value (not blocking) • Flashing: Water conductivity problem: the appliance is not reaching 100% production • Steady red: The pH setpoint is lower or higher than the measured value (not blocking) • Steady red: The ORP setpoint is lower or higher than the measured value (not blocking) • Check the cell connections. • Replace the cell if necessary: consult your retailer • Short-circuit in the cell or cell not properly connected. • Worn electrode: the cell is worn out EN 40
• Water flow problem: - Filter pump failure, - Filter and/or the skimmer(s) are dirty, - Disconnection or failure of the flow switch. • The appliance has stopped producing. • The appliance is in standby. The blue indicator spins The values are not displayed. Tip: if you require assistance, inform your retailer about the appliance's condition to save time 7.2 I Effects of the stabilising agent on chlorine and ORP A pool ideally has a stabiliser level of 30 ppm and a pH of 7.4. 1 ppm of free chlorine = 700 mV • The user can therefore adjust the chlorination requirements to 700 mV to maintain a level of 1 ppm in the pool. • If the level of stabiliser rises to 90 ppm, the ORP value will be incorrect and 1 ppm of free chlorine will correspond to 500 mV. • If the user keeps the setpoint at 700 mV, a chlorine concentration of 5 ppm will eventually be obtained. Variations in the ORP measurement depending on the stabiliser concentration (pH 7.4, 25°C)*. CHLORINE LEVEL (PPM) ORP MEASUREMENT (MV) * Theoretical values for information purposes only. Real values may vary slightly depending on the type of water in the pool. 41 • Check the pump, the filter, the skimmer(s) and the by-pass valve(s). Clean them if necessary. • Check the wire connections (flow switch). • Check that the flow switch is working correctly: replace it if necessary: contact the retailer) • Increase production. Clearly distinguish the appliance's actual production and the setpoint. • Have the control box checked by a qualified technician. • Unlock the screen (see § “4.1.2. Unlocking the screen”. • Deactivate the energy saving mode so that the values can be read when the device is in standby, see § “4.3.15. User interface energy saving mode”. Stabiliser level of 90 ppm Stabiliser level of 30 ppm Setpoint
Votre revendeur Your retailer Modèle appareil Appliance model Numéro de série Serial number Pour plus d’informations, enregistrement produit et support client : For more information, product registration and customer support: www.zodiac.com ©2020 Zodiac Pool Systems LLC. All rights reserved. ZODIAC® is a registered trademark of Zodiac International, S.A.S.U., used under license. All other trademarks are the property of their respective owners. ZPCE - ZA La Balme - 31450 Belberaud - S.A.S.U. au capital de 1 267 140 € / SIRET 395 068 679 00046 / RCS TOULOUSE