SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS

APPLICATIONS
Self priming centrifugal pump with excellent suction capacity even in the presence of air bubbles. 
Suitable for pumping water with low levels of sandy impurities. 
Especially used in domestic water supply installations. Suitable for small farms and gardening, small scale industrial services and where self priming is 
necessary. 

CONSTRUCTIONAL FEATURES OF THE PUMP
Pump body in technocpolymer and motor support in die cast aluminium.
Impeller, diffuser, venturi tube and sand guard in technopolymer
Stainless steel wear ring.
Carbon/ceramic mechanical seal.

CONSTRUCTIONAL FEATURES OF THE MOTOR
Asynchronous type, closed, with external air cooling. 
Rotor mounted on oversized greased-for-life ball bearings, to guarantee low noise and long life.
Incorporated thermo-amperometric protection and permanently inserted capacitor in the single phase version. 
It is recommended to use overload protection for three phase motor protection, in compliance with current legislation. 
Manufactured pursuant to CEI 2-3 and CEI 61-69 (EN 60335-2-41).

DAB PUMPS reserve the right to make modifications without prior notice
20

JETCOM
SELF-PRIMING CENTRIFUGAL ELECTRIC PUMPS

TECHNICAL DATA
Operating range: 
from 0.6 to 5.4 m3/h with head up to 54 metres. 
Liquid quality requirements: clean, free from solid or abrasive contaminants, 
non-viscous, non-aggressive, uncrystallised and chemically neutral.
Liquid temperature range: from 0°C to +35°C for domestic use 
(EN 60335-2-41).
Maximum ambient temperature: +40°C
Maximum operating pressure: 6 bar (600 kPa)
Maximum suction depth: 8 metres.
Installation: fixed in a horizontal position.
Special executions on request: alternative voltages and/or frequencies.
Motor protection rating: IP 44
Terminal block protection rating: IP 55
Insulation class: F
Standard input voltage: single phase 220/240 V / 50 Hz
	 	
three phase  230/400 V - 50 Hz

Sayfa 2

JETCOM
SELF-PRIMING CENTRIFUGAL ELECTRIC PUMPS

MATERIALS

N°
PARTS *
MATERIALS

1
4
28
7

1
PUMP BODY
TECHNOPOLYMER A

4
IMPELLER
TECHNOPOLYMER A

7
SHAFT WITH ROTOR
AISI 416 STAINLESS STEEL 
X12 CrS13 - UNI 6900/71

16
MECHANICAL SEAL
CARBON/CERAMIC

28
OR GASKET
NBR RUBBER

3
16
160

36
SEAL HOLDER COVER
AISI 304 STAINLESS STEEL
X5 CRNi 1810 - UNI 6900/71

160
VENTURI DIFFUSER NOZZEL GROUP
TECHNOPOLYMER A

* In contact with liquid

SELF PRIMING CAPACITY

H
(ft)

10

10

30

9

9

8

8

25

7

7

20

Hs (m) Suction head

6

Hs (m) Suction head

6

5

5

15

4

4

10

3

3

2

2

G 1
DN 25

5

1

1

0
10
20
30
40
50
60
70
80
90
100
0
0

0
10
20
30
40
50
60
70
80
90
100
0
0

t (sec) Self priming timing

t (sec) Self priming timing

DAB PUMPS reserve the right to make modifications without prior notice

SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS

H
(ft)

30

25

20

15

10

5

21

Sayfa 3

JETCOM
SELF-PRIMING CENTRIFUGAL ELECTRIC PUMPS

SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS

PERFORMANCE RANGE
The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906.

GRAPHIC SELECTION TABLE

5
10
15
30
50

5
10
15
30
50

H
m
H
kPa

JET
JETINOX
JETCOM

GARDENJET
GARDEN INOX
GARDEN COM

AQUAJET
AQUAJET INOX

700

70

600

62 - 82 - 102 - 112
JET
JETINOX
JETCOM

60

GARDENJET
GARDEN INOX
GARDEN COM

AQUAJET
AQUAJET INOX

500

50

92 - 132

400

40

300

30

JET 151
JET 251

JET 200
JET 300

200

20

10

100

1

2
3
4
5
6
7
8
9
10
15

2
1
3
Q l/s

20
30
50
100
150
200

JETCOM SELECTION TABLE

Q=m3/h
0
0.6
1.2
1.8
2.4
3.0
3.6
4.2
4.8

MODEL

Q=l/min
0
10
20
30
40
50
60
70
80

JETCOM 62 M

42
35
29.2
25.6
22.9
13

JETCOM 82 M
47
40
34
30
26.2
23.5
20

JETCOM 102 M
53.8
47
41
36.3
32.4
28.8
25.8

H
(m)

JETCOM 102 T
53.8
47
41
36.3
32.4
28.8
25.8

JETCOM 92 M
36.2
33.5
31
28.4
26
24
21.8
19.6
17.5

JETCOM 132 M
48.3
45.6
42.8
40
37.6
35
32.5
30
27.2

JETCOM 132 T
48.3
45.6
42.8
40
37.6
35
32.5
30
27.2

DAB PUMPS reserve the right to make modifications without prior notice
22

Q US gpm

Q IMP gpm

H
ft

200

150

100

50

Q m3/h

Q l/min

Sayfa 4

JETCOM 62-SELF-PRIMING CENTRIFUGAL ELECTRIC PUMPS FOR DOMESTIC WATER SUPPLY
Liquid temperature range pumped: from 0 °C to +35 °C - Maximum ambient temperature: +40°C

A

Q US gpm

0

2
4
6
8
10
12

C

0

2
4
6
8
10

Q IMP gpm

SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS

P
kPa

H
m

H
ft

DNM

400

40

120

DNA

100

300

30

JETCOM 62

80

H

H2

200

20

Hs 9

60

8

7

6
5
4
2

40

F

100

10

3

E

I

20

G

0

0

Q m3/h
0
0,5
1
1,5
2
2,5
3
0

B

Q l/s

0

0,2
0,4
0,6
0,8

Q l/min

0

10
20
30
40
50

The performance curves are based on the kinematic viscosity values = 
1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906.

ELECTRICAL DATA

MODEL

CAPACITOR
kW
HP
μF
Vc

P2 NOMINAL
In 

POWER SUPPLY

50 Hz
P1
MAX kW

A

JETCOM 62 M
1x220-240 V ~
0.72
0.44
0.6
3.12
12.5
450

PACK DIMENSIONS
VOLUME

GROSS
WEIGHT

MODEL
A
B
C
E
F
G
H
H1
H2
I Ø
L
DNA
GAS

DNM

GAS

(mc)

Kg
L/A
L/B
H

JETCOM 62
406
170
122
208
14
111
198
–
144
9
–
1” 
1” 
470
240
240
0.027
7.5

JETCOM 82-SELF-PRIMING CENTRIFUGAL ELECTRIC PUMPS FOR DOMESTIC WATER SUPPLY
Liquid temperature range pumped: from 0 °C to +35 °C - Maximum ambient temperature: +40°C

A

Q US gpm

0

2
4
6
8
10
12
14
16

C

Q IMP gpm

0

2
4
6
8
10
12
14

P
kPa

H
m
H
ft

DNM

50

DNA

160

400

40

120

JETCOM 82

300

100

30

H

H2

80

Hs 9

200

20

60

8

7
6

F

40

5
4
3
2

E

100

10

I

20

G

0

0

Q m3/h
0
0,5
1
1,5
2
2,5
3
3,5
4
0

B

Q l/s

0

0,2
0,4
0,6
0,8
1

Q l/min

0

10
20
30
40
50
60

The performance curves are based on the kinematic viscosity values = 
1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906.

ELECTRICAL DATA

MODEL

CAPACITOR
kW
HP
μF
Vc

P2 NOMINAL
In 

POWER SUPPLY

50 Hz
P1
MAX kW

A

JETCOM 82 M
1x220-240 V ~
0.85
0.6
0.8
3.8
12.5
450

GROSS
WEIGHT

PACK DIMENSIONS
VOLUME

MODEL
A
B
C
E
F
G
H
H1
H2
I Ø
L
DNA
GAS

DNM

GAS

(mc)

Kg
L/A
L/B
H

JETCOM 82
406
170
122
208
14
111
198
–
144
9
–
1” 
1” 
470
240
240
0.027
7.7

DAB PUMPS reserve the right to make modifications without prior notice

23

Sayfa 5

JETCOM 102 - SELF-PRIMING CENTRIFUGAL ELECTRIC PUMPS FOR DOMESTIC WATER SUPPLY
Liquid temperature range pumped: from 0 °C to +35 °C - Maximum ambient temperature: +40°C

A

Q US gpm

0

2
4
6
8
10
12
14
16

C

0

2
4
6
8
10
12
14

Q IMP gpm

SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS

P
kPa

H
m
H
ft

DNM

50

DNA

160

400

40

JETCOM 102

120

100

300

30

H

Hs 9

H2

80

8
7

200

20

6
5
3

60

4
2

40

F

100

10

E

I

20

G

0

0

Q m3/h
0
0,5
1
1,5
2
2,5
3
3,5
4
0

B

Q l/s

0

0,2
0,4
0,6
0,8
1

Q l/min

0

10
20
30
40
50
60

The performance curves are based on the kinematic viscosity values = 
1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906.

ELECTRICAL DATA

MODEL

CAPACITOR
kW
HP
μF
Vc

P2 NOMINAL
In 

POWER SUPPLY

50 Hz
P1
MAX kW

A

JETCOM 102 M
1x220-240 V ~
1.13
0.75
1
5.1
16
450

JETCOM 102 T
3x230-400 V ~
1.04
0.75
1
3.3-1.9
–
–

PACK DIMENSIONS
VOLUME

GROSS
WEIGHT

MODEL
A
B
C
E
F
G
H
H1
H2
I Ø
L
DNA
GAS

DNM

GAS

(mc)

Kg
L/A
L/B
H

JETCOM 102
425
170
122
208
14
111
203
–
144
9
–
1” 
1” 
470
240
240
0.027
9.5

JETCOM 92-SELF-PRIMING CENTRIFUGAL ELECTRIC PUMPS FOR DOMESTIC WATER SUPPLY
Liquid temperature range pumped: from 0 °C to +35 °C - Maximum ambient temperature: +40°C

A

Q IMP gpm
Q US gpm

0
0

2
4
6
8
10
12
14
16
18
20
22
24
2
4
6
8
10
12
14
16
18
20

C

P
kPa

H
m
H
ft

DNM

140

DNA

40
400

120

100

30
300

JETCOM 92

H

80

H2

20
200

60

Hs

9

8

40

7
5
4
3

F

10
100

6

E

I

20

2

G

Q m3/h
0
1
2
3
4
5
0
0

0

B

Q l/s
Q l/min

0

0,2
0,4
0,6
0,8
1
1,2
1,4

0

10
20
30
40
50
60
70
80
90

The performance curves are based on the kinematic viscosity values = 
1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906.

ELECTRICAL DATA

MODEL

CAPACITOR
kW
HP
μF
Vc

P2 NOMINAL
In 

POWER SUPPLY

50 Hz
P1
MAX kW

A

JETCOM 92 M
1x220-240 V ~
0.94
0.75
1
4.2
14
450

GROSS
WEIGHT

PACK DIMENSIONS
VOLUME

MODEL
A
B
C
E
F
G
H
H1
H2
I Ø
L
DNA
GAS

DNM

GAS

(mc)

Kg
L/A
L/B
H

JETCOM 92
425
170
122
208
14
111
203
–
144
9
–
1” 
1” 
470
240
240
0.027
8.7

DAB PUMPS reserve the right to make modifications without prior notice
24

Sayfa 6

JETCOM 132 - SELF-PRIMING CENTRIFUGAL ELECTRIC PUMPS FOR DOMESTIC WATER SUPPLY
Liquid temperature range pumped: from 0 °C to +35 °C - Maximum ambient temperature: +40°C

A

Q IMP gpm
Q US gpm

0
0

2
4
6
8
10
12
14
16
18
20
22
24
2
4
6
8
10
12
14
16
18
20

C

SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS

P
kPa

H
m
H
ft

DNM

140

40
400

DNA

JETCOM 132

120

30
300

100

H

80

H2

20
200

60

Hs

9

8
6

7

40

F

10
100

5
4
3

E

I

20

G

2

Q m3/h
0
1
2
3
4
5
0
0

0

B

Q l/s
Q l/min

0

0,2
0,4
0,6
0,8
1
1,2
1,4

0

10
20
30
40
50
60
70
80
90

The performance curves are based on the kinematic viscosity values = 
1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906.

ELECTRICAL DATA

MODEL

CAPACITOR
kW
HP
μF
Vc

P2 NOMINAL
In 

POWER SUPPLY

50 Hz
P1
MAX kW

A

JETCOM 132 M
1x220-240 V ~
1.49
1
1.36
6.6
25
450

JETCOM 132 T
3x230-400 V ~
1.43
1
1.36
4.7-2.7
–
–

PACK DIMENSIONS
VOLUME

GROSS
WEIGHT

MODEL
A
B
C
E
F
G
H
H1
H2
I Ø
L
DNA
GAS

DNM

GAS

(mc)

Kg
L/A
L/B
H

JETCOM 132 M
425
170
122
208
14
111
203
–
144
9
–
1” 
1” 
470
240
240
0.027
10.5

JETCOM 132 T
441
170
122
208
14
111
203
–
144
9
–
1” 
1” 
470
240
240
0.027
12.6

DAB PUMPS reserve the right to make modifications without prior notice