RUZIFAN 5 Single Room Energy Recovery Ventilator Instruction Manual
SAFETY REQUIREMENTS 3 INTRODUCTION 5 USE 6 PACKING LIST 6 MAIN TECHNICAL PARAMETERS 7 DESIGN AND OPERATION 8 INSTALLATION DRAWING 9 OPERATION MODES 10 VENTILATOR INSTALLATION 11 FUNCTION DESCRIPTION 14 REMOTE CONTROLLER 15 PAIRING SYNCHRONIZATION FUNCTION 16 LEADER UNIT SETTINGS 17 FOLLOWER UNIT SETTINGS 18 LEADER AND FOLLOWERUNITS RESET AND CANCELLATION 18 IOT NETWORKING FEATURES 19 IOT NETWORKING OPERATION STEPS 21 MAINTENANCE 23 STORAGE AND TRANSPORTATION RULES 24 TROUBLESHOOTING 25
Ventilator Installation Safety Precautions The ventilator must be disconnected from the power supply before the installation or repair operation. The ventilator must not be operated outside the temperature range specified in the user’s manual or in aggressive or explosive environment. Do not place any heating devices or other equipment in close proximity to the ventilator power cord. Do not use damaged equipment or conductors to connect the ventilator to power. While installing the ventilator, follow the safety regulations specific to the use of electric tools. Unpack the ventilator with care. Use the ventilator only as intended by the manufacturer.
USE • The ventilator is designed to exchange air in apartments, villas, hotels, cafes, and other domestic and public buildings. The ventilator is equipped with a ceramic energy regenerator and a fan that supplies fresh air and extracts air with energy recovery. • The ventilator is designed for through the wall mounting. The telescopic design of the fan allows its installation in walls from 280 mm to 470mm thick. • The ventilator is designed for continuous operation always connected to power supply. • The transported air must not contain any flammable or explosive mixtures, evaporation of chemicals, coarse dust, soot and oil particles, sticky substances, fibrous materials, pathogens, or any other harmful substances. INSTALLATION AND CONNECTION OPERATIONS MUST BE PERFORMED ONLY BY PROPERLY QUALIFIED PERSONNEL AFTER THE APPROPRIATE SAFETY BRIEFING. THE VENTILATOR INSTALLATION SITES MUST PREVENT ACCESS BY UNATTENDED CHILDREN. PACKING LIST Ventilator 1 pc Accessories bag 1 pc Remote controller 1 pc User’s manual 1 pc Packing box 1 pc
MAIN TECHNICAL PARAMETERS - The ventilator is designed for indoor application with an ambient temperature ranging from -20°C (-4°F) to +50°C (+122°F) and relative humidity below 80%. - The ventilator is classified as a class II electric appliance. - Ingress Protection (IP) rating is IPX4. - The ventilator design is subject to continuous improvement, so some models may differ slightly from the models described in this manual. Ventilator Overall Dimensions (mm) | Description | Unit | Value | | :--- | :--- | :--- | | Voltage | V | 120 | | Frequency | Hz | 60 | | Input Power | W | 6/7/7.8 | | RPM | - | 1000/1550/1800 | | RPM (max) | - | 2200 | | Airflow (L/M/H) in supply/exhaust mode (with F7 filter)* | m³/h | 20/40/50 | | Airflow (L/M/H) in regeneration mode (with F7 filter)* | m³/h | 10/20/25 | | Airflow in supply/exhaust mode (with F7 filter)* | CFM | 11.8/23.5/29.4 | | Airflow in regenerator mode (with F7 filter)* | CFM | 5.9/11.8/15 | | Max airflow (under fan boost mode) | m³/h | 60 | | Max airflow (under fan boost mode) | CFM | 35 | | Sound Pressure Level | dB(A) | 32.7 | | Heat Recovery Efficiency | % | up to 97 | | Ingress Protection Rating | - | IPX4 | | Air Duct Diameter | mm | 158 | | SEC | - | Class A | | Mounting Type | - | Wall Mounting | | Net Weight | kg | 5.2 | *Note: This product is compatible with an AC voltage range of 100-240V. *Note: The airflow in supply/exhaust mode without F7 filter is about 34/56/70 CMH or 20/33/41.2 CFM, and the relative parameters will be adjusted accordingly. DESIGN AND OPERATION - The ventilator consists of a telescopic air duct with adjustable length regulated by the position of the inner air duct inside the outer air duct, the ventilation unit, and the ventilation hood. - F7 filter+prefilter and the ceramic energy regenerator are located inside the inner duct. The filters are designed to purify supply air and prevent foreign objects from ingress into the regenerator and the fan. - The ceramic energy regenerator extracts energy from exhaust air to warm up or cool down supply air. - The regenerator is equipped with a pull cord inside to facilitate its withdrawal from the ventilator. The regenerator is installed on an insulation material which is used as a sealant as well. - The ventilator is available to be installed from the inner side of the wall.
INSTALLATION AND SET-UP Read The User’s Manual Before Installation The Ventilator To prevent room dust deposition and accumulation, the ventilator must not be installed in places where the air duct may be blocked by the blinds, curtains, drapes, etc. Meanwhile, curtains might obstruct normal airflow in the room, making ventilator operation inefficient. OPERATION MODES Ventilation Mode. The ventilator runs in exhaust or supply mode at a set speed. When synchronous operation of two connected ventilators, one runs in the supply mode and the other in exhaust mode. Regeneration Mode. The ventilator runs in two cycles of 75 seconds each, to provide heat and moisture regeneration. Interval 1 The warm polluted air is extracted from the room and goes through the ceramic regenerator, which gradually absorbs heat and moisture. After 75 seconds the ventilator switch to air supply mode. Interval 2 The fresh and cold outdoor air goes through the heat regenerator and absorbs the accumulated moisture and heat after 75 seconds, when the energy regenerator gets cold, the ventilator switches to the exhaust mode.
2. Pull the mobile bracket into the outer duct back into place so that the silicone ring on the outside of the outer duct is tight against the outer wall. Fill the space between the wall and the outer duct with the PU glue provided in the kit before attaching the back cover mounting plate, and then wait for the glue to dry. Then install the back cover mounting plate, align the round hole of the back cover the mounting plate with the round hole on the wall, and measure the level of the mounting plate with a level ruler to ensure that the mounting plate installation is horizontal, then mark the hole, punch in the expansion rubber grain, then align the mounting plate with the hole and fixing it with a screw. 3. Pull the mobile bracket into the outer duct back into place so that the silicone ring on the outside of the outer duct is tight against the outer wall. Fill the space between the wall and the outer duct with the PU glue provided in the kit before attaching the back cover mounting plate, and then wait for the glue to dry. Then install the back cover mounting plate, align the round hole of the back cover the mounting plate with the round hole on the wall, and measure the level of the mounting plate with a level ruler to ensure that the mounting plate installation is horizontal, then mark the hole, punch in the expansion rubber grain, then align the mounting plate with the hole and fixing it with a screw. 4. Pull the mobile bracket into the outer duct back into place so that the silicone ring on the outside of the outer duct is tight against the outer wall. Fill the space between the wall and the outer duct with the PU glue provided in the kit before attaching the back cover mounting plate, and then wait for the glue to dry. Then install the back cover mounting plate, align the round hole of the back cover the mounting plate with the round hole on the wall, and measure the level of the mounting plate with a level ruler to ensure that the mounting plate installation is horizontal, then mark the hole, punch in the expansion rubber grain, then align the mounting plate with the hole and fixing it with a screw.
3. Install the main unit on the indoor surface wall, and connect the adapter wire from the back of the main unit to the wiring of the fan and temperature sensor exposed by the inner duct in the wall. Tidy the wiring, align the main unit with the plastic block protruding on the back cover board and install it in. (There are corresponding concave holes on the back of the main unit.) Just install it, no other operations are required. The back of the main unit is equipped with a strong magnet, which will automatically attract the mounting plate on the wall (After installation, please check that if there is a large gap between the main unit and the mounting plate. If yes, it means that the wires in the main unit are not sorted out. Therefore, please remove the main unit and reinstall it). Function Light (RGB-LED) 1. Function light indicates the fan speed, 3 speeds in total. 2. The green light indicates air supply. 3. The red shows as air exhaust. 4. The blue shows as the regeneration mode, which switches after 75 seconds of cyclic operation between air supply and air exhaust. OFF status (coordinate with the buttons) 1. Blue light flashes slowly: Indicates the device role set as the leader in pairing mode. 2. Green light flashes slowly: Indicates the role of the device set as a follower in pairing mode. 3. Red light flashes slowly: Indicates that the device is in WIFI connection mode. CONNECTION TO POWER DISCONNECT THE VENTILATION FROM THE POWER SUPPLY TO ANY ELECTRIC INSTALLATION OPERATIONS. THE VENTILATOR IS DESIGNED FOR CONNECTION TO SINGLE-PHASE AC100-240 V/50-60 HZ POWER SUPPLY. CONNECT THE VENTILATOR TO THE SOCKET DIRECTLY.
1. Without setting a leader/follower role, one remote control can control one or more devices. 2. After setting the leader/follower role, the current use of the remote control can only control the leader, and the leader will send the synchronization signal to the follower (the follower does not receive the remote control signal), so that the follower mode is synchronized with the leader. (The leader can only control one follower alone). 3. In regeneration mode, the operation direction of the follower fan is opposite to that of the leader, and the direction of the follower fan in other modes is the same as that of the leader. • The maximum linear unobstructed communication signal distance between leader and follower is 15m. • The signal from the leader and follower can pass through a 180mm thick brick wall.
Follower Unit Settings 1. Connect the device to power. In the OFF state, as shown in the figure, long press the mode button of the device for 5 seconds, and the status indicator green light flashes slowly. At this time, the device enters the leader-follower linkage mode, the unit is set to the follower role. 2. During the leader and follower set pairing mode, it should be carried out at the same time for a limited time (within 1 minute). The devices should be as close as possible, the device will be automatically connected. 3. The status light of the paired devices will change to blue light ON to indicate that leader-follower pairing is successful. 4. If the leader-follower pairing fails, the status lights on the devices will flash for one minute and then light-off automatically. ▶ LEADER-FOLLOWER RESET AND CANCELLATION Connect the device with power. In the OFF state, long press the fan speed button of the linked device for 5 seconds, and the device status indicator blue light flashes slowly. At this time, the linked device enters the leader-follower linkage mode, the device definition is the leader role. It should be carried out at the same time for a limited time (within 1 minute), and wait for the status indicator lighting off automatically, then the device is not connected to the follower to break off the leader-follower pairing automatically as well. At this stage, the device is reset and restored to the factory state, without any role definition.
IOT NETWORKING FUNCTIONS CO₂ Version ERV name. The app can connect multiple devices. Each device will have a different name, and user can change the device name freely. Pairing icon. After the devices are paired, the icon is displayed, and the follower is offline and can’t be operated. Filter alarm. It reminds the user to clean or replace the filters. Icon disappears after reset. CO₂ concentration setting. When the CO₂ sensor is connected, if the indoor CO₂ concentration exceeds the set value while the unit is operating in regeneration mode, the unit will enter the supply mode to introduce fresh air to dilute the CO₂ concentration until the CO₂ concentration is lower than the set value. The unit then returns to the previous mode. It can be set from 400 to 2000ppm. 12-hours timer. Power ON/OFF. Operating mode (supply mode, exhaust mode, regeneration mode). CO₂ concentration function ON/OFF. CO₂ Switch Free Cooling Anion Light Indicator lights ON/OFF. Outdoor temperature. It displays the outdoor temperature when the unit is ON and operating in supply or regeneration mode. In exhaust mode, the outdoor temperature is not sensed and displayed. Free cooling temperature setting. When the outdoor air is comfortable, it will work in supply mode to introduce fresh air without heat recovery, it’s called free cooling. Users can set the outdoor temperature to enable this function. The setting range is 10°C to 29°C. Real-time indoor CO₂ concentration. Remaining time after the scheduled shutdown. Fan boost function. The unit will supply/exhaust at the highest speed. Fan speed, total 3 speeds. APP DOWNLOAD INSTRUCTIONS Scan the QR code on the right to download the app, or search “smart life” in the Apple store and Google play store to install the app, download, and install using the device’s WIFI connection. It’s available for the mobile app to control the device and support Google and Alexa Smart speaker control function.
RUZIFAN 5 RUZIFAN 5
Fan Maintenance (Once Per Year). Remove the fixed bracket in the inner duct and take out the fan. Clean the impeller blades. Use a soft brush, doth, or a vacuum cleaner to clean the impeller. Do not use water abrasive detergents, solvents, or sharp objects. The impeller blades must be cleaned once a year. STORAGE AND TRANSPORTATION RULES Store the ventilator in the manufacturer’s original packing box in a dry place. The storage environment must be free of contain aggressive vapors and chemical mixtures that may cause corrosion, insulation, and sealing deformation. Use lifting equipment for handling and storage operations to prevent ventilator from damage as a consequence of failing or excessive vibration. Fulfill the handling requirements applicable for the applicable freight type. Transportation by any type vehicle of allowed provided that the ventilator is protected against mechanical and weather damage. Avoid any mechanical shocks and strokes during handling operations.
TROUBLESHOOTING | Fault | Possible reasons | Troubleshooting | | :--- | :--- | :--- | | The fan does not Start up. | No power supply. | Make sure that the ventilator is properly connected to the power and make any corrections, if necessary. | | | The motor is stuck, or the impellers are clogged. | Turn the ventilator off. Troubleshoot the motor jam and the impeller dogging. Clean the blades. Restart the ventilator. | | Low airflow. | Low fan speed setting. | Set higher speed. | | | Filter, fan, or exchanger are dirty. | Clean or replace the filter, and clean the fan and the exchanger. For exchanger and filter maintenance, see page 23. | | Noise, vibration. | The impeller is dirty. | Clean the impeller. | | | Loose screw Connection of the ventilator casing or the ventilation hood. | Tighten the screws of the ventilator or the outer hood. | | Leader-Follower pairing failed. | Leader-Follower units set by a different controller. | According to the manual, use the same remote controller for the Leader-Follower units settings. | | | The ventilator is installed where is surrounded by a lot of metal/there are sources of interference. | Excessive metal structures and interference sources around will weaken the wireless signal, please remove these sources of interference or change the installation location. | | | The distance between Leader and Follower units is too long/the wall between them is too thick. | Please change the installation location according to the distance specified in the manual. | | | Other | Please reset the leader-follower setting (press and hold the RESET button for ten seconds), and set it again after a period of power off. | | WIFI connection failed. | The mobile phone is connected to the WiFi 5G network. | Please switch to the 2.4G frequency/network to connect. | | | Wrong connected to public WiFi (such as WiFi in shopping malls, hotels, etc. That need to be registered and logged in). | Please set up the WIFI router correctly. | | | The router has not yet set up an account and password. | | | | The router is set to a higher security level. | | | | You have exceeded the limit of devices that can be connected to the router. | Enable Bluetooth on the mobile phone to improve the success rate of networking. |