SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS APPLICATIONS Self priming centrifugal pump with excellent suction capacity even in the presence of air bubbles. Suitable for pumping water with low levels of sandy impurities. Especially used in domestic water supply installations. Suitable for small farms and gardening, small scale industrial services and where self priming is necessary. CONSTRUCTIONAL FEATURES OF THE PUMP Pump body in technocpolymer and motor support in die cast aluminium. Impeller, diffuser, venturi tube and sand guard in technopolymer Stainless steel wear ring. Carbon/ceramic mechanical seal. CONSTRUCTIONAL FEATURES OF THE MOTOR Asynchronous type, closed, with external air cooling. Rotor mounted on oversized greased-for-life ball bearings, to guarantee low noise and long life. Incorporated thermo-amperometric protection and permanently inserted capacitor in the single phase version. It is recommended to use overload protection for three phase motor protection, in compliance with current legislation. Manufactured pursuant to CEI 2-3 and CEI 61-69 (EN 60335-2-41). DAB PUMPS reserve the right to make modifications without prior notice 20 JETCOM SELF-PRIMING CENTRIFUGAL ELECTRIC PUMPS TECHNICAL DATA Operating range: from 0.6 to 5.4 m3/h with head up to 54 metres. Liquid quality requirements: clean, free from solid or abrasive contaminants, non-viscous, non-aggressive, uncrystallised and chemically neutral. Liquid temperature range: from 0°C to +35°C for domestic use (EN 60335-2-41). Maximum ambient temperature: +40°C Maximum operating pressure: 6 bar (600 kPa) Maximum suction depth: 8 metres. Installation: fixed in a horizontal position. Special executions on request: alternative voltages and/or frequencies. Motor protection rating: IP 44 Terminal block protection rating: IP 55 Insulation class: F Standard input voltage: single phase 220/240 V / 50 Hz three phase 230/400 V - 50 Hz
JETCOM SELF-PRIMING CENTRIFUGAL ELECTRIC PUMPS MATERIALS N° PARTS * MATERIALS 1 4 28 7 1 PUMP BODY TECHNOPOLYMER A 4 IMPELLER TECHNOPOLYMER A 7 SHAFT WITH ROTOR AISI 416 STAINLESS STEEL X12 CrS13 - UNI 6900/71 16 MECHANICAL SEAL CARBON/CERAMIC 28 OR GASKET NBR RUBBER 3 16 160 36 SEAL HOLDER COVER AISI 304 STAINLESS STEEL X5 CRNi 1810 - UNI 6900/71 160 VENTURI DIFFUSER NOZZEL GROUP TECHNOPOLYMER A * In contact with liquid SELF PRIMING CAPACITY H (ft) 10 10 30 9 9 8 8 25 7 7 20 Hs (m) Suction head 6 Hs (m) Suction head 6 5 5 15 4 4 10 3 3 2 2 G 1 DN 25 5 1 1 0 10 20 30 40 50 60 70 80 90 100 0 0 0 10 20 30 40 50 60 70 80 90 100 0 0 t (sec) Self priming timing t (sec) Self priming timing DAB PUMPS reserve the right to make modifications without prior notice SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS H (ft) 30 25 20 15 10 5 21
JETCOM SELF-PRIMING CENTRIFUGAL ELECTRIC PUMPS SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS PERFORMANCE RANGE The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906. GRAPHIC SELECTION TABLE 5 10 15 30 50 5 10 15 30 50 H m H kPa JET JETINOX JETCOM GARDENJET GARDEN INOX GARDEN COM AQUAJET AQUAJET INOX 700 70 600 62 - 82 - 102 - 112 JET JETINOX JETCOM 60 GARDENJET GARDEN INOX GARDEN COM AQUAJET AQUAJET INOX 500 50 92 - 132 400 40 300 30 JET 151 JET 251 JET 200 JET 300 200 20 10 100 1 2 3 4 5 6 7 8 9 10 15 2 1 3 Q l/s 20 30 50 100 150 200 JETCOM SELECTION TABLE Q=m3/h 0 0.6 1.2 1.8 2.4 3.0 3.6 4.2 4.8 MODEL Q=l/min 0 10 20 30 40 50 60 70 80 JETCOM 62 M 42 35 29.2 25.6 22.9 13 JETCOM 82 M 47 40 34 30 26.2 23.5 20 JETCOM 102 M 53.8 47 41 36.3 32.4 28.8 25.8 H (m) JETCOM 102 T 53.8 47 41 36.3 32.4 28.8 25.8 JETCOM 92 M 36.2 33.5 31 28.4 26 24 21.8 19.6 17.5 JETCOM 132 M 48.3 45.6 42.8 40 37.6 35 32.5 30 27.2 JETCOM 132 T 48.3 45.6 42.8 40 37.6 35 32.5 30 27.2 DAB PUMPS reserve the right to make modifications without prior notice 22 Q US gpm Q IMP gpm H ft 200 150 100 50 Q m3/h Q l/min
JETCOM 62-SELF-PRIMING CENTRIFUGAL ELECTRIC PUMPS FOR DOMESTIC WATER SUPPLY Liquid temperature range pumped: from 0 °C to +35 °C - Maximum ambient temperature: +40°C A Q US gpm 0 2 4 6 8 10 12 C 0 2 4 6 8 10 Q IMP gpm SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS P kPa H m H ft DNM 400 40 120 DNA 100 300 30 JETCOM 62 80 H H2 200 20 Hs 9 60 8 7 6 5 4 2 40 F 100 10 3 E I 20 G 0 0 Q m3/h 0 0,5 1 1,5 2 2,5 3 0 B Q l/s 0 0,2 0,4 0,6 0,8 Q l/min 0 10 20 30 40 50 The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906. ELECTRICAL DATA MODEL CAPACITOR kW HP μF Vc P2 NOMINAL In POWER SUPPLY 50 Hz P1 MAX kW A JETCOM 62 M 1x220-240 V ~ 0.72 0.44 0.6 3.12 12.5 450 PACK DIMENSIONS VOLUME GROSS WEIGHT MODEL A B C E F G H H1 H2 I Ø L DNA GAS DNM GAS (mc) Kg L/A L/B H JETCOM 62 406 170 122 208 14 111 198 – 144 9 – 1” 1” 470 240 240 0.027 7.5 JETCOM 82-SELF-PRIMING CENTRIFUGAL ELECTRIC PUMPS FOR DOMESTIC WATER SUPPLY Liquid temperature range pumped: from 0 °C to +35 °C - Maximum ambient temperature: +40°C A Q US gpm 0 2 4 6 8 10 12 14 16 C Q IMP gpm 0 2 4 6 8 10 12 14 P kPa H m H ft DNM 50 DNA 160 400 40 120 JETCOM 82 300 100 30 H H2 80 Hs 9 200 20 60 8 7 6 F 40 5 4 3 2 E 100 10 I 20 G 0 0 Q m3/h 0 0,5 1 1,5 2 2,5 3 3,5 4 0 B Q l/s 0 0,2 0,4 0,6 0,8 1 Q l/min 0 10 20 30 40 50 60 The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906. ELECTRICAL DATA MODEL CAPACITOR kW HP μF Vc P2 NOMINAL In POWER SUPPLY 50 Hz P1 MAX kW A JETCOM 82 M 1x220-240 V ~ 0.85 0.6 0.8 3.8 12.5 450 GROSS WEIGHT PACK DIMENSIONS VOLUME MODEL A B C E F G H H1 H2 I Ø L DNA GAS DNM GAS (mc) Kg L/A L/B H JETCOM 82 406 170 122 208 14 111 198 – 144 9 – 1” 1” 470 240 240 0.027 7.7 DAB PUMPS reserve the right to make modifications without prior notice 23
JETCOM 102 - SELF-PRIMING CENTRIFUGAL ELECTRIC PUMPS FOR DOMESTIC WATER SUPPLY Liquid temperature range pumped: from 0 °C to +35 °C - Maximum ambient temperature: +40°C A Q US gpm 0 2 4 6 8 10 12 14 16 C 0 2 4 6 8 10 12 14 Q IMP gpm SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS P kPa H m H ft DNM 50 DNA 160 400 40 JETCOM 102 120 100 300 30 H Hs 9 H2 80 8 7 200 20 6 5 3 60 4 2 40 F 100 10 E I 20 G 0 0 Q m3/h 0 0,5 1 1,5 2 2,5 3 3,5 4 0 B Q l/s 0 0,2 0,4 0,6 0,8 1 Q l/min 0 10 20 30 40 50 60 The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906. ELECTRICAL DATA MODEL CAPACITOR kW HP μF Vc P2 NOMINAL In POWER SUPPLY 50 Hz P1 MAX kW A JETCOM 102 M 1x220-240 V ~ 1.13 0.75 1 5.1 16 450 JETCOM 102 T 3x230-400 V ~ 1.04 0.75 1 3.3-1.9 – – PACK DIMENSIONS VOLUME GROSS WEIGHT MODEL A B C E F G H H1 H2 I Ø L DNA GAS DNM GAS (mc) Kg L/A L/B H JETCOM 102 425 170 122 208 14 111 203 – 144 9 – 1” 1” 470 240 240 0.027 9.5 JETCOM 92-SELF-PRIMING CENTRIFUGAL ELECTRIC PUMPS FOR DOMESTIC WATER SUPPLY Liquid temperature range pumped: from 0 °C to +35 °C - Maximum ambient temperature: +40°C A Q IMP gpm Q US gpm 0 0 2 4 6 8 10 12 14 16 18 20 22 24 2 4 6 8 10 12 14 16 18 20 C P kPa H m H ft DNM 140 DNA 40 400 120 100 30 300 JETCOM 92 H 80 H2 20 200 60 Hs 9 8 40 7 5 4 3 F 10 100 6 E I 20 2 G Q m3/h 0 1 2 3 4 5 0 0 0 B Q l/s Q l/min 0 0,2 0,4 0,6 0,8 1 1,2 1,4 0 10 20 30 40 50 60 70 80 90 The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906. ELECTRICAL DATA MODEL CAPACITOR kW HP μF Vc P2 NOMINAL In POWER SUPPLY 50 Hz P1 MAX kW A JETCOM 92 M 1x220-240 V ~ 0.94 0.75 1 4.2 14 450 GROSS WEIGHT PACK DIMENSIONS VOLUME MODEL A B C E F G H H1 H2 I Ø L DNA GAS DNM GAS (mc) Kg L/A L/B H JETCOM 92 425 170 122 208 14 111 203 – 144 9 – 1” 1” 470 240 240 0.027 8.7 DAB PUMPS reserve the right to make modifications without prior notice 24
JETCOM 132 - SELF-PRIMING CENTRIFUGAL ELECTRIC PUMPS FOR DOMESTIC WATER SUPPLY Liquid temperature range pumped: from 0 °C to +35 °C - Maximum ambient temperature: +40°C A Q IMP gpm Q US gpm 0 0 2 4 6 8 10 12 14 16 18 20 22 24 2 4 6 8 10 12 14 16 18 20 C SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS P kPa H m H ft DNM 140 40 400 DNA JETCOM 132 120 30 300 100 H 80 H2 20 200 60 Hs 9 8 6 7 40 F 10 100 5 4 3 E I 20 G 2 Q m3/h 0 1 2 3 4 5 0 0 0 B Q l/s Q l/min 0 0,2 0,4 0,6 0,8 1 1,2 1,4 0 10 20 30 40 50 60 70 80 90 The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906. ELECTRICAL DATA MODEL CAPACITOR kW HP μF Vc P2 NOMINAL In POWER SUPPLY 50 Hz P1 MAX kW A JETCOM 132 M 1x220-240 V ~ 1.49 1 1.36 6.6 25 450 JETCOM 132 T 3x230-400 V ~ 1.43 1 1.36 4.7-2.7 – – PACK DIMENSIONS VOLUME GROSS WEIGHT MODEL A B C E F G H H1 H2 I Ø L DNA GAS DNM GAS (mc) Kg L/A L/B H JETCOM 132 M 425 170 122 208 14 111 203 – 144 9 – 1” 1” 470 240 240 0.027 10.5 JETCOM 132 T 441 170 122 208 14 111 203 – 144 9 – 1” 1” 470 240 240 0.027 12.6 DAB PUMPS reserve the right to make modifications without prior notice 25