Bu sayfa, kılavuzun PDF dosyasındaki metnin tamamıdır (sayfa sayfa). Görseller ve çizimler için PDF'i açın. — sibastore.com
APPLICATIONS Multi-stage centrifugal pump with horizontal shaft, featuring extremely quiet operation suitable for domestic water supply and pressurisation, irrigation of gardens and general water movement. CONSTRUCTIONAL FEATURES OF THE PUMP Pump body in technocpolymer. Motor support in die cast aluminium, with seal holder cover in AISI 304 stainless steel. Carbon/ceramic mechanical seal. Rotor shaft in AISI 304 stainless steel. Impeller and diffuser bodies and diffuser in technopolymer. Stainless steel wear ring. CONSTRUCTIONAL FEATURES OF THE MOTOR Asynchronous, continuous service motor. Incorporated thermo-amperometric protection and permanently inserted capacitor in the single phase version. Overload protection to be provided by the user for the three-phase version. MATERIALS N° PARTS* MATERIALS 1 PUMP BODY TECHNOPOLYMER 4 IMPELLER TECHNOPOLYMER 6 DIFFUSER TECHNOPOLYMER 7 SHAFT WITH ROTOR AISI 304 STAINLESS STEEL X5CrNi 1810 UNI 6900/71 16 MECHANICAL SEAL CARBON/CERAMIC 28 OR GASKET NBR 36 SEAL HOLDER COVER AISI 304 STAINLESS STEEL X5CRNI 1810 UNI 6900/71 98 DIFFUSER BODY TECHNOPOLYMER 304 REAR DISC TECHNOPOLYMER * In contact with liquid DAB PUMPS reserve the right to make modifications without prior notice EUROCOM MULTISTAGE CENTRIFUGAL PUMPS SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS TECHNICAL DATA Operating range: from 10 to 120 litres/min. with head up to 72 m. Liquid quality requirements: clean, free from solid or abrasive contaminants, non-viscous, non-aggressive, uncrystallised and chemically neutral, close to the properties of water. Liquid temperature range: for domestic use: from 0°C to +35°C (EN 60335-2-41) for other use: from 0°C to +40°C Maximum ambient temperature: +40°C Maximum operating pressure: 6 bar (600 kPa) Installation: fixed or portable in a horizontal position. Motor protection rating: IP 44 Terminal block protection rating: IP 55 Insulation class: F Standard input voltage: single phase 220/240 V - 50 Hz three phase 230/400 V - 50 Hz 1 4 16 304 28 36 6 7 98 51
EUROCOM MULTISTAGE CENTRIFUGAL PUMPS SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS PERFORMANCE RANGE The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906. GRAPHIC SELECTION TABLE 5 10 15 30 50 5 10 15 30 50 H m H kPa EURO 50 EUROINOX 50 EUROCOM 50 700 70 600 60 500 50 400 40 300 30 MULTI INOX EURO 80 EUROINOX 80 EUROCOM 80 EURO 30 EUROINOX 30 EUROCOM 30 200 20 10 100 1 2 3 4 5 6 7 8 9 10 15 2 1 3 Q l/s 20 30 50 100 150 200 EUROCOM SELECTION TABLE Q=m3/h 0 0.6 1.2 1.8 2.4 3.0 3.6 4.2 4.8 6 7.2 MODEL Q=l/min 0 10 20 30 40 50 60 70 80 100 120 EUROCOM 25/30 M 34.4 31.7 28.3 23.5 17.5 11 EUROCOM 30/50 M 42.2 40.2 38.2 36.2 33.8 30 24.8 19.5 14 H (m) EUROCOM 40/50 M 57.7 55.3 52.8 50.1 47.1 42.7 35.8 28 19.2 EUROCOM 40/50 T 57.7 55.3 52.8 50.1 47.1 42.7 35.8 28 19.2 EUROCOM 30/80 T 47 46.5 45 43.5 41 38 34.5 31 23 12 DAB PUMPS reserve the right to make modifications without prior notice 52 Q US gpm Q IMP gpm H ft 200 150 100 50 Q m3/h Q l/min
EUROCOM 30-SELF-PRIMING MULTISTAGE CENTRIFUGAL PUMPS CENTRIFUGAL ELECTRIC PUMPS FOR
DOMESTIC WATER SUPPLY
Liquid temperature range pumped: from 0 °C to +35 °C - Maximum ambient temperature: +40°C
0
Q US gpm
2
4
6
8
10
12
14
SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS
A
0
2
4
6
8
10
12
Q IMP gpm
H
m
P
kPa
H
ft
C
55
180
DNM
50
500
160
DNA
45
140
400
40
120
35
H1
300
100
30
25
80
EUROCOM 25/30
200
20
E
F
60
15
40
100
10
20
5
0
0
0
0
0,5
1
1,5
2
2,5
3
3,5
Q m3/h
m
NPSH
H
NPSH
kPa
ft
30
3
8
20
2
4
10
1
0
0
0
I
0
0,5
1
1,5
2
2,5
3
3,5
Q m3/h
0
0,2
0,4
0,6
0,8
1
Q l/s
G
0
10
20
30
40
50
60
Q l/min
B
The performance curves are based on the kinematic viscosity values =
1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906.
ELECTRICAL DATA
MODEL
CAPACITOR
kW
HP
μF
Vc
P2 NOMINAL
In
N°
IMPELLER
POWER SUPPLY
50 Hz
P1 MAX
KW
A
EUROCOM 25/30 M
3
1x220-240 V ~
0.52
0.37
0.5
2.4
10
450
PACK DIMENSIONS
VOLUME
GROSS WEIGHT Kg
MODEL
A
B
C
E
F
G
I Ø
H
H1
H2
DNA
GAS
DNM
GAS
(mc)
L/A
L/B
H
M
T
EUROCOM 25/30 M
406
170
122
208
14
111
9
198
144
–
1”
1”
470
240
240
0.027
8
8
DAB PUMPS reserve the right to make modifications without prior notice
53EUROCOM 50-SELF-PRIMING MULTISTAGE CENTRIFUGAL PUMPS CENTRIFUGAL ELECTRIC PUMPS FOR
DOMESTIC WATER SUPPLY
Liquid temperature range pumped: from 0 °C to +35 °C - Maximum ambient temperature: +40°C
SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS
0
Q US gpm
2
4
6
8
10
12
14
16
18
20
A
0
2
4
6
8
10
12
14
16
Q IMP gpm
H
m
P
kPa
H
ft
C
240
700
70
DNM
DNA
600
200
60
EUROCOM 40/50
500
50
160
H1
400
40
120
EUROCOM 30/50
300
30
E
F
80
200
20
40
100
10
0
0
0
0
1
2
3
4
5
Q m3/h
m
NPSH
H
kPa
NPSH
ft
40
4
10
12
30
3
8
6
4
1
20
2
10
0
1
2
3
4
5
Q m3/h
I
0
0,2
0,4
0,6
0,8
1
1,2
1,4
Q l/s
G
0
10
20
30
40
50
60
70
80
Q l/min
B
The performance curves are based on the kinematic viscosity values =
1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906.
ELECTRICAL DATA
MODEL
CAPACITOR
kW
HP
μF
Vc
P2 NOMINAL
In
N°
IMPELLER
POWER SUPPLY
50 Hz
P1 MAX
KW
A
EUROCOM 30/50 M
3
1x220-240 V ~
0.88
0.55
0.75
3.9
12.5
450
EUROCOM 40/50 M
4
1x220-240 V ~
1.2
0.75
1
5.3
25
450
EUROCOM 40/50 T
3x230-400 V ~
1.18
0.75
1
3.8-2.2
–
–
GROSS
WEIGHT
PACK DIMENSIONS
VOLUME
MODEL
A
B
C
E
F
G
I Ø
H
H1
H2
DNA
GAS
DNM
GAS
(mc)
Kg
L/A
L/B
H
EUROCOM 30/50 M
406
170
122
208
14
111
9
198
144
–
1”
1”
470
240
240
0.027
8.8
EUROCOM 40/50 M
406
170
122
208
14
111
9
203
144
–
1”
1”
470
240
240
0.027
11
EUROCOM 40/50 T
422
170
122
208
14
111
9
203
144
–
1”
1”
470
240
240
0.027
12.5
DAB PUMPS reserve the right to make modifications without prior notice
54EUROCOM 80-SELF-PRIMING MULTISTAGE CENTRIFUGAL PUMPS CENTRIFUGAL ELECTRIC PUMPS FOR
DOMESTIC WATER SUPPLY
Liquid temperature range pumped: from 0 °C to +35 °C - Maximum ambient temperature: +40°C
0
Q US gpm
4
8
12
16
20
24
28
SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS
A
0
4
8
12
16
20
24
Q IMP gpm
H
m
P
kPa
H
ft
C
55
180
DNM
500
50
160
EUROCOM 30/80
DNA
45
140
400
40
120
35
H1
100
300
30
25
80
EUROCOM 25/80
200
E
F
20
60
15
40
100
10
20
5
0
0
0
Q m3/h
0
1
2
3
4
5
6
7
m
NPSH
kPa
NPSH
H
ft
50
5
16
40
4
12
30
3
0
Q m3/h
20
8
2
I
1
2
3
4
5
6
7
0
0,4
0,8
1,2
1,6
2
Q l/s
G
0
20
40
60
80
100
120
Q l/min
B
The performance curves are based on the kinematic viscosity values =
1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906.
ELECTRICAL DATA
MODEL
CAPACITOR
kW
HP
μF
Vc
P2 NOMINAL
In
N°
IMPELLER
POWER SUPPLY
50 Hz
P1 MAX
KW
A
EUROCOM 30/80 T
4
3x230-400 V ~
1.04
0.8
1.1
3.3-1.9
–
–
PACK DIMENSIONS
VOLUME
GROSS WEIGHT Kg
MODEL
A
B
C
E
F
G
I Ø
H
H1
H2
DNA
GAS
DNM
GAS
(mc)
L/A
L/B
H
M
T
EUROCOM 30/80 T
425
170
122
208
14
111
9
203
144
–
1”
1”
470
240
240
0.027
11
11.3
DAB PUMPS reserve the right to make modifications without prior notice
55