Bu sayfa, kılavuzun PDF dosyasındaki metnin tamamıdır (sayfa sayfa). Görseller ve çizimler için PDF'i açın. — sibastore.com
Use and Maintenance
- BR 652/752/752C
ATTENTION! Do not use the machine before you have read and understood the Instructions for use manual
External battery charger
Machine with battery charger
1a. Switch off charger by pressing the
STOP button. Unplug charger cable
from red battery plug. Reconnect
the red battery plug to the machine.
1b. Disconnect the battery charger
cable from the electrical main.
5. Place the brushes or the pad-holders
under the deck. Use the appropriate
brushes to clean the floor.
6. Turn the ignition key to “I”, then
lower the deck by pressing the Green
switch. To engage the brushes,
slightly press the pedal speed and
then release it.
11. Push the pedal speed for starting
floor cleaning. If solution applied
flows outside the brush housing dur-
ing use, reduce the flow of solution.
Switch off the machine using the key.
10. If necessary press the extra pressure
function switch.
If necessary press the mute func-
tionswitch for reduce the noise.
15. Remove the brush by turn-
ing as indicated with
the figure and clean them.
16. Take the squeegee off and remove
debris. Check and clean the squeegee
blades.
If the machine has been used until the Red light illuminates on the battery level indicator on the machine, a full recharge of the batteries (10-12 hours) will be required. Failure to
carry out this this procedure may cause damage to the batteries. Charging the batteries after every use is recommended.
PLEASE ENSURE RED SOCKET IS LEFT DISCONNECTED AFTER RECHARGE IF THE MACHINE IS NOT TO BE USED ON A DAILY BASIS
Nilfisk A/S
Kornmarksvej 1
DK-2605 Brøndby
Denmark
Tel.: +45 43 23 40 50
Fax: +45 43 43 77 00
mail.com@nilfisk.com
www.nilfisk.com
2. Fill the tank with a clean water. The
clean water temperature must not
exceed 40 °C.
3. Fill the EcoFlex tank with a deter-
gent suitable for the work to be
performed (highly concentrated
detergent).
4. Install the squeegee and fasten it
with the handwheels, then connect
the vacuum hose to the squeegee.
7. Press the solution flow control
switches as necessary, depending
on the type of cleaning to be per-
formed.
8. Press the detergent flow control
switch. The number of display shows
the detergent concentration level in
the solution.
9. Lift the EcoFlex™ lever whenever you
temporarily need a greater cleaning
power.
See the User Manual for setting change.
14. Clean the filter: 1) Close the solu-
tion tap under the machine. 2)
Remove the transparent cover and
the gasket, then remove the filter
strainer.
12. At the end of the work. Empty the
recovery tank with the hose. Then
empty the solution tank by open-
ing the left drain tap and using the
adapter and the vacuum system
hose.
13. Wash with clean water the recovery
tank and the vacuum grid. Remove
and clean the debris tray.
18. Charge the batteries: Connect the
battery charger cable from the elec-
trical main.
17. Clean the machine using a damp
cloth and where needed use a neutral
cleaning product.
19. Park the machine with the recovery
tank cover open.Troubleshooting - BR 652/752/752C ATTENTION! Do not use the machine before you have read and understood the Instructions for use manual The machine doesn’t work as it should? 1 Check if the power cable is correctly connected. The suction doesn’t work as it should? 1 Check if the suction hose is correct- ly mounted and cleaned. The machine doesn’t clean as it should? 1 Check if you have the right deter- gent and water settings. The brush don’t work as they should? 1 Check if the brushes are correctly installed and not worn out. Nilfisk A/S Kornmarksvej 1 DK-2605 Brøndby Denmark Tel.: +45 43 23 40 50 Fax: +45 43 43 77 00 mail.com@nilfisk.com www.nilfisk.com 2 Check if the battery is charged. 3 Turn the ignition key to “0”, then try to start the machine without pressing the pedal speed. 4 Check if the surfaces has a gradient exceeding the specifications. 2 Open the recovery tank and check if the vacuum grid and gasket are cleaned. 3 Check if squeegee blades are dam- aged or dirty. 4 Close the recovery tank cover prop- erly and/or verify the gasket wear. 2 Check if the right solution/clean water tap is open. 3 Check if the solution filter is cleaned. 4 Check if the isn’t any dirty in the EcoFlex™ system. 3 Check if there are external materials avoiding brush rotating. 2 Check if there isn’t any brush motor overload i.e. 3 battery Ledsflash si- multaneously. 4 Check if the green switch Led is flashing. Wait until the light is steady.